Industrial valves - Face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems - PN and Class designated valves

This document specifies the “face-to-face” (FTF) and “centre-to-face” (CTF) dimensions for PN and Class designated metal valves used in flanged pipe systems.
This document covers valves with the following PN, Class and DN values:
—   PN 2,5; PN 6; PN 10; PN 16; PN 25; PN 40; PN 63; PN 100; PN 160; PN 250; PN 320; PN 400;
—   Class 125; Class 150; Class 250; Class 300; Class 600; Class 900; Class 1 500; Class 2 500;
—   DN 10; DN 15; DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200; DN 250; DN 300; DN 350; DN 400; DN 450; DN 500; DN 600; DN 700; DN 750; DN 800; DN 900; DN 1 000; DN 1 050; DN 1 200; DN 1 400; DN 1 600; DN 1 800; DN 2 000.
For valves in other shell materials than metal the same FTF and CTF dimensions can be used.
For relationship between DN and NPS, see Annex B.

Industriearmaturen - Baulängen von Armaturen aus Metall zum Einbau in Rohrleitungen mit Flanschen - Nach PN und Class bezeichnete Armaturen

Dieses Dokument legt die Baulängen „Face-to-Face“ (FTF) und „Centre-to-Face“ (CTF) für nach PN und Class bezeichnete Armaturen aus Metall fest, die in Rohrleitungssystemen mit Flanschen eingesetzt werden.
Dieses Dokument umfasst Armaturen mit den folgenden PN-, Class- und DN-Werten:
   PN 2,5; PN 6; PN 10; PN 16; PN 25; PN 40; PN 63; PN 100; PN 160; PN 250; PN 320; PN 400;
   Class 125; Class 150; Class 250; Class 300; Class 600; Class 900; Class 1 500; Class 2 500;
   DN 10; DN 15; DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200; DN 250; DN 300; DN 350; DN 400; DN 450; DN 500; DN 600; DN 700; DN 750; DN 800; DN 900; DN 1 000; DN 1 050; DN 1 200; DN 1 400; DN 1 600; DN 1 800; DN 2 000.
Für Armaturengehäuse aus anderen Werkstoffen als Metall können die gleichen Baulängen FTF und CTF verwendet werden.
Zum Verhältnis zwischen DN und NPS siehe Anhang B.

Robinetterie industrielle - Dimensions face-à-face et face-à-axe de la robinetterie métallique utilisée dans les systèmes de canalisations à brides - Appareils de robinetterie désignés PN et Class

Le présent document prescrit les dimensions "face-à-face" (FAF) et "face-à-axe" (FAA) des appareils de robinetterie métalliques désignés PN et désignés Class utilisés dans les réseaux de tuyauteries à brides.
Le présent document couvre les appareils de robinetterie dont les PN, Class et DN sont les suivantes :
—   PN 2,5; PN 6; PN 10; PN 16; PN 25; PN 40; PN 63; PN 100; PN 160; PN 250; PN 320; PN 400;
—   Class 125; Class 150; Class 250; Class 300; Class 600; Class 900; Class 1 500; Class 2 500;
—   DN 10; DN 15; DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200; DN 250; DN 300; DN 350; DN 400; DN 450; DN 500; DN 600; DN 700; DN 750; DN 800; DN 900; DN 1 000; DN 1 050; DN 1 200; DN 1 400; DN 1 600; DN 1 800; DN 2 000.
Pour les appareils de robinetterie comportant des matériaux d’enveloppe autres que métalliques, les mêmes dimensions FAF et FAA peuvent être utilisées.
Pour la relation entre DN et NPS, voir l’Annexe B.

