IEC 60730-2-22:2014 applies to the partial evaluation of thermal motor protectors as defined in IEC 60730-1 for household and similar use, including heating, air conditioning and similar applications as well as for sealed (hermetic and semi-hermetic type) motor-compressors. A thermal motor protector is considered an integrated control since its protective functionality is dependent on the correct mounting and fixing in or on a motor and which can only be fully tested in combination with the relevant motor. This dependency is illustrated by: - the ability of the thermal motor protector to accurately and reliably sense the heat of the motor windings; - thus, addressing the over-temperature protection due to motor overload conditions; - the ability of the thermal motor protector to accurately and reliably sense the current due to motor locked-rotor conditions; - thus, reducing the response time and not being adversely affected by heat-sink at the assembly spot in the application and the influence of the motor's electromagnetic field on the switch behaviour of the thermal motor protector; - particularly, affecting the arc direction between the contacts resulting in uneven wear of the contact material and eventually leading to failure of operation. Requirements concerning the testing of the combination of sealed (hermetic and semi-hermetic type) motor-compressors and thermal motor protectors are given in IEC 60335-2-34. This standard applies to thermal motor protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Key words: Thermal, Motor protectors, Integrated control

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2022-04-07: This EN has no DOW.
NEXT ACTION: TC ACTION by 2022-06-01
2021-12-16: DOW removed from A1 further to  D170/C058. Mother EN has no DOW (justification in foreword)
2021-09-24: prAA including common mods to this A2 will be presented soon to BT
NEXT ACTION: TC ACTION by 2021-12-01
2020-08-19: NEXT ACTION BY TC: to deliver Annexes for FV assessment.

  • Amendment
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-12-12: D161/C021: make available the standard without offering it for citation.
2018-09-17: following plenary meeting, TC agrees to publish without any link to LVD, EMC. CLC/BT approval needed. To use PR=63458 for providing Annexes and Common Modifications, which are not ready yet.
included CM (63458)
2017-10-03 - Cannot allocate for publication due to missing assessment from Consultant.

  • Amendment
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-12:2015(E) applies to electrically operated door locks for use in, on or in association with equipment, including equipment for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard also applies to electrically operated door locks for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the equipment standard. This standard does not apply to electrically operated door locks intended for security access applications. This part 2 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the fifth edition (2013) of that publication. Consideration may be given to future editions of, or amendments to, IEC 60730-1. This third edition cancels and replaces the second edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - aligns the text with IEC 60730-1, Edition 5; - modifies requirements for Class B control function (H.27.1.2.2); - modifies requirements for Class C control function (H.27.1.2.3) and - modifies requirements for faults during safety shut-down. Key words: Locks, Door Locks, Control Systems

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-15:2017 applies to automatic electrical air flow, water flow and water level sensing controls for use in, or in association with, boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications. Examples are water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications. This document also applies to automatic electrical air flow, water flow and water level sensing controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: changes to align with the fifth edition of 60730-1, including the revised title. This Part 2-15 is intended to be used in conjunction with IEC 60730 1. It was established on the basis of the fifth edition of that standard (2013). Consideration may be given to future editions of, or amendments to, IEC 60730-1. This Part 2-15 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for humidity sensing controls. Where this Part 2-15 states "addition", "modification" or "replacement", the relevant requirement, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, this document indicates that the relevant clause or subclause of Part 1 applies.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-12-12: D161/C021: make available the standard without offering it for citation.
2018-09-17: following plenary meeting, TC decision to publish the mother standard and this amendment without links to LVD, EMC. CLC/BT approval needed before publication. A11 to be created to address harmonization.
20180308: publication on hold until mother standard is published

  • Amendment
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-9:2015(E) is available as IEC 60730-2-9:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60730-2-9:2015(E) applies to automatic electrical temperature sensing controls for use in, on or in association with equipment, including electrical controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard is applicable to automatic electrical temperature sensing controls forming part of a building automation control system within the scope of ISO 16484. This standard also applies to automatic electrical temperature sensing controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to automatic electrical temperature sensing controls intended exclusively for industrial process applications, unless explicitly mentioned in the relevant equipment standard. This standard applies to the inherent safety, to the operating values, operating times, and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical temperature sensing control devices used in, or in association with, equipment. This standard is also applicable to the functional safety of low complexity safety-related temperature sensing controls and systems. This fourth edition cancels and replaces the third edition published in 2008, and its Amendment 1:2011. This edition constitutes a technical revision. This edition includes alignment with the text of 60730-1 fifth edition and the following significant technical changes with respect to the previous edition: - modification of heating-freezing tests in Clause 12; - alignment of the EMC requirements in H.26 to those in other part 2 standards and - addition of requirements in Clause H.27 to cover class B and C control functions of temperature sensing controls. Key words: Controls, Temperature Sensing

