SC 7 - Non-measuring equipment made of glass, plastic and ceramics
- Abstract
Standardization of material characterization, specification, construction, marking and testing for laboratory equipment, which is not intended to be used for measurement of physical quantities. This includes standardization of principles and materials for construction, performance, dimensions and testing with respect to material characteristics, as well as the terms and definitions used in connection therewith.
- Slovenian
Matériel non métrologique en verre, plastique et céramique
Standardization of material characterization, specification, construction, marking and testing for laboratory equipment, which is not intended to be used for measurement of physical quantities. This includes standardization of principles and materials for construction, performance, dimensions and testing with respect to material characteristics, as well as the terms and definitions used in connection therewith.
This document specifies requirements and tests for glass Petri dishes intended for general laboratory purposes and microbiological work.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
This document specifies requirements for borosilicate 3,3 glass tubing according to ISO 3585 for laboratory apparatus in an outer diameter range from 4 mm to 300 mm. This document defines dimensions, material, denomination, designation, requirements and inspection methods.
- Standard13 pagesEnglish languagee-Library read for
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
ISO 16496:2016 recommends dimensions and specifies requirements and test methods for laboratory glassware manufactured from borosilicate glass 3.3 and provided with a vacuum jacket for thermal insulation. It covers Dewar vessels, vacuum-jacketed reaction vessels and vacuum-jacketed columns intended for laboratory use and laboratory related applications. Typical dimensions are given in Tables 1 to 5. ISO 16496:2016 does not apply to large scale production equipment and equipment operated with pressures of more than 0,1 bar above atmospheric pressure.
- Standard14 pagesEnglish languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
ISO 4796-1:2016 specifies a series of screw-neck bottles suitable for the storage of fluid liquid and solid chemicals and reagents in general laboratory use. These bottles with nominal volumes ranging from 25 ml to 20 000 ml are also suitable for the preparation and storage of microbiological growth media.
- Standard4 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
ISO 4797:2015 specifies requirements for an internationally acceptable series of boiling flasks with conical ground joints for general laboratory purposes.
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
ISO 3819:2015 specifies requirements for an internationally acceptable series of glass beakers for laboratory use.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
ISO 6556:2012 specifies requirements to filter flasks with conical or cylindrical shape for general laboratory purposes.
- Standard13 pagesEnglish languagee-Library read for
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
ISO 13130:2011 specifies requirements and tests for desiccators and vacuum desiccators intended for general laboratory purposes such as drying of substances or material.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard12 pagesRussian languagesale 15% off
ISO 24998:2008 specifies requirements and test methods for plain, single-use Petri dishes for microbiological use. ISO 24998:2008 does not apply to products of similar design which may be used for cell or tissue culture purposes. Neither does it apply to dishes supplied ready loaded with microbiological media.
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
ISO 24450:2005 specifies requirements and dimensions for an internationally acceptable series of conical flasks and of flat-bottom and round-bottom flasks with wide neck for general laboratory purpose. The flasks are provided for direct use in laboratory, fitting together with other equipment for general laboratory purposes, and for further work up to other products. For narrow-necked boiling flasks, ISO 1773 applies. For boiling flasks with conical ground joints, see ISO 4797.
- Standard4 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
ISO 4142:2002 specifies a range of test tubes, suitable for general laboratory use, fabricated from borosilicate, neutral or soda/lime glass, which are designated Type I, Type II and Type III respectively.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
This part of ISO 4796 specifies a series of bottles with a conical, wide or narrow neck with or without ground joints, suitable for the storage of liquid and solid chemicals and reagents in general laboratory use.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
This part of ISO 4796 specifies a series of aspirator bottles with a screw neck or with a conical neck suitable for the delivery of liquid chemicals and reagents in general laboratory use.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
This International Standard specifies details of an internationally acceptable series of glass separating funnels and dropping funnels suitable for general use in laboratories.