Industrijski ventili - Vgradne dolžine kovinskih ventilov za cevovode s prirobnicami - Ventili, označeni po PN in Class

Ta dokument določa vgradne dolžine kovinskih ventilov, označenih po PN in Class, za vgradnjo v cevovode s prirobnicami.
Ta dokument zajema ventile z naslednjimi vrednostmi PN, Class in DN:
–   PN 2,5, PN 6, PN 10, PN 16, PN 25, PN 40, PN 63, PN 100, PN 160, PN 250, PN 320, PN 400;
–   Class 125, Class 150, Class 250, Class 300, Class 600, Class 900, Class 1 500, Class 2 500;
–   DN 10, DN 15, DN 20, DN 25, DN 32, DN 40, DN 50, DN 65, DN 80, DN 100, DN 125, DN 150, DN 200, DN 250, DN 300, DN 350, DN 400, DN 450, DN 500, DN 600, DN 700, DN 750, DN 800, DN 900, DN 1000, DN 1050, DN 1200, DN 1400, DN 1600, DN 1800, DN 2000.
Za ventile z ohišjem iz drugih materialov se lahko uporabijo enake vgradne dolžine.
Za razmerje med velikostmi DN in NPS glej dodatek B.

General Information

Status
Published
Publication Date
22-Feb-2022
Withdrawal Date
30-Aug-2022
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
23-Feb-2022
Due Date
02-Apr-2022
Completion Date
23-Feb-2022

Relations

Standard
EN 558:2022
English language
53 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2022
Nadomešča:
SIST EN 558:2017
Industrijski ventili - Vgradne dolžine kovinskih ventilov za cevovode s
prirobnicami - Ventili, označeni po PN in Class
Industrial valves - Face-to-face and centre-to-face dimensions of metal valves for use in
flanged pipe systems - PN and Class designated valves
Industriearmaturen - Baulängen von Armaturen aus Metall zum Einbau in Rohrleitungen
mit Flanschen - Nach PN und Class bezeichnete Armaturen
Robinetterie industrielle - Dimensions face-à-face et face-à-axe de la robinetterie
métallique utilisée dans les systèmes de canalisations à brides - Appareils de
robinetterie désignés PN et Class
Ta slovenski standard je istoveten z: EN 558:2022
ICS:
23.060.01 Ventili na splošno Valves in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 558
EUROPEAN STANDARD
NORME EUROPÉENNE
February 2022
EUROPÄISCHE NORM
ICS 23.040.99; 23.060.01 Supersedes EN 558:2017
English Version
Industrial valves - Face-to-face and centre-to-face
dimensions of metal valves for use in flanged pipe systems
- PN and Class designated valves
Robinetterie industrielle - Dimensions face-à-face et Industriearmaturen - Baulängen von Armaturen aus
face-à-axe de la robinetterie métallique utilisée dans Metall zum Einbau in Rohrleitungen mit Flanschen -
les systèmes de canalisations à brides - Appareils de Nach PN und Class bezeichnete Armaturen
robinetterie désignés PN et Class
This European Standard was approved by CEN on 10 January 2022.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 558:2022 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Dimensions and tolerances . 9
4.1 Basic series . 9
4.2 Face-to-face and centre-to-face dimensions. 9
4.2.1 General . 9
4.2.2 Class designated valves with ring joint flanges . 10
4.2.3 Valves with lining . 13
