Equipment for general lighting purposes - EMC immunity requirements

IEC 61547:2009 for electromagnetic immunity requirements applies to lighting equipment which is within the scope of IEC Technical Committee 34, such as lamps, auxiliaries and luminaires, intended either for connecting to a low voltage electricity supply or for battery operation. Excluded from the scope of this standard is equipment for which the immunity requirements are formulated in other IEC or CISPR standards. The main reason for this revision is to update the dates of the references to the basic standards which also required some editorial changes in the tables.

Einrichtungen für allgemeine Beleuchtungszwecke - EMV-Störfestigkeitsanforderungen

Equipements pour l'éclairage à usage général - Exigences concernant l'immunité CEM

La CEI 61547:2009 concernant les exigences d'immunité électromagnétique s'applique aux appareils d'éclairage entrant dans le domaine d'application du Comité d'études 34 de la CEI, tels que les lampes, les accessoires et les luminaires, destinés à être raccordés au réseau d'alimentation électrique public basse tension ou à fonctionner sur piles. Sont exclus du domaine d'application de la présente norme les équipements pour lesquels les exigences d'immunité sont formulées dans d'autres normes CEI ou CISPR. La raison principale de la présente révision est la mise à jour des dates des références aux normes fondamentales, ce qui a également nécessité certaines modifications rédactionnelles des tableaux.

Oprema za splošno razsvetljavo - Zahteve za odpornost proti EMC (IEC 61547:2009)

General Information

Status
Published
Publication Date
11-Aug-2009
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available
Due Date
12-Aug-2009
Completion Date
12-Aug-2009

RELATIONS

Buy Standard

Standard
EN 61547:2009
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 61547:2009
01-oktober-2009
1DGRPHãþD
SIST EN 61547:1996
SIST EN 61547:1996/A1:2002
Oprema za splošno razsvetljavo - Zahteve za odpornost proti EMC (IEC
61547:2009)

Equipment for general lighting purposes - EMC immunity requirements (IEC 61547:2009)

Einrichtungen für allgemeine Beleuchtungszwecke - EMV-Störfestigkeitsanforderungen

(IEC 61547:2009)

Equipements pour l'éclairage à usage général - Exigences concernant l'immunité CEM

(CEI 61547:2009)
Ta slovenski standard je istoveten z: EN 61547:2009
ICS:
29.140.01 Žarnice na splošno Lamps in general
33.100.20 Imunost Immunity
SIST EN 61547:2009 en,fr

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 61547:2009
---------------------- Page: 2 ----------------------
SIST EN 61547:2009
EUROPEAN STANDARD
EN 61547
NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM
ICS 29.020; 29.140; 33.100.10 Supersedes EN 61547:1995 + A1:2000
English version
Equipment for general lighting purposes -
EMC immunity requirements
(IEC 61547:2009)
Equipements pour l'éclairage Einrichtungen für allgemeine
à usage général - Beleuchtungszwecke -
Exigences concernant l'immunité CEM EMV-Störfestigkeitsanforderungen
(CEI 61547:2009) (IEC 61547:2009)

This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply

with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard

the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on

application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other

language made by translation under the responsibility of a CENELEC member into its own language and notified

to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the

Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,

Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 61547:2009 E
---------------------- Page: 3 ----------------------
SIST EN 61547:2009
EN 61547:2009 - 2 -
Foreword

The text of document 34/127/FDIS, future edition 2 of IEC 61547, prepared by IEC TC 34, Lamps and

related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as

EN 61547 on 2009-07-01.
This European Standard supersedes EN 61547:1995 + A1:2000.

The main reason for this revision is to update the dates of the references to the basic standards which

also required some editorial changes in the tables. Other changes are:
1 Scope: clearly excludes multimedia equipment with lamps (e.g. TV);

3.2 Enclosure port: removal of the “earth port” in Figure 1 as in the generic EMC standards; the note

below Figure 1 in EN 61547:1995 relates to a requirement and moved to the main text under 5.1

General;
5.6 Injected currents: update of the names of the example CDN’s;

5.7 Surges: test only at the peak of the mains voltage by deleting the requirement to test at zero

crossings;

5.8 Voltage dips and interruptions: clarifying that the voltage level changes at the zero crossing;

6.3.2 Independent auxiliaries: Table 14 has been simplified because most independent auxiliaries have

identical performance criteria;

6.3.3 Luminaires: Table 15 has been simplified because most luminaires have identical performance

criteria; correcting the error in the injected current column by changing the B into A for luminaires

with electronic ballast for discharge lamps; additionally, the requirements for emergency luminaires

operating in high risk task areas are updated to meet the levels specified in EN 60598-2-22;

7 Conditions during testing: the “under consideration” for the operating conditions for starting devices

has been deleted; the supply voltage and frequency during the test are clearly stated; shortening

the immunity test for equipment incorporating a regulating control by testing at one light output level

(50 % ± 10 %) instead of testing at three light output levels which are difficult to adjust and do not

provide extra protection.

