Equipment for general lighting purposes - EMC immunity requirements

IEC 61547:2009 for electromagnetic immunity requirements applies to lighting equipment which is within the scope of IEC Technical Committee 34, such as lamps, auxiliaries and luminaires, intended either for connecting to a low voltage electricity supply or for battery operation. Excluded from the scope of this standard is equipment for which the immunity requirements are formulated in other IEC or CISPR standards. The main reason for this revision is to update the dates of the references to the basic standards which also required some editorial changes in the tables.

Einrichtungen für allgemeine Beleuchtungszwecke - EMV-Störfestigkeitsanforderungen

Equipements pour l'éclairage à usage général - Exigences concernant l'immunité CEM

La CEI 61547:2009 concernant les exigences d'immunité électromagnétique s'applique aux appareils d'éclairage entrant dans le domaine d'application du Comité d'études 34 de la CEI, tels que les lampes, les accessoires et les luminaires, destinés à être raccordés au réseau d'alimentation électrique public basse tension ou à fonctionner sur piles. Sont exclus du domaine d'application de la présente norme les équipements pour lesquels les exigences d'immunité sont formulées dans d'autres normes CEI ou CISPR. La raison principale de la présente révision est la mise à jour des dates des références aux normes fondamentales, ce qui a également nécessité certaines modifications rédactionnelles des tableaux.

Oprema za splošno razsvetljavo - Zahteve za odpornost proti EMC (IEC 61547:2009)

General Information

Status
Published
Publication Date
11-Aug-2009
Withdrawal Date
30-Jun-2012
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
12-Aug-2009
Completion Date
12-Aug-2009

Relations

Buy Standard

Standard
EN 61547:2009
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2009
1DGRPHãþD
SIST EN 61547:1996
SIST EN 61547:1996/A1:2002
Oprema za splošno razsvetljavo - Zahteve za odpornost proti EMC (IEC
61547:2009)
Equipment for general lighting purposes - EMC immunity requirements (IEC 61547:2009)
Einrichtungen für allgemeine Beleuchtungszwecke - EMV-Störfestigkeitsanforderungen
(IEC 61547:2009)
Equipements pour l'éclairage à usage général - Exigences concernant l'immunité CEM
(CEI 61547:2009)
Ta slovenski standard je istoveten z: EN 61547:2009
ICS:
29.140.01 Žarnice na splošno Lamps in general
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61547
NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM
ICS 29.020; 29.140; 33.100.10 Supersedes EN 61547:1995 + A1:2000

English version
Equipment for general lighting purposes -
EMC immunity requirements
(IEC 61547:2009)
Equipements pour l'éclairage  Einrichtungen für allgemeine
à usage général - Beleuchtungszwecke -
Exigences concernant l'immunité CEM EMV-Störfestigkeitsanforderungen
(CEI 61547:2009) (IEC 61547:2009)

This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61547:2009 E
Foreword
The text of document 34/127/FDIS, future edition 2 of IEC 61547, prepared by IEC TC 34, Lamps and
related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 61547 on 2009-07-01.
This European Standard supersedes EN 61547:1995 + A1:2000.
The main reason for this revision is to update the dates of the references to the basic standards which
also required some editorial changes in the tables. Other changes are:
1 Scope: clearly excludes multimedia equipment with lamps (e.g. TV);
3.2 Enclosure port: removal of the “earth port” in Figure 1 as in the generic EMC standards; the note
below Figure 1 in EN 61547:1995 relates to a requirement and moved to the main text under 5.1
General;
5.6 Injected currents: update of the names of the example CDN’s;
5.7 Surges: test only at the peak of the mains voltage by deleting the requirement to test at zero
crossings;
5.8 Voltage dips and interruptions: clarifying that the voltage level changes at the zero crossing;
6.3.2 Independent auxiliaries: Table 14 has been simplified because most independent auxiliaries have
identical performance criteria;
6.3.3 Luminaires: Table 15 has been simplified because most luminaires have identical performance
criteria; correcting the error in the injected current column by changing the B into A for luminaires
with electronic ballast for discharge lamps; additionally, the requirements for emergency luminaires
operating in high risk task areas are updated to meet the levels specified in EN 60598-2-22;
7 Conditions during testing: the “under consideration” for the operating conditions for starting devices
has been deleted; the supply voltage and frequency during the test are clearly stated; shortening
the immunity test for equipment incorporating a regulating control by testing at one light output level
(50 % ± 10 %) instead of testing at three light output levels which are difficult to adjust and do not
provide extra protection.
This standard is to be read in conjunction with the relevant basic and/or product standard(s).
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-07-01
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and covers essential requirements of
EC Directive EMC (2004/108/EC). See Annex ZZ.
Annexes ZA and ZZ have been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61547:2009 was approved by CENELEC as a European
Standard without any modification.