4.2.4 Raised face flanges . 13
4.3 Tolerances . 13
Annex A (informative) Origin of basic series . 46
Annex B (informative) Relationship between DN and NPS . 50
Annex C (informative) Overview of special basic series (compared to the previous version) . 51
Bibliography . 53
European foreword
This document (EN 558:2022) has been prepared by Technical Committee CEN/TC 69 “Industrial
valves”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by August 2022, and conflicting national standards shall be
withdrawn at the latest by August 2022.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 558:2017.
In comparison with the previous edition, the following technical modifications have been made:
— deletion of Table 2 and integration in the tables of the relevant product;
— basic series 125 added and used in Table 14;
— basic series 126, 127, 128 added and used in Table 21;
— basic series included in EN 558:2017 that are considered special transferred to Annex C.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
Introduction
The basic series given in this document are taken from the original series shown in Annex A. Changes
made to the original series will not be automatically incorporated into this document.
The numbers of the existing ISO basic series are maintained as in ISO 5752:2021.
1 Scope
This document specifies the “face-to-face” (FTF) and “centre-to-face” (CTF) dimensions for PN and Class
designated metal valves used in flanged pipe systems.
This document covers valves with the following PN, Class and DN values:
— PN 2,5; PN 6; PN 10; PN 16; PN 25; PN 40; PN 63; PN 100; PN 160; PN 250; PN 320; PN 400;
— Class 125; Class 150; Class 250; Class 300; Class 600; Class 900; Class 1 500; Class 2 500;
— DN 10; DN 15; DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200;
DN 250; DN 300; DN 350; DN 400; DN 450; DN 500; DN 600; DN 700; DN 750; DN 800; DN 900;
DN 1 000; DN 1 050; DN 1 200; DN 1 400; DN 1 600; DN 1 800; DN 2 000.
For valves in other shell materials than metal the same FTF and CTF dimensions can be used.
For relationship between DN and NPS, see Annex B.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 736-1, Valves - Terminology - Part 1: Definition of types of valves
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 736-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
3.1
face-to-face dimension
FTF
distance between the two planes perpendicular to the valve axis located at the extremities of the body
end ports or as specified in the relevant valve product standard
Note 1 to entry: It is applicable to straight pattern valves.
Note 2 to entry: See Figures 1 to 4.
Note 3 to entry: In millimetres.
3.2
centre-to-face dimension
CTF
distance between the plane located at the extremity of either body end port and perpendicular to its axis
and the axis of the other body end port
Note 1 to entry: It is applicable to angle pattern valves.
Note 2 to entry: See Figures 1 to 4.
Note 3 to entry: In millimetres.

