Health and safety in welding and allied processes - Laboratory method for sampling fume and gases generated by arc welding - Part 2: Determination of emission rates of gases, except ozone (ISO 15011-2:2003)

This standard provides guidance on the determination of emission rates of gases generated by arc welding using a fume box technique. It describes the test principle, gives a possible fume box arrangement and considers methods for sampling and analysis.
The following gases that can be produced during arc welding are covered:
- Carbon monoxide (C0);
- Carbon dioxide (C02);
- Nitrogen oxide (NO);
- Nitrogen dioxide (N02).
The fume box described in this standard may also be used for the determination of organic gases produced in the arc welding of coated metals, e.g. primed, painted or plastic coated material (see annex A for further information).
Ozone is considered in prEN ISO 15011-3.

Arbeits- und Gesundheitsschutz beim Schweißen und bei verwandten Verfahren - Laborverfahren zum Sammeln von Rauch und Gasen, die beim Lichtbogenschweißen erzeugt werden - Teil 2: Bestimmung der Emissionsrate von Gasen, außer Ozon (ISO 15011-2:2003)

Diese Norm vermittelt einen Leitfaden zur Bestimmung der Emissionsraten von Gasen und organischen Dämpfen, die beim Lichtbogenschweißen erzeugt werden, durch Anwendung einer Rauchkammertechnik. Sie beschreibt die Prüfungs- grunsätze, gibt Beispiele für die Anordnung der Rauchkammern und beschreibt Verfahren zur Probenahme und Analyse.

Hygiène et sécurité en soudage et techniques connexes - Méthode de laboratoire d'échantillonnage des fumées et des gaz émis par le soudage à l'arc - Partie 2: Détermination du taux d'émission des gaz, à l'exception de l'ozone (ISO 15011-2:2003)

La présente norme constitue un guide pour la détermination des taux d'émission des gaz et des vapeurs organiques généris par le soudage à l'arc, en utilisant la technique de la chambre de prélèvement. Elle décrit le principe d'essai, fournit un exemple de conception de chambre de prélèvement et propose des méthodes d'échantillonnage et d'analyse.

Zdravje in varnost pri varjenju in sorodnih postopkih - Laboratorijska metoda za vzorčenje dima in plinov, nastalih pri obločnem varjenju - 2. del: Določevanje količine sproščenih plinov, razen ozona (ISO 15011-2:2003)

General Information

Status
Withdrawn
Publication Date
30-Apr-2003
Withdrawal Date
14-Oct-2009
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Oct-2009
Completion Date
15-Oct-2009

Relations

Buy Standard

Standard
EN ISO 15011-2:2003
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 15011-2:2003
01-december-2003
=GUDYMHLQYDUQRVWSULYDUMHQMXLQVRURGQLKSRVWRSNLK/DERUDWRULMVNDPHWRGD]D
Y]RUþHQMHGLPDLQSOLQRYQDVWDOLKSULREORþQHPYDUMHQMXGHO'RORþHYDQMH
NROLþLQHVSURãþHQLKSOLQRYUD]HQR]RQD ,62
Health and safety in welding and allied processes - Laboratory method for sampling fume
and gases generated by arc welding - Part 2: Determination of emission rates of gases,
except ozone (ISO 15011-2:2003)
Arbeits- und Gesundheitsschutz beim Schweißen und bei verwandten Verfahren -
Laborverfahren zum Sammeln von Rauch und Gasen, die beim Lichtbogenschweißen
erzeugt werden - Teil 2: Bestimmung der Emissionsrate von Gasen, außer Ozon (ISO
15011-2:2003)
Hygiene et sécurité en soudage et techniques connexes - Méthode de laboratoire
d'échantillonnage des fumées et des gaz émis par le soudage a l'arc - Partie 2:
Détermination du taux d'émission des gaz, a l'exception de l'ozone (ISO 15011-2:2003)
Ta slovenski standard je istoveten z: EN ISO 15011-2:2003
ICS:
13.100 Varnost pri delu. Industrijska Occupational safety.
higiena Industrial hygiene
25.160.10 Varilni postopki in varjenje Welding processes
SIST EN ISO 15011-2:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 15011-2:2003

---------------------- Page: 2 ----------------------

SIST EN ISO 15011-2:2003
EUROPEAN STANDARD
EN ISO 15011-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2003
ICS 13.040.40; 25.160.10
English version
Health and safety in welding and allied processes - Laboratory
method for sampling fume and gases generated by arc welding -
Part 2: Determination of emission rates of gases, except ozone
(ISO 15011-2:2003)
Hygiène et sécurité en soudage et techniques connexes - Arbeits- und Gesundheitsschutz beim Schweißen und bei
Méthode de laboratoire d'échantillonnage des fumées et verwandten Verfahren - Laborverfahren zum Sammeln von
des gaz émis par le soudage à l'arc - Partie 2: Rauch und Gasen, die beim Lichtbogenschweißen erzeugt
Détermination du taux d'émission des gaz, à l'exception de werden - Teil 2: Bestimmung der Emissionsrate von
l'ozone (ISO 15011-2:2003) Gasen, außer Ozon (ISO 15011-2:2003)
This European Standard was approved by CEN on 10 May 2002.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2003 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 15011-2:2003 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 15011-2:2003
EN ISO 15011-2:2003 (E)
Contents
page
Foreword. 3
Introduction . 4
1 Scope. 5
2 Normative references . 5
3 Terms and definitions. 6
4 Principle . 6
5 Measurement methods . 6
5.1 Gases. 6
5.2 Fume box air flow rate . 7
6 Equipment. 7
6.1 Fume box . 7
6.2 Ventilator or pump . 7
7 Sampling . 7
7.1 Sampling position . 7
7.2 Sampling equipment. 7
7.3 Sample filtration . 8
7.4 Multiple sampling. 8
7.5 Volume of sampling line. 8
7.6 Sampling flow rate . 8
7.7 Fume box ventilation air flow rate. 8
7.8 Handling of temperature, pressure and humidity data . 8
8 Measurement of individual gases. 9
8.1 General . 9
8.2 Carbon monoxide. 9
8.3 Carbon dioxide . 9
8.4 Nitrogen oxide and nitrogen dioxide. 9
9 Test report. 10
Annex A (informative) Organic gases. 11
Annex B (informative) Examples of fume box arrangements for determination of emission rates of
gases in arc welding, except ozone . 12
Annex C (informative) Test report. 14
Bibliography . 15
2

