Abstract

This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline, small engine petrol and ethanol (E85) automotive fuel. Additionally, the benzene and toluene content, oxygenated compounds and the total oxygen content can be determined.
Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates, this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as naphthas and reformates.

Status
Not Published
Public Enquiry End Date
04-Jan-2027
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
02-Nov-2026
Due Date
22-Mar-2027

Buy Documents

Draft

oSIST prEN ISO 22854:2026

English language (33 pages)
Preview
Preview
e-Library read for
×1 day

Relations

Effective Date
01-Dec-2026

Buy Documents

Draft

oSIST prEN ISO 22854:2026

English language (33 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

ABS Group Brazil

ABS Group certification services in Brazil.

CGCRE Brazil Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN ISO 22854:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Liquid petroleum products - Determination of hydrocarbon types and oxygenates in automotive-motor gasoline - Multidimensional gas chromatography method (ISO/DIS 22854:2026)". This standard covers: This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline, small engine petrol and ethanol (E85) automotive fuel. Additionally, the benzene and toluene content, oxygenated compounds and the total oxygen content can be determined. Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates, this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as naphthas and reformates.

This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline, small engine petrol and ethanol (E85) automotive fuel. Additionally, the benzene and toluene content, oxygenated compounds and the total oxygen content can be determined. Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates, this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as naphthas and reformates.

oSIST prEN ISO 22854:2026 is classified under the following ICS (International Classification for Standards) categories: 71.040.50 - Physicochemical methods of analysis; 75.080 - Petroleum products in general; 75.160.20 - Liquid fuels. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN ISO 22854:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 22854:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN ISO 22854:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2026
Tekoči naftni proizvodi - Določanje vrste ogljikovodikov in oksigenatov v
motornem bencinu in bencinu na osnovi etanola (E85) - Metoda
multidimenzionalne plinske kromatografije (ISO/DIS 22854:2026)
Liquid petroleum products - Determination of hydrocarbon types and oxygenates in
automotive-motor gasoline - Multidimensional gas chromatography method (ISO/DIS
22854:2026)
Flüssige Mineralölerzeugnisse - Bestimmung von Kohlenwasserstoffgruppen und
sauerstoffhaltigen Verbindungen in Ottokraftstoffen - Multidimensionales
gaschromatographisches Verfahren (ISO/DIS 22854:2026)
Produits pétroliers liquides - Détermination des groupes d'hydrocarbures et de la teneur
en composés oxygénés de l'essence pour moteurs automobiles et du carburant éthanol
pour automobiles (E85) - Méthode par chromatographie multidimensionnelle en phase
gazeuse (ISO/DIS 22854:2026)
Ta slovenski standard je istoveten z: prEN ISO 22854
ICS:
71.040.50 Fizikalnokemijske analitske Physicochemical methods of
metode analysis
75.160.20 Tekoča goriva Liquid fuels
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
International
Standard
ISO/DIS 22854
ISO/TC 28
Liquid petroleum products —
Secretariat: NEN
Determination of hydrocarbon
Voting begins on:
types and oxygenates in automotive-
2026-10-22
motor gasoline — Multidimensional
Voting terminates on:
gas chromatography method
2027-01-14
ICS: 75.080
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENTS AND APPROVAL. IT
IS THEREFORE SUBJECT TO CHANGE
AND MAY NOT BE REFERRED TO AS AN
INTERNATIONAL STANDARD UNTIL
PUBLISHED AS SUCH.
This document has not been edited by the ISO Central Secretariat.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
ISO/CEN PARALLEL PROCESSING
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
NATIONAL REGULATIONS.
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION.
Reference number
ISO/DIS 22854:2026(en)
ISO/DIS 22854:2026(en)
© ISO 2026
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
ISO/DIS 22854:2026(en)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions, symbols and abbreviated terms . 1
3.1 Terms and definitions .1
3.2 Symbols and abbreviated terms .2
4 Principle . 3
5 Reagents and materials . 4
6 Apparatus . 5
7 Sampling . 6
8 Procedure . 6
8.1 Conditioning.6
8.2 Sample preparation .6
8.2.1 Procedure B only — Sample dilution .6
8.2.2 All procedures — Sample cooling .7
8.3 Test sample injection volume .7
8.4 Tuning of the apparatus (Procedure C) .7
8.5 V erification of the apparatus and test conditions .7
8.6 Validation .7
8.7 Preparation of the test sample .7
8.8 Preparation of the apparatus and test conditions .8
9 Calculation . 8
9.1 General .8
9.2 Calculation as a mass fraction in per cent .8
9.3 Calculation as a volume fraction in per cent .9
9.4 Calculation of total oxygen content in mass fraction in per cent .11
9.5 Data report according to automotive motor gasoline specifications .11
10 Expression of results .11
10.1 Procedure A and C .11
10.2 Procedure B . 12
11 Precision .12
11.1 General . 12
11.2 Repeatability, r. 12
11.3 Reproducibility, R . 12
12 Test report . 14
Annex A (informative) Instrument specifications .15
Annex B (informative) Examples of typical chromatograms .18
Bibliography .28