Key
a face-to-face (FTF)
b centre-to-face (CTF)
Figure 1 — Face to face and centre to face dimensions

Type A Type B
Key
a face-to-face (FTF)
Figure 2 — Flanged valves PN and Class designated (flat and raised faces)
Type C Type D Type E Type F Type G Type H
Key
a face-to-face (FTF)
Figure 3 — Flanged valves PN designated (other types)

Class 150 and Class 300 Class 600 and above
Large
or
small
male
face
Large
or
small
female
face
Large
or
small
tongue
Large
or
small
groove
Key
a for dimensions see Tables 5 to 31
b face-to-face (FTF)
c centre-to-face (CTF)
e height
NOTE For height e, see EN 1759 series.
Figure 4 — Flanged valves Class designated (other types)
4 Dimensions and tolerances
4.1 Basic series
The basic series of FTF and CTF dimensions shall be as given in Tables 5 to 31.
In those tables, there are several series which are non-preferred, but represent history and commercial
decisions made by manufacturers utilizing only one pattern for PN and Class designated valves. Those
series are identified in the relevant tables.
4.2 Face-to-face and centre-to-face dimensions
4.2.1 General
The FTF and CTF dimensions shall be in accordance with Figures 1 to 4.
For each type of valve, the basic series to be taken into consideration are given in Tables 5 to 31.
Table 1 associates the Tables 5 to 31 of the present document with the product standards of industrial
valves. In Table 5 to Table 31, the dimensions may not be given for all values of DN. For certain
sizes/types of valves, alternative dimensions are permitted and these are specified in Table 5 to
Table 31 as appropriate. The origin of the basic series is shown in Annex A.
Table 1 — Correspondence between the FTF series tables of valve types and the product
standards
Product standard
Table numbers Designation
number
EN 1171 Industrial valves — Cast iron gate valves
5, 6 EN 1984 Industrial valves — Steel gate valves
EN 12288 Industrial valves — Copper alloy gate valves
Industrial valves — Metallic butterfly valves for
7, 8, 9, 10 EN 593
general purposes
11, 12 EN 1983 Industrial valves — Steel ball valves
Industrial valves — Diaphragm valves made of
13 EN 13397
metallic materials
EN 13789 Industrial valves — Cast iron globe valves
14, 15, 16, 17
Industrial valves — Steel globe and globe stop and
EN 13709
check valves
18, 19, 20, 21 EN 16767 Industrial valves — Metallic check valves
22, 23, 24, 25, 26, 27,
EN 1349 Industrial process control valves
28, 29
30, 31 EN 26704 Automatic steam traps — Classification
4.2.2 Class designated valves with ring joint flanges
For Class designated valves with ring joint flanges, the FTF or CTF dimensions given in Tables 6, 8, 10, 12,
15, 17, 19, 21, 23, 25, 27, 29 shall be increased by x as defined in Table 2 and Figure 5.
a)
b)
Key
a FTF = Dimension of Tables 6, 8, 10, 12, 15, 19, 21, 23, 27, 29 + x
b CTF= Dimension of Tables 17, 25 + 0.5x
Figure 5 — FTF and CTF dimensions for Class designated valves with ring joint flanges
Table 2 — Additional length x for ring joint flanges
Dimensions in millimetres
Nominal
Additional length x for ring joint flanges
size
DN Class 150 Class 300 Class 600 Class 900 Class 1 500 Class 2 500
15 11,1 11,1 −1,6
20 0
25 0 0
12,7 0
40 3,2
6,4
80 3,2
100 9,5
125 3,2
12,7 12,7
150 6,4
15,9 3,2
200 15,9
9,5
22,2
300 15,9
350 19,1
9,5
450 22,2
12,7
500 19,1 6,4
600 22,2 9,5 19,1 28,6

25,4 12,7
800 — — —
900 28,6 15,9
1 000
4.2.3 Valves with lining
For valves having a resilient lining which forms the gasket joint with the mating flanges, the FTF and CTF
dimensions shall be the distance between the extremities of the valve in the installed condition. If the
dimensions for CTF and FTF differ from the standard dimensions, they shall be given by the manufacturer.
For valves having a hard lining, the thickness of the lining on the mating surface shall be included in the
FTF and CTF dimensions given in Tables 5 to 31, unless the design of the valve precludes such an
inclusion.
If this is the case, the manufacturer shall indicate the deviation from the standardized FTF or CTF
dimensions in his documentation.
4.2.4 Raised face flanges
The raised face dimensions shall be in accordance with the applicable flange standard.
4.3 Tolerances
Tolerances on FTF and CTF dimensions are given in Table 3. Both tolerances shall be fulfilled.
End flange seating surfaces shall be parallel or perpendicular. Tolerances “c” on the parallelism or
perpendicularity as shown in Figure 6 are given in Table 4.

