SIGNIFICANCE AND USE
5.1 PFAS are widely used in various industrial and commercial products; they are persistent, bio-accumulative, and ubiquitous in the environment. PFAS have been reported to exhibit developmental toxicity, hepatotoxicity, immunotoxicity, and hormone disturbance. PFAS have been detected in soils, sludges, surface, and drinking waters. This is a quick, easy, and robust method to quantitatively determine these compounds at trace levels in soil/biosolid matrices.  
5.2 This test method has been validated using four ASTM reference soils (CH-1, ML-1, CL-1, and SP-1). ASTM reference soil CH-1 is Fat Clay (CH)—Vicksburg Buckshot Clay; ASTM reference soil ML-1 is silt (ML)—Vicksburg silt; ASTM reference soil CL-1 is lean clay (CL)—Annapolis clay; and ASTM reference soil SP-1 is sand (SP)—Frederick sand and four biosolids (Missouri, California, Idaho, and Georgia). Refer to the Precision and Bias (Section 17).
SCOPE
1.1 This test method covers the determination of per- and polyfluoroalkyl substances (PFAS) in soil/biosolid matrices by solvent extraction, filtering, separation using liquid chromatography (LC), and detection with tandem mass spectrometry (MS/MS). These analytes are extracted from soil/biosolids with basic water and methanol then qualitatively and quantitatively determined by this test method. Quantitation is by selected reaction monitoring (SRM), sometimes referred to as multiple reaction monitoring (MRM).  
1.2 The reporting limit (RL) and reporting range (see Note 2) for the target analytes are listed in Table 1. The reporting limit is calculated from the concentration of the Level 1 calibration standard as shown in Table 5 for the PFAS after taking into account a 2 g sample weight and a final extract volume of 10 mL, 50 % water/50 % MeOH with 0.1 % acetic acid. The final extract volume is assumed to be 10 mL because 10 mL of 50 % water/50 % MeOH with 0.1 % acetic acid was added to each soil sample and only the liquid layer after extraction is filtered, leaving the solid and any residual solvent behind. Sporadic PFAS hits due to PFAS contamination in consumables/collection tools used during sample collection and preparation is possible while executing this standard and must be monitored. All samples should be taken at a minimum as duplicates in order to compare the precision between the two prepared samples to help ensure the concentration/positive result is reliable.
Note 1: This standard only includes the determination of the analytes listed in Table 1 and is only applicable to soil and biosolid matrices; any added compost or soil additives may contain PFAS that may be bound and not able to be determined by this method. Analysis of packaging materials and polymeric PFAS moieties are not amenable to this standard.
Note 2: Injection volume variations and sensitivity of the instrument used will change the reporting limit and ranges.  
1.2.1 Recognizing continual advancements in the sensitivity of instrumentation, advancements in column chromatography, and other processes not recognized here, the reporting limit may be lowered assuming the minimum performance requirements of this test method at the lower concentrations are met.  
1.2.2 Depending on data usage, you may modify this test method but limit to modifications that improve performance while still meeting or exceeding the method quality acceptance criteria. Modifications to the solvents, ratio of solvent to sample, or shortening the chromatographic run simply to save time are not allowed. Use Practice E2935 or similar statistical tests to confirm that modifications produce equivalent results on non-interfering samples. In addition, use Guide E2857 or equivalent statistics to revalidate the modified test.  
1.2.3 Analyte detections under the reporting limit are estimated concentrations. If results are to be reported below the RL using this standard and following the method detection limit procedure in 40 CFR Part 136 Appen...

  • Standard
    34 pages
    English language

SIGNIFICANCE AND USE
4.1 The analysis of trace elements is often a regulatory and process-specific requirement for facilities utilizing LHWF. With proper instrument standardization, set-up, and quality control, this test method provides the user an accurate, rapid, nondestructive method for trace element determinations.
SCOPE
1.1 This test method applies to the determination of trace element concentrations by energy-dispersive X-ray fluorescence (EDXRF) spectrometry in typical liquid hazardous waste fuels (LHWF) used by industrial furnaces.  
1.2 This test method has been used successfully on numerous samples of LHWF that are mixtures of solvents, oils, paints, and pigments for the determination of the following elements: Ag, As, Ba, Cd, Cr, Hg, Ni, Pb, Sb, Se, and Tl.  
1.3 This test method also may be applicable to elements not listed above and to the analysis of trace metals in organic liquids other than those used as LHWF.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is intended as a means for obtaining sequential extracts of a waste. The extracts may be used to estimate the release of certain constituents of the waste under the laboratory conditions described in this test method.  
4.2 The pH of the extraction fluid used in this test method is to reflect the pH of acidic precipitation in the geographic region in which the waste being tested is to be disposed.
Note 1: Possible sources of information concerning the pH of precipitation in the geographic region of interest include state and federal environmental agencies, state universities, libraries, etc.  
Note 2: For sequential batch extraction of waste using a nonacidic extraction fluid, see Test Method D4793.  
4.3 An intent of this test method is for the final pH of each of the extracts to reflect the interaction of the extractant with the buffering capacity of the waste.  
4.4 This test method is not intended to provide extracts that are representative of the actual leachate produced from a waste in the field or to produce extracts to be used as the sole basis of engineering design.  
4.5 This test method has not been demonstrated to simulate actual disposal site leaching conditions.  
4.6 This test method produces extracts that are amenable to the determination of both major and minor (trace) constituents. When minor constituents are being determined, it is especially important that precautions be taken in sample storage and handling to avoid possible contamination of the samples.  
4.7 This test method has been tested to determine its applicability to certain inorganic components in the waste. This test method has not been tested for applicability to organic substances, volatile matter (see Note 5), or biologically active samples.  
4.8 The agitation technique, rate, liquid-to-solid ratio, and filtration conditions specified in the procedure may not be suitable for extracting all types of wastes (see Sections 7 and 8 and Appendix X1).
SCOPE
1.1 This test method provides a procedure for the sequential leaching of a waste containing at least 5 % dry solids in order to generate solutions to be used to determine the constituents leached under the specified testing conditions.  
1.2 This test method calls for the shaking of a known weight of waste with acidic extraction fluid of a specified composition as well as the separation of the liquid phase for analysis. The pH of the extraction fluid is to reflect the pH of acidic precipitation in the geographic region in which the waste being tested is to be disposed. The procedure is conducted ten times in sequence on the same sample of waste, and it generates ten solutions.  
1.3 This test method is intended to describe the procedure for performing sequential batch extractions only. It does not describe all types of sampling and analytical requirements that may be associated with its application.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    15 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method has been developed by the U.S. EPA Region 5 Chicago Regional Laboratory (CRL).  
5.2 PFAS are widely used in various industrial and commercial products; they are persistent, bio-accumulative, and ubiquitous in the environment. PFAS have been reported to exhibit developmental toxicity, hepatotoxicity, immunotoxicity, and hormone disturbance. A draft Toxicological Profile for Perfluoroalkyls from the U.S. Department of Health and Human Services is available.7 PFAS have been detected in soils, sludges, and surface and drinking waters. Hence, there is a need for a quick, easy, and robust method to determine these compounds at trace levels in various soil matrices for understanding of the sources and pathways of exposure.  
5.3 This method has been used to determine selected PFAS in sand (Table 4) and four ASTM reference soils (Table 5).
SCOPE
1.1 This procedure covers the determination of selected polyfluorinated alkyl substances (PFAS) in a soil matrix using solvent extraction, filtration, followed by liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS). These analytes are qualitatively and quantitatively determined by this method. This method adheres to multiple reaction monitoring (MRM) mass spectrometry. This procedure utilizes a quick extraction and is not intended to generate an exhaustive accounting of the content of PFAS in difficult soil matrices. An exhaustive extraction procedure for PFAS, such as published by Washington et al.,2 for difficult matrices should be considered when analyzing PFAS. The approach from this standard was utilized to screen laboratory coats (textiles) to identify if PFAS would be leached from the materials.  
1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 The method of detection limit3 and reporting range4 for the target analytes are listed in Table 1.    
1.3.1 The reporting limit in this test method is the minimum value below which data are documented as non-detects. Analyte detections between the method detection limit and the reporting limit are estimated concentrations and are not reported following this test method. In most cases, the reporting limit is calculated from the concentration of the Level 1 calibration standard as shown in Table 2 for the PFAS after taking into account a 2 g sample weight and a final extract volume of 10 mL, 50 % water/50 % MeOH with 0.1 % acetic acid. The final extract volume is assumed to be 10 mL because 10 mL of 50 % water/50 % MeOH with 0.1 % acetic acid was added to each soil sample and only the liquid layer after extraction is filtered, leaving the solid and any residual solvent behind. It is raised above the Level 1 calibration concentration for PFOS, PFHxA, FHEA, and FOEA; these compounds can be identified at the Level 1 concentration but the standard deviation among replicates at this lower spike level resulted in a higher reporting limit.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    24 pages
    English language
  • Standard
    24 pages
    English language