iii
ISO/DIS 22854:2026(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 28, Petroleum and related products, fuels and
lubricants from natural or synthetic sources, in collaboration with the European Committee for Standardization
(CEN) Technical Committee CEN/TC 19, Gaseous and liquid fuels, lubricants and related products of petroleum,
synthetic and biological origin, in accordance with the Agreement on technical cooperation between ISO and
CEN (Vienna Agreement).
This sixth edition cancels and replaces the fifth edition (ISO 22854:2021), which has been technically
revised.
The main changes are as follows:
— the Scope (Clause 1) and precision (Clause 11) have been expanded, respectively revised, in terms of
contents of ethanol, ETBE, MTBE, and total oxygenates and , as well as the use for determination of total
thers and napthenes have been introduced;
— following the introduction of procedure C in the previous publication, the title has been generalized;
— following the outcome of the latest interlaboratory study, guidance regarding measuring so-called E20-
type fuels ( available beforehand) has been highlighted more.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

iv
ISO/DIS 22854:2026(en)
Introduction
Originally, this document was used for the determination of saturated, olefinic, aromatic and oxygenated
[1]
hydrocarbons in automotive motor gasoline according to European fuel specifications, such as EN 228 or
[2]
CEN/TS 18227:2025
An interlaboratory study has shown that the method described in this document can be used for gasolines
with a higher concentration of oxygenated compounds, including methanol. The interlaboratory study also
provided data to calculate precision for toluene in gasoline. A similar study in 2026 confirmed the use for
gasolines with higher alcohol and ether oxygenate contents, extending the scope to so-called E20 petrol
[2]
CEN/TS 18227:2025 .
A study in 2019-2020 focused on higher ether contents. Annex B includes example chromatograms of
gasolines with a variety of oxygenates, which can be used to correctly identify these oxygenates.
Another interlaboratory study has shown that the method is applicable for gasolines with a very low content
[3]
of aromatic compounds, such as those described in EN 17867 The study delivered optimalization of a
validation step (Procedure C).
This document lays down three procedures: A, B and C. The application ranges of each are given in Table 1.
Procedure A is the normal procedure for motor gasoline, whereas Procedure B describes the procedure for
the analysis of oxygenated groups (ethanol, methanol, ethers, C3 – C5 alcohols) in ethanol (E85) automotive
fuel. Procedure C describes the analysis of small engine petrol fuel containing low contents of aromatics and
olefins.
[4]
The test method described in this document is harmonized with ASTM D6839 except for Procedure C
which focuses on European products only.

v
DRAFT International Standard ISO/DIS 22854:2026(en)
Liquid petroleum products — Determination of hydrocarbon
types and oxygenates in automotive-motor gasoline —
Multidimensional gas chromatography method
1 Scope
This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic
and aromatic hydrocarbons in automotive motor gasoline, small engine petrol and ethanol (E85) automotive
fuel. Additionally, the benzene and toluene content, oxygenated compounds, the total oxygen and total ether
content can be determined (see Table 1).
Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates,
this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as
naphthas and reformates.
2 Normative references
There are no normative references in this document.
3 Terms, definitions, symbols and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1.1
hydrocarbon group, noun
HG, noun
family of hydrocarbons
EXAMPLE Saturated hydrocarbons (3.1.2) or olefinic hydrocarbons (3.1.3).
3.1.2
saturate, noun
saturated hydrocarbon, noun
type of hydrocarbon that contains no double bonds with a carbon number of 3 to 12
EXAMPLE n-paraffins, iso-paraffins, cyclo-alkanes and poly-cyclic alkanes.
3.1.3
olefin, noun
olefinic hydrocarbon, noun
type of hydrocarbon that contains double or triple bonds with a carbon number of 3 to 10
EXAMPLE n-Olefins, iso-olefins and cyclic olefins.