Figure 6 — Tolerances on parallelism and perpendicularity
Table 3 — Tolerances of the FTF or CTF dimensions
Dimensions in millimetres
FTF or CTF dimensions Tolerances
0 to 250 ±2
> 250 to 500 ±3
> 500 to 800 ±4
> 800 to 1 000 ±5
> 1 000 to 1 600 ±6
> 1 600 to 2 250 ±8
Table 4 — Tolerances of parallelism or perpendicularity
Dimensions in millimetres
DN Tolerances
10 to 25 0,4
32 to 150 0,6
200 to 300 0,8
350 to 500 1,0
600 to 800 2,0
1 000 and higher 3,0
Table 5 — Gate valves — PN rating
Dimensions in millimetres
Nominal
Applicable FTF series for the specified pressure designation
size
PN 6 — 10 — PN 6 — 10 — 16 — PN 25 — 40 — PN 160 — PN 250 —
16 25 — 40 63 — 100 250 320 — 400
DN
a
3 14 15 26 99 91
10 102 115 — — — —
15 108 115 — — — —
20 117 120 — — — —
25 127 125 120 — — —
32 140 130 140 — — —
40 165 140 240 240 270 310
50 178 150 250 250 300 350
65 190 170 270 290 360 425
80 203 180 280 310 390 470
100 229 190 300 350 450 550
125 254 200 325 400 525 650
150 267 210 350 450 600 750
200 292 230 400 550 750 950
250 330 250 450 650 900 1 150
300 356 270 500 750 1 050 1 350
350 381 290 550 850 1 200 1 550
400 406 310 600 950 1 350 1 750
450 432 330 650 1 050 1 500 1 950
500 457 350 700 1 150 1 650 2 150
600 508 390 800 1 350 — —
700 610 430 900 1 550 — —
750 610 — — — — —
800 660 470 1 000 1 750 — —
900 711 510 1 100 1 950 — —
1 000 813 550 1 200 2 150 — —
1 050 — — — — — —
1 200 — 630 — — — —
Nominal
Applicable FTF series for the specified pressure designation
size
PN 6 — 10 — PN 6 — 10 — 16 — PN 25 — 40 — PN 160 — PN 250 —
16 25 — 40 63 — 100 250 320 — 400
DN
a
14 15 26 99 91
1 400 — 710 — — — —
1 600 — 790 — — — —
1 800 — 870 — — — —
2 000 — 950 — — — —
a
Non-preferred.
Table 6 — Gate valves — Class rating
Dimensions in millimetres
Nominal Applicable FTF Series for the specified pressure designation
size
Class 125 — Class Class Class Class Class Class
150 250 300 600 900 1 500 2 500
DN
3 19 4 5 54 55 56
10 102 — — — — — —
15 108 — 140 165 — 216 264
20 117 — 152 190 229 229 273
25 127 — 165 216 254 254 308
32 140 — 178 229 279 279 349
40 165 — 190 241 305 305 384
50 178 216 216 292 368 368 451
65 190 241 241 330 419 419 508
80 203 283 283 356 381 470 578
100 229 305 305 432 457 546 673
125 254 381 381 508 551 673 794
150 267 403 403 559 610 705 914
200 292 419 419 660 737 832 1 022
250 330 457 457 787 838 991 1 270
300 356 502 502 838 965 1 130 1 422
350 381 572 762 889 1 029 1 257 —
400 406 610 838 991 1 130 1 384 —
450 432 660 914 1 092 1 219 1 537 —
500 457 711 991 1 194 1 321 1 664 —
600 508 787 1 143 1 397 1 549 1 943 —
700 610 — 1 346 1 549 — — —
750 610 — 1 397 1 651 — — —
800 660 — 1 524 1 651 — — —
900 711 — 1 727 2 083 — — —
1 000 813 — — — — — —
Table 7 — Butterfly valves and butterfly control valves — Flanged type — PN rating
Dimensions in millimetres
Nominal size Applicable FTF Series for the specified pressure designation
PN 2,5 — 6 — 10 — 16 — 25 — 40
DN
13 14
20 — 120
25 — 125
32 — 130
40 106 140
50 108 150
65 112 170
80 114 180
100 127 190
125 140 200