SIGNIFICANCE AND USE
5.1 Most facilities disposing or using waste materials are prohibited from handling wastes that contain radioactive materials. This practice provides the user a rapid method for screening waste material for the presence or absence of radioactivity at user-established levels that consider background radiation and the intended use of the screening method. It is important to these facilities to be able to verify generator-supplied information in regard to radiation and to meet worker health and safety needs.
SCOPE
1.1 This practice covers the screening for α–, β–, and γ radiation above ambient background levels or user-defined criteria, or both, in liquid, sludge, or solid waste materials.  
1.2 This practice is intended to be a gross screening method for determining the presence or absence of radioactive materials in liquid, sludge, or solid waste materials. It is not intended to replace more sophisticated quantitative analytical techniques, but to provide a method for rapidly screening samples for radioactivity above ambient background levels or user-defined criteria, or both, for facilities prohibited from handling radioactive waste.  
1.3 This practice may or may not be suitable for applications such as site assessments and remediation activities, depending on the data quality objectives or intended use.  
1.4 The values stated in SI units are to be regarded as the standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
4.1 This practice can be used in sampling ash from a kiln or incinerator, soils, and process waste from conveying systems, such as a conveyer and vertical lifts. Some slurries, such as the bottom solids, can be sampled from the quench waters at the end of a kiln.  
4.2 This practice can be used to determine material balances for burner efficiency studies and compliance studies.  
4.3 This practice can be used on lifts, sloping, and horizontal conveyor systems. The type of conveyor and the amount and type of sample required will dictate the type of sampling equipment required to get a representative sample.  
4.4 The sample is taken directly from the conveyor before emptying into the waste container or pile for disposal or recycling using a scoop, dipper, or shovel depending upon the sample requirements (see Practice D5633). The sample is then put into the sample container for analysis.  
4.5 The place, quantity, frequency, and time of sampling is dependent upon the conveying system equipment, data quality objectives (DQOs) (Practice D5792), work or sampling plan (see Practice D5283 and Guide D4687), and analysis to be run.  
4.5.1 Large particles can be mechanically excluded on a belt system. Large particles may accumulate at the bottom of an inclined/sloped belt system. Therefore, steps, if possible, need to be taken so that particles of all sizes have equal chances of being sampled.  
4.5.2 The number of samples and sample time is dependent upon the system, the precision required, the decisions that are to be made, the cost, and the degree of heterogeneity of the material (see Guides D5956 and D6311).  
4.5.3 In general, the ideal sampling location is nearest to the point of generation since temperature, oxidation, and air movement may change some samples with time.  
4.6 The practice does not address issues related to the heterogeneity of the sample.
SCOPE
1.1 This practice describes standard procedures for sampling waste on open and closed conveying systems and is applicable to any waste material that can be conveyed to a waste pile or container. The conveyor system can be a vertical (vertical lifts), sloped, or horizontal type.  
1.2 This practice is intended for particles and slurries, which can be sampled using scoop, dipper, or shovel type samplers.  
1.3 The practice is not intended for large size sample constituents, such as boulders, large rocks, and debris.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is a screening procedure for determining the presence of fuels containing aromatic compounds in soils. If a sample of the contaminant fuel is available for use in calibration, the approximate concentration of the fuel in the soil can be calculated. If the fuel type is known but a sample of the contaminant fuel is not available for calibration, an estimate of the contaminant fuel concentration can be calculated using average response factors based on composition of the fuel in the soil. If the composition of the contaminant fuel is unknown, a contaminant concentration cannot be calculated, and this practice can only be used only to indicate the presence or absence of fuel contamination.  
5.2 Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as crude oil, coal oil, and motor oil, can be determined by this practice. The quantitation limit for diesel fuel is about 75 mg/kg. Approximate quantitation limits for other aromatic-containing hydrocarbon materials that can be determined by this screening practice are given in Table 1. Quantitation limits for highly aliphatic materials, such as aviation gasoline and synthetic motor oil, are much higher than those for more aromatic materials, such as coal oil and diesel fuel.  
Note 1: The quantitation limits listed in Table 1 are estimated values because in this practice, the quantitation limit can be influenced by the particular fuel type and soil background. For information on how the values given in Table 1 were determined, see Appendix X1. Data generated during the development of this screening practice and other information pertaining to this practice can be found in the referenced research reports (1, 2).3  
5.3 When applying this practice to sites contaminated by diesel fuel, care should be taken in selecting the appropriate response factor from the list given in Table 2, with consideration given to whether or not t...
SCOPE
1.1 This practice is a screening procedure for assessing the presence of fuels containing aromatic compounds in soils. If a sample of the contaminant fuel is available, the concentration of the fuel in the soil can be determined. If the contaminant fuel type is known but a sample of the contaminant fuel is not available, an estimate of the concentration of the fuel in the soil can be made using average response factors based on composition of the fuel in the soil. If the kind of contaminant fuel is unknown, this screening method can be used to identify the presence of contamination.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    10 pages
    English language
  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is intended as a means for obtaining sequential extracts of a waste. The extracts may be used to estimate the release of certain constituents of the waste under the laboratory conditions described in this test method.  
4.2 This test method is not intended to provide extracts that are representative of the actual leachate produced from a waste in the field or to produce extracts to be used as the sole basis of engineering design.  
4.3 This test method is not intended to simulate site-specific leaching conditions. It has not been demonstrated to simulate actual disposal site leaching conditions.  
4.4 An intent of this test method is that the final pH of each of the extracts reflects the interaction of the extractant with the buffering capacity of the waste.  
4.5 An intent of this test method is that the water extractions reflect conditions where the waste is the dominant factor in determining the pH of the extracts.  
4.6 This test method produces extracts that are amenable to the determination of both major and minor constituents. When minor constituents are being determined, it is especially important that precautions are taken in sample storage and handling to avoid possible contamination of the samples.  
4.7 This test method has been tested to determine its applicability to certain inorganic components in the waste. This test method has not been tested for applicability to organic substances, volatile matter (see Note 3 in 5.15), or biologically active samples.  
4.8 The agitation technique, rate, liquid-to-solid ratio, and filtration conditions specified in the procedure may not be suitable for extracting all types of wastes (see Sections 7, 8, and the discussion in Appendix X1).
SCOPE
1.1 This test method is a procedure for the sequential leaching of a waste containing at least five percent solids to generate solutions to be used to determine the constituents leached under the specified testing conditions.  
1.2 This test method calls for the shaking of a known weight of waste with water of a specified purity and the separation of the aqueous phase for analysis. The procedure is conducted ten times in sequence on the same sample of waste and generates ten aqueous solutions.  
1.3 This test method is intended to describe the procedure for performing sequential batch extractions only. It does not describe all types of sampling and analytical requirements that may be associated with its application.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is intended to generate an extract with a concentration of the target analyte(s) representative of the expected release under the scenario simulated, and which can be compared with concentration levels acceptable in waste disposal, treatment, or production activities.  
5.2 The extraction conditions of the test method were chosen to simulate a potential disposal scenario to which the wastes may be exposed.  
5.3 One intent of this test method is that the amount of acid in the extraction fluids reflects the acid available from the leachate of a specific landfill where municipal and industrial wastes were co-disposed.6  
5.4 One intent of this test method is to not allow the pH of the extraction fluid to be lower than that of the leachate of a specific landfill where municipal and industrial wastes were co-disposed. Therefore, the pH of the extraction fluid was chosen with the following considerations:
(1) Not to be less than 4.93 ± 0.05 for the extraction of wastes with an acid neutralization capacity of less than the acid available in the total volume of extraction fluid used in the method (Extraction Fluid No. 1).
(2) At 2.88 ± 0.05, as defined by the pH of the acid, for the extraction of wastes with an acid neutralization capacity of more than the acid available in the extraction fluid used in the method (Extraction Fluid No. 2).  
5.5 The interpretation and use of the results of this test method are limited by the assumptions of a single co-disposal scenario and by the factors affecting the composition of a landfill leachate and chemical or other differences between a selected extraction fluid and the real landfill leachate.  
5.6 This test method may be affected by biological changes in the waste, and it is not designed to isolate or measure the effect of such processes.  
5.7 This test method produces extracts that are amenable to the determination of both minor and major constituents. When minor constituents are being determined,...
SCOPE
1.1 This test method is applicable to the extraction of samples of treated or untreated solid wastes or sludges, or solidified waste samples, to provide an indication of the leaching potential.  
1.2 This test method is intended to provide an extract for measurement of the concentration of the analytes of concern. The measured values may be compared against set or chosen acceptance levels in some applications.  
1.3 If the sole application of the test method is such a pass/fail comparison and a total analysis of the waste demonstrates that individual analytes are not present in the waste, or that the chosen acceptance concentration levels could not possibly be exceeded, the test method need not be run.  
1.4 If the sole application of the test method is such a pass/fail comparison and an analysis of any one of the liquid fractions of the extract indicates that the concentration of the target analyte is so high that, even after accounting for dilution from the other fractions of the extract, it would be equal to or above an acceptance concentration level, then the waste fails the test. In such a case it may not be necessary to analyze the remaining fractions of the extract.  
1.5 This test method is intended to provide an extract suitable for the measurement of the concentration of analytes that will not volatilize under the conditions of the test method.  
1.6 Presence of volatile analytes may be established if an analysis of the extract obtained using this test method detects the target volatile analyte. If its concentration is equal to or exceeds an acceptance level for that analyte, the waste fails the test. However, extract from this test method shall not be used to determine the concentration of volatile organic analytes.  
1.7 This test method is intended to describe only the procedure for performing a batch extraction. It does not describe all of the sampling and analytical requirements that may be associate...