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60730-2-14:2017 is available as IEC 60730-2-14:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60730-2-14:2017 applies to electric actuators for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This International Standard is applicable to controls for building automation within the scope of ISO 16484. This part 2-14 also applies to automatic electrical controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. EXAMPLE Controls for commercial catering, heating and air-conditioning equipment. Electric actuators for appliances are within the scope of IEC 60335. This second edition cancels and replaces the first edition, published in 1995, its Amendment 1 (2001) and its Amendment 2 (2007). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: adapting it to the 5th Ed of IEC 60730-1, addition of checking electric actuators with action 1.AB or 2AB, and modification of tests under abnormal condition. This Part 2-14 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the 5th edition of that standard (2013). Consideration may be given to future editions of, or amendments to, IEC 60730-1. This part 2-14 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for electric actuators. Where this part 2-14 states "addition", "modification" or "replacement", the relevant requirement, test specification or explanatory matter in part 1 should be adapted accordingly. Where no change is necessary part 2-14 indicates that the relevant clause or subclause applies. Key words: Automatic Controls, Electric Actuators

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-13:2017 applies to automatic electrical humidity sensing controls for use in, on or in association with equipment, including controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof. This Standard is applicable to automatic electrical humidity sensing controls forming part of a building automation control system within the scope of ISO 16484. This standard also applies to automatic electrical humidity sensing controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to automatic electrical humidity sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the equipment standard. This standard applies to automatic electrical controls, mechanically or electrically operated, responsive to or controlling humidity. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. This edition includes alignment with the text of 60730-1 fifth edition and the following significant technical changes with respect to the previous edition: - alignment of the EMC requirements in Clause H.26 to those in other part 2 standards; - addition of requirements in Clause H.27 to cover class B and C control functions of humidity sensing controls. This Part 2-13 is intended to be used in conjunction with IEC 60730 1. It was established on the basis of the fifth edition of that standard (2013). Consideration may be given to future editions of, or amendments to, IEC 60730-1. This Part 2-13 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for humidity sensing controls. Where this Part 2-13 states "addition", "modification" or "replacement", the relevant requirement, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, this Part 2-13 indicates that the relevant clause or subclause applies.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-01-16 PeC: Annexes ZZ for LVD and EMC are pending on part 1

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-03-19: to contact PM before proceeding with any assessment request.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: UNDER BT CONSULTATION, CLOSING ON 2020-03
2020-01-17 PeC: to pe published un-harmonized
2019-12-12 PeC: DOW to be set to DOR + 36 months
2019-10-23 PC: submission pending on the result of Part1
2019-06-13 PC: TC to updade EMC and LVD Annex ZZ
2019-03-19: to contact PM before proceeding with any assessment request.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-7:2015(E) applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications. This standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outputs. This standard does not apply to time-delay switches (TDS) within the scope of IEC 60669-2-3. This standard applies to the inherent safety, to the operating characteristics where such are associated with equipment protection and to the testing of timers used in appliances and other apparatus, electrical and non-electrical, for household and similar purposes, but also extended to industrial purposes when no dedicated product standards exist, such as that for central heating, air conditioning, process heating, etc. Timers for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This third edition cancels and replaces the second edition published in 2008. This third edition constitutes a technical revision. This new edition revises the compliance criteria of type 1.S and 2.S action, revises the requirements for filament lamp loads, adds requirements for abnormal operation in Annex H, removes some special requirements for single countries as well as updates the standard to IEC 60730-1:2010, fourth edition. Key words: Timers, Time Switches

