2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.

  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.

  • Amendment
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides guidance for the application of the requirements contained in ISO 11607-1 and ISO 11607-2. It does not add to, or otherwise change, the requirements of ISO 11607-1 and ISO 11607-2. This is an informative document, not normative. It does not include requirements to be used as basis of regulatory inspection or certification assessment activities.
The guidance can be used to better understand the requirements of ISO 11607-1 and ISO 11607-2 and illustrates the variety of methods and approaches available for meeting the requirements of those International Standards. It is not required that this document be used to demonstrate conformity with them.
Guidance is given for evaluation, selection and use of packaging materials, preformed sterile barrier systems, sterile barrier systems and packaging systems. Guidance on validation requirements for forming, sealing and assembly processes is also given.
This document provides information for both healthcare facilities and the medical devices industry for terminally sterilized medical devices.
This document does not provide guidance for applications of packaging materials and systems after their opening. In the use of packaging for other purposes such as a “sterile field” or transport of contaminated items, other regulatory standards will apply.

  • Technical specification
    154 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
It is applicable to industry, to health care facilities, and to wherever medical devices are placed in sterile barrier systems and sterilized.
It does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.
It does not describe a quality assurance system for control of all stages of manufacture.
It does not apply to packaging materials and/or systems used to contain a contaminated medical device during transportation of the item to the site of reprocessing or disposal.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems.
It is applicable to industry, to health care facilities, and to wherever medical devices are packaged and sterilized.
It does not cover all requirements for packaging medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for sealable pouches and reels manufactured from porous materials complying with either EN 868 part 2, 3, 6, 7, 9 or 10 and plastic film complying with Clause 4. These sealable pouches and reels are used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for sealable adhesive coated nonwoven materials of polyolefines, manufactured from nonwovens complying with FprEN 868 9 used for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this European Standard.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for re-usable containers used as sterile barrier systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use. These containers are intended to be used in steam sterilizers conforming to EN 285.
NOTE 1   The need for a packaging material inside the container is determined by the manufacturers and users.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.
NOTE 2   When it is intended to use the containers in a steam sterilizer not conforming to EN 285 the sterilization performance of the container in the specific sterilization cycle to be used is validated by the user. Other attributes of the container are also reviewed for compatibility with the sterilizer cycle, e.g. operating temperature.
NOTE 3   The use of additional materials and/or accessories inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) is not covered in this part of EN 868. However, other requirements, including the determination of the acceptability of these materials and/or accessories during validation activities, can apply.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for uncoated nonwoven materials of polyolefines used for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this European Standard.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard provides test methods and values for materials for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the general requirements specified in EN ISO 11607-1.
As such, the particular requirements in 4.2 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1.
When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.
The materials specified in 4.2.2.1 to 4.2.2.3 of this part of EN 868 are intended for single use, the materials specified in 4.2.2.4 are intended for reuse.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard provides test methods and values for paper used in the manufacture of preformed sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the general requirements specified in EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1.
Paper specified in this part of the series EN 868 is intended for use in part or complete manufacture of pouches and form and fill packs and lidding material for packs.
NOTE 1   The paper specified in this part of the EN 868 series is suitable for the manufacture of sterile barrier systems to be used in ethylene oxide, irradiation or low temperature steam formaldehyde sterilization processes and to produce coated paper according to EN 868-7.
NOTE 2   Paper according to EN 868-3 can also be used for these sterilization processes.
The materials specified in this part of EN 868 are intended for single use only.
When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filters, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard provides test methods and values for paper bags manufactured from paper specified in EN 868-3, used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the general requirements specified in EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.6 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1.
The materials specified in this part of EN 868 are intended for single use only.
When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filter indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard provides test methods and values for paper, used in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the general requirements specified in EN ISO 11607-1.
As such, the particular requirements in 4.2 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1.
When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filter indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.
The materials specified in this part of EN 868 are intended for single use only.
NOTE   Applicable sterilization methods are specified by the manufacturer.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard provides test methods and values for sealable adhesive coated paper manufactured from paper complying with EN 868-6, used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use. The materials specified in this part are intended to be used for ethylene oxide or irradiation sterilization.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the general requirements specified in EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1.
When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for single-use paper bags manufactured from paper specified in EN 868-3, used as sterile barrier systems and/or packaging systems for terminally sterilized medical devices.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2, this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.

  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for paper used in the manufacture of single-use paper bags (specified in EN 868-4) and in the manufacture of single-use pouches and reels (specified in EN 868-5) used as sterile barrier systems and/or packaging systems for terminally sterilized medical devices by means of sterilization processes that require properties specific to higher temperature sterilization, such as moist heat sterilization used in healthcare facilities.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2 [2], this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.

  • Draft
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for sealable adhesive coated paper manufactured from paper complying with EN 868-6, used as single-use sterile barrier systems and/or single-use packaging systems for terminally sterilized medical devices by the means of low temperature sterilization processes.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2 [2], this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.

