Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile

IEC 61400-25-4:2016 is also available as IEC 61400-25-4:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61400-25-4:2016 specifies the specific mappings to protocol stacks encoding the messages required for the information exchange between a client and a remote server for: data access and retrieval, device control, event reporting and logging, publisher/subscriber, self-description of devices (device data dictionary), data typing and discovery of data types. The mappings specified in this part of IEC 61400-25 comprise:
- a mapping to SOAP-based web services,
- a mapping to OPC/XML-DA,
- a mapping to IEC 61850-8-1 MMS,
- a mapping to IEC 60870-5-104,
- a mapping to DNP3.
The main technical changes with regard to the previous edition are as follows:
- general harmonization with information models in IEC 61400-25-2 and information exchange services in IEC 61400-25-3;
- reduction of overlap between standards and simplification by increased referencing.

Systèmes de génération d'énergie éolienne - Partie 25-4: Communications pour la surveillance et la commande des centrales éoliennes - Mapping pour les profils de communication

IEC 61400-25-4:2016 est disponible sous forme de IEC 61400-25-4:2016 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.
L'IEC 61400-25-4:2016 indique les mappings spécifiques pour les piles de protocoles qui codent les messages exigés pour les échanges d'information entre un client et un serveur à distance, pour: l'accès et la récupération de données, la commande de dispositif, l'établissement de rapports et la journalisation, l'éditeur/l'abonné, l'autodescription des dispositifs (dictionnaire de données des dispositifs), l'établissement de types de données et la découverte des types de données. Les mappings indiqués dans la présente partie de l'IEC 61400-25 comprennent:
- un mapping pour les services web basés sur SOAP,
- un mapping pour OPC/XML-DA,
- un mapping pour l'IEC 61850-8-1 MMS,
- un mapping pour l'IEC 60870-5-104,
- un mapping pour DNP3.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
- harmonisation générale avec les modèles d'information de l'IEC 61400-25-2 et les services d'échange d'information de l'IEC 61400-25-3;
- réduction de l'écart entre les normes et simplification grâce à un référencement amélioré.

General Information

Status
Published
Publication Date
29-Nov-2016
Current Stage
PPUB - Publication issued
Start Date
31-Dec-2016
Completion Date
30-Nov-2016
Ref Project

Relations

Buy Standard

Standard
iec61400-25-4{ed2.0.RLV}en - IEC 61400-25-4:2016 RLV - Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile Released:11/30/2016 Isbn:9782832236680
English language
829 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 61400-25-4 ®
Edition 2.0 2016-11
REDLINE VERSION
INTERNATIONAL
STANDARD
colour
inside
Wind turbines energy generation systems –
Part 25-4: Communications for monitoring and control of wind power plants –
Mapping to communication profile

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing 20 000 terms and definitions in
Technical Specifications, Technical Reports and other English and French, with equivalent terms in 15 additional
documents. Available for PC, Mac OS, Android Tablets and languages. Also known as the International Electrotechnical
iPad. Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a 65 000 electrotechnical terminology entries in English and
variety of criteria (reference number, text, technical French extracted from the Terms and Definitions clause of
committee,…). It also gives information on projects, replaced IEC publications issued since 2002. Some entries have been
and withdrawn publications. collected from earlier publications of IEC TC 37, 77, 86 and

CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
IEC 61400-25-4 ®
Edition 2.0 2016-11
REDLINE VERSION
INTERNATIONAL
STANDARD
colour
inside
Wind turbines energy generation systems –

Part 25-4: Communications for monitoring and control of wind power plants –

Mapping to communication profile

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 27.180 ISBN 978-2-8322-3668-0