  • Standard
    9 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is meant to allow for a rapid (24 h) index of a geomedia's sorption affinity for given solutes in environmental waters or leachates. A large number of samples may be run in parallel using this test method to determine a comparative ranking of those samples, based upon the amount of solute sorbed by the geomedia, or by various geomedia or leachate constituents. The 24 h time is used to make the test convenient and also to minimize microbial, light, or hydrolytic degradation which may be a problem in longer timed procedures. While Kd values are directly applicable for screening and comparative ranking purposes, their use in predictive field applications generally requires the assumption that Kd be a fixed value.  
5.2 While this test method may be useful in determining 24 h Kd values for nonvolatile organic constituents, interlaboratory testing has been carried out only for the nonvolatile inorganic species arsenic and cadmium (see Section 12). However, the procedure has been tested for single-laboratory precision with polychlorinated biphenyls (PCBs) and is believed to be useful for all stable and nonvolatile inorganic and organic constituents. This test method is not considered appropriate for volatile constituents.  
5.3 The 24 h time limit may be sufficient to reach a steady-state Kd; however, the calculated Kd value should be considered a non-equilibrium measurement unless steady-state has been determined. To report this determination as a steady-state Kd, this test method should be conducted for intermediate times (for example, 12, 18, and 22 h) to ensure that the soluble concentrations in the solution have reached a steady state by 24 h. If a test duration of greater than 24 h is required, refer to Test Method D4319 for an alternate procedure of longer duration.
SCOPE
1.1 This test method describes a procedure for determining the sorption affinity of waste solutes by unconsolidated geologic material in aqueous suspension. The waste solute may be derived from a variety of sources such as wells, underdrain systems, or laboratory solutions such as those produced by waste extraction tests like the Practice D3987 shake extraction method.  
1.2 This test method is applicable in screening and providing relative rankings of a large number of geomedia samples for their sorption affinity in aqueous leachate/geomedia suspensions. This test method may not simulate sorption characteristics that would occur in unperturbed geologic settings.  
1.3 While this procedure may be applicable to both organic and inorganic constituents, care must be taken with respect to the stability of the particular constituents and their possible losses from solution by such processes as degradation by microbes, light, hydrolysis, or sorption to material surfaces. This test method should not be used for volatile chemical constituents (see 6.1).  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 The elemental analysis of liquid hazardous waste is often important for regulatory and process-specific requirements. This test method provides the user an accurate, rapid method for trace and major element determinations.
SCOPE
1.1 This test method covers the determination of trace and major element concentrations by energy-dispersive X-ray fluorescence spectrometry (EDXRF) in liquid hazardous waste (LHW).  
1.2 This test method has been used successfully on numerous samples of aqueous and organic-based LHW for the determination of the following elements: Ag, As, Ba, Br, Cd, Cl, Cr, Cu, Fe, Hg, I, K, Ni, P, Pb, S, Sb, Se, Sn, Tl, V, and Zn.  
1.3 This test method is applicable for other elements (Si-U) not listed in 1.2.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
4.1 This practice is intended as a rapid means for obtaining an extract of solid waste. The extract may be used to estimate the release of constituents of the solid waste under the laboratory conditions described in this procedure.  
4.1.1 This practice is not intended to be used as a kinetic test to simulate weathering of ore, metal mining, and metallurgical processing wastes. For kinetic testing of ore, metal mining, and metallurgical processing wastes, refer to Test Method D5744 to determine release rates for constituents of interest. For static testing of metal mining ore and metal mining or metallurgical processing waste materials, refer to Test Methods E1915 and D6234. If the conditions of this practice are not suitable for the test material, Test Method E2242 may be used, if applicable to the ore or waste.  
4.2 This practice is not intended to provide an extract that is representative of the actual leachate produced from a solid waste in the field, or to produce extracts to be used as the sole basis of engineering design.  
4.3 This practice is not intended to simulate site-specific leaching conditions. It has not been demonstrated to simulate actual disposal site leaching conditions.  
4.4 The intent of this practice is that the final pH of the extract reflects the interaction of the extractant with the buffering capacity of the solid waste.  
4.5 The intent of this practice is that the water extraction simulates conditions where the solid waste is the dominant factor in determining the pH of the extract.  
4.6 The practice produces an extract that is amenable to the determination of both major and minor constituents. When minor constituents are being determined, it is especially important that precautions are taken in sample storage and handling to avoid possible contamination of the samples.  
4.6.1 This practice has been tested to determine its applicability to certain inorganic components in metal mining and metallurgical processing wastes.  
4....
SCOPE
1.1 This practice covers a procedure for leaching of solid waste to obtain an aqueous solution to be used to determine the constituents leached under the specified testing conditions.  
1.1.1 This practice includes a procedure for the shake leaching of metal mining ore, waste rock, or metallurgical processing waste containing at least 80 % dry solids (≤20 % moisture) in order to generate a solution to be used to determine the inorganic constituents leached under the specified testing conditions and for regulatory jurisdictions requiring a water leach practice.  
1.2 This practice provides for the shaking of a known mass of waste with water of specified composition and the separation of the aqueous phase for analysis.  
1.2.1 This practice is intended to describe the procedure for performing single-batch extractions only. It does not describe all types of sampling, sample preservation, and analytical requirements that may be associated with its application.  
1.3 The values stated in SI units are to be regarded as standard. Values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 This compilation of methods is intended for use by those in the waste management and related industries to determine the presence of cyanides.
SCOPE
1.1 This practice is applicable to the screening of cyanides in waste liquids, sludges, semisolids, and solids. The following screening methods are included:    
Sections  
Method A—Chloramine T  
13 – 15  
Method B—Prussian Blue  
16 – 18  
Method C—Cyanide Test Paper  
19 – 21  
Method D—Gas Detector Tube  
22 – 26  
Method E—Ion Selective Electrode  
27 – 31  
1.2 This practice is designed and intended as a compilation of screening tests to complement more sophisticated quantitative analytical techniques that may be used to determine cyanide concentration. This practice provides the user the option and the ability to “screen” waste for potentially hazardous levels of cyanide when the more sophisticated techniques are not available and the total waste composition is unknown.  
1.3 The values stated in SI units are to be regarded as the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard information is given in Section 8 and 18.5.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
5.1 Environmental data are often required for making regulatory and programmatic decisions. Decision makers must determine whether the levels of assurance associated with the data are sufficient in quality for their intended use.  
5.2 Data generation efforts involve three parts: development of DQOs and subsequent project plan(s) to meet the DQOs, implementation and oversight of the project plan(s), and assessment of the data quality to determine whether the DQOs were met.  
5.3 To determine the level of assurance necessary to support the decision, an iterative process must be used by decision makers, data collectors, and users. This practice emphasizes the iterative nature of the process of DQO development. Objectives may need to be reevaluated and modified as information related to the level of data quality is gained. This means that DQOs are the product of the DQO process and are subject to change as data are gathered and assessed.  
5.4 This practice defines the process of developing DQOs. Each step of the planning process is described.  
5.5 This practice emphasizes the importance of communication among those involved in developing DQOs, those planning and implementing the sampling and analysis aspects of environmental data generation activities, and those assessing data quality.  
5.6 The impacts of a successful DQO process on the project are as follows: (1) a consensus on the nature of the problem and the desired decision shared by all the decision makers, (2) data quality consistent with its intended use, (3) a more resource-efficient sampling and analysis design, (4) a planned approach to data collection and evaluation, (5) quantitative criteria for knowing when to stop sampling, and (6) known measure of risk for making an incorrect decision.
SCOPE
1.1 This practice covers the process of development of data quality objectives (DQOs) for the acquisition of environmental data. Optimization of sampling and analysis design is a part of the DQO process. This practice describes the DQO process in detail. The various strategies for design optimization are too numerous to include in this practice. Many other documents outline alternatives for optimizing sampling and analysis design. Therefore, only an overview of design optimization is included. Some design aspects are included in the practice's examples for illustration purposes.  
1.2 DQO development is the first of three parts of data generation activities. The other two aspects are (1) implementation of the sampling and analysis strategies, see Guide D6311; and (2) data quality assessment, see Guide D6233.  
1.3 This guide should be used in concert with Practices D5283, D6250, and Guide D6044. Practice D5283 outlines the quality assurance (QA) processes specified during planning and used during implementation. Guide D6044 outlines a process by which a representative sample may be obtained from a population, identifies sources that can affect representativeness, and describes the attributes of a representative sample. Practice D6250 describes how a decision point can be calculated.  
1.4 Environmental data related to waste management activities include, but are not limited to, the results from the sampling and analyses of air, soil, water, biota, process or general waste samples, or any combinations thereof.  
1.5 The DQO process is a planning process and should be completed prior to sampling and analysis activities.  
1.6 This practice presents extensive requirements of management, designed to ensure high-quality environmental data. The words “must” and “shall” (requirements), “should” (recommendation), and “may” (optional), have been selected carefully to reflect the importance placed on many of the statements in this practice. The extent to which all requirements will be met remains a matter of technical judgment.  
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included ...

  • Standard
    17 pages
    English language

SIGNIFICANCE AND USE
5.1 The calorific value, or heat of combustion, is a measure of the energy available from a fuel. Knowledge of this value is essential in assessing the commercial worth of the fuel and to provide the basis of contract between producer and user.
SCOPE
1.1 This test method covers the determination of the gross calorific value of a prepared analysis sample of solid forms of refuse-derived fuel (RDF) by the bomb calorimeter method.  
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific cautionary and precautionary statements, see 6.9 and Section 8.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
5.1 This guide provides guidance to persons managing or responsible for designing sampling and analytical plans for determining whether sample compositing may assist in more efficiently meeting study objectives. Samples must be composited properly, or useful information on contamination distribution and sample variance may be lost.  
5.2 The procedures described for mixing samples and obtaining a representative subsample are broadly applicable to waste sampling where it is desired to transport a reduced amount of material to the laboratory. The mixing and subsampling sections provide guidance to persons preparing sampling and analytical plans and field personnel.  
5.3 While this guide generally focuses on solid materials, the attributes and limitations of composite sampling apply equally to static liquid samples.
SCOPE
1.1 Compositing and subsampling are key links in the chain of sampling and analytical events that must be performed in compliance with project objectives and instructions to ensure that the resulting data are representative. This guide discusses the advantages and appropriate use of composite sampling, field procedures and techniques to mix the composite sample, and procedures to collect an unbiased and precise subsample(s) from a larger sample. It discusses the advantages and limitations of using composite samples in designing sampling plans for characterization of wastes (mainly solid) and potentially contaminated media. This guide assumes that an appropriate sampling device is selected to collect an unbiased sample.  
1.2 The guide does not address: where samples should be collected (depends on the objectives) (see Guide D6044), selection of sampling equipment, bias introduced by selection of inappropriate sampling equipment, sample collection procedures or collection of a representative specimen from a sample, or statistical interpretation of resultant data and devices designed to dynamically sample process waste streams. It also does not provide sufficient information to statistically design an optimized sampling plan, or determine the number of samples to collect or calculate the optimum number of samples to composite to achieve specified data quality objectives (see Practice D5792). Standard procedures for planning waste sampling activities are addressed in Guide D4687.  
1.3 The sample mixing and subsampling procedures described in this guide are considered inappropriate for samples to be analyzed for volatile organic compounds. Volatile organics are typically lost through volatilization during sample collection, handling, shipping, and laboratory sample preparation unless specialized procedures are used. The enhanced mixing described in this guide is expected to cause significant losses of volatile constituents. Specialized procedures should be used for compositing samples for determination of volatiles such as combining directly into methanol (see Guide D4547).  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    7 pages
    English language

SIGNIFICANCE AND USE
5.1 The determination of total moisture is important for assessing the fuel quality. Water content will affect the heating value of fuels directly and can contribute to instability in the operation of an industrial furnace or adversely impact performance in other applications. Additionally, high water content can present material handling and storage problems during winter months or in cold environments.
SCOPE
1.1 This test method covers the determination by Karl Fischer (KF) titrimetry of total moisture in solid or liquid hazardous waste fuels used by industrial furnaces.  
1.2 This test method has been used successfully on numerous samples of hazardous waste fuel composed of solvents, spent oils, inks, paints, and pigments. The range of applicability for this test method is between 1.0 and 100 %; however, this evaluation was limited to samples containing approximately 5 to 50 % water.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 The U.S. Environmental Protection Agency Regulations, 40 CFR 266, require that boilers, cement kilns, and other industrial furnaces utilizing waste-derived fuel adhere to specific guidelines in assessing potential metals emissions. A common approach for estimating potential emissions is performing total metals analysis on all feed stream materials. This practice describes a multi-stage microwave-assisted digestion procedure that solubilizes trace elements for spectroscopic analyses.
SCOPE
1.1 This practice describes the multi-stage microwave digestion of typical industrial furnace feed stream materials using nitric, hydrofluoric, hydrochloric, and boric acids for the subsequent determination of trace metals.  
1.2 This practice has been used successfully on samples of coal, coke, cement raw feed materials, and waste-derived fuels composed primarily of waste paint-related material in preparation for measuring the following trace elements: Ag, As, Ba, Be, Cd, Cr, Hg, Pb, Sb, and Tl. This practice may be applicable to elements not listed above.  
1.3 This practice is also effective for other waste materials (for example, fly ash, foundry sand, alum process residue, cement kiln dust, etc.).  
1.4 The values stated in SI units are to be regarded as standard. Other units of measurement in parentheses in this standard are informational.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 8.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 Bucket augers (Fig. 1) are relatively inexpensive, readily available, available in different types depending on the media to be sampled, and most can be easily operated by one person. They collect a reasonably cylindrical but disturbed sample of surface or subsurface soil or waste. They are generally not suited for sampling gravelly or coarser soil and are unsuitable for sampling rock. There are other designs of hand augers, such as the Edelman auger, used to retrieve difficult materials such as waste, sands, peat, and mud.
FIG. 1 Bucket Auger  
5.2 Bucket augers are commonly used equipment because they are inexpensive to operate, especially compared to powered equipment (that is, direct push and drill rigs). When evaluated against screw augers (Guide D4700), bucket augers generally collect larger samples with less chance of mixing with soil from shallow depths because the sample is retained within the auger bucket. Bucket augers are commonly used to depths of 3 m but have been used to much greater depths depending upon the soil or waste characteristics. In general, bucket augers can maintain open holes in unsaturated soils and saturated clay soils below the water table. Saturated sands will cave below the water table and perched zones and cohesionless dry sands may also cave. The sampling depth is limited by the force required to rotate the auger and the depth at which the bore hole collapses (unless bore casings or liners are used).  
5.3 Bucket augers may not be suitable for the collection of samples for determination of volatile organic compounds (VOCs) because the sample is disturbed and exposed to atmosphere during the collection process, which may lead to losses resulting in a chemically unrepresentative sample.  
5.4 If VOC analysis is required, the bucket auger is used to reach the desired sample depth, a planer auger can be used to clean the base of the hole, and a hammered drive tube sampler (Fig. 2) can be used at the bottom of the hole. Drive ...
SCOPE
1.1 This practice describes the procedures and equipment used to collect surface and subsurface soil and contaminated media samples for chemical analysis using a hand-operated bucket auger (sometimes referred to as a barrel auger). Several types of bucket augers exist and are designed for sampling various types of soil. All bucket augers collect disturbed samples. Bucket augers can also be used to auger to the desired sampling depth and then, using a core-type sampler, collect a relatively undisturbed sample suitable for chemical analysis.  
1.2 This practice does not cover the use of large 300 mm or greater diameter bucket augers mechanically operated by large drill rigs or similar equipment, such as those described in Practice D1452/D1452M, paragraph 5.2.4. Practice D1452/D1452M on auger borings refers to this hand auger included in Practice D6907 as a barrel auger.  
1.3 Refer to Guides D4700 and D6232 for information on other hand samplers. The bucket auger is often used for shallow surface soil sampling, but there are many other types of handheld augers, flight, screw, rotary powered, and agricultural push tube samplers. Practice D1452/D1452M addresses larger powered solid stem flight auger systems.  
1.4 This standard does not address soil samples obtained with mechanical drilling, direct push, and sonic machines (refer to Guides D6286/D6286M and D6169/D6169M) or for collecting cores from submerged sediments (Guide D4823).  
1.5 This practice does not address sampling objectives (see Practice D5792), general sample planning (see Guide D4687), and sampling design (for example, where to collect samples and what depth to sample (see Guide D6044)). Sampling for volatile organic compounds (see Guide D4547), equipment cleaning and decontamination (see Practice D5088), sample handling after collection such as compositing and subsampling (see Guide D6051), and sample preservation (Guide D4220/D4220M) are used in this s...