This standard is to be read in conjunction with the relevant basic and/or product standard(s).

The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-07-01

This European Standard has been prepared under a mandate given to CENELEC by the European

Commission and the European Free Trade Association and covers essential requirements of

EC Directive EMC (2004/108/EC). See Annex ZZ.
Annexes ZA and ZZ have been added by CENELEC.
__________
Endorsement notice

The text of the International Standard IEC 61547:2009 was approved by CENELEC as a European

Standard without any modification.
---------------------- Page: 4 ----------------------
SIST EN 61547:2009
- 3 - EN 61547:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD

applies.
Publication Year Title EN/HD Year
IEC 60050-161 - International Electrotechnical Vocabulary - -
(IEV) -
Chapter 161: Electromagnetic compatibility
IEC 60050-845 - International Electrotechnical Vocabulary - -
(IEV) -
Chapter 845: Lighting
IEC 60598-1 (mod) 2008 Luminaires - EN 60598-1 2008
Part 1: General requirements and tests A11 2009
1) 2)
IEC 60598-2-22 - Luminaires - EN 60598-2-22 1998
(mod) Part 2-22: Particular requirements - + corr. October 2007
Luminaires for emergency lighting
IEC 61000-4-2 2008 Electromagnetic compatibility (EMC) - EN 61000-4-2 2009
Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity
test
IEC 61000-4-3 2006 Electromagnetic compatibility (EMC) - EN 61000-4-3 2006
A1 2007 Part 4-3: Testing and measurement A1 2008
techniques - Radiated, radio-frequency, IS1 2009
electromagnetic field immunity test
IEC 61000-4-4 2004 Electromagnetic compatibility (EMC) - EN 61000-4-4 2004
Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst
immunity test
IEC 61000-4-5 2005 Electromagnetic compatibility (EMC) - EN 61000-4-5 2006
Part 4-5: Testing and measurement
techniques - Surge immunity test
IEC 61000-4-6 2008 Electromagnetic compatibility (EMC) - EN 61000-4-6 2009
Part 4-6: Testing and measurement
techniques - Immunity to conducted
disturbances, induced by radio-frequency
fields
IEC 61000-4-8 1993 Electromagnetic compatibility (EMC) - EN 61000-4-8 1993
A1 2000 Part 4-8: Testing and measurement A1 2001
techniques - Power frequency magnetic field
immunity test
Undated reference.
Valid edition at date of issue.
---------------------- Page: 5 ----------------------
SIST EN 61547:2009
EN 61547:2009 - 4 -
Publication Year Title EN/HD Year
IEC 61000-4-11 2004 Electromagnetic compatibility (EMC) - EN 61000-4-11 2004
Part 4-11: Testing and measurement
techniques - Voltage dips, short interruptions
and voltage variations immunity tests
IEC 61000-6-1 2005 Electromagnetic compatibility (EMC) - EN 61000-6-1 2007
Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial
environments
__________
---------------------- Page: 6 ----------------------
SIST EN 61547:2009
- 5 - EN 61547:2009
Annex ZZ
(informative)
Coverage of Essential Requirements of EC Directives

This European Standard has been prepared under a mandate given to CENELEC by the European

Commission and the European Free Trade Association and within its scope the standard covers all

relevant essential requirements as given in Annex I of the EC Directive 2004/108/EC.

Compliance with this standard provides one means of conformity with the specified essential

requirements of the Directive concerned.

WARNING: Other requirements and other EC Directives may be applicable to the products falling within

the scope of this standard.
__________
---------------------- Page: 7 ----------------------
SIST EN 61547:2009
---------------------- Page: 8 ----------------------
SIST EN 61547:2009
IEC 61547
Edition 2.0 2009-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Equipment for general lighting purposes – EMC immunity requirements
Équipements pour l'éclairage à usage général – Exigences concernant
l’immunité CEM
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX
ICS 29.020; 29.140; 33.100.10 ISBN 2-8318-1047-7
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 9 ----------------------
SIST EN 61547:2009
– 2 – 61547 © IEC:2009
CONTENTS

FOREWORD...........................................................................................................................4

1 Scope...............................................................................................................................6

2 Normative references .......................................................................................................6

3 Terms and definitions .......................................................................................................7

4 Performance criteria .........................................................................................................8

5 Test specifications............................................................................................................9

