WG 1 - EMC instrumentation specifications
- Abstract
To prepare instrumentation specifications for the measurement
of emission and immunity.- Slovenian
EMC instrumentation specifications
Préparer les spécifications applicables à l'instrumentation de
mesure des émissions et de l'immunité.
CISPR 16-1-4:2019 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included.
NOTE In accordance with IEC Guide 107, CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of the value of particular EMC tests for specific products. The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in Part 2-3, further information on radio disturbance is given in Part 3, and uncertainties, statistics and limit modelling are covered in Part 4 of CISPR 16. This fourth edition cancels and replaces the third edition published in 2010, Amendment 1:2012 and Amendment 2:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
• provisions are added to address test site validation in the frequency range from 30 MHz to 1000 MHz using the reference site method, to take into account the receive antenna radiation pattern in the frequency range from 1 GHz to 18 GHz, and further details on test site validation using the NSA method with broadband antennas in the frequency range from 30 MHz to 1 000 MHz.
Keywords: radiated disturbances, frequency range 9 kHz to 18 GHz
- Standard227 pagesEnglish and French languagesale 15% off
- Standard506 pagesEnglish and French languagesale 15% off
- Standard659 pagesEnglish and French languagesale 15% off
- Standard89 pagesEnglish and French languagesale 15% off
Specifies a procedure for the determination of the kinematic viscosity of mineral insulating oils, both transparent and opaque, at very low temperatures, after a cold soaking period of at least 20 h, by measuring the time for a volume of liquid to flow under gravity throught a calibrated glass capillary viscometer. Applies at all temperatures to both Newtonian and non-Newtonian liquids having viscosities of up to 20 000 mm2/s.
- Standard48 pagesEnglish and French languagesale 15% off
CISPR 16-1-6:2014 provides procedures and supporting information for the calibration of antennas for determining antenna factors (AF) that are applicable to antennas intended for use in radiated disturbance measurements. It has the status of a basic EMC Standard in accordance with IEC Guide 107, Electromagnetic compatibility. The AF of an antenna is influenced by nearby surroundings and by its position in space relative to the radiating source. This standard focuses on antenna calibrations that provide the AF in a free-space environment in the direction of the boresight of the antenna. The frequency range addressed is 9 kHz to 18 GHz. The relevant antenna types covered in this standard are monopole, loop, dipole, biconical, log-periodic dipole-array (LPDA), hybrid and horn antennas. Guidance is also provided on measurement uncertainties associated with each calibration method and configuration, and the test instrumentation used.
- Standard758 pagesEnglish and French languagesale 15% off
- Standard360 pagesEnglish and French languagesale 15% off
- Standard836 pagesEnglish and French languagesale 15% off
CISPR 16-3:2020 is a collection of technical reports (Clause 4) that serve as background and supporting information for the various other standards and technical reports in CISPR 16 series. In addition, background information is provided on the history of CISPR, as well as a historical reference on the measurement of interference power from household and similar appliances in the VHF range (Clause 5). Over the years, CISPR prepared a number of recommendations and reports that have significant technical merit but were not generally available. Reports and recommendations were for some time published in CISPR 7 and CISPR 8. At its meeting in Campinas, Brazil, in 1988, CISPR subcommittee A agreed on the table of contents of CISPR 16-3, and to publish the reports for posterity by giving the reports a permanent place in CISPR 16-3. With the reorganization of CISPR 16 in 2003, the significance of CISPR limits material was moved to CISPR 16-4-3, whereas recommendations on statistics of disturbance complaints and on the report on the determination of limits were moved to CISPR 16‑4-4:2007. The contents of Amendment 1 (2002) of CISPR 16-3:2000 were moved to CISPR 16-4-1. NOTE As a consolidated collection of independent technical reports, this document can contain symbols that have differing meanings from one clause to the next. Attempts have been made to minimize this to the extent possible at the time of editing. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. The main technical change with respect to the previous edition consists of the addition of detailed background information on the large loop antenna system (LLAS) and its measurement method in general and on the models and equations which apply to calculate the reference validation factor and conversion factor curves.
- Technical report299 pagesEnglish languagesale 15% off
- Technical report599 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish and French languagesale 15% off
This part of CISPR 16 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document. The contents of the corrigendum of February 2006 have been included in this copy.
- Standard32 pagesEnglish languagesale 15% off
- Standard32 pagesFrench languagesale 15% off
- Standard63 pagesEnglish and French languagesale 15% off
- Standard141 pagesEnglish and French languagesale 15% off
- Standard136 pagesEnglish and French languagesale 15% off
CISPR 16-1-1: 2019 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic electromagnetic compatibility (EMC) standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of a basic EMC standard. CISPR and its subcommittee are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products. The specifications in this document apply to electromagnetic interference (EMI) receivers and spectrum analyzers. The term “measuring receiver” used in this document refers to both EMI receivers and spectrum analyzers (see also 3.7). The calibration requirements for measuring receivers are detailed in Annex J. Further guidance on the use of spectrum analyzers can be found in Annex B of any one of the following documents: CISPR 16-2-1:2014, CISPR 16-2-2:2010, or CISPR 16-2-3: 2016.This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes from the previous edition.