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60730-2-8:2018 is available as IEC 60730-2-8:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60730-2-8:2018 applies to electrically operated water valves for use in, on or in association with equipment for household and similar use, including heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This document is applicable to electrically operated water valves for building automation within the scope of ISO 16484. This document also applies to automatic electrically operated water valves for equipment that can be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This document does not apply to electrically operated water valves intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This document applies to electrically operated water valves powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. This document does not cover the prevention of contamination of drinking water as a result of contact with materials. This document applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical control devices used in, on or in association with, household and similar equipment. This document contains requirements for electrical features of water valves and requirements for mechanical features of valves that affect their intended operation. This document is also applicable to electrically operated water valves for appliances within the scope of the IEC 60335 series of standards. This document does not apply to: - electrically operated water valves of nominal connection size above DN 50; - electrically operated water valves for admissible nominal pressure rating above 1,6 MPa; - food dispensers; - detergent dispensers; - steam valves; - electrically operated water valves designed exclusively for industrial applications. This document applies to electrically operated water valves, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof. This document also applies to actuators and to valve bodies which are designed to be fitted to each other. This document applies to individual valves, valves utilized as part of a system and valves mechanically integral with multi-functional controls having non-electrical outputs. This document applies to AC or DC powered electrically operated water valves with a rated voltage not exceeding 690 V AC or 600 V DC. This document does not take into account the response value of an automatic action of a valve, if such a response value is dependent upon the method of mounting the valve in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply. This document applies also to electrically operated water valves incorporating electronic devices, requirements for which are contained in

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-11:2019 is available as IEC 60730-2-11:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60730-2-11:2019 applies to energy regulators for use in, on, or in association with equipment, including energy regulators for heating, air conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof. This standard applies to the inherent safety, to the operating values, operating times and operating sequence where these are associated with equipment safety, and to the testing of automatic electrical energy regulator devices used in, or in association with, equipment. This standard is also applicable to energy regulators for appliances within the scope of IEC 60335-1. Throughout this standard the word “equipment” means “appliance and equipment”. This standard also applies to automatic electrical energy regulators for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to automatic electrical energy regulators designed exclusively for industrial process applications unless explicitly mentioned in the equipment standard. This standard does not apply to equipment that are specifically within the scope of building automation equipment. This standard is also applicable to individual energy regulators utilized as part of a control system or energy regulators which are mechanically integral with multi-functional controls having non-electrical outputs. This standard applies to controls powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision to the title to remove “for household and similar use”; b) changes to the scope and related modifications; c) changes to definitions in Annex H. This Part 2-11 is intended to be used in conjunction with IEC 60730 1. It was established on the basis of the fifth edition of that standard (2013) including Amendment 1 (2015). Consideration may be given to future editions of, or amendments to, IEC 60730-1. Keywords: Automatic Controls, Energy Regulators, Control Systems

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-12-16: DOW removed further to BT decision D170/C058. Mother EN has no DOW (justification in foreword)
2018-12-12: D161/C021: make available the standard without offering it for citation.
2018-09-17: following plenary meeting, CLC/TC 72 agreed to publish the project without Annex ZZ. No need for Common Modifications anymore. CLC/BT to approve the publication without link to EMC and LVD.  
2017-05-03: D156/C084 - Ratified standards not being made available.
2016-10-27: Publication on the hold (Common modifications needed + ZZ)

  • Amendment
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-6:2015(E) applies to automatic electrical pressure sensing controls with a minimum gauge pressure rating of -60 kPa and a maximum gauge pressure rating of 4,2 MPa, for use in, on or in association with, equipment. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof. This standard is also applicable to individual pressure sensing controls utilized as part of a control system or pressure sensing controls which are mechanically integral with multi-functional controls having non-electrical outputs. Automatic electrical pressure sensing controls for equipment used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard does not apply to pressure sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This standard applies to inherent safety, operating values, operating sequences where such are associated with equipment protection, and to the testing of automatic electrical pressure sensing controls used in, on or in association with equipment. This standard is also applicable to the functional safety of low complexity safety related pressure sensing controls and systems. This standard is also applicable to pressure sensing controls for appliances within the scope of IEC 60335-1. This third edition cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - aligns the text with IEC 60730-1, Edition 5; - modifies requirements for Class B control function (H.27.1.2.2); - modifies requirements for Class C control function (H.27.1.2.3) and - modifies requirements for faults during lock-out or safety- shut-down. Key words: sensing controls, control systems, pressure sensing

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-5:2013 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use. This part 2-5 is applicable to a complete burner control system and to a separate programming unit. This part 2-5 is also applicable to a separate electronic high-voltage ignition source and to a separate flame detector. Separate ignition devices (electrodes, pilot burners, etc.) are not covered by this part 2-5 unless they are submitted as part of a burner control system. Requirements for separate ignition transformers are contained in IEC 60989. Systems utilizing thermoelectric flame supervision are not covered by this part 2-5. This part 2-5 applies to the inherent safety, to the manufacturer's declared operating values, operating times and operating sequences where such are associated with burner safety and to the testing of automatic electrical burner control systems used in, on, or in association with, burners. This part 2-5 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the fourth edition (2010) of that publication. Consideration may be given to future editions of, or amendments to, IEC 60730-1. The title of IEC 60730-2-5 Ed4.0 has been updated to the title of IEC 60730-1 Ed5.0. However, IEC 60730-2-5 Ed4.0 has not been updated in accordance with the technical requirements in IEC 60730-1 Ed5.0. This part 2-5 supplements or modifies the corresponding clauses in IEC 60730-1 so as to convert that publication into the IEC standard: Safety requirements for automatic electrical burner control systems. Key words: Automatic control, Burner control

