EN ISO 10993-3:2009
(Main)Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2003)
Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2003)
ISO 10993-3:2003 specifies strategies for hazard identification and tests on medical devices for the following biological aspects: genotoxicity, carcinogenicity, and reproductive and developmental toxicity.
ISO 10993-3:2003 is applicable for evaluation of a medical device whose potential for genotoxicity, carcinogenicity or reproductive toxicity has been identified.
Guidance on selection of tests is provided in ISO 10993-1.
Biologische Beurteilung von Medizinprodukten - Teil 3: Prüfungen auf Gentoxizität, Karzinogenität und Reproduktionstoxizität (ISO 10993-3:2003)
Évaluation biologique des dispositifs médicaux - Partie 3: Essais concernant la génotoxicité, la cancérogénicité et la toxicité sur la reproduction (ISO 10993-3:2003)
L'ISO 10993-3:2003 spécifie des stratégies pour l'identification des risques et des essais sur les dispositifs médicaux pour les aspects biologiques suivants: génotoxicité, cancérogénicité, et toxicité sur la reproduction et le développement.
L'ISO 10993-3:2003 est applicable pour l'évaluation d'un dispositif médical dont le risque potentiel de génotoxicité, de cancérogénicité ou de toxicité sur la reproduction a été identifié.
Des instructions relatives au choix des essais sont données dans l'ISO 10993-1.
Biološko ovrednotenje medicinskih pripomočkov - 3. del: Preskusi genske toksičnosti, kancerogenosti in toksičnosti za razmnoževanje (ISO 10993-3:2003)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2009
1DGRPHãþD
SIST EN ISO 10993-3:2004
%LRORãNRRYUHGQRWHQMHPHGLFLQVNLKSULSRPRþNRYGHO3UHVNXVLJHQVNH
WRNVLþQRVWLNDQFHURJHQRVWLLQWRNVLþQRVWL]DUD]PQRåHYDQMH,62
Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity
and reproductive toxicity (ISO 10993-3:2003)
Biologische Beurteilung von Medizinprodukten - Teil 3: Prüfungen auf Gentoxizität,
Karzinogenität und Reproduktionstoxizität (ISO 10993-3:2003)
Évaluation biologique des dispositifs médicaux - Partie 3: Essais concernant la
génotoxicité, la cancérogénicité et la toxicité sur la reproduction (ISO 10993-3:2003)
Ta slovenski standard je istoveten z: EN ISO 10993-3:2009
ICS:
11.100.20 %LRORãNRRYUHGQRWHQMH Biological evaluation of
PHGLFLQVNLKSULSRPRþNRY medical devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 10993-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2009
ICS 11.100.20 Supersedes EN ISO 10993-3:2003
English Version
Biological evaluation of medical devices - Part 3: Tests for
genotoxicity, carcinogenicity and reproductive toxicity (ISO
10993-3:2003)
Évaluation biologique des dispositifs médicaux - Partie 3: Biologische Beurteilung von Medizinprodukten - Teil 3:
Essais concernant la génotoxicité, la cancérogénicité et la Prüfungen auf Gentoxizität, Karzinogenität und
toxicité sur la reproduction (ISO 10993-3:2003) Reproduktionstoxizität (ISO 10993-3:2003)
This European Standard was approved by CEN on 28 April 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 10993-3:2009: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Annex ZA (Informative) Relationship between this European Standard and the Essential
Requirements of EU Directive 93/42/EEC .4
Foreword
The text of ISO 10993-3:2003 has been prepared by Technical Committee ISO/TC 194 “Biological evaluation
of medical devices” of the International Organization for Standardization (ISO) and has been taken over as EN
ISO 10993-3:2009 by Technical Committee CEN/TC 206 “Biological evaluation of medical devices” the
secretariat of which is held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by November 2009, and conflicting national standards shall be withdrawn
at the latest by March 2010.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 10993-3:2003.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EC Directive.
For relationship with EC Directive, see informative Annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 10993-3:2003 has been approved by CEN as a EN ISO 10993-3:2009 without any
modification.
Annex ZA
(Informative)
Relationship between this European Standard and the Essential
Requirements of EU Directive 93/42/EEC
This European Standard has been prepared under a mandate given to CEN by the European Commission
and the European Free Trade Association to provide a means of conforming to Essential Requirements of the
New Approach Directive 93/42/EEC on medical devices.
Once this standard is cited in the Official Journal of the European Communities under that Directive and has
been implemented as a national standard in at least one Member State, compliance with the clauses of this
standard given in Table ZA.1 confers, within the limits of the scope of this standard, a presumption of
conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations.
Table ZA.1 – Correspondence between this European Standard and EU Directives
Clause(s)/sub-clause(s) of this Essential Requirements (ERs) of Qualifying
EN Directive 93/42/EEC remarks/Notes
4, 5, 6, 7
Annex I:
7.1, 7.2, 7.5
WARNING: Other requirements and other EU Directives may be applicable to the product(s) falling within the
scope of this standard.
INTERNATIONAL ISO
STANDARD 10993-3
Second edition
2003-10-15
Biological evaluation of medical
devices —
Part 3:
Tests for genotoxicity, carcinogenicity
and reproductive toxicity
Évaluation biologique des dispositifs médicaux —
Partie 3: Essais concernant la génotoxicité, la cancérogénicité et la
toxicité sur la reproduction
Reference number
ISO 10993-3:2003(E)
©
ISO 2003
ISO 10993-3:2003(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2003
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2003 — All rights reserved
ISO 10993-3:2003(E)
Contents Page
Foreword. iv
Introduction . vi
1 Scope. 1
2 Normative references. 1
3 Terms and definitions. 2
4 Genotoxicity tests. 3
4.1 General. 3
4.2 Test strategy. 3
4.3 Sample preparation. 4
4.4 Test methods. 4
4.4.1 In vitro genotoxicity tests. 4
4.4.2 In vivo genotoxicity tests . 4
5 Carcinogenicity tests. 5
5.1 General. 5
5.2 Test strategy. 5
5.3 Sample preparation. 5
5.4 Test methods. 5
6 Reproductive and developmental toxicity tests . 6
6.1 General. 6
6.2 Test strategy. 6
6.3 Sample preparation. 6
6.4 Test methods. 7
7 Test report. 7
Annex A (informative) Cell transformation test system . 8
Annex B (informative) Rationale of test systems. 9
Annex C (informative) Role of implantation carcinogenicity studies. 11
Bibliography . 13
ISO 10993-3:2003(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 10993-3 was prepared by Technical Committee ISO/TC 194, Biological evaluation of medical devices.
This second edition cancels and replaces the first edition (ISO 10993-3:1992), which has been technically
revised.
ISO 10993 consists of the following parts, under the general title Biological evaluation of medical devices:
Part 1: Evaluation and testing
Part 2: Animal welfare requirements
Part 3: Tests for genotoxi
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.