Keywords: measurement of radio disturbance in the frequency range 9 kHz to 18 GHz
- Standard195 pagesEnglish and French languagesale 15% off
CISPR 16-1-2:2014 specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz. It has the status of a basic EMC publication. Specifications for ancillary apparatus are included for artificial mains networks, current and voltage probes and coupling units for current injection on cables. It is intended that the requirements of this publication are fulfilled at all frequencies and for all levels of radio disturbance voltages and currents within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in the CISPR 16-2 series, and further information on radio disturbance is given in CISPR 16-3, while uncertainties, statistics and limit modelling are covered in the CISPR 16-4 series. This second edition cancels and replaces the first edition published in 2003 and its Amendment 1 (2004) and Amendment 2 (2006). This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- requirements from CISPR 22 for the AAN have been copied to this standard;
- and the CDNE for measurement of disturbance voltage in the frequency range 30 MHz to 300 MHz is added.
- Standard277 pagesEnglish languagesale 15% off
- Standard183 pagesEnglish and French languagesale 15% off
- Standard391 pagesEnglish and French languagesale 15% off
Gives requirements applying to the temporary electricalinstallations in exhibitions, shows and stands (including mobile and portable displays and equipment) to protect users.
- Standard13 pagesEnglish languagee-Library read for
- Standard22 pagesEnglish and French languagesale 15% off
CISPR 16-1-4:2010 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included. The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in Part 2-3, and further information on radio disturbance is given in Part 3 of CISPR 16. Uncertainties, statistics and limit modelling are covered in Part 4 of CISPR 16. This third edition of CISPR 16-1-4 cancels and replaces the second edition published in 2007 and its Amendments 1 (2007) and 2 (2008). It is a technical revision. This edition includes the following significant technical change with respect to the previous edition: provisions are added to address evaluation of a set-up table in the frequency range above 1 GHz. CISPR 16-1-4:2010 has the status of a basic EMC publication in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications
- Standard208 pagesEnglish and French languagesale 15% off
- Standard282 pagesEnglish and French languagesale 15% off
- Standard524 pagesEnglish and French languagesale 15% off
- Standard12 pagesEnglish and French languagesale 15% off
- Standard18 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- site validation methods for other sites covered in CISPR 16-1-6 are added;
- smaller step sizes are specified for swept frequency measurements;
- the minimum ground plane size is increased;
- and other miscellaneous technical and editorial refinements are included. Keywords: electromagnetic compatibility
The contents of the corrigendum 1 of August 2020 have been included in this copy.
- Standard385 pagesEnglish and French languagesale 15% off
- Standard192 pagesEnglish and French languagesale 15% off
CISPR 16-1-1:2015 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. This fourth edition cancels and replaces the third edition published in 2010, Amendment 1:2010 and Amendment 2:2014. This edition constitutes a technical revision.
The contents of the interpretation sheet 1 of April 2018 have been included in this copy.
- Standard302 pagesEnglish languagesale 15% off
- Standard205 pagesEnglish and French languagesale 15% off
- Standard28 pagesEnglish and French languagesale 15% off
- Standard91 pagesEnglish and French languagesale 15% off
- Standard14 pagesEnglish and French languagesale 15% off
CISPR 17:2011 specifies methods to measure the radio interference suppression characteristics of passive EMC filtering devices used in power and signal lines, and in other circuits. The defined methods may also be applied to combinations of over-voltage protection devices and EMC filtering devices. The measurement method covers the frequency range from 9 kHz to several GHz depending on the device and test circuit. The standard describes procedures for laboratory tests (type tests) as well as factory tests. The suppression characteristics of EMC filters and components used for the suppression of EM disturbances, are a function of numerous variables such as impedance of the circuits to which they connect, operating voltage and current, and ambient temperature. This standard specifies uniform test methods that will enable comparison of filtering and suppression characteristics determined by test laboratories or specified by manufacturers. Measurement procedures are provided for unbiased and bias conditions. Measurements under bias conditions are performed to determine potential non-linear behaviour of the EMC filtering devices such as saturation effects in inductors with magnetic cores. This testing serves to show the usability in a specific application (such as frequency converters that produce high amplitudes of common mode pulse current and thus may drive inductors into saturation). Measurement under bias conditions may be omitted if the non-linear behaviour can be determined by other methods (e.g. separate saturation measurement of the inductors used). The first edition of CISPR 17 (1981) prescribed the measurement methods of insertion loss mainly for power-line filters. Today, however, many types of sophisticated EMC filters and suppression components can be found in various electronic devices. Those filters need to be characterized using standardized measurement methods. New methods for measurement of impedance and S-parameters for such EMI devices are included in this second edition.