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 Search sampling strategies have found wide utility in geologic exploration where drilling is required to detect subsurface mineral deposits, such as when drilling for oil and gas. Using such strategies to search for buried wastes and subsurface contaminants, including volatile organic compounds, is a logical extension of these strategies.  
4.2 Systematic sampling strategies are often the most cost-effective method for searching for hot spots.  
4.3 This practice may be used to determine the risk of missing a hot spot of specified size and shape given a specified sampling pattern and sampling density.  
4.4 This practice may be used to determine the smallest hot spot that can be detected with a specified probability and given sampling density.  
4.5 This practice may be used to select the optimum grid sampling strategy (that is, sampling pattern and density) for a specified risk of not detecting a hot spot.  
4.6 By using the algorithms given in this practice, one can balance the cost of sampling versus the risk of missing a hot spot.  
4.7 Search sampling patterns may also be used to optimize the locations of additional groundwater monitoring wells or vadose zone monitoring devices.
SCOPE
1.1 This practice provides equations and nomographs, and a reference to a computer program, for calculating probabilities of detecting hot spots (that is, localized areas of soil or groundwater contamination) using point-net (that is, grid) search patterns. Hot spots, more generally referred to as targets, are presumed to be invisible on the ground surface. Hot spots may include former surface impoundments and waste disposal pits, as well as contaminant plumes in groundwater or the vadose zone.  
1.2 For purposes of calculating detection probabilities, hot spots or buried contaminants are presumed to be elliptically shaped when projected vertically to the ground surface, and search patterns are square, rectangular, or rhombic. Assumptions about the size and shape of suspected hot spots are the primary limitations of this practice, and must be judged by historical information. A further limitation is that hot spot boundaries are usually not clear and distinct.  
1.3 In general, this practice should not be used in lieu of surface geophysical methods for detecting buried objects, including underground utilities, where such buried objects can be detected by these methods (see Guide D6429).  
1.4 Search sampling would normally be conducted during preliminary investigations of hazardous waste sites or hazardous waste management facilities (see Guide D5730). Sampling may be conducted by drilling or by direct-push methods. In contrast, guidance on sampling for the purpose of making statistical inferences about population characteristics (for example, contaminant concentrations) can be found in Guide D6311.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    8 pages
    English language
  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
3.1 The procedures covered in this guide are general and provide the user with information helpful for writing sampling plans, safety plans, labeling and shipping procedures, chain-of-custody procedures, general sampling procedures, general cleaning procedures, and general preservation procedures.  
3.2 For purposes of this guide, it is assumed that the user has knowledge of the waste being sampled and the possible safety hazards.  
3.3 This guide is not to be used when sampling sites or wastes when safety hazards are unknown. In such cases, the user shall use other more appropriate procedures.
SCOPE
1.1 This guide provides information for formulating and planning the many aspects of waste sampling (see 1.2) that are common to most waste sampling situations.  
1.2 The aspects of sampling that this guide addresses are as follows:    
Section  
Safety plans  
4  
Sampling plans  
5  
Quality assurance considerations  
6  
General sampling considerations  
7  
Preservation and containerization  
8  
Cleaning equipment  
9  
Packaging, labeling, and shipping procedures  
10  
Chain-of-custody procedure  
11  
1.3 This guide does not provide comprehensive sampling procedures for these aspects, nor does it serve as a guide to any specific application. It is the responsibility of the user to ensure that the procedures used are proper and adequate.  
1.4 Units—The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For more specific precautionary statements see 3.2, 3.3, and Section 4.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    8 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended for use in collecting samples of unconsolidated solid materials from drums or similar containers, including those that are unstable, ruptured, or compromised otherwise. Special handling procedures (for example, remote drum opening, overpressurized drum opening, drum deheading, etc.) are described in EPA/600/2-86/013, Drum Handling Practices at Hazardous Waste Sites.
SCOPE
1.1 This practice covers typical equipment and methods for collecting samples of unconsolidated solids in drums or similar containers. These methods are adapted specifically for sampling drums having a volume of 110 U.S. gal (416 L) or less. These methods are applicable to hazardous material, product, or waste. Specific sample collection and handling requirements should be described in the site-specific work plan.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
4.1 The intended use of this guide is to provide practical assistance in the development of an optimized sampling design. This standard describes or discusses:  
4.1.1 Sampling design selection criteria,  
4.1.2 Factors impacting the choice of a sampling design,  
4.1.3 Selection of a sampling design,  
4.1.4 Techniques for optimizing candidate designs, and  
4.1.5 The criteria for evaluating an optimized sampling design.  
4.2 Within a formal USEPA data generation activity, the planning process or data quality objectives (DQOs) development is the first step. The second and third are the implementation of the sampling and analysis design and the data quality assessment. Within the DQO planning process, the selection and optimization of the sampling design is the last step, and therefore, the culmination of the DQO process. The preceding steps in the DQO planning process address:  
4.2.1 The problem that needs to be addressed,  
4.2.2 The possible decisions,  
4.2.3 The data input and associated activities,  
4.2.4 The boundaries of the study,  
4.2.5 The development of decision rules, and  
4.2.6 The specified the limits on decision error.  
4.3 This guide is not intended to address the aspects of the planning process for development of the project objectives. However, the project objectives must be outlined and communicated to the design team, prior to the selection and optimization of the sample design.  
4.4 This guide references statistical aspects of the planning and implementation process and includes an appendix for the statistical calculation of the optimum number of samples for a given sampling design.  
4.5 This guide is intended for those who are responsible for making decisions about environmental waste management activities.
SCOPE
1.1 This document provides practical guidance on the selection and optimization of sample designs in waste management sampling activities, within the context of the requirements established by the data quality objectives or other planning process.  
1.2 This document (1) provides guidance for selection of sampling designs; (2) outlines techniques to optimize candidate designs; and (3) describes the variables that need to be balanced in choosing the final optimized design.  
1.3 The contents of this guide are arranged by section as follows:
1.  
Scope  
2.  
Referenced Documents  
3.  
Terminology  
4.  
Significance and Use  
5.  
Summary of Guide  
6.  
Factors Affecting Sampling Design Selection  
6.1  
Sampling Design Performance Characteristics  
6.2  
Regulatory Considerations  
6.3  
Project Objectives  
6.4  
Knowledge of the Site  
6.5  
Physical Sample Issues  
6.6  
Communication with the Laboratory  
6.7  
Analytical Turn Around Time  
6.8  
Analytical Method Constraints  
6.9  
Health and Safety  
6.10  
Budget/Cost Considerations  
6.11  
Representativeness  
7.  
Initial Design Selection  
8.  
Optimization Criteria  
9.  
Optimization Process  
9.2  
Practical Evaluation of Design Alternatives  
9.3  
Statistical and Cost Evaluation  
10.  
Final Selection  
Annex A1  
Types of Sampling Designs  
A1.1  
Commonly Used Sampling Designs  
A1.2  
Sampling Design Tools  
A1.3  
Combination Sample Designs  
Appendix X1. Additional References  
Appendix X2. Choosing Analytical Method Based on Variance and Cost  
Appendix X3. Calculating the Number of Samples: A Statistical Treatment  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standa...