---------------------- Page: 4 ----------------------

SIST EN ISO 15011-2:2003
EN ISO 15011-2:2003 (E)
Foreword
The text of EN ISO 15011-2:2003 has been prepared by Technical Committee CEN/TC 121 "Welding", the
secretariat of which is held by DS, in collaboration with Technical Committee ISO/TC 44 “Welding and allied
processes”.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by November 2003, and conflicting national standards shall be withdrawn at the latest
by November 2003.
This standard consists of the following parts:
- Part 1: Determination of emission rate and sampling for analysis of particulate fume;
- Part 2: Determination of emission rates of gases and vapours, except ozone;
- Part 3: Determination of ozone concentration using fixed point measurements.
The annexes A, B and C are informative.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,
Slovakia, Spain, Sweden, Switzerland and the United Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN ISO 15011-2:2003
EN ISO 15011-2:2003 (E)
Introduction
Welding and allied processes produce airborne particles and gaseous by-products, which can be harmful to human
health. Knowledge of the quantity and composition of the airborne particles and gases emitted can be useful for
occupational hygienists in assessing workplace atmospheres and in determining appropriate control measures.
Emission rates cannot be used directly to assess the welder's exposure, but it is expected that processes,
consumables and welding parameters giving low emission rates will result in lower welder exposures than
processes with high emission rates used in the same working situation.
The laboratory procedure described in this standard can be used to determine the emission rate of gases
generated by arc welding and provides a method of sampling the gases for chemical analysis. The gases
generated and their emission rates depend upon the welding process, welding parameters, work piece surface,
coatings, etc.
In the context of this standard emission rate means the total amount of a substance per unit time that is produced
under defined process conditions, by different reactions in the system defined in this standard.
Gases encountered in arc welding are so numerous that it would be impracticable to cover them all in this standard.
The scope of this standard has therefore been limited to those gases, which are commonly generated during arc
welding.
It has been assumed in the drafting of this standard that the executions of its provisions, and the interpretation of
the results obtained, is entrusted to appropriately qualified and experienced people.
4

---------------------- Page: 6 ----------------------

SIST EN ISO 15011-2:2003
EN ISO 15011-2:2003 (E)
1 Scope
This European Standard provides guidance on the determination of emission rates of gases generated by arc
welding using a fume box technique. It describes the test principle, gives a possible fume box arrangement and
considers methods for sampling and analysis.
The following gases that can be produced during arc welding are covered:
- Carbon monoxide (CO);
- Carbon dioxide (CO );
2
- Nitrogen oxide (NO);
- Nitrogen dioxide (NO ).
2
The fume box described in this standard can also be used for the determination of organic gases produced in the
arc welding of coated metals, e.g. primed, painted or plastic coated material (see annex A for further information).
Ozone is considered in EN ISO 15011-3.
2 Normative references
This European Standard incorporates by dated or undated references, provisions from other publications. These
normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For
dated references, subsequent amendments to or revisions of any of these publications apply to this European
Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the
publication referred to applies (including amendments).
EN 482, Workplace atmospheres - General requirements for the performance of procedures for the measurement
of chemical agents.
EN 1076, Workplace atmospheres - Pumped sorbent tubes for the determination of gases and vapours -
Requirements and test methods.
EN 1540, Workplace atmospheres – Terminology.
EN 45544-1, Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration
measurement of toxic gases and vapours – Part 1: General requirements and test methods.
EN ISO 4063, Welding and allied processes — Nomenclature of processes and reference numbers
(ISO 4063:1998).
EN ISO 10882–2, Health and safety in welding and allied processes — Sampling of airborne particles and gases in
the operator's breathing zone — Part 2: Sampling of gases (ISO 10882-2:2000).
ISO 3534–1, Statistics - Vocabulary and symbols - Part 1: Probability and general statistical terms.
ISO 5167–1, Measurements of fluid flow by means of pressure differential devices - Part 1: Orifice plates, nozzles
and Venturi tubes inserted in circular cross sections conduits running full.
ISO 6879, Air quality - Performance characteristics and related concepts for air quality measuring methods.
ISO 8756, Air quality - Handling of temperature, pressure and humidity data.
5

---------------------- Page: 7 ----------------------

SIST EN ISO 15011-2:2003
EN ISO 15011-2:2003 (E)
3 Terms and definitions
For the purposes of this European Standard, the terms and definitions given in EN 1540, ISO 6879,
EN ISO 10882–2, EN 482, EN 1076, ISO 3534–1, EN ISO 4063 and the following apply.
3.1
fume box
closed or semi-closed ventilated chamber used for sampling and determination (emission rate and composition) of
fume and gases in welding and allied processes
4 Principle
Arc welding is performed in
...