FprEN 12016
(Main)Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity
1.1 This document specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements.
This document refers to EM conditions as existing in residential, office and industrial buildings.
This document addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer.
However:
- performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence;
- this document does not apply to other apparatus already proven to be in conformity to the EMC Directive, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc.
1.2 This document does not apply to electromagnetic environments such as:
- radio-transmitter stations,
- railways and metros,
- heavy industrial plant,
- electricity power station,
which need additional investigations.
1.3 This document is not applicable to apparatus which were manufactured before the date of its publication as EN 12016.
Elektromagnetische Verträglichkeit - Produktfamilien-Norm für Aufzüge, Fahrtreppen und Fahrsteige - Störfestigkeit
1.1 Diese Europäische Norm legt die Bewertungskriterien und Prüfschärfegrade für Aufzüge, Fahrtreppen und Fahrsteige fest, die zum dauerhaften Einbau in Gebäuden vorgesehen sind, einschließlich der grundlegenden Sicherheitsanforderungen im Hinblick auf ihre elektromagnetische Umgebung. Diese Prüfschärfegrade stellen wesentliche EMV-Anforderungen dar.
Die Norm erstreckt sich auf elektromagnetische Umgebungsbedingungen, wie sie in Wohn-, Büro- und Industriegebäuden vorliegen.
Diese Norm behandelt allgemein bekannte EMV-relevante Gefährdungen und Gefährdungssituationen, die auf Aufzüge, Fahrtreppen und Fahrsteige zutreffen, wenn sie bestimmungsgemäß und entsprechend den vom Montagebetrieb des Aufzugs oder dem Hersteller der Fahrtreppe und/oder des Fahrsteigs vorgesehenen Bedingungen verwendet werden.
Jedoch:
- decken Prüfschärfegrade und Bewertungskriterien für Baugruppe/Baugruppenkombination, die in allgemeinen Funktionsbaugruppen eingesetzt werden, keine Situationen ab, die nur mit einer äußerst geringen Wahrscheinlichkeit eintreten;
- bezieht sich diese Norm nicht auf andere Baugruppen, die bereits auf Konformität mit der EMV-Richtlinie geprüft sind und keinen Bezug zur Sicherheit des Aufzugs, der Fahrtreppe oder des Fahrsteigs aufweisen, wie z. B. Beleuchtungs- und Kommunikationseinrichtungen.
1.2 Diese Europäische Norm gilt nicht für elektromagnetische Umgebungen, wie bei:
- Rundfunksendern;
- Eisen- und Untergrundbahnen;
- Anlagen der Schwerindustrie;
- Kraftwerken;
die zusätzliche Untersuchungen erfordern.
1.3 Diese Norm gilt nicht für Baugruppen, die vor deren Veröffentlichung als EN 12016 hergestellt wurden.
Compatibilité électromagnétique - Norme de la famille de produits ascenseurs, escaliers mécaniques et trottoirs roulants - Immunité
1.1 La présente Norme européenne définit les critères d’aptitude et les niveaux d’essai d’immunité pour les appareillages utilisés dans les ascenseurs, escaliers mécaniques et trottoirs roulants qui sont destinés à être installés de façon permanente dans des bâtiments, y compris les exigences de base relatives à la sécurité de leur environnement électromagnétique. Ces niveaux représentent les exigences essentielles en matière de compatibilité électromagnétique (CEM).
La présente norme s’applique aux conditions électromagnétiques rencontrées dans les bâtiments d’habitation, les bureaux et les établissements industriels.
La présente norme aborde les risques et les situations dangereuses connus en matière de CEM, rencontrés lorsque les ascenseurs, escaliers mécaniques et trottoirs roulants sont utilisés conformément à l’usage prévu et dans les conditions prévues par l’installateur de l’ascenseur ou par le fabricant de l’escalier mécanique et/ou du trottoir roulant.
Cependant :
- les critères d’aptitude et les niveaux d’essai des appareillages/ensembles d’appareillages utilisés dans des circuits à fonction générale ne couvrent pas les situations à très faible probabilité d’occurrence ;
- la présente norme ne s’applique pas aux autres appareillages dont la conformité à la Directive CEM est déjà établie, et qui n’ont pas de rapport avec la sécurité de l’ascenseur, de l’escalier mécanique ou du trottoir roulant, tels que les appareils d’éclairage, les appareils de communication, etc.