  • Guide
    25 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method is useful in identifying the common solvent constituents in hazardous waste samples. This test method is designed to support field or site assessments, recycling operations, plant operations, or pollution control programs.
SCOPE
1.1 This test method is used to determine qualitatively and quantitatively the presence of the following compounds in waste samples using gas chromatography. This test method is intended for use as a screening method with a typical reporting level of 0.1 %.    
Dichodifluoromethane  
Tetrahydrofuran  
Trichlorofluoromethane  
Acetone  
1,1,2-Trichloro-1,2,2-
trifluoroethane  
Methyl Ethyl Ketone
MIBK  
Methanol  
Cyclohexanone  
Ethanol  
Ethyl Acetate  
Isopropanol  
Propyl Acetate  
n-Propanol  
Butyl Acetate  
Isobutanol  
Benzene  
n-Butanol  
Toluene  
tert-Butanol  
Ethylbenzene  
Methylene Chloride  
Xylenes  
Chloroform  
Styrene  
Carbon Tetrachloride  
Chlorobenzene  
1,1-Dichloroethane  
Dichlorobenzenes  
1,2-Dichloroethane  
Nitrobenzene  
1,2-Dichloropropane  
Fluorobenzene  
1,1-Dichloroethylene  
n-Propyl Benzene    
1,2-Dichloroethene  
Isopropyl Benzene  
1,1,1-Trichloroethane  
Isobutyl Benzene  
Tetrachloroethylene  
n-Butyl Benzene    
Trichloroethylene  
2-Ethoxyethanol  
Tetrachloroethane  
2-Butoxyethanol  
Cyclopentane  
2-Ethoxyethanol Acetate  
Pentane  
2-Methoxyethanol  
Hexane  
Bromoform  
Heptane  
Carbitol  
Cyclohexane  
Ethyl Ether  
Isooctane  
1,4-Dioxane  
Nitropropane  
Diacetone Alcohol  
Ethanolamine  
Acetonitrile  
Nitromethane  
Pyridine  
Ethylene Chloride  
Toluidine  
Benzyl Chloride  
Ethylene Glycol  
Propylene Glycol  
1.1.1 This compound list is a compilation of hazardous solvents and other constituents that are commonly seen in hazardous waste samples.  
1.2 The scope of this test method may be expanded to include other volatile and semivolatile organic constituents such as but not limited to those described below, provided the intended use data quality objectives including sampling, recovery, and analytic data quality are demonstrated as satisfied by the user.  
1.2.1 Hydrocarbon mixtures such as kerosene and mineral spirits.  
1.2.2 High-boiling organics, defined here as compounds which boil above n-Hexadecane.  
1.2.3 Other organics that the analyst is able to identify, either through retention time data or gas chromatography/mass spectrometric (GC/MS) analysis.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    9 pages
    English language
  • Standard
    9 pages
    English language

SIGNIFICANCE AND USE
5.1 Often during environmental investigations, soils are analyzed after being collected from the surface, the vadose zone (Terminology D653), and sometimes from below the groundwater table to identify and quantify the presence of a chemical contaminant. A contaminant is a substance that is typically hazardous and either is not normally present or that occurs naturally but is of an uncharacteristically high concentration (Guide D4687). A three-dimensional spatial array of samples can often provide information as to the source and route(s) of migration of the contaminant. The resultant information is used to direct remedial and corrective actions or can be used for monitoring purposes. Obtaining a soil sample with a core barrel sampler involves driving this device into the ground and then retrieving it for sample processing. Several methods for advancing a core barrel are generally acceptable (for example, Test Method D1586; Practices D1587, D3550, and D6151; Guides D5784, D5875, D5876, D6169, and D6282). Drilling methods that use drilling fluids (liquids or air) should be avoided because they are more susceptible to cross-contamination (Guide D6286) (see 6.1.6).  
5.2 If samples are to be collected for the determination of per- and poly-fluorinated alkyl substances (PFAS), all sampling equipment should be made of fluorine-free materials. Other considerations for PFAS sampling may exist but are beyond the scope of this standard.
SCOPE
1.1 This practice covers procedures for obtaining soils from core barrel samplers for chemical and physical analysis, with an emphasis on the collection and handling procedures that maintain the representativeness of the chemical contaminants of concern. Core barrel samplers are initially empty (hollow) until they are pushed into the ground to collect and retrieve a cylindrical soil sample with minimal disturbance. The selection of equipment and the sample handling procedures are dependent on the soil properties, the depth of sampling, and the general properties of the chemical contaminants of concern, that is, volatile organic compounds, semi-volatile organic compounds, and inorganic constituents. The sampling procedures described are designed to maintain representative concentrations of the contaminants regardless of their physical state(s), that is, solid, liquid, or gas.  
1.2 This practice covers soil samplers used in Guide D6169 on soils and rock sampling and included in Guide D6232 for waste sampling. Guide D6169 provides additional information on samplers and procedures that will preserve representative contaminate concentrations. Guide D6282 is on direct-push soil samplers that are most frequently used for environmental work. Guide D4547 addresses special sampling of soils for volatile compounds. This standard does not include sediment samplers in Guide D4823, but the same principles may apply to handling of those cores. Guide D4700 includes information on shallow manual push soil samplers.  
1.3 Five general types of core barrel samplers are discussed in this practice: split-barrel, soil corer, ring-lined barrel, thin-walled tube, and solid-barrel samplers.  
1.4 This document does not cover all the core barrel devices that are available for the collection of soil samples.  
1.5 The procedures described may or may not be applicable to handling of samples for assessing certain geotechnical properties, for example, soil porosity.
Note 1: Prior to commencement of any intrusive exploration, the site should be checked for underground utilities.  
1.6 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.  
1.7 This standard does not purpo...

  • Standard
    9 pages
    English language
  • Standard
    9 pages
    English language

SIGNIFICANCE AND USE
4.1 This guide defines the meaning of a representative sample, as well as the attributes the sample(s) needs to have in order to provide a valid inference from the sample data to the population.  
4.2 This guide also provides a process to identify the sources of error (both systematic and random) so that an effort can be made to control or minimize these errors. These sources include sampling error, measurement error, and statistical bias.  
4.3 When the objective is limited to the taking of a representative (physical) sample or a representative set of (physical) samples, only potential sampling errors need to be considered. When the objective is to make an inference from the sample data to the population, additional measurement error and statistical bias need to be considered.  
4.4 This guide does not apply to the cases where the taking of a nonrepresentative sample(s) is prescribed by the study objective. In that case, sampling approaches such as judgment sampling or biased sampling can be taken. These approaches are not within the scope of this guide.  
4.5 Following this guide does not guarantee that representative samples will be obtained. But failure to follow this guide will likely result in obtaining sample data that are either biased or imprecise, or both. Following this guide should increase the level of confidence in making the inference from the sample data to the population.  
4.6 This guide can be used in conjunction with the DQO process (see Practice D5792).  
4.7 This guide is intended for those who manage, design, and implement sampling and analytical plans for waste management and contaminated media.
SCOPE
1.1 This guide covers the definition of representativeness in environmental sampling, identifies sources that can affect representativeness (especially bias), and describes the attributes that a representative sample or a representative set of samples should possess. For convenience, the term “representative sample” is used in this guide to denote both a representative sample and a representative set of samples, unless otherwise qualified in the text.  
1.2 This guide outlines a process by which a representative sample may be obtained from a population. The purpose of the representative sample is to provide information about a statistical parameter(s) (such as mean) of the population regarding some characteristic(s) (such as concentration) of its constituent(s) (such as lead). This process includes the following stages: (1) minimization of sampling bias and optimization of precision while taking the physical samples, (2) minimization of measurement bias and optimization of precision when analyzing the physical samples to obtain data, and (3) minimization of statistical bias when making inferences from the sample data to the population. While both bias and precision are covered in this guide, major emphasis is given to bias reduction.  
1.3 This guide describes the attributes of a representative sample and presents a general methodology for obtaining representative samples. It does not, however, provide specific or comprehensive sampling procedures. It is the user's responsibility to ensure that proper and adequate procedures are used.  
1.4 The assessment of the representativeness of a sample is not covered in this guide since it is not possible to ever know the true value of the population.  
1.5 Since the purpose of each sampling event is unique, this guide does not attempt to give a step-by-step account of how to develop a sampling design that results in the collection of representative samples.  
1.6 Appendix X1 contains two case studies which discuss the factors for obtaining representative samples.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicabi...

  • Guide
    11 pages
    English language
  • Guide
    11 pages
    English language

SIGNIFICANCE AND USE
5.1 Although many technical papers address topics important to efficient and accurate sampling investigations (DQOs, study design, QA/QC, data assessment; see Guides D4687, D5730, D6009, D6051, and Practice D5283), the selection and use of appropriate sampling equipment is assumed or omitted.  
5.2 The choice of sampling equipment can be crucial to the task of collecting a sample appropriate for the intended use.  
5.3 When a sample is collected, all sources of potential bias should be considered, not only in the selection and use of the sampling device, but also in the interpretation and use of the data generated. Some major considerations in the selection of sampling equipment for the collection of a sample are listed below:  
5.3.1 The ability to access and extract from every relevant location in the target population,  
5.3.2 The ability to collect a sufficient mass of sample such that the distribution of particle sizes in the population are represented, and  
5.3.3 The ability to collect a sample without the addition or loss of constituents of interest.  
5.4 The characteristics discussed in 5.3 are particularly important in investigations when the target population is heterogeneous, such as when particle sizes vary, liquids are present in distinct phases, a gaseous phase exists, or materials from different sources are present in the population. The consideration of these characteristics during the equipment selection process will enable the data user to make appropriate statistical inferences about the target population based on the sampling results.  
5.5 If samples are to be collected for the determination of per- and poly-fluorinated alkyl substances (PFAS), all sampling equipment should be made of fluorine-free materials. Other considerations for PFAS sampling may exist but are beyond the scope of this standard.
SCOPE
1.1 This guide covers criteria which should be considered when selecting sampling equipment for collecting environmental and waste samples for waste management activities. This guide includes a list of equipment that is used and is readily available. Many specialized sampling devices are not specifically included in this guide. However, the factors that should be weighed when choosing any piece of equipment are covered and remain the same for the selection of any piece of equipment. Sampling equipment described in this guide includes automatic samplers, pumps, bailers, tubes, scoops, spoons, shovels, dredges, coring, augering, passive, and vapor sampling devices. The selection of sampling locations is outside the scope of this guide.  
1.1.1 Table 1 lists selected equipment and its applicability to sampling matrices, including water (surface and ground), sediments, soils, liquids, multi-layered liquids, mixed solid-liquid phases, and consolidated and unconsolidated solids. The guide does not specifically address the collection of samples of any suspended materials from flowing rivers or streams. Refer to Guide D4411 for more information.  
1.2 Table 2 presents the same list of equipment and its applicability for use based on compatibility of sample and equipment; volume of the sample required; physical requirements such as power, size, and weight; ease of operation and decontamination; and whether it is reusable or disposable.  
1.3 Table 3 provides the basis for selection of suitable equipment by the use of an index.  
1.4 Lists of advantages and disadvantages of selected sampling devices and line drawings and narratives describing the operation of sampling devices are also provided.  
1.5 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard. ...