- Standard7 pagesEnglish languagee-Library read for
- Standard7 pagesEnglish languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
- Standard8 pagesEnglish languagee-Library read for
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesEnglish languagee-Library read for
- Standard8 pagesEnglish languagesale 15% off
Specifies requirements and dimensions for glass filter funnels suitable for general laboratory purposes, fitting together with other general-use glassware such as boiling flasks and volumetric flasks.
- Standard7 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard7 pagesEnglish languagee-Library read for
- Standard7 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
The principle of the method specified is conditioning the extract solution to be analyzed, developing the blue silicomolybdate complex using ammonium molybdate and a reducing solution, measuring the optical density of the resulting colour complex by means of a molecular absorption spectrometer at 800 nm using 10 mm optical cells. Measures the concentrations of silicon, expressed as its oxide SiO2. Applies to the analysis of extract solutions obtained from any kind of glass or glassware including laboratory and pharmaceutical ware, food and drink packaging ware, tableware and kitchenware.
- Standard8 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
The principle of the method specified is complexing of the aluminium in the extract solution to be analyzed with chromazurol S, measuring the optical density of the resulting solution by means of a molecular absorption spectrometer at 545 nm using 10 mm optical cells. Measures the concentration of aluminium, expressed as its oxide Al2O3. Applies to the analysis of extract solutions obtained from any kind of glass or glassware including laboratory and pharmaceutical ware, food and drink packaging ware, tableware and kitchenware.
- Standard8 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
The principle of the method specified is reducing the iron in the extract solution, complexing, extracting the complex into chloroform and measurement of the optical density of the resulting colour complex by means of a molecular absorption spectrometer at 533 nm or evaporating with hydrofluoric and perchloric acids, dissolving of the residue in hydrochloric acid, measuring the absorption using a flame atomic absorption spectrometer at 248,3 nm. Measures the concentration of iron, expressed as its oxide Fe2O3. Applies to the analysis of extract solutions obtained from any kind of glass or glassware.
- Standard9 pagesEnglish languagee-Library read for
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
The principle of the method specified is measuring the portion of the 422,7 nm line absorbed by calcium atoms and of the 285,2 nm line absorbed by magnesium atoms using a flame atomic absorption spectrometer, and comparison with the absorption produced by reference solutions. Measures the concentrations of calcium and magnesium, expressed as their oxides CaO and MgO. Applies to the analysis of extract solutions obtained from any kind of glass or glassware including laboratory and pharmaceutical ware, food and drink packaging ware, tableware and kitchenware.
- Standard9 pagesEnglish languagee-Library read for
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
The principle of the method specified is complexing of the boron in the extract solution to be analyzed with azomethine H, measurement of the optical density of the resulting colour complex by means of a molecular absorption spectrometer at 415 nm using 20 mm optical cells. Measures the concentration of boron, expressed as its oxide B2O3. Applies to the analysis of extract solutions obtained from any kind of glass or glassware including laboratory and pharmaceutical ware made, e.g., from borosilicate glass, neutral glass, tableware and kitchenware.
- Standard8 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
The principle of the method specified is spraying the extract solution into the flame of the burner of an emission or absorption spectrometer, if necessary with the addition of a spectrochemical buffer solution, or into the flame of a filter flame spectrometer without this addition. For FES and FAAS, the lines at 589,0 nm and 766,5 nm, respectively, are used and compared with the measurements of reference solutions, for a flame filter spectrometer, the specific filters are used. Measures the concentrations of sodium and potassium, expressed as their oxides Na2O and K2O. Applies to the analysis of extract solutions obtained from any kind of glass or glassware.
- Standard9 pagesEnglish languagee-Library read for
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
Describes the bending test for isotropic glass. The wavelength-dependent stress-optical coefficient is a characteristic value of materials and it is necessary for determining the stress from results of measurement of stress birefringence.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
Describes the tensile test for isotropic glass. The wavelength-dependent stress-optical coefficient is a characteristic value of materials and it is necessary for determining the stress from results of measurement of stress birefringence.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
Describes a test method for determining the stresses which may occur after the sealing of two glasses by means of stress birefringence.
- Standard7 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
Specifies the reagents, the preparation and number of samples, and the test procedure; describes the expression of results and the contents of the test report. This third edition cancels and replaces the second edition (1984).