– 2 – IEC 61400-25-4:2016 RLV © IEC 2016
CONTENTS
FOREWORD . 12
INTRODUCTION . 15
1 Scope . 16
2 Normative references . 17
3 Terms and definitions . 20
4 Abbreviated terms . 21
5 General overview . 22
5.1 General . 22
5.2 Mapping to protocol stacks . 23
5.3 Services of IEC 61400-25-3 mapped to protocol stacks . 24
Annex A (normative) Specific communication service mapping – Definition and
mapping to Web Services . 27
A.1 General . 27
A.1.1 Introduction to definition and mapping to Web Services . 27
A.1.2 Scope of the definition and mapping to Web Services . 27
A.1.3 The mapping architecture . 27
A.2 Reference specific to Web services .
A.2 Mapping of the IEC 61400-25 Information Model to Web Services . 30
A.2.1 General introduction to Annex A mapping to web services . 30
A.4.2 SERVER class .
A.4.3 LOGICAL-DEVICE class .
A.4.4 LOGICAL-NODE class .
A.4.5 DATA class .
A.4.6 DATA-SET class .
A.2.2 DATA OBJECT class . 33
A.2.3 DATA ATTRIBUTE definition . 34
A.4.8 DAType class .
A.4.9 REPORT-CONTROL-BLOCK class .
A.4.10 BUFFERED-REPORT-CONTROL-BLOCK class (BRCB) .
A.4.11 UNBUFFERED-REPORT-CONTROL-BLOCK class (URCB) .
A.4.12 LOG-CONTROL-BLOCK class (LCB) .
A.4.13 LOG class .
A.3 Abbreviated terms .
A.3 Mapping of the Information Exchange Model to Web Services . 34
A.3.1 General . 34
A.3.2 SERVER class service mapping . 34
A.3.3 LOGICAL-DEVICE class service mapping . 41
A.3.4 LOGICAL-NODE class services mapping . 42
A.3.5 DATA class services mapping . 45
A.3.6 DATA-SET class services mapping . 56
A.3.7 REPORT-CONTROL-BLOCK (RCB) class services mapping . 63
A.3.8 LOG-CONTROL-BLOCK (LCB) class services mapping . 81
A.3.9 LOG class services mapping. 84
A.3.10 CONTROL class services mapping . 89
A.4 Protocol stack details . 102
A.5 The WSDL specification for the definition and mapping to Web Services . 103

Annex B (normative) Specific communication service mapping – Mapping to OPC
XML-DA . 138
B.1 General . 138
B.1.1 Introduction to mapping to OPC XML-DA . 138
B.1.2 Scope for the mapping to OPC XML-DA. 138
B.1.3 The mapping architecture . 138
B.2 Reference specific to OPC XML-DA mapping .
B.2 Mapping of the IEC 61400-25 Information Model to OPC XML-DA. 142
B.2.1 Mapping of IEC 61400-25-2 Information Model classes to OPC XML-DA . 142
B.2.2 Server . 142
B.2.3 Logical Device . 143
B.2.4 Logical Node . 143
B.2.5 Data Object . 143
B.2.6 Data Attribute . 145
B.3 Abbreviated terms .
B.3 Mapping of the Information Exchange Model to OPC XML-DA services . 151
B.3.1 General . 151
B.3.2 Association model (informative) . 151
B.5.3 Server class model .
B.3.3 Server class services – GetServerDirectory . 155
B.5.4 Logical device class model .
B.3.4 Logical device class services – GetLogicalDeviceDirectory . 157
B.3.5 Logical node class models services . 159
B.3.6 Data class models services . 161
B.3.7 Data set class model (informative) . 169
B.3.8 Report class model . 173
B.3.9 Control model . 178
B.4 Protocol stack details . 188
Annex C (normative) Specific communication service mapping – Mapping to ISO 9506
specified in IEC 61850-8-1 . 190
C.1 General . 190
C.1.1 Introduction to mapping to ISO 9506 specified in IEC 61850-8-1. 190
C.1.2 Scope of the mapping to ISO 9506 specified in IEC 61850-8-1 . 190
C.1.3 The mapping architecture . 190
C.2 Reference specific to Annex C .
C.2 Mapping of the IEC 61400-25 Information Model to ISO 9506 as specified in
IEC 61850-8-1 . 193
C.2.1 General . 193
C.2.2 Extended Logging services . 195
C.3 Abbreviated terms for Annex C .
C.3 Protocol stack details . 196
C.3.1 General . 196
C.3.2 A-Profile . 196
C.3.3 TCP/IP T-Profile . 197
C.5 Mapping of the extended Information Exchange Model to ISO 9506 .
Annex D (normative) Specific communication service mapping – Mapping to
IEC 60870-5-104 specified in IEC TS 61850-80-1 . 198
D.1 General . 198
D.1.1 Introduction to mapping to IEC 60870-5-104 specified in IEC TS 61850-
80-1 . 198

– 4 – IEC 61400-25-4:2016 RLV © IEC 2016
D.1.2 Scope of the mapping to IEC 60870-5-104 specified in IEC TS 61850-
80-1 . 198
D.1.3 The mappi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.