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-1:2013 applies to automatic electrical controls for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard is applicable to controls for building automation within the scope of ISO 16484. This standard also applies to automatic electrical controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard is also applicable to individual controls utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non electrical outputs. This standard is also applicable to relays when used as controls for IEC 60335 appliances. Additional requirements for the safety and operating values of relays when used as controls for IEC 60335 appliances are contained in Annex U. This standard does not apply to automatic electrical controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. This fifth edition cancels and replaces the fourth edition published in 2010. It constitutes a technical revision. The major changes with respect to the previous edition are as follows: - modification of the title and scope; - revisions to Clause H.26 based on changes in technology, applications, and to improve consistency and layout; - modification to Table H.12 to align with CISPR 22; - revisions to Annex J to correlate the fault modes of thermistors and to exempt thermistors used in conjunction with type 1 controls in SELV low power circuits from the tests specified in Annex J; - new requirements covering battery-powered controls, and the use of batteries in controls; - revision addressing the exclusion of relay faults; - new/updated requirements in Clause 24, for switch mode power supplies; - revisions covering the allowance of screwless-type clamping units complying with IEC 60999-1; - new requirements addressing remotely actuated control functions; - addition of a new/updated leakage current diagram to align the Annex E diagram with the diagram in IEC 60990 and updated requirements for temperature sensing controls. Key words: controls, electrical controls, automatic

  • Standard
    311 pages
    English language
    sale 10% off
    e-Library read for
    1 day

In general this standard applies to automatic electrical controls for use in, on, or in association with equipment for household and similar use, including controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc, or a combination thereof. This standard applies to automatic electric controls using NTC or PTC thermistors, additional requirements for which are contained in annex J of this standard. This standard applies to the inherent safety; to the operating values, operating times, and operating sequences where such are associated with equipment safety; and to the testing of automatic electrical control devices used in, or in association with, household or similar equipment. This standard does not apply to automatic electrical controls designed exclusively for industrial applications. This standard is also applicable to individual controls utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs. Automatic electrical controls for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.

  • Standard
    254 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60703-1:2010 applies to automatic electrical controls for use in, on, or in association with equipment for household and similar use, including controls for heating, air conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard also applies to the inherent safety; to the operating values, operating times, and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical control devices used in, or in association with, household or similar equipment. This standard is also applicable to controls for appliances within the scope of IEC 60335-1 as well as controls for building automation systems within the scope of ISO 16484-2. The principal changes in this edition as compared to the previous edition are as follows: - changes to the low temperature test requirements for in-line cords; - revision to the pollution degree for the environment surronding contacts; - addition of the use of screwless terminals on printed circuit boards and revisions to creepage distances; - additions of CISPR 11 EMC requirements; - incorporation of EMC test levels from IEC 60335 series; - additional testing for flexible cords; - revisions to the requirements for resistance to heat, fire and tracking including replacement of clause 21 and Annexes F and G; - new Annex T for additional requirements for non-SELV supplied sensor cable or cord; - new requirements in H.27.1 for first and second fault approach to ensure functional safety; - incorporation of software techniques from IEC 61508-3 in H.11.12; - replacement of Annex D (Canada and USA) with reference to UL 746C; - updates to the references and bibliography; - the keyword index was deleted.

  • Standard
    294 pages
    English language
    sale 10% off
    e-Library read for
    1 day

D126/C042: IEC 60730 series permanently excluded from parallel procedures * Superseded by EN 60730-1:2011

  • Amendment
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use. This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Same dow as in A12, A14 and A15 * Superseded by EN 60730-1:2011

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 60730-1:2000/A12:2003
2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report is a revision of R072-001:2000, List of interpretations on the EN 60730 series "Automatic electrical controls for household and similar use", which was based on document CLC/TC72/SEC0072L/INF.