150 140 210
200 152 230
250 165 250
300 178 270
350 190 290
400 216 310
450 222 330
500 229 350
600 267 390
700 292 430
750 — —
800 318 470
900 330 510
1 000 410 550
1 050 — —
1 200 470 630
1 400 530 710
1 600 600 790
1 800 670 870
2 000 760 950
Table 8 — Butterfly valves and butterfly control valves — Flanged type — Class rating
Dimensions in millimetres
Nominal
Applicable FTF Series for the specified pressure designation
size
Class 125 — 150 Class 250 — 300 Class 600
DN
13 14 16 20 25 14 16 25 14
20 — 120 — 33 — 120 — — 120
25 — 125 — 33 — 125 — — 125
32 — 130 — 33 — 130 — — 130
40 106 140 33 33 — 140 33 — 140
50 108 150 43 43 — 150 43 — 150
65 112 170 46 46 — 170 46 — 170
80 114 180 64 46 49 180 64 49 180
100 127 190 64 52 56 190 64 56 190
125 140 200 70 56 64 200 70 64 200
150 140 210 76 56 70 210 76 70 210
200 152 230 89 60 71 230 89 71 230
250 165 250 114 68 76 250 114 76 250
300 178 270 114 78 83 270 114 83 270
350 190 290 127 78 92 92 290 127 92 290
400 216 310 140 102 102 310 140 102 310
450 222 330 152 114 114 330 152 114 330
500 229 350 152 127 127 350 152 127 350
600 267 390 178 154 154 390 178 154 390
700 292 430 229 165 — 430 229 — 430
750 — — 165 165 190 — — — — —
800 318 470 241 190 — 470 241 — 470
900 330 510 241 200 203 — 510 — — 510
1 000 410 550 300 251 216 — 550 — — 550
1 050 — — — — — — — — —
1 200 470 630 350 276 — — 630 — — 630
1 400 530 710 390 279 — 710 390 — 710
1 600 600 790 440 318 — 790 440 — 790
1 800 670 870 490 356 — 870 490 — 870
2 000 760 950 540 406 — 950 540 — 950
Table 9 — Butterfly valves and butterfly control valves — Wafer type — PN rating
Dimensions in millimetres
Nominal size Applicable FTF Series for the specified pressure designation
PN 2,5 — 6 PN 10 — 16 — 25 — 40
DN
a
25 20
16 25
20 33 — — 33 —
25 33 — — 33 —
32 33 — — 33 —
40 33 37 33 33 37
50 43 44 43 43 44
65 46 49 46 46 49
80 46 49 64 46 49
100 52 56 64 52 56
125 56 64 70 56 64
150 56 70 76 56 70
200 60 71 89 60 71
250 68 76 114 68 76
300 78 83 114 78 83
350 78 92 127 78 92
400 102 102 140 102 102
450 114 114 152 114 114
500 127 127 152 127 127
600 154 154 178 154 154
700 165 — 229 165 —
750 190 165 230 190 165
800 190 — 241 190 —
900 203 200 241 203 200
1 000 216 — 300 216 —
1 050 — 251 — — 251
1 200 254 276 350 254 276
1 400 279 — 390 279 —
1 600 318 — 440 318 —
1 800 356 — 490 356 —
2 000 406 — 540 406 —
a
Non-preferred.
Table 10 — Butterfly valves and butterfly control valves — Wafer type — Class rating
Dimensions in millimetres
Nominal Applicable FTF Series for the specified pressure designation
size
a a
Class 600
Class 125 — 150 Class 250 — 300
DN
16 20 25 16 25 109 110
20 — 33 — — — — —
25 — 33 — — — — —
32 — 33 — — — — —
40 — 33 37 — 37 — —
50 43 43 44 43 44 — —
65 46 46 49 46 49 — —
80 64 46 49 64 49 48 54
100 64 52 56 64 56 54 64
125 70 56 64 70 64 — —
150 76 56 70 76 70 59 78
200 89 60 71 89 71 73 102
250 114 68 76 114 76 83 117
300 114 78 83 114 83 92 140
350 127 78 92 127 92 117 155
400 140 102 102 140 102 133 178
450 152 114 114 152 114 149 200