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
Specifies a thermal shock test and the procedure for determining the thermal shock endurance. Does not apply to fused silica ware and annealed containers made from soda-lime-silicate glass.
- Standard5 pagesEnglish languagee-Library read for
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
The specified method is suitable for characterizing the low-viscosity range of glass working: A vertically positioned narrow metal rod, i.e. the bar, is allowed to sink under its own weight into the melt. From the rate of sinking the dynamic viscosity is calculated. The teoretical basis relation and the apparatus including method of measurements are described.
- Standard5 pagesEnglish languagesale 15% off
Rules a given characterizing glass as a liquid (or liquid-analogue deformable) material. Three ranges of viscosity can be distinguished: melting, working and annealing range. General requirements for measurement and calibration, for apparatus and for sampling are specified. The formulae for calculating the different values are described. In annex A tables for estimating the influence of errors in viscosity and temperature determination and in annex B examples of certified reference glasses are shown.
- Standard8 pagesEnglish languagesale 15% off
A method of determining the dynamic viscosity of glass on a rod-shaped test specimen, i.e. a beam, supported at its end is specified. The viscous deflection rate of the beam is measured under given load at the midpoint between the supports. In addition the viscosity-temperature relationship and the dependence of the viscosity on the thermal history of the sample can be determined. The theoretical basis relations and the apparatus including method of measurements are described.
- Standard12 pagesEnglish languagesale 15% off
This method allows continuous measurements viscosity and measurements under various shearing stresses. The viscosity is determined by the flow field coefficient, the torque and the rotational frequency. Two types of rotation viscometers are described: viscometer of the Couette type with adjustable revolving crucible and viscometer of Searle type with the crucibel at rest and the plunger revolving. The procedure is specified and typical examples of flow field with formules for calculating (annex A) and a typical rotation viscometer (annex B) are described.
- Standard10 pagesEnglish languagesale 15% off
The temperature characterizes a certain glass transition range from the elastic brittle (low temperature) state to the viscous (high temperature) state of glass. It is used for specifying cooling programmes. The transformation temperature is determined by measuring the change in length, related to the length at intial temperature, of a rod made from the glass under test with temperature. The relative change in length is plotted against the temperature (dilatometer curve). From this dilatometer curve the transformation temperature is determined by a graphic procedure as shown in a diagramm.
- Standard4 pagesEnglish languagesale 15% off
The method deals with the measurement of the change of length of a glass fibre under specified conditions. The apparatus including the used dilatometers and the possibilities of corretion, the formulae for the final length and the expansion coefficient are specified. In the annex, devices for self-adjusting alignment of specimen and push-rod axis are described and illustrated.
- Standard7 pagesEnglish languagesale 15% off
The temperatur above which the glass is capable of most forming operations is determined by measuring the elongation of a round glass fibre under its own weight. Closely defines requirements for the test specimen, procedure and apparatus lead to optimum repeatability of the specified temperature point. The furnace is specified with essential aspects.
- Standard6 pagesEnglish languagesale 15% off
A method of determining the dynamic viscosity of glass by measuring the elongation a glass fibre under a defined uniaxial stress. In addition the viscosity-temperature relationship and the dependence of the viscosity on the thermal history can be checked. The theoretical basis relation and the apparatus including the method of measuring are specified.
- Standard8 pagesEnglish languagesale 15% off
The specified method provides values being useful for specifying the cooling programme in the production of glassware. The annealing point is determined by measuring the rate of midpoint viscous bending of a simple loaded glass beam. The strain point is subsequently determined by an extrapolation method. Annex A provides the formulae for cross-sectional moment of inertia at various cross-section geometries, and annex B shows an example of beam bending apparatus
- Standard9 pagesEnglish languagesale 15% off
The specified method applies to pieces of glass, preferable flat but if necessary curved, but from articles of laboratory glassware. Sample pieces are subjected to an aqueous hydrochloric acid solution, and the amount of alkali metal oxides extracted per unit area is determined as a measure of the acid resistance. Apparatus, reagents, and procedure are specified.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
In addition to terms used in the three official ISO languages (English, French, Russian) the equivalent ones are given in German. A list of sections and subsections is given followed by the names for items of apparatus. Closely all apparatus are accompanied by a drawing. The vocabulary has an index of the proper names used to identify some of the items and a multilingual index is included.