  • Technical report
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60730 applies to the partial evaluation of thermal motor protectors as defined in IEC 60730-1 for sealed (hermetic and semi-hermetic type) motor-compressors. A thermal motor protector is an integrated control which is dependent on its correct mounting and fixing in or on a motor and which can only be fully tested in combination with the relevant motor. Requirements concerning the testing of the combination of motor and thermal motor protectors are given in IEC 60335-2-34. This standard applies to thermal motor protectors for motor compressors using NTC or PTC thermistors, additional requirements for which are contained in Annex J.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Supersedes EN 60730-1:2000/A11:2002 * Superseded by EN 60730-1:2011

  • Amendment
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The electrical safety tests described in this standard shall be carried out at the final stage of manufacture on the following Automatic Electrical Controls: a) free standing and in line cord controls, 100% of production. b) independently mounted Automatic Electrical Controls, 100% of production. c) any Automatic Electrical Controls with flexible integrated or internal conductors, 100% of production d) incorporated or integrated Automatic Electrical Controls with any surfaces directly accessible to the end user when mounted as declared 100% of production. Except that for controls where 100% testing is carried out on the final equipment in which the control is incorporated or integrated, routine testing is not required and testing is subject to agreement between the Control Manufacturer and the Appliance Manufacturer.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to automatic electrical controls for household and similar use. Part 1 gives the general requirements. Parts 2 to be used in conjunction with Part 1 will give particular requirements for specific types of controls.

  • Standard
    285 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Implementation dates aligned with those of A2 * Superseded by EN 60730-1:2000

  • Amendment
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Implementation dates aligned with those of A2 * Superseded by EN 60730-1:2000

  • Amendment
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 60730-1:2000

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60703-1:2022 applies to automatic electrical controls for use in, on, or in association with equipment for household appliance and similar use. This document applies to - the inherent safety of automatic electrical controls, and - functional safety of automatic electrical controls and safety related systems, - controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment.

  • Draft
    276 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-7:2008 applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications. This second edition cancels and replaces the first edition published in 1990 and its Amendment 1 (1994). This second edition constitutes a technical revision. This new edition incorporates requirements for tungsten filament lamp loadings as well as updates the standard to IEC 60730-1:1999, Amendment 2 (2007). This Part 2-7 is to be used in conjunction with IEC 60730-1. It was established on the basis of the third edition of that standard (1999) and its Amendment 1 (2003) and Amendment 2 (2007). Consideration may be given to future editions of, or amendments to, IEC 60730-1.

  • Draft
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-9:2008 applies to automatic electrical temperature sensing controls for use in, on or in association with equipment for household and similar use, including electrical controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This third edition cancels and replaces the second edition published in 2000, its Amendment 1 (2002) and Amendment 2 (2004) and constitutes a technical revision. This edition of IEC 60730-2-9 contains a new Annex EE, which is an informative guide to the application of temperature sensing controls. Additionally, a new requirement to 17.3.1 (there is an error in the FDIS document - 17.7.3 should be 17.3.1) was added to address the endurance requirement for temperature sensing devices where the whole control is declared as the sensing element for ambient temperatures below 0 °C. This document contains also some editorial changes due to new editions of referenced standards. This Part 2-9 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the third edition of that standard (1999) and its Amendment 1 (2003) and Amendment 2 (2007).Consideration may be given to future editions of, or amendments to, IEC 60730-1.

  • Standard
    68 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-7:2008 applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications. This second edition cancels and replaces the first edition published in 1990 and its Amendment 1 (1994). This second edition constitutes a technical revision. This new edition incorporates requirements for tungsten filament lamp loadings as well as updates the standard to IEC 60730-1:1999, Amendment 2 (2007). This Part 2-7 is to be used in conjunction with IEC 60730-1. It was established on the basis of the third edition of that standard (1999) and its Amendment 1 (2003) and Amendment 2 (2007). Consideration may be given to future editions of, or amendments to, IEC 60730-1.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to automatic electrical burner control systems for the automatic control of buners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use. This part is applicable to a complete burner control system and to separate programming unit. Is also applicable to a separate electronic high-voltage ignition source and to a separate flame detector.

  • Amendment
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60730 applies to automatic electrical air flow, water flow and water level sensing controls for use in, or in association with, boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air- conditioning and similar applications. This second edition cancels and replaces the first edition published in 1994 and its Amendment 1 (1997), the first edition of IEC 60730-2-16 published in 1995 and its Amendments 1 (1997) and 2 (2001) and the first edition of IEC 60730-2-18 published in 1997. This second edition constitutes a technical revision. This second edition is a consolidation of three standards IEC 60725-2-15, IEC 60730-2-16 and IEC 60730-2-18. The title and scope were revised to reflect the additional topics covered by the standard.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day