500 152 127 127 152 127 159 216
600 178 154 154 178 154 181 232
700 229 165 — 229 — — —
750 230 190 165 230 165 — —
800 241 190 — 241 — — —
900 241 203 200 241 200 — —
1 000 300 216 — 300 — — —
1 050 — — 251 — 251 — —
1 200 350 254 276 350 276 — —
1 400 390 279 — 390 — — —
1 600 440 318 — 440 — — —
1 800 490 356 — 490 — — —
2 000 540 406 — 540 — — —
a
Class 125 and Class 250 butterfly control valves wafer type are excluded from the scope of EN 1349.
Table 11 — Ball and plug valves — PN rating
Dimensions in millimetres
Nominal
Applicable FTF Series for the specified pressure designation
size
PN 63 —
PN 6 — 10 — 16 PN 25 — 40
DN
1 12 26 27 1 4 12 26 27 28
10 130 130 — 115 130 — 130 — 115
15 130 130 — 115 130 140 130 — 115
20 150 130 — 120 150 152 130 — 120
25 160 140 — 125 160 165 140 — 125
32 180 165 — 130 180 178 165 — 130
40 200 165 240 140 200 190 165 240 140
50 230 203 250 150 230 216 203 250 150
65 290 222 290 170 290 241 222 290 170
80 310 241 310 180 310 283 241 310 180
100 350 305 350 190 350 305 305 350 190
125 400 356 400 325 400 381 356 400 325
150 480 394 450 350 480 403 394 450 350
200 600 457 550 400 600 419 457 550 400
250 730 533 650 450 730 457 533 650 450
300 850 610 750 500 850 502 610 750 500
350 980 686 850 550 980 762 686 850 550
400 1 100 762 950 762 1 100 838 762 950 762
450 1 200 864 1 050 — 1 200 914 864 1 050 — —
1 150
500 1 250 914 1 150 914 1 250 991 914 1 150 914
600 1 450 1 067 1 350 — 1 450 1 143 1 067 1 350 — —
700 1 650 — 1 550 — 1 650 1 346 — 1 550 — —
750 — — — — — 1 397 — — — —
800 1 850 — 1 750 — 1 850 1 524 — 1 750 — —
900 2 050 — 1 950 — 2 050 1 727 — 1 950 — —
1 000 2 250 — 2 150 — 2 250 — — 2 150 — —
Table 12 — Ball and plug valves — Class rating
Dimensions in millimetres
a
Nominal
Applicable FTF Series for the specified pressure designation
size
Class 125 — 150 Class 250 — 300 Class 600 Class 900
DN
1 12 1 4 5 54
10 130 130 130 — — —
15 130 130 130 140 165 —
20 150 130 150 152 190 229
25 160 140 160 165 216 254
32 180 165 180 178 229 279
40 200 165 200 190 241 305
50 230 203 230 216 292 368
65 290 222 290 241 330 419
80 310 241 310 283 356 381
100 350 305 350 305 432 457
125 400 356 400 381 508 559
150 480 394 480 403 559 610
b
200 600 457 600 660 737
c
250 730 533 730 787
d
300 850 610 850 838 965
350 980 686 980 762 889 1 029
400 1 100 762 1 100 838 991 1 130
450 1 200 864 1 200 914 1 092 1 219
500 1 250 914 1 250 991 1 194 1 321
600 1 450 1 067 1 450 1 143 1 397 1 549
700 1 650 — 1 650 1 346 1 549 —
750 — — — 1 397 1 651 —
800 1 850 — 1 850 1 524 1 778 —
900 2 050 — 2 050 1 727 2 083 —
1 000 2 250 — 2 250 — — —
a
All dimensions can be used for plug valves with the agreement of the purchaser.
b
For full bore ball valves, use 502.
c
For full bore ball valves, use 568.
d
For full bore ball valves, use 648.
Table 13 — Diaphragm valves
Dimensions in millimetres
Nominal size Applicable FTF Series for the specified pressure designation
Class 125 —
PN 10 — 16 —
PN 6 — 10 — 16 Class 125 — 150 150 — 250 —
25 — 40
DN
7 1 1 7
10 108 130 130 108
