EN 13237:2024
(Main)Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres
Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres
This document specifies terms and definitions (vocabulary) to be used in suitable standards dealing with equipment and protective systems intended for use in potentially explosive atmospheres within the scope of Directive 2014/34/EU.
NOTE Terms and definitions avoid misunderstandings that are important in relation to the essential health and safety requirements of Directive 2014/34/EU.
Explosionsgefährdete Bereiche - Begriffe für Geräte und Schutzsysteme zur Verwendung in explosionsgefährdeten Bereichen
Dieses Dokument legt Begriffe für die Anwendung in Normen fest, die sich mit Geräten und Schutzsystemen befassen, die für den Einsatz in explosionsgefährdeten Bereichen bestimmt sind, die unter den Anwendungsbereich der Richtlinie 2014/34/EU fallen.
ANMERKUNG Begriffe vermeiden Missverständnisse, was wichtig ist in Bezug auf die wesentlichen Gesundheits- und Sicherheitsanforderungen der Richtlinie 2014/34/EU.
Atmosphères explosibles - Termes et définitions pour les appareils et systèmes de protection destinés à être utilisés en atmosphères explosibles
Le présent document spécifie les termes et définitions (vocabulaire) à employer dans les normes spécifiques concernant les appareils et les systèmes de protection destinés à être utilisés en atmosphères explosibles et relevant du champ d’application de la directive 2014/34/EU.
NOTE Les termes et définitions permettent d’éviter des malentendus importants en ce qui concerne les exigences essentielles de santé et de sécurité de la directive 2014/34/UE.
Potencialno eksplozivne atmosfere - Izrazi in definicije za opremo in zaščitne sisteme, namenjene za uporabo v potencialno eksplozivnih atmosferah
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2024
Potencialno eksplozivne atmosfere - Izrazi in definicije za opremo in zaščitne
sisteme, namenjene za uporabo v potencialno eksplozivnih atmosferah
Potentially explosive atmospheres - Terms and definitions for equipment and protective
systems intended for use in potentially explosive atmospheres
Explosionsgefährdete Bereiche - Begriffe für Geräte und Schutzsysteme zur
Verwendung in explosionsgefährdeten Bereichen
Atmosphères explosibles - Termes et définitions pour les appareils et systèmes de
protection destinés à être utilisés en atmosphères explosibles
Ta slovenski standard je istoveten z: EN 13237:2024
ICS:
01.040.13 Okolje. Varovanje zdravja. Environment. Health
Varnost (Slovarji) protection. Safety
(Vocabularies)
01.040.29 Elektrotehnika (Slovarji) Electrical engineering
(Vocabularies)
13.230 Varstvo pred eksplozijo Explosion protection
29.260.20 Električni aparati za Electrical apparatus for
eksplozivna ozračja explosive atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 13237
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2024
EUROPÄISCHE NORM
ICS 01.040.13; 01.040.29; 13.230; 29.260.20 Supersedes EN 13237:2012
English Version
Potentially explosive atmospheres - Terms and definitions
for equipment and protective systems intended for use in
potentially explosive atmospheres
Atmosphères explosibles - Termes et définitions pour Explosionsgefährdete Bereiche - Begriffe für Geräte
les appareils et systèmes de protection destinés à être und Schutzsysteme zur Verwendung in
utilisés en atmosphères explosibles explosionsgefährdeten Bereichen
This European Standard was approved by CEN on 12 August 2024.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13237:2024 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
Annex A (informative) Definitions from Directive 2014/34/EU and corrigenda . 28
Annex B (informative) Significant changes between this document and EN 13237:2012 . 31
Annex ZA (informative) Relationship between this European Standard and the essential
requirements of Directive 2014/34/EU aimed to be covered . 36
Bibliography . 37
European foreword
This document (EN 13237:2024) has been prepared by Technical Committee CEN/TC 305 “Potentially
explosive atmospheres - Explosion prevention and protection”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2025, and conflicting national standards shall be
withdrawn at the latest by April 2025.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 13237:2012.
The significant technical changes between this document and EN 13237:2012 are given in Annex B,
Table B.1.
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
For relationship with EU Legislation, see informative Annex ZA, which is an integral part of this document.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
Introduction
This document has been produced to assist designers, manufacturers and other interested parties to use
harmonized terms and definitions (vocabulary) for equipment and protective systems intended for use
in potentially explosive atmospheres. It describes the vocabulary to be used to give all standards in this
area an overall uniformity of terminology. Throughout this document, the only hazard considered is the
explosion of an explosive atmosphere.
1 Scope
This document specifies terms and definitions (vocabulary) to be used in suitable standards dealing with
equipment and protective systems intended for use in potentially explosive atmospheres within the
scope of Directive 2014/34/EU.
NOTE Terms and definitions avoid misunderstandings that are important in relation to the essential health
and safety requirements of Directive 2014/34/EU.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— IEC Electropedia: available at https://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
3.1
air flow velocity
3 2
volume of air [m ] which flows through a defined surface [m ] per unit time [s]
[SOURCE: EN 17077:2018, 3.1]
3.2
ambient atmosphere
normal atmosphere surrounding the equipment and protective system
3.3
ambient temperature
temperature of the air or other media, in the immediate vicinity of the equipment or component
, 3.1, modified – Note 1 to entry, Note 2 to entry and Note 3 to entry have
[SOURCE: EN IEC 60079-0:2018
been removed]
3.4
atmospheric conditions
conditions with pressures ranging from 80 kPa to 110 kPa and temperatures ranging from −20°C to
+60°C
[SOURCE: EN ISO 16852:2016, 3.25]
Note 1 to entry: EN ISO 16852 will be replaced by EN ISO/IEC 80079-49 .
