Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity

This European Standard specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their EMC environment. These levels represent essential EMC requirements.
The standard refers to normal EMC conditions as existing in residential, office and industrial buildings, but does not cover more severe EMC environments such as:
radio transmitter stations;
railways and metros;
heavy industrial plant;
electricity power stations
which need additional investigations.
This standard addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer.
This standard addresses the environmental conditions stated in the EN 81 series of standards and EN 115 (humidity, temperature, etc.), so far as they are related to EMC performance.
However:
performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence;
this standard does not apply to other apparatus already proven to be in conformity to the EMC Directive, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc.
This standard is not applicable to lifts, escalators, moving walks and related safety components manufactured before the date of publication of this standard by CEN.

Elektromagnetische Verträglichkeit - Produktfamilien-Norm für Aufzüge, Fahrtreppen und Fahrsteige - Störfestigkeit

Diese Europäische Norm legt die Bewertungskriterien und Prüfschärfegrade für Aufzüge, Fahrtreppen und Fahrsteige fest, die dauerhaft in Gebäuden installiert sind, einschließlich der grundlegenden Sicherheitsanforderungen im Hinblick auf ihre EMV-Umgebung. Diese Prüfschärfegrade stellen wesentliche EMV-Anforderungen dar.
Die Norm erstreckt sich auf normale EMV-Umgebungsbedingungen, wie sie in Wohn, Büro und Industriegebäuden vorliegen, aber deckt keine hochbelasteten Umgebungen ab wie:
¾ Rundfunksender;
¾ Eisen- und Untergrundbahnen;
¾ Anlagen der Schwerindustrie;
¾ elektrische Kraftwerke
die zusätzliche Untersuchungen erfordern.
Diese Norm behandelt allgemein bekannte EMV-relevante Gefährdungen und Gefährdungssituationen, die auf Aufzüge, Fahrtreppen und Fahrsteige zutreffen, wenn sie bestimmungsgemäß und entsprechend den vom Hersteller vorgesehenen Bedingungen verwendet werden.
Diese Norm behandelt die Umgebungsbedingungen der Geräte, die in EN 81 und EN 115 festgelegt sind (Feuchte, Temperatur), soweit sie die EMV-Eigenschaften betreffen.
Einschränkungen :
¾ Prüfschärfegrade und Bewertungskriterien für Einrichtungen, die in allgemeinen Funktionsbaugruppen  eingesetzt werden, decken keine Situationen ab, die nur mit einer äußerst geringen Wahrscheinlichkeit eintreten;
Diese Norm bezieht sich nicht auf Beleuchtungseinrichtungen und andere Vorrichtungen, die schon auf Konformität mit der EMV Richtlinie geprüft sind.

Compatibilité électromagnétique - Norme famille de produits pour ascenseurs, escaliers mécaniques et trottoirs roulants - Immunité

Cette norme européenne définit les critères d'aptitude et les niveaux d'essai d'immunité pour les ascenseurs, escaliers mécaniques et trottoirs roulants qui sont installés de façon permanente dans des bâtiments y compris les exigences de sécurité de base vis-à-vis de leur environnement électromagnétique. Ces niveaux représentent les exigences essentielles relatives à la compatibilité électromagnétiques.
La présente norme s'applique aux conditions d'environnement électromagnétique normales, telles qu'elles existent dans les bâtiments d'habitation, les immeubles de bureau et les établissements industriels, mais ne couvre pas les environnements électromagnétiques sévères comme :
¾ les émetteurs de radiodiffusion ;
¾ les chemins de fer et métro ;
¾ les installations d'industrie lourde ;
¾ les centrales électriques.
qui nécessitent des études supplémentaires.
Cette norme aborde les risques et situations dangereuses en matière de CEM, communément rencontrés lorsque les ascenseurs, escaliers mécaniques et trottoirs roulants sont utilisés pour l'usage prévu et dans les conditions prévues par le fabricant.
Cette norme aborde les conditions d'environnement des appareils mentionnées dans les EN 81 et EN 115 (humidité, température, etc.) pour autant qu'elles aient un rapport avec la Compatibilité Électromagnétique.
Cependant :
¾ les critères d'aptitude et les niveaux d'essai des appareillages utilisés dans des circuits à fonction générale ne couvrent pas les situations à faible probabilité d'occurrence ;
¾ la présente norme ne s'applique pas aux autres accessoires dont la conformité à la Directive CEM est déjà établie, comme les appareils d'éclairage, les appareils de communication, etc..

Elektromagnetna združljivost - Standard skupine izdelkov za dvigala, tekoče stopnice in trakove za osebe (steze) - Odpornost proti motnjam

General Information

Status
Withdrawn
Publication Date
07-Dec-2004
Withdrawal Date
09-Sep-2008
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
10-Sep-2008
Completion Date
10-Sep-2008

Relations

Buy Standard

Standard
EN 12016:2005
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - ImmunityCompatibilité électromagnétique - Norme famille de produits pour ascenseurs, escaliers mécaniques et trottoirs roulants - ImmunitéElektromagnetische Verträglichkeit - Produktfamilien-Norm für Aufzüge, Fahrtreppen und Fahrsteige - Störfestigkeit91.140.90Lifts. Escalators33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in generalICS:SIST EN 12016:2005enTa slovenski standard je istoveten z:EN 12016:200401-marec-2005SIST EN 12016:2005SLOVENSKI
STANDARDSIST EN 12016:19991DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12016
December 2004 ICS 33.100.20; 91.140.90 Supersedes EN 12016:1998 English version
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity
Compatibilité électromagnétique - Norme famille de produits pour ascenseurs, escaliers mécaniques et trottoirs roulants - Immunité
Elektromagnetische Verträglichkeit - Produktfamilien-Norm für Aufzüge, Fahrtreppen und Fahrsteige - Störfestigkeit This European Standard was approved by CEN on 28 November 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2004 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12016:2004: E

Relationship between this European Standard and the Essential Requirements of EU Directives.21 Bibliography.22

Electrostatic discharge immunity test (IEC 61000-4-2:1995). EN 61000-4-3, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement techniques; Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2002).

(IEC 61000-4-4:1995). EN 61000-4-5, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques;
Surge immunity test (IEC 61000-4-5:1995). EN 61000-4-6, Electromagnetic Compatibility (EMC) — Part 4-6: Testing and measurement techniques; Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6:1996). EN 61000-4-11, Electromagnetic Compatibility (EMC) — Part 4-11: Testing and measurement techniques —
Voltage dips, short interruptions and voltage variations immunity tests (IEC 61000-4-11:1994). EN 61000-6-1, Electromagnetic compatibility – Part 6-1: Generic standards – Immunity for residential, commercial and light-industrial environments (IEC 61000-6-1:1997, modified). EN 61000-6-2, Electromagnetic Compatibility (EMC) — Part 6-2: Generic standards - Immunity for industrial environments (IEC 61000-6-2:1999, modified. IEC 60050-161, International Electrotechnical Vocabulary - Chapter 161: Electromagnetic compatibility. 3 Terms and definitions For the purpose of this European Standard, the terms and definitions given in EN 1070, EN 61000-6-1, EN 61000-6-2, IEC 60050-161 and the following apply. 3.1 system lift escalator or moving walk comprising assembly of apparatus with electrical and electronic equipment and interconnections NOTE See Figure 1 and Figure 2 as examples. 3.2 assembly of apparatus arrangement of interconnected apparatus, which can be tested together NOTE See Figure 1 and Figure 2 as examples. 3.3 apparatus assembly of components with an intrinsic function as defined by its manufacturer NOTE 1 See Figure 1 a
...

Questions, Comments and Discussion