ISO/DIS 22854:2026(en)
3.1.4
aromatic, noun
aromatic hydrocarbon, noun
type of cyclic hydrocarbon with alternating double and single bonds between carbon atoms forming the
rings
EXAMPLE Benzene, toluene and higher homologous series with a carbon number of 6 to 10 and polycyclic
aromatic hydrocarbons, with a carbon number of up to 12.
3.1.5
oxygenate, noun
oxygenated compound, noun
type of hydrocarbon that contains one or more oxygen atoms, the addition of which is allowed according to
fuel specifications
EXAMPLE Alcohols and ethers.
3.2 Symbols and abbreviated terms
For the purposes of this document, the following symbols and abbreviations apply.
A total, corrected signal area for the hydrocarbon group
HG
BOB before oxygenate blending
DIPE di-isopropyl ether
E85 ethanol automotive fuel
ETBE ethyl-tert-butyl ether
FID flame ionization detector
F theoretical relative response factor of a particular carbon number for a hydrocarbon type
RR,HG
group
φ volume fraction in per cent for a hydrocarbon group
HG
GC gas chromatography
HG hydrocarbon group
ID Internal diameter
M molar mass of carbon
C
M molar mass of hydrogen
H
M molar mass of the oxygenated compound
i
M molar mass of oxygen
O
MTBE methyl-tert-butyl ether
n number of carbon atoms in the group
C
n number of hydrogen atoms in the group
H
n number of oxygen atoms in the molecule
O
PTFE polytetrafluoroethylene
ISO/DIS 22854:2026(en)
QC quality control
ρ density of the hydrocarbon group
HG
r repeatability
R reproducibility
TAEE tertiary amyl-ethyl ether
TAME tertiary amyl-methyl ether
w mass fraction in per cent for a hydrocarbon group
HG
w mass percentage of the compound in the mixture
i
X the mean of the two results being compared
4 Principle
4.1 The application ranges for each procedure are given in Table 1. All procedures specified use the same
separation technique and analysis procedure.
a
Table 1 — Application ranges for each procedure
Component or group Procedure A Procedure B Procedure C
Saturates, % (volume fraction) 26,9 – 79,3
Total aromatics, % (volume fraction) 19,3 – 46,3 0,4 – 2,7
Total olefins, % (volume fraction) 0,4 – 26,9 0,1 – 2,4
Benzene, % (volume fraction) 0,38 – 1,98 0,1 – 0,5 0,04 – 0,11
Toluene, % (volume fraction) 5,85 – 31,65
n-Hexane, % (volume fraction) 0,1 - 2,1
Total napthenes (C6-C8), % (volume
b
4,89 - 8,85 0,2 - 3,8
fraction)
c
Oxygenates , % (volume fraction) 0,61 – 33,24 0,08 – 0,86
Total oxygen content, % (mass fraction) 0,50 – 12,32 0,02 – 0,16
Methanol, % (volume fraction) 1,05 – 16,96
Ethanol, % (volume fraction) 0,34 – 32,00 > 50,0 and < 85,0 0,06 - 0,39
C3 − C5 alcohols, % (volume fraction) > 1,4 and < 6,0
Ethers, % (volume fraction) 1,22 – 26,19 > 0,5 and < 11,0
MTBE, % (volume fraction) 0,41 – 24,89 0,01 – 0,70
ETBE, % (volume fraction) 0,11 – 24,89 0,09 – 0,73
TAME, % (volume fraction) 1,0 – 24,84
TAEE, % (volume fraction) 1,0 – 15,6
a
Empty cells indicate that the application range has not been determined.
b [5]
Precision for this group under Procedure A could not be determined (see )
c
Oxygenated compounds (as individual component or as total oxygenates).
4.2 The gasoline sample being analysed is separated into hydrocarbon groups by means of GC analysis
using special column-coupling and column-switching procedures.
The sample is injected into the GC system and, after vaporization, is separated into the different groups.
Detection is always done by a flame ionization detector (FID).