  • Guide
    44 pages
    English language
  • Guide
    44 pages
    English language

SIGNIFICANCE AND USE
4.1 This guide is suitable for sampling heterogeneous wastes.  
4.2 The focus of this guidance is on wastes; however, the approach described in this guide may be applicable to non-waste populations as well.  
4.3 Sections 5 – 10 describe a guide for the sampling of heterogeneous waste according to project objectives. Appendix X1 describes an application of the guide to heterogeneous wastes. The user is strongly advised to read Annex A1 prior to reading and employing Sections 5 – 10 of this guide.  
4.4 Annex A1 contains an introductory discussion of heterogeneity, stratification, and the relationship of samples and populations.  
4.5 This guide is intended for those who manage, design, or implement sampling and analytical plans for the characterization of heterogeneous wastes.
SCOPE
1.1 This guide is a practical, nonmathematical discussion for heterogeneous waste sampling strategies. This guide is consistent with the particulate material sampling theory as well as inferential statistics, and may serve as an introduction to the statistical treatment of sampling issues.  
1.2 This guide does not provide comprehensive sampling procedures, nor does it serve as a guide to any specification. It is the responsibility of the user to ensure appropriate procedures are used.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    17 pages
    English language
  • Guide
    17 pages
    English language

SIGNIFICANCE AND USE
5.1 This is a performance-based method, and modifications are allowed to improve performance.  
5.1.1 Due to the rapid development of newer instrumentation and column chemistries, changes to the analysis described in this standard are allowed as long as better or equivalent performance data result. Any modifications shall be documented and performance data generated. The user of the data generated by this standard shall be made aware of these changes and given the performance data demonstrating better or equivalent performance.  
5.2 TDG is a Schedule 2 compound under the Chemical Weapons Convention (CWC).6 Schedule 2 chemicals include those that are precursors to chemical weapons, chemical weapons agents, or have a number of other non-military commercial uses. Schedule 2 chemicals can also be found in applications unrelated to chemical weapons. These chemicals are used as ingredients to produce insecticides, herbicides, lubricants, and some pharmaceutical products. TDG is a mustard gas precursor and a degradant as well as an ingredient in water-based inks, ballpoint pen inks, dyes, and some pesticides.  
5.3 This method has been investigated for use on surface wipes. TDG is also a human metabolite resulting from sulfur mustard exposure but this method has not been investigated for such determinations.
SCOPE
1.1 This procedure details the determination of thiodiglycol (TDG), also known as 2,2’-thiobis-ethanol, on wipes with 3,3’-thiodipropanol (TDP) as the surrogate. This method is based upon solvent extraction of wipes by either sonication or a pressurized fluid extraction (PFE) technique as an alternative option. The extract is filtered, concentrated, and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). TDG is qualitatively and quantitatively determined.  
1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 The method detection limit (MDL)2 and reporting range3 for TDG are listed in Table 1.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    10 pages
    English language
  • Standard
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended for use in collecting samples of contaminated soils and similar materials.  
5.2 Scoops are used primarily for collecting samples near the surface. Subsurface samples can be obtained by first removing higher layers using a shovel or other suitable equipment and collecting the sample with the scoop.  
5.3 Because of their simplicity, scoops are useful in taking samples of waste materials where decontamination or disposal is a problem with other types of sampling equipment. Scoops are also suitable for use in rapid screening programs, pilot studies, and other semi-quantitative investigations.  
5.4 Samples should be collected in accordance with an appropriate work plan (see Practice D5283 and Guide D4687).
SCOPE
1.1 This practice covers the method and equipment used to collect surface and near-surface samples of soils and physically similar materials using a scoop.  
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    2 pages
    English language
  • Standard
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 TDG is a Schedule 2 compound under the Chemical Weapons Convention (CWC). Schedule 2 chemicals include those that are precursors to chemical weapons, chemical weapons agents, or have a number of other commercial uses. They are used as ingredients to produce insecticides, herbicides, lubricants, and some pharmaceutical products. Schedule 2 chemicals can be found in applications unrelated to chemical weapons. TDG is both a mustard gas precursor and a degradant as well as an ingredient in water-based inks, ballpoint pen inks, dyes, and some pesticides.5  
5.2 This method has been investigated for use with soil.
SCOPE
1.1 This procedure covers the determination of thiodiglycol (TDG) in soil using pressurized fluid extraction (PFE). A commercially available PFE system2 is used, followed by analysis using liquid chromatography (LC), and detected with tandem mass spectrometry (MS/MS). TDG is qualitatively and quantitatively determined by this method. This method adheres to single reaction monitoring (SRM) mass spectrometry.  
1.2 The method detection limit (MDL) and reporting range for TDG are listed in Table 1.  
1.2.1 The MDL is determined following the Code of Federal Regulations, 40 CFR Part 136, Appendix B.  
1.2.2 The reporting limit (RL) is calculated from the concentration of the Level 1 calibration standard as shown in Table 4. The RL for this method is 200 ppb. Reporting range concentrations are calculated from Table 4 concentrations assuming a 5 μL injection of the lowest level calibration standard, 5 g sample, and a 2 mL final extract volume.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    9 pages
    English language
  • Standard
    9 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended for use in collecting samples of single and multilayered liquids, with or without solids, from drums or similar containers, including those that are unstable, ruptured, or otherwise compromised. Special handling procedures (for example, remote drum opening, over-pressurized drum opening, drum deheading, etc.) are described in Drum Handling Practices at Hazardous Waste Sites.
SCOPE
1.1 This practice covers typical equipment and methods for collecting samples of single or multilayered liquids, with or without solids, in drums or similar containers. These methods are adapted specifically for sampling drums having a volume of 110 gal (416 L) or less. These methods are applicable to hazardous material, product, or waste. Specific sample collection and handling requirements should be described in the site-specific work plan.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 7.2.4, 7.2.7.1, and Notes 1 and 2.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is applicable to sampling liquid wastes and other stratified liquids. The COLIWASA is used to obtain a vertical column of liquid representing an accurate cross section of the sampled material. To obtain a representative sample of stratified liquids, the COLIWASA should be open at both ends so that material flows through it as it is slowly lowered to the desired sampling depth. The COLIWASA must not be lowered with the stopper in place. Opening the stopper after the tube is submerged will cause material to flow in from the bottom layer only, resulting in gross over-representation of that layer.  
5.2 This practice is to be used by personnel acquiring samples.  
5.3 This practice should be used in conjunction with Guide D4687 which covers sampling plans, safety, QA, preservation, decontamination, labeling, and chain-of-custody procedures; Practice D5088 which covers decontamination of field equipment used at waste sites; Practice D5283 which covers project specifications and practices for environmental field operations; and Practice D5743 which covers drum sampling.
SCOPE
1.1 This practice describes the procedure for sampling liquids with the composite liquid waste sampler, or “COLIWASA.” The COLIWASA is an appropriate device for obtaining a representative sample from stratified or unstratified liquids. Its most common use is for sampling containerized liquids, such as tanks, barrels, and drums. It may also be used for pools and other open bodies of stagnant liquid.  
Note 1: A limitation of the COLIWASA is that the stopper mechanism may not allow collection of approximately the bottom 2.54 cm (1 in.) of material, depending on construction of the stopper.  
1.2 The COLIWASA should not be used to sample flowing or moving liquids.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 A high percentage of insoluble, suspended solid material can create pumping, filtering, or grinding difficulties in the off-loading of bulk shipments of OLHW and can contribute to excessive wear on processing equipment. High solids can also decrease the quality and consistency of commingled solutions by decreasing the effectiveness of agitation in storage tanks. These issues are of concern to the recycling industries (solvents, paints, and other materials handled in significant quantities) in addition to those activities that propose to use the waste as a fuel.
SCOPE
1.1 This test method covers the determination of the approximate amount of insoluble, suspended solid material in organic liquid hazardous waste (OLHW).  
1.2 This test method is intended to be used in approximating the amount of insoluble, suspended solids in determining the material-handling characteristics and fuel quality of OLHW. It is not intended to replace more sophisticated procedures for the determination of total solids.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This is a performance-based method, and modifications are allowed to improve performance.  
5.1.1 Due to the rapid development of newer instrumentation and column chemistries, changes to the analysis described in this standard are allowed as long as better or equivalent performance data result. Any modifications shall be documented and performance data generated. The user of the data generated by this standard shall be made aware of these changes and given the performance data demonstrating better or equivalent performance.  
5.2 Organophosphate pesticides affect the nervous system by disrupting the enzyme that regulates acetylcholine, a neurotransmitter. They were developed during the early 19th century, but their effects on insects, which were similar to their effects on humans, were discovered in 1932. Some are poisonous and were used as chemical weapon agents. Organophosphate pesticides are usually not persistent in the environment.7,8  
5.3 This test method is for the analysis of selected organophosphorous based pesticide degradation products.  
5.4 This method has been investigated for use with various soils.
SCOPE
1.1 This procedure covers the determination of Diisopropyl Methylphosphonate (DIMP), Ethyl Methylphosphonic Acid (EMPA), Isopropyl Methylphosphonic Acid (IMPA), Methylphosphonic Acid (MPA), and Pinacolyl Methylphosphonic Acid (PMPA), referred to collectively as organophosphonates (OPs) in this test method, in soil. This method is based upon solvent extraction of a soil by pressurized fluid extraction (PFE). The extract is filtered and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). OPs are qualitatively and quantitatively determined by this method.  
1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 The method detection limit2 (MDL), electrospray ionization (ESI) mode, and reporting range3 for the OPs are listed in Table 1.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    15 pages
    English language
  • Standard
    15 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is applicable to sampling soils and similar fine-grained cohesive materials. This practice is to be used by personnel who are to acquire the samples.  
5.2 This practice should be used in conjunction with Guide D4687, which covers sampling plans, safety, quality assurance, preservation, decontamination, labeling, and chain-of-custody procedures; Practice D5088, which covers the decontamination of field equipment used at waste sites; and Practice D5283, which covers project specifications and practices for environmental field operations.
SCOPE
1.1 This practice covers sampling using a trier. A trier resembles an elongated scoop as shown in Fig. 1. The trier is used to collect samples of granular or powdered materials that are moist or sticky and have a particle diameter less than one half the diameter of the trier.
FIG. 1 Triers (Typical)  
1.2 The trier can be used as a vertical coring device only when it is certain that a relatively complete and cylindrical sample can be extracted.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    2 pages
    English language
  • Standard
    2 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice can be used in sampling drums, tanks, and similar containers and in sampling monitoring and waste wells including small-diameter (2.5 cm (1 in.)) wells. The pump can collect samples from multiple depths. The samples can be high-viscosity fluids, aggressive and corrosive fluids, high-purity solutions, and abrasive fluids. The pump can be used to mix samples (see Guide D6063).  
5.2 Peristaltic pumps use a vacuum to transport the samples. This vacuum may cause some degassing and loss of volatile organic compounds (VOCs) from the sample. When precise quantitative data for VOCs and dissolved gases are not required, peristaltic pumps may be used.  
5.3 The pump is self-priming, runs dry without damage, and is completely isolated from the pumped fluid. A sample can be taken on the intake or discharge side of the pump.  
5.4 Some additional advantages of the peristaltic pump are: decontamination of the pump motor is not necessary and the tubing in the pump is disposable and easy to replace. The pumps can be easily started and stopped and can pump fluids at a wide range of pressures and flow rates.  
5.5 The place, quality and quantity, frequency, and time of sampling are dependent upon the decisions that are to be made (see Practice D6250), sampling design (see Guide D6311), the sample, the heterogeneity of the samples (see Guide D5956), how representative the sample is (see Guide D6044), and the parameters to be tested as determined by the data quality objectives (DQOs) (see Practice D5792).
SCOPE
1.1 This practice covers the use of a peristaltic pump for sampling liquids from multiple depths. It is applicable for a wide range of fluids including: high-viscosity fluids, aggressive and corrosive fluids, high-purity solutions, and abrasive fluids. It is especially useful for sampling liquids that require complete isolation from the pump.  
1.2 This practice includes the determination of sample depth, pump setup, and collecting a sample to be analyzed.  
1.3 This practice is not intended to give detailed instructions for running a peristaltic pump or to recommend which peristaltic pump to purchase. It instructs the field personnel how to connect the pump and collect a sample.  
1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 “Stand-alone” laboratories rarely generate or handle large volumes of hazardous substances. However, the safe handling and disposal of these substances is still a matter of concern. Since the promulgation of the Resource Conservation and Recovery Act (RCRA) of 1976, more attention has been given to the proper handling and disposal of such materials. States may adopt more stringent requirements than required under RCRA. To keep track of this, EPA classifies state regulatory language as: (1) authorized, (2) procedural/enforcement, (3) broader in scope, and (4) unauthorized, and it publishes notices concerning the first three in the Federal Register.  
4.2 Laboratory management should designate an individual who will be responsible for waste disposal and must review the RCRA guidelines, in particular:
40 CFR 261.3—definition of a hazardous waste,
40 CFR 261.33—specific substances listed as hazardous,
40 CFR 262—generator requirements and exclusions, and proper shipping and manifesting procedures.  
4.3 Because many laboratory employees could be involved in the proper treatment and disposal of laboratory chemicals and samples, it is recommended that a safety and training program be designed and presented to all regarding procedures to follow in the treatment and disposal of designated laboratory wastes. This recommendation is required in the United States by the EPA (40 CFR 265.16). For those who pack and ship, Hazardous Materials Shipper training is also required by DOT (49 CFR 172.203).5  
4.4 If practical and economically feasible, it is recommended that all laboratory waste be either recovered, re-used, or disposed of in-house. However, should this not be the case, other alternatives are presented. This guide is intended only as a suggested organized method for classification, segregation, and disposal of chemical laboratory waste. A university can set up its own chemical distributor to take orders from departments, order in economical quantities, sell ...
SCOPE
1.1 This guide is intended to provide the chemical laboratory manager, chemical laboratory safety officer, and other relevant staff with guidelines for the disposal of small quantities of laboratory wastes safely and in an environmentally sound manner. This guide is applicable to laboratories that generate small quantities of chemical or toxic wastes. Generally, such tasks include, but are not limited to: analytical chemistry, process control, and research or life science laboratories. It would be impossible to address the disposal of all waste from all types of laboratories. This guide is intended to address the more common laboratory waste streams.  
1.2 This guide is primarily intended to support compliance with environmental laws in the United States of America; however, the information contained herein can be useful to laboratories in other geopolitical jurisdictions. Some of these laws provide for states to take over regulation of air quality or natural water quality with the approval of the Environmental Protection Agency (EPA). Other matters, such as laboratory waste tracking, disposal as household garbage, and use of sewers, are handled at the state, local, or provider level throughout the country. Examples of providers are air scrubber services, municipal sewer systems, municipal and private garbage services, and treatment, storage, or disposal facilities (TSD). Unfortunately, it is not possible for any one source to provide all the information necessary for laboratories to comply with all regulations. To ensure compliance, the laboratory manager must communicate with regulators at all four levels.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This ...