- Standard132 pagesEnglish and French languagesale 15% off
CISPR 16-1-1:2010 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. The specifications in this standard apply to EMI receivers and spectrum analyzers. This third edition cancels and replaces the second edition published in 2006, and its Amendments 1 (2006) and 2 (2007). It is a technical revision. This main technical change with respect to the previous edition consists of the addition of new provisions for the use of spectrum analyzers for compliance measurements. CISPR 16-1-1:2009 has the status of a basic EMC publication in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications.
The contents of the corrigendum of October 2010 have been included in this copy.
- Standard162 pagesEnglish and French languagesale 15% off
- Standard159 pagesEnglish and French languagesale 15% off
- Standard375 pagesEnglish and French languagesale 15% off
- Standard327 pagesEnglish and French languagesale 15% off
This part of CISPR 16 is designated a basic standard, which specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for ancillary apparatus are included for: antennas and test sites, TEM cells, and reverberating chambers. The requirements of this publication must be complied with at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in Part 2-3, and further information on radio disturbance is given in Part 3 of CISPR 16. Uncertainties, statistics and limit modelling are covered in Part 4 of CISPR 16.
- Standard90 pagesEnglish languagesale 15% off
- Standard90 pagesFrench languagesale 15% off
- Standard179 pagesEnglish and French languagesale 15% off
- Standard202 pagesEnglish and French languagesale 15% off
- Standard45 pagesEnglish and French languagesale 15% off
- Standard16 pagesEnglish and French languagesale 15% off
This part of CISPR 16 is designated a basic standard, which specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages, currents and fields in the frequency range 9 kHz to 18 GHz. In addition, requirements are specified for specialized equipment for discontinuous disturbance measurements. The requirements include the measurement of broadband and narrowband types of radio disturbance. The receiver types covered include the following: a) the quasi-peak measuring receiver, b) the peak measuring receiver, c) the average measuring receiver, d) the r.m.s. measuring receiver. The requirements of this publication shall be complied with at all frequencies and for all levels of radio disturbance voltages, currents, power or field strengths within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in Part 2, and further information on radio disturbance is given in Part 3 of CISPR 16. Uncertainties, statistics and limit modelling are covered in Part 4 of CISPR 16.
- Standard71 pagesEnglish languagesale 15% off
- Standard70 pagesEnglish languagesale 15% off
- Standard71 pagesFrench languagesale 15% off
- Standard70 pagesFrench languagesale 15% off
- Standard141 pagesEnglish and French languagesale 15% off
- Standard147 pagesEnglish and French languagesale 15% off
- Standard139 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
- Standard13 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
- Standard25 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard11 pagesEnglish and French languagesale 15% off
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard11 pagesEnglish and French languagesale 15% off
Contains a new subclause on capacitive voltage probe.
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
The second part of CISPR 16 specifies the methods of measurement of EMC phenomena in the frequency range 9kHz to 18 GHz. It deals with disturbance measurements and immunity measurements.
- Standard169 pagesEnglish and French languagesale 15% off
- Standard151 pagesEnglish and French languagesale 15% off
- Standard213 pagesEnglish and French languagesale 15% off
Defines a new subclause on field-strength measurements in the frequency range 1 GHz to 18 GHz.
- Standard19 pagesEnglish and French languagesale 15% off
Specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages, currents and fields in the frequency range 9 Hz to 18 GHz. In addition, requirements are specified for specialized equipment for discontinuous disturbance measurements. The requirements include the measurement of broadband and narrowband types of radio disturbance. Replaces the second edition of CISPR 16 published in 1987.
- Standard220 pagesEnglish and French languagesale 15% off
- Standard275 pagesEnglish and French languagesale 15% off
- Standard75 pagesEnglish and French languagesale 15% off
Specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages, currents and fields in the frequency range 9 kHz to 18 GHz. In addition, requirements are specified for specialized equipment for discontinuous disturbance measurements. The requirements include the measurement of broadband and narrowband types of radio disturbance. Replaces the first edition published in 1993, amendment 1 (1997) as well as consolidated edition 1.1 (1998).
- Standard422 pagesEnglish and French languagesale 15% off
- Standard407 pagesEnglish and French languagesale 15% off
- Standard17 pagesEnglish and French languagesale 15% off
Frequently Asked Questions
WG 1 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "EMC instrumentation specifications" and is responsible for: To prepare instrumentation specifications for the measurement of emission and immunity. This committee has published 1302 standards.
WG 1 develops IEC standards in the area of Information technology. The scope of work includes: To prepare instrumentation specifications for the measurement of emission and immunity. Currently, there are 1302 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.