1.2 La présente Norme européenne ne s’applique pas aux environnements électromagnétiques tels que :
- les émetteurs de radiodiffusion ;
- les chemins de fer et métros ;
- les installations d’industrie lourde ;
- les centrales électriques ;
qui nécessitent des études supplémentaires.
1.3 La présente norme ne s’applique pas aux appareils fabriqués avant sa date de publication en tant qu’EN 12016.
Elektromagnetna združljivost - Standard skupine izdelkov za dvigala (lifte), tekoče stopnice in tekoče steze - Odpornost proti motnjam
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 12016:2018
01-marec-2018
(OHNWURPDJQHWQD]GUXåOMLYRVW6WDQGDUGVNXSLQHL]GHONRY]DGYLJDODOLIWHWHNRþH
VWRSQLFHLQWHNRþHVWH]H2GSRUQRVWSURWLPRWQMDP
Electromagnetic compatibility - Product family standard for lifts, escalators and moving
walks - Immunity
Elektromagnetische Verträglichkeit - Produktfamilien-Norm für Aufzüge, Fahrtreppen und
Fahrsteige - Störfestigkeit
Compatibilité électromagnétique - Norme de la famille de produits ascenseurs, escaliers
mécaniques et trottoirs roulants - Immunité
Ta slovenski standard je istoveten z: prEN 12016
ICS:
33.100.20 Imunost Immunity
91.140.90 'YLJDOD7HNRþHVWRSQLFH Lifts. Escalators
oSIST prEN 12016:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
oSIST prEN 12016:2018
oSIST prEN 12016:2018
DRAFT
EUROPEAN STANDARD
prEN 12016
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2018
ICS 33.100.20; 91.140.90 Will supersede EN 12016:2013
English Version
Electromagnetic compatibility - Product family standard
for lifts, escalators and moving walks - Immunity
Compatibilité électromagnétique - Norme de la famille Elektromagnetische Verträglichkeit - Produktfamilien-
de produits ascenseurs, escaliers mécaniques et Norm für Aufzüge, Fahrtreppen und Fahrsteige -
trottoirs roulants - Immunité Störfestigkeit
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 10.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 12016:2018 E
worldwide for CEN national Members.
oSIST prEN 12016:2018
prEN 12016:2018 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 Test procedure . 10
5 Applicability of tests. 11
6 Evaluation of tests results . 12
6.1 Introduction . 12
6.2 Performance criteria . 12
6.3 Enclosure ports of safety circuits . 12
7 Documentation for the installer of the apparatus/assembly of apparatus . 13
Annex ZA (informative) Relationship between this European standard and the essential
requirements of Directive 2014/30/EU aimed to be covered . 21
Annex ZB (informative) Relationship between this European Standard and the essential
requirements of Directive 2006/42/EC aimed to be covered . 22
Annex ZC (informative) Relationship between this European Standard and the essential
requirements of Directive 2014/33/EU aimed to be covered . 23
Bibliography . 24
oSIST prEN 12016:2018
prEN 12016:2018 (E)
European foreword
This document (prEN 12016:2018) has been prepared by Technical Committee CEN/TC 10 “Lifts,
escalators and moving walks”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 12016:2013.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annexes ZA, ZB and ZC, which are an integral part
of this document.
The test levels and the performance criteria which are given in this European Standard reflect the fact
that lifts, escalators and moving walks, when in use, consist generally of self-contained apparatus (e.g.
machine room, car, etc.).
The related EMC product family standard for emission is:
— EN 12015, Electromagnetic compatibility — Product family standard for lifts, escalators and moving
walks — Emission
oSIST prEN 12016:2018
prEN 12016:2018 (E)
Introduction
This document is a Type C standard as stated in EN ISO 12100.
This document has been prepared to provide one means of conforming to the requirements of the
Electromagnetic Compatibility (EMC) Directive, the Lifts Directive and the Machinery Directive. The
requirements of this European Standard have been specified so as to ensure an adequate level of
electromagnetic immunity for most cases.
The apparatus concerned and the extent to which hazards, hazardous situations or hazardous events
are covered are indicated in the Scope of this document.
When requirements of this type C standard are different from those which are stated in type-A or type-
B standards, the requirements of this type C standard take precedence over the requirements of the
other standards for apparatus that have been designed and built according to the requirements of this
type C standard.
Test levels and immunity performance criteria are defined for:
— apparatus which are safety components or are used in conjunction with safety components, (safety
circuits);
— apparatus used in general function circuits.
The test levels and requirements are given on the basis that the apparatus, generally, is connected to a
low voltage system.