  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for sterilization wrap made of
-   single-use creped paper
-   single-use nonwoven materials
-   reusable woven textile materials
used as sterile barrier systems and/or packaging systems for terminally sterilized medical devices.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2 this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.

  • Draft
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods and values for paper used in the manufacture of single-use preformed sterile barrier systems and/or packaging systems for terminally sterilized medical devices by means of low temperature sterilization processes.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2 [2], this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this document.

  • Draft
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO/TS 16775:2014 provides guidance for the application of the requirements contained in ISO 11607‑1 and ISO 11607‑2. It does not add to, or otherwise change, the requirements of ISO 11607‑1 and/or ISO 11607‑2. It is an informative document, not normative, and does not include requirements to be used as basis of regulatory inspection or certification assessment activities.
The guidance can be used to better understand the requirements of ISO 11607‑1 and/or ISO 11607‑2 and illustrates some of the variety of methods and approaches available for meeting the requirements of those International Standards. It is not required to be used to demonstrate compliance with them.
Guidelines are given for evaluation, selection and use of packaging materials, preformed sterile barrier systems, sterile barrier systems and packaging systems. Guidance on validation requirements for forming, sealing and assembly processes is also given.
ISO/TS 16775:2014 provides information for health care facilities and for the medical devices industry. It does not provide guidance for applications of packaging materials and systems after their opening. In the use of packaging for other purposes such as a "sterile field" or transport of contaminated items, other regulatory standards will apply.

  • Technical specification
    124 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 11607-1:2006 specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
ISO 11607-1:2006 is applicable to industry, to health care facilities, and wherever medical devices are placed in sterile barrier systems and sterilized.
ISO 11607-1:2006 does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements might also be necessary for drug/device combinations.
ISO 11607-1:2006 does not describe a quality assurance system for control of all stages of manufacture.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 868 provides test methods and values for re-usable containers used as sterile barrier systems
that are intended to maintain sterility of terminally sterilized medical devices to the point of use. These
containers are intended to be used in steam sterilizers conforming to EN 285.
NOTE 1 The need for a packaging material inside the container is determined by the manufactures and users.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add nor modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.5 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
NOTE 2 When it is intended to use the containers in a steam sterilizer not conforming to EN 285 the sterilization performance
of the container in the specific sterilization cycle to be used is validated by the user. Other attributes of the
container are also reviewed for compatibility with the sterilizer cycle e.g. operating temperature.
NOTE 3 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

polyolefines, manufactured from nonwovens complying with EN 868-9 used for sterile barrier systems and/or
packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of
use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add nor modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 868 provides test methods and values for sealable pouches and reels manufactured from
porous materials complying with either EN 868 part 2, 3, 6, 7, 9 or 10 and plastic film complying with Clause 4
used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally
sterilized medical devices to the point of use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.5 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
The materials specified in this part of EN 868 are intended for single use only.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally
sterilized medical devices to the point of use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2013-10-08 GVN: Draft for // vote received in ISO/CS (see notification of 2013-10-08 in dataservice).
2013-01-09 EMA: Draft for // ENQ received in ISO/CS (see notification of 2013-01-08 in dataservice).
2012-02-14 EMA: WI allocated to WG 4 as per TC secretary request.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 11607 specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.

  • Amendment
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 11607-1:2006 specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
ISO 11607-1:2006 is applicable to industry, to health care facilities, and wherever medical devices are placed in sterile barrier systems and sterilized.
ISO 11607-1:2006 does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements might also be necessary for drug/device combinations.
ISO 11607-1:2006 does not describe a quality assurance system for control of all stages of manufacture.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 868 provides test methods and values for materials for sterile barrier systems and/or
packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of
use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 can be used to demonstrate compliance with one or more but not
all of the requirements of EN ISO 11607-1.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.
The materials specified in 4.2.2.1 to 4.2.2.3 of this part of EN 868 are intended for single use, the materials
specified in 4.2.2.4 are intended for reuse.
NOTE 3 If the intended purpose according to the manufacturer of the material for sterile barrier system specifies the
use as sterile field, then the additional requirements of the EN 13795 series apply.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