- 3 - EN 61547:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

1)
IEC 60050-161 - International Electrotechnical Vocabulary - -
(IEV) -
Chapter 161: Electromagnetic compatibility

1)
IEC 60050-845 - International Electrotechnical Vocabulary - -
(IEV) -
Chapter 845: Lighting
IEC 60598-1 (mod) 2008 Luminaires - EN 60598-1 2008
Part 1: General requirements and tests A11 2009

1) 2)
IEC 60598-2-22 - Luminaires - EN 60598-2-22 1998
(mod) Part 2-22: Particular requirements - + corr. October 2007
Luminaires for emergency lighting

IEC 61000-4-2 2008 Electromagnetic compatibility (EMC) - EN 61000-4-2 2009
Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity
test
IEC 61000-4-3 2006 Electromagnetic compatibility (EMC) - EN 61000-4-3 2006
A1 2007 Part 4-3: Testing and measurement A1 2008
techniques - Radiated, radio-frequency, IS1 2009
electromagnetic field immunity test

IEC 61000-4-4 2004 Electromagnetic compatibility (EMC) - EN 61000-4-4 2004
Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst
immunity test
IEC 61000-4-5 2005 Electromagnetic compatibility (EMC) - EN 61000-4-5 2006
Part 4-5: Testing and measurement
techniques - Surge immunity test

IEC 61000-4-6 2008 Electromagnetic compatibility (EMC) - EN 61000-4-6 2009
Part 4-6: Testing and measurement
techniques - Immunity to conducted
disturbances, induced by radio-frequency
fields
IEC 61000-4-8 1993 Electromagnetic compatibility (EMC) - EN 61000-4-8 1993
A1 2000 Part 4-8: Testing and measurement A1 2001
techniques - Power frequency magnetic field
immunity test
1)
Undated reference.
2)
Valid edition at date of issue.

Publication Year Title EN/HD Year

IEC 61000-4-11 2004 Electromagnetic compatibility (EMC) - EN 61000-4-11 2004
Part 4-11: Testing and measurement
techniques - Voltage dips, short interruptions
and voltage variations immunity tests

IEC 61000-6-1 2005 Electromagnetic compatibility (EMC) - EN 61000-6-1 2007
Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial
environments
__________
- 5 - EN 61547:2009
Annex ZZ
(informative)
Coverage of Essential Requirements of EC Directives

This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and within its scope the standard covers all
relevant essential requirements as given in Annex I of the EC Directive 2004/108/EC.

Compliance with this standard provides one means of conformity with the specified essential
requirements of the Directive concerned.

WARNING: Other requirements and other EC Directives may be applicable to the products falling within
the scope of this standard.
__________
IEC 61547 ®
Edition 2.0 2009-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Equipment for general lighting purposes – EMC immunity requirements

Équipements pour l'éclairage à usage général – Exigences concernant
l’immunité CEM
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
P
CODE PRIX
ICS 29.020; 29.140; 33.100.10 ISBN 2-8318-1047-7
– 2 – 61547 © IEC:2009
CONTENTS
FOREWORD.4
1 Scope.6
2 Normative references .6
3 Terms and definitions .7
4 Performance criteria .8
5 Test specifications.9
5.1 General .9
5.2 Electrostatic discharges .9
5.3 Radio-frequency electromagnetic fields .10
5.4 Power frequency magnetic fields .10
5.5 Fast transients .10
5.6 Injected currents (radio-frequency common mode) .11
5.7 Surges .12
5.8 Voltage dips and short interruptions .12
5.9 Voltage fluctuations.13
6 Application of test specifications.13
6.1 General .13
6.2 Non-electronic lighting equipment.13
6.3 Electronic lighting equipment.13
6.3.1 General .13
6.3.2 Self-ballasted lamps .13
6.3.3 Independent auxiliaries.14
6.3.4 Luminaires.14
7 Conditions during testing .14
8 Assessment of conformity.15

Figure 1 – Examples of ports .8

Table 1 – Electrostatic discharges – Test levels at enclosure port.10
Table 2 – Radio-frequency electromagnetic fields – Test levels at enclosure port .10
Table 3 – Power frequency magnetic fields – Test levels at enclosure port .10
Table 4 – Fast transients – Test levels at ports for signal and control lines .10
Table 5 – Fast transients – Test levels at input and output d.c. power ports.11
Table 6 – Fast transients – Test levels at input and output a.c. power ports.11
Table 7 – Radio-frequency common mode – Test levels at ports for signal and control
lines.11
Table 8 – Radio-frequency common mode – Test levels at input and output d.c. power
ports .11
Table 9 – Radio-frequency common mode – Test levels at input and output a.c. power
ports .12
Table 10 – Surges – Test levels at input a.c. power ports .12
Table 11 – Voltage dips – Test levels at input a.c.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.