5.1 General ...................................................................................................................9

5.2 Electrostatic discharges ..........................................................................................9

5.3 Radio-frequency electromagnetic fields .................................................................10

5.4 Power frequency magnetic fields ...........................................................................10

5.5 Fast transients ......................................................................................................10

5.6 Injected currents (radio-frequency common mode) ................................................11

5.7 Surges ..................................................................................................................12

5.8 Voltage dips and short interruptions ......................................................................12

5.9 Voltage fluctuations...............................................................................................13

6 Application of test specifications.....................................................................................13

6.1 General .................................................................................................................13

6.2 Non-electronic lighting equipment..........................................................................13

6.3 Electronic lighting equipment.................................................................................13

6.3.1 General .....................................................................................................13

6.3.2 Self-ballasted lamps ..................................................................................13

6.3.3 Independent auxiliaries..............................................................................14

6.3.4 Luminaires.................................................................................................14

7 Conditions during testing ................................................................................................14

8 Assessment of conformity...............................................................................................15

Figure 1 – Examples of ports ..................................................................................................8

Table 1 – Electrostatic discharges – Test levels at enclosure port.........................................10

Table 2 – Radio-frequency electromagnetic fields – Test levels at enclosure port .................10

Table 3 – Power frequency magnetic fields – Test levels at enclosure port ...........................10

Table 4 – Fast transients – Test levels at ports for signal and control lines ...........................10

Table 5 – Fast transients – Test levels at input and output d.c. power ports..........................11

Table 6 – Fast transients – Test levels at input and output a.c. power ports..........................11

Table 7 – Radio-frequency common mode – Test levels at ports for signal and control

lines......................................................................................................................................11

Table 8 – Radio-frequency common mode – Test levels at input and output d.c. power

ports .....................................................................................................................................11

Table 9 – Radio-frequency common mode – Test levels at input and output a.c. power

ports .....................................................................................................................................12

Table 10 – Surges – Test levels at input a.c. power ports .....................................................12

Table 11 – Voltage dips – Test levels at input a.c. power ports .............................................12

Table 12 – Voltage short interruptions – Test levels at input a.c. power ports .......................13

Table 13 – Application of tests for self-ballasted lamps.........................................................13

---------------------- Page: 10 ----------------------
SIST EN 61547:2009
61547 © IEC:2009 – 3 –

Table 14 – Application of tests for independent auxiliaries ....................................................14

Table 15 – Application of tests for luminaires........................................................................14

---------------------- Page: 11 ----------------------
SIST EN 61547:2009
– 4 – 61547 © IEC:2009
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
EQUIPMENT FOR GENERAL LIGHTING PURPOSES –
EMC IMMUNITY REQUIREMENTS
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

international co-operation on all questions concerning standardization in the electrical and electronic fields. To

this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

in the subject dealt with may participate in this preparatory work. International, governmental and non-

governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

with the International Organization for Standardization (ISO) in accordance with conditions determined by

agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence

between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in

the latter.

5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any

equipment declared to be in conformity with an IEC Publication.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

Publications.

8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 61547 has been prepared by IEC technical committee 34: Lamps

and related equipment.

This second edition cancels and replaces the first edition, published in 1995, and its

Amendment 1 (2000). It constitutes a technical revision

The main reason for this revision is to update the dates of the references to the basic

standards which also required some editorial changes in the tables. Other changes are:

1 Scope: clearly excludes multimedia equipment with lamps (e.g. TV);

3.2 Enclosure port: removal of the ”earth port” in Figure 1 as in the generic EMC

standards; the note below Figure 1 in the first edition relates to a requirement and

moved to the main text under 5.1 General;
5.6 Injected currents: update of the names of the example CDN’s;

5.7 Surges: test only at the peak of the mains voltage by deleting the requirement to test

at zero crossings;

5.8 Voltage dips and interruptions: clarifying that the voltage level changes at the zero

crossing;
---------------------- Page: 12 ----------------------
SIST EN 61547:2009
61547 © IEC:2009 – 5 –

6.3.2 Independent auxiliaries: Table 14 has been simplified because most independent

auxiliaries have identical performance criteria;

6.3.3 Luminaires: Table 15 has been simplified because most luminaires have identical

performance criteria; correcting the error in the injected current column by changing

the B into A for luminaires with electronic ballast for discharge lamps; additionally, the

requirements for emergency luminaires operating in high risk task areas are updated

to meet the levels specified in IEC 60598-2-22;

7 Conditions during testing: the ”under consideration” for the operating conditions for

starting devices has been deleted; the supply voltage and frequency during the test

are clearly st
...

Questions, Comments and Discussion