paper complying with EN 868-6, used as sterile barrier systems and/or packaging systems that are intended
to maintain sterility of terminally sterilized medical devices to the point of use. The materials specified in this
part are intended to be used for ethylene oxide or irradiation sterilization.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.
The materials specified in this part of EN 868 are intended for single use only.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 868 provides test methods and values for paper, used in the manufacture of paper bags
(specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) used as sterile
barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical
devices to the point of use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 can be used to demonstrate compliance with one or more but not
all of the requirements of EN ISO 11607-1.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter indicators, packing lists, mats, instrument organizer sets, tray liners
or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.
The materials specified in this part of EN 868 are intended for single use only.
NOTE 3 Applicable sterilization methods are specified by the manufacturer.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Part 3 of EN 868 provides test methods and values for paper bags manufactured from paper, used as sterile
barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical
devices to the point of use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.6 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
The materials specified in this part of EN 868 are intended for single use only.
NOTE 2 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filter indicators, packing lists, mats, instrument organizer sets, tray liners
or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 868 provides test methods and values for paper used in the manufacture of preformed sterile
barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical
devices to the point of use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the
products covered by this part of EN 868 but does not add or modify the general requirements specified in
EN ISO 11607-1.
As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more
but not all of the requirements of EN ISO 11607-1.
Paper specified in this part of the series EN 868 is intended for use in part or complete manufacture of
pouches and form and fill packs and lidding material for packs.
NOTE 2 The paper specified in this part of the series EN 868 is suitable for the manufacture of sterile barrier systems
to be used in ethylene oxide, irradiation or low temperature steam formaldehyde sterilization processes and to produce
coated paper according to EN 868-7.
NOTE 3 Paper according to EN 868-3 can also be used for these sterilization processes.
The materials specified in this part of EN 868 are intended for single use only.
NOTE 4 When additional materials are used inside the sterile barrier system in order to ease the organization, drying
or aseptic presentation (e.g. inner wrap, container filters, indicators, packing lists, mats, instrument organizer sets, tray
liners or an additional envelope around the medical device) then other requirements, including the determination of the
acceptability of these materials during validation activities, may apply.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements and test methods for packaging materials and final packages (systems) that are intended to maintain sterility of the terminally sterilized medical devices to the point of use. This standard is applicable to industry, health care facilities, and whererver sterilized medical devices are packed and sterilized.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of EN 868 provides examples of particular requirements for adhesive coated nonwoven materials of polyolefines suitable for use as packaging of medical devices which are to be terminally sterilized. It introduces no additional requirements to the general requirements of Part 1. As such, the particular requirements in 4.2 to 4.5 can be used to demonstrate compliance with one or more but not all of the requirements of Part 1. The material specified in this Part of the series EN 868 is intended for use in part or complete manufacture of heat sealable pouches, form and fill packs and lidding materials for packs.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of EN 868 provides examples of particular requirements for uncoated nonwoven materials of polyolefines suitable for use as packaging of medical devices which are to be terminally sterilized. It introduces no additional requirements to the general requirements of Part 1. As such, the particular requirements in 4.2 to 4.5 can be used to demonstrate compliance with one or more but not all of the requirements of Part 1. The material specified in this Part of the series EN 868 is intended for use in part or complete manufacture of heat sealable pouches, form and fill packs and lidding materials for packs.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of the series of EN 868 provides examples of particular requirements and test methods for paper bags manufactured from paper specified in Part 3 of this standard. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards. As such, the particular requirements in 4.2 to 4.7 can be used to demonstrate compliance with one or more but not all of the requirements of Part 1.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of the series of EN 868 provides examples of particular requirements and test methods for paper used in the manufacture of packs for medical use. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of the series of EN 868 provides examples of particular requirements and test methods for paper, used in the manufacture of paper bags (specified in prEN 868-4) and in the manufacture of pouches and reels (specified in prEN 868-5). It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of the series of EN 868 provides examples of particular requirements and test methods for re-usable containers for steam sterilization. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of the series of EN 868 provides examples of particular requirements and test methods for heat and self-sealable pouches and reels manufactured from paper complying with prEN 868-3 and plastic film complying with clause 4 of this Draft European standard. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of the series of EN 868 provides examples of particular requirements and test methods for sterilization wrap suitable for use as packaging of medical devices which are to be terminally sterilized. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of the series of EN 868 provides examples of particular requirements and test methods for heat sealable adhesive coated paper manufactured from paper complying with prEN 868-6, for use as packaging of medical devices which are to be terminally sterilized with ethylene oxide or irradiation. It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon various elements of former, relevant national standards.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1  This European Standard specifies the requirements and test methods for packaging materials and systems:   - which are used for packaging of medical devices which are to be terminally sterilized; and   - which are intended to maintain sterility of the device.   NOTE 1: This standard has been developed as a means to show compliance with relevant European Directives. If health care facilities e. g. hospitals do not place medical devices on the market, they are not covered by these Directives. Nevertheless, such health care facilities can fulfil the same requirements as manufacturers but can use alternative means to demonstrate conformity to this standard.   NOTE 2: Compliance with other Parts of prEN 868 series can be used to demonstrate compliance with one or more of the requirements of this standard.   1.2  This standard does not apply to packaging materials and systems used for packaging aseptically manufactured products.   1.3  This European Standard does not describe a quality assurance system for control of all stages of manufacture.   NOTE: Attention is drawn to the standards for quality systems (see e. g. EN ISO 9001, EN ISO 9002, EN 46001 or EN 46002) which control all stages of manufacture including the sterilization process. It is not a requirement of this standard to have a complete quality system during manufacture but certain elements of such a system can be applied.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day