  • Guide
    8 pages
    English language
  • Guide
    8 pages
    English language

SIGNIFICANCE AND USE
4.1 This guide allows the decision maker to determine which remedial treatment processes are and are not applicable to remediate an area of soil, surface water, or ground water that contains contaminants of concern.  
4.2 This guide provides the data to make cost comparisons of the remedial treatment processes.  
4.3 Analysis of treatment process design data can often be performed at the site with field instruments and test kits.  
4.4 Tables 1 and 2 are a guide to selecting and obtaining physical and chemical treatment process design data. Data marked with an “X” is needed to evaluate alternatives and select a remedial treatment process. Once the remedial process is selected, the additional data that are needed to design the selected remedial treatment process are marked with an “O.” It may be advisable to also collect the data marked with an “O” during the initial sampling event to minimize sampling trips to the site.  
4.5 Tables 3 and 4 list laboratory and field methods for analyzing this data. More than one analytical method may be listed. The most suitable method must be chosen for each application. (A) This table was developed jointly by the U.S. Army Corps of Engineers, Hazardous, Toxic, and Radioactive Waste Center of Expertise and the U.S. Environmental Protection Agency Technical Support Project-Engineering Forum. Additional information and methods can be found in 40 CFR 136, EPA SW-846, and Standard Methods for Evaluation of Water and Wastewater, most current edition.(B) Estimated sensitivity and detection ranges are method/kit specific. Detection ranges are estimates. Verify these methods are suitable for the samples at this site. Consult the method or manufacturer's catalogs for details.(C) Spectrometers and meters are instruments that can be used to analyze for many parameters. Kits cost much less, but usually analyze for only one parameter. There are many manufacturers of field test equipment. Verify that the field methods are applicable to the m...
SCOPE
1.1 This guide lists the physical and chemical treatment processes design data needed to evaluate, select, and design treatment processes for remediation of contaminated sites. This data is listed in Tables 1 and 2. Much of these data can be obtained and analyzed at the site with instruments and test kits.    
1.2 It is recommended that this guide be used in conducting environmental site assessments and Remedial Investigations/Feasibility Studies (RI/FS) and selections of remedy in U.S. Code of Federal Regulations 40 CFR 300.430.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    10 pages
    English language

SIGNIFICANCE AND USE
5.1 These test methods are intended for use by those in the waste management industries to aid in identifying the flammability potential or waste materials. In addition to the test methods described here, flash points specific to liquid waste can be determined according to Test Method D8174 or D8175.
SCOPE
1.1 These test methods are used to indicate the fire-producing or fire-sustaining potential of wastes. The following test methods can be applied to waste liquids, sludges, or solids:    
Sections  
Test Method A—Test Specimen Exposed to Heat and Flame  
8 – 10  
Test Method B—Test Specimen Exposed to Spark Source  
11 and 12  
1.2 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.  
1.3 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.  
1.4 These test methods are designed and intended as preliminary tests to complement quantitative analytical techniques that are useful to determine flammability. These test methods offer the option and the ability to screen waste for hazardous flammability potential when the analytical techniques are not available or the total waste composition is unknown.  
1.5 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard information is given in Section 6, 9.3.1, and 10.4.3.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended to assist field personnel in obtaining samples from tanks for laboratory analysis. The cost associated with sampling and analysis, along with other reasons, make it essential that samples be taken correctly before submitting them for chemical analysis, physical testing, or both. Incorrect sampling can invalidate resulting data.  
5.2 This practice provides guidance in choosing the sampling technique and equipment suitable for specific situations. It is recommended that this guide be used as a supplement to a written field sampling plan.  
5.3 The procedures for sampling tanks using a COLIWASA, liquid profiler sampler, bacon bomb sampler, and peristaltic pump and tubing are delineated.
SCOPE
1.1 This practice covers information for field personnel to follow in order to collect samples from tanks.  
1.2 The purpose of this practice is to help field personnel in planning and obtaining samples from vertical and horizontal tanks, open-topped rectangular/square tanks, railroad and truck tankers, vacuum trucks, and tanks with multiple compartments using equipment and techniques that will assist in meeting the sampling objectives.  
1.3 The practice is applicable to hazardous materials, products, raw materials, by-product, or waste.  
1.4 Sampling from circulating pump discharge valves and tank transfer lines is not addressed in this practice.  
1.5 Units—The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended for use in the waste management industries to collect samples of unconsolidated waste from trucks. The sampling procedures described are general and should be used in conjunction with a site-specific work plan.  
5.2 The purpose of collecting waste samples directly from a truck (rather than the waste source) is often to verify (usually with screening analyses) that the waste contained in the truck is the same or similar material from a waste source that has been previously characterized and approved for treatment or disposal, or both. Additionally, it may be a safer or logistically easier to sample the waste from a truck over the waste source.
SCOPE
1.1 This practice covers several methods for collecting waste samples from trucks. These methods are adapted specifically for sampling unconsolidated solid wastes in bulk loads using several types of sampling equipment.  
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific precautionary statements.  
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This guide describes sample collection and handling procedures designed to minimize losses of VOCs. The principal mechanisms for the loss of VOCs from materials during collection, handling, and storage are volatilization and biodegradation. Susceptibility of various VOCs to these two loss mechanisms is both compound and matrix specific. In general, compounds with higher vapor pressures are more susceptible to volatilization than compounds with lower vapor pressures. Also, aerobically degradable compounds are generally more susceptible to biodegradation than anaerobically degradable compounds. In some cases, the formation of other compounds not originally present in the material can occur. Loss or gain of VOCs leads to analytical results that are unrepresentative of field conditions.  
5.2 Ancillary information concerning sample collection, handling, and storage for VOC analysis is provided in Appendix X1 – Appendix X3. These appendixes and cited references are recommended reading for those unfamiliar with the many challenges presented during the collection, handling, and storage of samples for VOC analysis.
SCOPE
1.1 This guide describes recommended procedures for the collection, handling, and preparation of solid waste, soil, and sediment samples for subsequent determination of volatile organic compounds (VOCs). This class of compounds includes low molecular weight aromatics, hydrocarbons, halogenated hydrocarbons, ketones, acetates, nitriles, acrylates, ethers, and sulfides with boiling points below 200° Celsius (C) that are insoluble or slightly soluble in water.  
1.2 Methods of sample collection, handling, storage, and preparation for analysis are described.  
1.3 This guide does not cover the details of sampling design, laboratory preparation of containers, and the analysis of the samples.  
1.4 It is recommended that this guide be used in conjunction with Guide D4687.  
1.5 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects. The word “standard” in the title of this document means only that the document has been approved through the ASTM consensus process.  
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    16 pages
    English language
  • Guide
    16 pages
    English language

SIGNIFICANCE AND USE
4.1 This test method is intended as a means for obtaining an extract of mining waste. The extract may be used to estimate the release of certain inorganic constituents of the waste under the laboratory conditions described in this test method. The user is advised to minimize the holding time between sampling and testing if the waste is suspected to contain reactive sulfide minerals.
Note 3: This method is not intended to be used as a kinetic test to simulate weathering of mining wastes. For kinetic testing of mining wastes, refer to Test Method D5744 to determine release rates for constituents of interest. For static testing of metal mining ore and mining or mineral processing waste materials, refer to Test Methods E1915.  
4.2 The pH of the extraction fluid used in this test method is to reflect the pH of acidic precipitation in the geographic region in which the waste being tested is to be disposed (see 1.2).  
4.3 An intent of this test method is for the final pH of the extract to reflect the interaction of the extractant with the buffering capacity of the waste.  
4.4 This test method is not intended to provide an extract that is representative of the actual leachate produced from a waste in the field or to produce extracts to be used as the sole basis of engineering design. If the conditions of this test method are not suitable for the test material, USEPA Method 1312 or Test Method E2242 may be used.  
4.5 This test method has not been demonstrated to simulate actual disposal site leaching conditions.  
4.6 This test method produces extracts that are amenable to the determination of both major and minor (trace) inorganic constituents. When minor constituents are being determined, it is especially important that precautions be taken in sample storage and handling to avoid possible contamination of the samples.  
4.7 This test method has been tested to determine its applicability to certain inorganic components in the waste. This test method has not been...
SCOPE
1.1 This test method covers a procedure for the shake leaching of mining waste containing at least 80 % dry solids (≤20 % moisture) in order to generate a solution to be used to determine the inorganic constituents leached under the specified testing conditions that conform to the synthetic precipitation leaching procedure (SPLP).  
1.2 This test method calls for the shaking of a known weight of mining waste with acidic extraction fluid of a specified composition, as well as the separation of the liquid phase for analysis. The pH of the extraction fluid is to reflect the pH of acidic precipitation in the geographic region in which the waste being tested is to be disposed.
Note 1: Possible sources of information concerning the pH of the precipitation in the geographic region of interest include state and federal environmental agencies, state universities, libraries, etc. pH values given in USEPA Method 1312, that are 4.2 east of the Mississippi River and 5.0 west of the Mississippi River and are based on acid precipitation maps, are examples of values that can be used. If the pH of the laboratory water is less than the desired pH for the site, do not use this test method; use Practice D3987 or Test Method E2242.
Note 2: The method may also be suitable for use in testing of mineral processing waste from metal mining process operations for jurisdictions that do not require the use of Test Method E2242.  
1.3 This test method is intended to describe the procedure for performing single batch extractions only. It does not describe all types of sampling, sample preservation, and analytical requirements that may be associated with its application.  
1.4 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user...