- Standard100 pagesEnglish languagesale 15% off
- Standard296 pagesEnglish, French, German and Russian languagee-Library read for
The requirements deal with pipettes which are uncalibrated and intend for the transfer and dispensing of drops of solutions, and suspensions of biological materials. Two sizes are specified, details of which are given in a table, and the general form is illustrated in a figure. The resistance to sterilization by exposure to dry heat or to saturated steam is specified.
- Standard4 pagesEnglish languagee-Library read for
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
Test methods for determining the service performance of enamels are specified, i.e. for determining whether an enamel resists the specified treatment. The procedure insolve treatment for specified periods with an alkine detergent at 80 degrees centigrade and a dilute acid solution at room temperature.
- Standard4 pagesEnglish languagee-Library read for
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
The requirements specify a series of plastic cylinders having a tapered ore non-tapered form. The capacity is in the range from 25 ml to 5000 ml. For non-opaque beakers the graduation is specified. The construction, dimensions and material are described. The annexes deal with the test for ionic material extracted by water and with the flexibility test.
- Standard8 pagesEnglish languagee-Library read for
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
Six preferred sizes are defines by their internal bowl diameter. General design are shown in a figure and the dimensions are tabled. The material shall be general non-brittle plastics. Annex A concern the determination of resistance to extraction of ionic material by water, Annex B describes the flexibility test.
- Standard7 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
Filters are graded according to their pore size index in one of the eight classes specified. This is applicable to laboratory filters made of glass, vitreous silica, ceramics, metals and plastic materials. Annex A specifies a method for determination of pore size index. Annex B and C concern with a procedure for assessing uniformity of filters and for determination of air permeability.
- Standard9 pagesEnglish languagee-Library read for
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
Five types of condensors of three calsses according to design and the relative position of the colling medium with the nominal jacket length are specified: water jacket condenser (Allihn condenser, Liebig-West condenser and coiled destillate candenser), coolant-tube condenser, and double-section condenser. The material and the construction with ground glass joints are described by figures and tables for the dimensions.
- Standard8 pagesEnglish languagee-Library read for
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
The requirements deal with four series of conial ground joints. The conicity, the great diameter and the length of the ground joint including the tolerances are specified and tabled. In addition the surface finish and the peak-to-valley height are specified. In annex A a system of gauging for the diameters and lengths of these joints are given, in annex B a method of testing the leakage including the apparatus is describes.
- Standard7 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
Three types of crucibels are specified: Type 1, low form, type 2 medium form and type 3 tall form bases an a height/diameter ratio of 0,63; 0,8 and 1,25 resp. Further two types of lid are described: type D, a lid of slightly domed shape and typ R, a recessed lid. Material and construction are specified, shape and dimensions are shown in drawings and in a table.
- Standard6 pagesEnglish languagee-Library read for
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
Frequently Asked Questions
SC 7 is a Technical Committee within the International Organization for Standardization (ISO). It is named "Non-measuring equipment made of glass, plastic and ceramics" and is responsible for: Standardization of material characterization, specification, construction, marking and testing for laboratory equipment, which is not intended to be used for measurement of physical quantities. This includes standardization of principles and materials for construction, performance, dimensions and testing with respect to material characteristics, as well as the terms and definitions used in connection therewith. This committee has published 53 standards.
SC 7 develops ISO standards in the area of Information technology. The scope of work includes: Standardization of material characterization, specification, construction, marking and testing for laboratory equipment, which is not intended to be used for measurement of physical quantities. This includes standardization of principles and materials for construction, performance, dimensions and testing with respect to material characteristics, as well as the terms and definitions used in connection therewith. Currently, there are 53 published standards from this technical committee.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Technical Committee (TC) in ISO is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.