The requirements for safety circuits provide one means of demonstrating conformity with the essential
health and safety requirements of the Lifts Directive and the Machinery Directive with regard to
immunity against electromagnetic phenomena.
Due to the size of an installed lift, it becomes impracticable to test the total assembly either in a test
laboratory or in situ where the uncontrolled environment may also influence the test procedures and
results. This applies also to measurements within the car. Similar considerations regarding dimensions
apply equally to the testing of escalators and moving walks.
Rational to the revision of the standard EN 12016:1998
a) Important changes
The Scope excludes severe electromagnetic environments and apparatus already proven to be in
conformity with the Electromagnetic Compatibility Directive.
The term “installation” has been changed to “system”. This is due to the fact that official interpretation
defines that fixed installations are not covered by the conformity assessment procedures for CE
marking and declaration of conformity according to the EMC Directive. The scope of the standard is
applicable to the apparatus and assembly of apparatus of lifts and escalators and assembly into systems.
New requirements on radio frequency electromagnetic field above 500 MHz, these are extended to
cover the digital mobile telephone services up to 1960 MHz.
New requirements for surge testing on safety circuits.
New requirements on radio frequency electromagnetic field regarding safety devices as defined by the
Lifts Directive and mobile telephones or radio-transmitters as a result of a risk assessment. It is
assumed that mobile telephones and radio-transmitters are not used at frequencies up to 166 MHz near
safety circuits of equipment covered by the scope of this standard.
Higher requirements on several environmental phenomena considering the progress on EMC
technology and the results of the risk assessment.
oSIST prEN 12016:2018
prEN 12016:2018 (E)
New requirements have been introduced for immunity to mains power supply voltage interruptions
and voltage dips.
b) Environmental issues
Lifts, escalators and moving walks are systems whose component apparatus/assembly of apparatus are
distributed (and some of which move) throughout the building. The definition in EMC terms of the use
of the building (residential or industrial) cannot be predetermined or assumed to be fixed. Therefore, to
cover requirements in all cases, no differentiation between environments has been made and a single
set of limits has been maintained.
Severe electromagnetic environments have not been considered. Examples of these are: radio-
transmitter stations, railways and metros, heavy industrial plant, electricity power stations. Additional
tests and immunity measures may need to be taken on apparatus to be used in these environments.
It is assumed that no ports connected to safety circuit only are rated at currents greater than 100 A.
Rational to the revision of the standard EN 12016:2004+A1:2008
New requirements on radio frequency electromagnetic field to cover the digital mobile telephone
services and wireless communication systems up to 2 655 MHz.
Performance criteria requirements for radio equipment and telecommunications terminal equipment
as defined by Directive 1999/5/EC used in combined apparatus/assembly of apparatus.
Rational to the revision of the standard EN 12016:2013
Relationship between this European Standard and EN 81-20.
Relationship between this European Standard and the essential requirements of EU Directive
2014/30/EU.
Relationship between this European Standard and the essential requirements of Directive 2006/42/EC.
Relationship between this European Standard and the essential requirements of Directive 2014/33/EU.
oSIST prEN 12016:2018
prEN 12016:2018 (E)
1 Scope
1.1 This document specifies the immunity performance criteria and test levels for apparatus used in
lifts, escalators and moving walks which are intended to be permanently installed in buildings including
the basic safety requirements in regard to their electromagnetic environment. These levels represent
essential EMC requirements.
This document refers to EM conditions as existing in residential, office and industrial buildings.
This document addresses commonly known EMC related hazards and hazardous situations relevant to
lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by
the lift installer or escalator and/or moving walk manufacturer.
However:
— performance criteria and test levels for apparatus/assembly of apparatus used in general function
circuits do not cover situations with an extremely low probability of occurrence;
— this document does not apply to other apparatus already proven to be in conformity to the EMC
Directive, and not related to the safety of the lift, escalator or moving walk, such as lighting
apparatus, communication apparatus, etc.
1.2 This document does not apply to electromagnetic environments such as:
— radio-transmitter stations,
— railways and metros,
— heavy industrial plant,
— electricity power station,
which need additional investigations.
1.3 This document is not applicable to apparatus which were manufactured before the date of its
publication as EN 12016.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 55022:2010, Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement (CISPR 22:2008, modified)
EN 55024:2010, Information technology equipment - Immunity characteristics - Limits and methods of
measurement (CISPR 24:2010)
EN 61000-4-2:2009, Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity test (IEC 61000-4-2:2008)
oSIST prEN 12016:2018
prEN 12016:2018 (E)
EN 61000-4-3:2
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.