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
4.1 This practice is intended as a rapid means for obtaining an extract of solid waste. The extract may be used to estimate the release of constituents of the solid waste under the laboratory conditions described in this procedure.  
4.2 This practice is not intended to provide an extract that is representative of the actual leachate produced from a solid waste in the field or to produce extracts to be used as the sole basis of engineering design.  
4.3 This practice is not intended to simulate site-specific leaching conditions. It has not been demonstrated to simulate actual disposal site leaching conditions.  
4.4 The intent of this practice is that the final pH of the extract reflects the interaction of the extractant with the buffering capacity of the solid waste.  
4.5 The intent of this practice is that the water extraction simulates conditions where the solid waste is the dominant factor in determining the pH of the extract.  
4.6 The practice produces an extract that is amenable to the determination of both major and minor constituents. When minor constituents are being determined, it is especially important that precautions are taken in sample storage and handling to avoid possible contamination of the samples.  
4.7 The practice has not been tested for applicability to organic substances and volatile matter.
SCOPE
1.1 This practice covers a procedure for leaching of solid waste to obtain an aqueous solution to be used to determine the constituents leached under the specified testing conditions.  
1.2 This practice provides for the shaking of a known mass of waste with water of specified composition and the separation of the aqueous phase for analysis.  
1.3 The values stated in SI units are to be regarded as standard. Values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method has been developed by the U.S. EPA Region 5 Chicago Regional Laboratory (CRL).  
5.2 TTPC may be used in various industrial and commercial products for use as a biocide. Products containing TTPC have been approved for controlling algal, bacterial, and fungal slimes in industrial water systems.2 TTPC should not be persistent in water but may be deposited in sediments at concentrations of concern. Hence, there is a need for quick, easy, and robust method to determine TTPC concentration at trace levels in various soil matrices for understanding the sources and concentration levels in affected soils and sediments.  
5.3 This method has been used to determine TTPC in sand, a commercial top soil, and four ASTM reference soils (Table 4).
SCOPE
1.1 This procedure covers the determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in a soil matrix by extraction with acetone, filtration, dilution with water, and analysis by liquid chromatography/tandem mass spectrometry. TTPC is a biocide that strongly adsorbs to soils.2 The sample extracts are prepared in a solution of 75 % acetone and 25 % water because TTPC has an affinity for surfaces and particles. The reporting range for this method is from 250 to 10 000 ng/kg. This analyte is qualitatively and quantitatively determined by this method. This method adheres to multiple reaction monitoring (MRM) mass spectrometry.  
1.2 The method detection limit (Note 1) (MDL) and reporting range (Note 2) for the target analyte are listed in Table 1.  
Note 1: The MDL is determined following the Code of Federal Regulations, 40 CFR Part 136, Appendix B, as a guide utilizing solvent extraction of soil. Two-gram sample of Ottawa sand was utilized. A detailed process determining the MDL is explained in the reference and is beyond the scope of this standard to be explained here.
Note 2: Reporting range concentration is calculated from Table 2 concentrations assuming a 50-μL injection of the Level 1 calibration standard for TTPC, and the highest level calibration standard with a 20-mL final extract volume of a 2-g soil sample. Volume variations will change the reporting limit and ranges.  
1.2.1 The reporting limit in this test method is the minimum value below which data are documented as non-detects. Analyte detections between the method detection limit and the reporting limit are estimated concentrations and are not reported following this test method. The reporting limit is calculated from the concentration of the Level 1 calibration standard as shown in Table 2 for TTPC after taking into account a 2-g sample weight and a final extract volume of 20 mL in 75 % acetone/25 % water. The final extract volume is 20 mL because a 15-mL volume of acetone is added to each soil sample and only the liquid layer after extraction is filtered leaving the solid behind followed by the addition of 5 mL of water to the acetone extract.  
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    9 pages
    English language

SIGNIFICANCE AND USE
8.1 This practice is intended for use by those in the waste management industries to aid in determining the compatibility of hazardous wastes before they are commingled.
SCOPE
1.1 These practices cover assessment of the compatibility/reactivity of waste. The individual practices are as follows:    
Sections  
Practice A—Commingled Waste Compatibility  
8 – 12  
Practice B—Polymerization Potential (Reaction with  
Triethylamine)  
13 – 18  
Practice C—Water Compatibility  
19 – 25  
1.2 These practices are applicable to waste liquids, sludges, semi-solids, and solids.  
1.3 These practices are designed and intended as a preliminary or supplementary test to complement the more sophisticated quantitative analytical techniques that should be used to determine waste composition and compatibilities. This standard offers the user the option and the ability to screen wastes for potentially hazardous reactions when the more sophisticated techniques are not available and the total waste composition is unknown, and to screen compatibility when the composition is known. (Warning—Delayed or slow reactions of wastes may go unnoticed.)  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4.1 Exception—The values given in parentheses are for information only.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard and warning statements, see Sections 1.3, 6.1, 10, 11.2.3, 11.5.2, 16, and 23.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This test method developed for the analysis of TPs in soil and sediment samples is based upon an LC/MS/MS analysis. Any type of coupled liquid chromatography/mass spectrometry system may be used that meets the study objectives of the individual project. These may include, but are not limited to: trap, single quadrupoles, time-of-flight, high resolution, and others not mentioned here.  
5.2 The MDL and reporting range for TPs are listed in Table 1. This SOP has been tested on Ottawa sand, four ASTM soil types, biosolid sample, and one commercial soil. The P&A QC acceptance criteria are listed in Table 3. Tables 4-17 display the TC and surrogate recoveries in the various soil types. 40 CFR Part 136, Appendix B was used as a guide to determine the MDLs. The 40 CFR Part 136 MDL criteria were not met for NP2EO; this does not affect the method because the SOP only reports to the RL and is not a regulatory method. All site sample results are not reported below the RL using this method. RLCS concentrations may be reported below the RL because they are spiked at or near the RL. (A) Uncertainty calculation based upon 95 % confidence interval and a two-tailed Student t distribution.
Uncertainty = Student t Value [(standard deviation) / (number of LCS)1/2].            (A) P&A values are after subtraction of average of MB if ≥RL.   (A) P&A values are after subtraction of average of MB if ≥RL.  (A)    
5.3 The RL for a specific soil sample may differ from that listed depending on the nature of the interferences in the sample matrix. Variability in historical LCS spike recovery may be used to estimate uncertainty. The estimate of minimum laboratory contribution to measurement uncertainty of this test method for each analyte is listed in Table 3. These values are derived from P&A samples from the initial IDOC study for this test method. The uncertainty will be greater near the RL and much greater near the DL. Also, uncertainty estimated based on variability in LCS recov...
SCOPE
1.1 This test method covers analysis of nonylphenol (NP), nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), octylphenol (OP), and bisphenol A (BPA), referred to collectively as target phenols (TPs), in soil, sediments, and biosolids by extraction with acetone, filtration, dilution with water, and analysis by liquid chromatography/tandem mass spectrometry. The sample extracts are prepared in a solution of 75 % acetone and 25 % water because TPs have an affinity for surfaces and particles that is more pronounced at lower concentrations. The range of applicability of the test method is shown in Table 1. The method may be extended outside of these ranges depending on additional performance studies not undertaken here.  
1.2 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    14 pages
    English language

SIGNIFICANCE AND USE
4.1 This guide provides persons responsible for designing and implementing wastewater sampling programs with a summary of the types of automatic wastewater samplers, discusses the advantages and disadvantages of the different types of samplers, and addresses recommended procedures for their use. The field settings are primarily, but not limited to, open channel flows in enclosed (e.g., sewer) systems or open (e.g., streams or open ditches, and sampling pressure lines) systems.
SCOPE
1.1 This guide covers the selection and use of automatic wastewater samplers, including procedures for their use in obtaining representative samples. Automatic wastewater samplers are intended for the unattended collection of samples that are representative of the parameters of interest in the wastewater body. While this guide primarily addresses the sampling of wastewater, the same automatic samplers may be used to sample process streams and natural water bodies.  
1.2 The guide does not address general guidelines for planning waste sampling activities (see Guide D4687), development of data quality objectives (see Practice D5792), the design of monitoring systems and determination of the number of samples to collect (see Guide D6311), operational details of any specific type of sampler, in-situ measurement of parameters of interest, data assessment and statistical interpretation of resultant data (see Guide D6233), or sampling and field quality assurance (see Guide D5612). It also does not address sampling groundwater.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3.1 Exception—The inch-pound units given in parentheses are for information only.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice will identify waste materials that are potentially unstable when they come in contact with other materials at a waste treatment or disposal site.  
5.2 This practice will serve to determine the miscibility of waste materials with various media, including other wastes.  
5.3 This practice may not be applicable to all wastes. The appropriateness of these tests depends upon the proposed management of the waste.  
5.4 Since the initiation of some chemical reactions are slow to take place, the user may wish to establish reagent-to-waste contact times prior to observing the mixes for any reactions.
SCOPE
1.1 This practice is designed to determine whether a waste material reacts when it is mixed with air, water, strong acid, strong base, an oil/solvent mixture, other waste mixtures, or solid media such as a geological formation or solidification agents.  
1.2 The miscibility of the waste material with the above media can also be defined.  
Note 1: The following ASTM standards provide supplemental information: Test Methods D4978, D4980, D4982, D5049, and D5057 and Practices D4979, D4981, and D5058.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

Frequently Asked Questions

D34.01 is a Technical Committee within ASTM International. It is named "Monitoring and Characterization". This committee has published 388 standards.

D34.01 develops ASTM standards in the area of Information technology. Currently, there are 388 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...