15 108 130 130 108
20 117 150 150 117
25 127 160 160 127
32 146 180 180 146
40 159 200 200 159
50 190 230 230 190
65 216 290 290 216
80 254 310 310 254
100 305 350 350 305
125 356 400 400 356
150 406 480 480 406
200 521 600 600 521
250 635 730 730 635
a a
300 749 850 850 749
a
Also used for DN 350, DN 400, DN 450 and DN 500.
Table 14 — Globe valves — Straight and oblique pattern — PN rating
Dimensions in millimetres
Nominal size Applicable FTF Series for the specified pressure designation
PN 63 — 100 — PN 250 —
PN 6 — 10 — 16 PN 25 — 40
160 320 — 400
DN
1 14 125 1 125 2 92
10 130 115 — 130 — 210 230
15 130 115 — 130 — 210 230
20 150 120 — 150 — 230 260
25 160 125 — 160 — 230 260
32 180 130 — 180 — 260 300
40 200 140 — 200 — 260 300
50 230 150 — 230 — 300 350
65 290 170 — 290 — 340 400
80 310 180 — 310 — 380 450
100 350 190 300 350 300 430 520
125 400 200 325 400 325 500 600
150 480 210 350 480 350 550 700
200 600 230 400 600 400 650 800
250 730 250 450 730 450 775 900
300 850 270 500 850 500 900 1 050
350 980 290 550 980 550 1 025 —
400 1 100 310 600 1 100 600 1 150 —
450 1 200 330 650 1 200 650 1 275 —
500 1 250 350 750 1 250 750 1 400 —
600 1 450 390 900 1 450 900 1 600 —
700 1 650 430 1 050 1 650 1 050 — —
750 — — — — — — —
800 1 850 470 1 200 1 850 1 200 — —
900 2 050 510 1 350 2 050 1 350 — —
1 000 2 250 550 1 500 2 250 1 500 — —
1 050 — — — — — — —
1 200 — 630 1 800 — 1 800 — —
1 400 — 710 2 100 — 2 100 — —
1 600 — 790 2 500 — 2 500 — —
1 800 — 870 2 700 — 2 700 — —
2 000 — 950 3 000 — 3 000 — —
Table 15 — Globe valves — Straight and oblique pattern — Class rating
Dimensions in millimetres
Nominal
Applicable FTF Series for the specified pressure designation
size
Class 250 —
Class 125 — 150 Class 600 Class 900 Class 1 500 Class 2 500
DN
a
1 10 1 21 5 54 55 56
10 130 — 130 — — — — —
15 130 108 130 152 165 — 216 264
20 150 117 150 178 190 229 229 273
25 160 127 160 203 216 254 254 308
32 180 140 180 216 229 279 279 349
40 200 165 200 229 241 305 305 384
50 230 203 230 267 292 368 368 451
65 290 216 290 292 330 419 419 508
80 310 241 310 318 356 381 470 578
100 350 292 350 356 432 457 546 673
125 400 356 400 400 508 551 673 794
150 480 406 480 444 559 610 705 914
200 600 495 600 559 660 737 832 1 022
250 730 622 730 622 787 838 991 1 270
300 850 698 850 711 838 965 1 130 1 422
350 980 787 980 — 889 1 029 1 257 —
400 1 100 914 1 100 — 991 1 130 1 384 —
450 1 200 — 1 200 — 1 092 1 219 1 537 —
500 1 250 — 1 250 — 1 194 1 321 1 664 —
600 1 450 — 1 450 — 1 397 1 549 1 943 —
700 1 650 — 1 650 — 1 549 — — —
750 — — — — 1 651 — — —
800 1 850 — 1 850 — 1 651 — — —
900 2 050 — 2 050 — 2 083 — — —
1 000 2 250 — 2 250 — — — — —
a
Non-preferred.
Table 16 — Globe valves and lift check valves — Angle pattern — PN rating
Dimensions in millimetres
Nominal
Applicable CTF Series for the specified pressure designation (EN 16767)
size
PN 63 — 100 — PN 250 — 320 —
PN 6 PN 10 — 16 — 25 — 40
160 400
DN
a a a a
22 23 8 22 23 9 93
10 65 70 90 65
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.