As impacted by EN IEC 60079-0:2018/AC:2020-02 and EN IEC 60079-0:2018/A11:2024.
To be published. Stage at the time of publication: FprEN ISO/IEC 80079-49.
3.5
combustible dust
finely divided solid particles, 500 µm or less in nominal size, which can form explosive mixtures with air
at standard atmospheric pressure and temperatures
Note 1 to entry: This includes dust and grit as defined in ISO 4225:2020.
Note 2 to entry: The term “solid particles” is intended to address particles in the solid phase but does not preclude
a hollow particle.
[SOURCE: EN ISO/IEC 80079-20-2:2016 , 3.1, modified — “may” has been replaced with “can”; reference
date in Note 1 to entry has been updated]
3.5.1
conductive dust
combustible metal dusts and other combustible dusts with electrical resistivity equal to or less than
1 × 10 Ω m
Note 1 to entry: Metal dust is treated as conductive dust because it is assumed that surface oxidation cannot be
depended upon to always ensure electrical resistivity greater than 1 × 10 Ω m
[SOURCE: EN ISO/IEC 80079-20-2:2016 , 3.1.1
3.5.2
non-conductive dust
combustible dust with electrical resistivity greater than 1 × 10 Ω m
[SOURCE: EN ISO/IEC 80079-20-2:2016 , 3.1.2]
3.6
combustible flyings
solid particles, including fibres, where one dimension is greater than 500 μm in nominal size, which may
form an explosive mixture with air at standard atmospheric pressure and temperature
Note 1 to entry: The ratio of length to width is 3 or more.
Note 2 to entry: Examples of flyings include carbon fibre, rayon, cotton (including cotton linters and cotton
waste), sisal, jute, hemp, cocoa fibre, oakum and baled waste kapok.
[SOURCE: EN ISO/IEC 80079-20-2:2016 , 3.2]
3.7
constructional safety “c”
ignition protection where constructional measures are applied so as to protect against the possibility of
ignition from hot surfaces, sparks and adiabatic compression generated by moving parts
[SOURCE: EN ISO 80079-37:2016, 3.1]
As impacted by EN ISO/IEC 80079-20-2:2016/AC:2017.
3.8
control of ignition source “b”
ignition protection where mechanical or electrical devices are used in conjunction with nonelectrical
equipment to manually or automatically reduce the likelihood of a potential ignition source from
becoming an effective ignition source
Note 1 to entry: This might for example be a level sensor used to indicate loss of oil, a temperature sensor to
indicate a hot bearing or a speed sensor to indicate over-speed.
[SOURCE: EN ISO 80079-37:2016, 3.3]
3.9
control measure
3.9.1
automatic control measure
action taken without manual intervention, to reduce the likelihood of a potential ignition source from
becoming an effective ignition source
[SOURCE: EN ISO 80079-37:2016, 3.3.1]
3.9.2
manual control measure
action taken by a person as a result of a warning, indication, or alarm, to reduce the likelihood of a
potential ignition source from becoming an effective ignition source
[SOURCE: EN ISO 80079-37:2016, 3.3.2]
3.10
ignition prevention device
ignition prevention system
arrangement that converts signals from one or more sensors into an action, or indication, to reduce the
likelihood of a potential ignition source from becoming an effective ignition source
[SOURCE: EN ISO 80079-37:2016, 3.3.3, modified – “ignition prevention devices/systems” has been
replaced with “ignition prevention device” and “ignition prevention system”]
3.11
safety device
device intended for use inside or outside explosive atmospheres but required for or contributing to the
safe functioning of equipment and protective systems with respect to the risks of explosion
[SOURCE: EN ISO 80079-37:2016, 3.3.4, modified – “devices” has been replaced with “device” (twice)]
3.12
continuous grade of release
release which is continuous or is expected to occur frequently or for long periods
[SOURCE: EN IEC 60079-10-1:2021, 3.4.2, modified – Note 1 to entry has been deleted]
3.13
deflagration
explosion propagating at subsonic velocity
[SOURCE: ISO 8421-1:1987, 1.11]
3.14
degree of protection
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid
foreign objects and/or ingress of water and verified by standardised test methods
[SOURCE: EN 60529:1991 , 3.3]
3.15
detonation
explosion propagating at supersonic velocity and characterised by a shock wave
[SOURCE: ISO 8421-1:1987, 1.12]
3.16
dust
small solid particles in the atmosphere which settle out under their own weight, but which may remain
suspended in air for some time
Note 1 to entry: Generally combustible dusts with a median value of the particle diameter below 500 µm may
form explosible dust/air-mixtures.
[SOURCE: EN 14034-1:2004+A1:2011, 3.1, modified — Note 1 to entry has been changed]
3.17
electrical equipment
items applied as a whole or in part for the utilisation of electrical energy
Note 1 to entry: These include, among others, items for the generation, transmission, distribution, storage,
measurement, regulation, conversion and consumption of electrical energy and items for telecommunications.
[SOURCE: EN IEC 60079-0:2018 , 3.31.1]
3.18
electrostatic leakage resistance
electrical resistance measured between an object and earth
[SOURCE: EN 14983:2007, 3.1]
3.19
enclosure (of equipment or protective system)
all the walls including doors, covers, cable entries, rods, spindles and shafts which contribute to the type
of protection and/or their degree of protection (IP)
...