ISO/DIS 22854:2026(en)
4.3 The mass concentration of each detected compound or hydrocarbon group is determined by the
application of relative response factors (see 9.2) to the area of the detected peaks, followed by normalization
to 100 %. For automotive motor gasoline samples containing oxygenates that cannot be determined by this
test method, the hydrocarbon results are normalized to 100 % minus the value of oxygenates as determined
by another method. The liquid volume concentration of each detected compound or hydrocarbon group is
determined by the application of density values (see 9.3) to the calculated mass concentration of the detected
peaks followed by normalization to 100 %.
WARNING — To ensure the method is executed correctly, it is essential to carefully verify that all
compounds are correctly identified. This is especially true for the identification of oxygenated
compounds because of their wide range of response factors. To ensure correct identification, it is
therefore highly recommended to verify possibly unknown oxygenates using a reference mixture
that contains these pure compounds.
4.4 After this analysis, the automotive motor gasoline is separated into hydrocarbon groups and then by
carbon number. Using the corresponding relative response factors, the mass distributions of the groups in
the automotive motor gasoline sample can be calculated.
4.5 Procedure A assesses the total oxygenates content and individual oxygenates. The ranges given are
considered to apply to individual oxygenated compounds or the total group of (unidentified, not further
precised) oxygenates. For Procedure A, applicability of this document has been verified for the determination
of n-propanol, acetone, and di-isopropyl ether (DIPE). However, no precision data have been determined for
these compounds.
4.6 Procedure B involves the analysis of oxygenated groups (ethanol, methanol, ethers, C3 – C5 alcohols) in
ethanol (E85) automotive fuel containing ethanol with a mass fraction of between 50 % and 85 %. Procedure
B differs from Procedure A, in that the sample is diluted with an oxygenate-free component to lower the
ethanol content to a value below 20 % before the analysis by GC. The diluting solvent is not considered in
the integration. This makes it possible to report the results of the undiluted sample after normalization
to 100 %.
The sample can be fully analysed including hydrocarbons. Precision data for the diluted sample are only
available for the oxygenated groups.
An overlap between C9 and C10 aromatics can occur. However, the total is accurate. Isopropyl benzene is
resolved from the C8 aromatics and is included with the other C9 aromatics.
4.7 Procedure C is applicable to the analysis of small engine petrol fuel containing low contents of
aromatics and olefins. Procedure C differs from Procedure A, in that it requires an additional tuning step to
ensure that the individual oxygenates, aromatics and olefins are correctly identified by optimizing the pre-
column temperatures and valve settings.
5 Reagents and materials
5.1 Hydrogen, 99,995 % pure.
WARNING — Hydrogen is explosive when mixed with air at a concentration between 4 % and 75 %
volume fraction. Refer to the equipment manufacturers’ manuals concerning leaks in the system.
Installation of suitable moisture filters is recommended for hydrogen lines.
5.2 Helium or nitrogen, 99,995 % pure.
The system’s operating parameters such as column and trap temperatures, carrier gas flows and valve
switching times depend on the type of carrier gas used. The use of nitrogen as carrier gas is not possible on
all configurations. Contact the equipment manufacturer for specific information or instructions on the use
of nitrogen.
ISO/DIS 22854:2026(en)
Installation of suitable moisture filters is recommended for helium and nitrogen lines.
5.3 Compressed air.
5.4 Vials, airtight and inert, e.g. with rubber-membrane caps covered with self-sealing
polytetrafluoroethylene (PTFE).
5.5 Reference solutions, finished automotive motor gasoline(s) used as reference and which contain
components and concentration levels comparable to those of the test sample.
The composition of the reference solution should have been determined in an interlaboratory or proficiency
test, or by other methods.
For Procedure C, make sure that the contents of aromatics, benzene and olefins in the solution are sufficiently
low and comparable to those of the test sample.
WARNING — The reference solutions are flammable and harmful if inhaled.
5.6 Diluting solvent, used in Procedure B, shall not interfere with any other component in gasoline being
analysed. Dodecane (C H ) or tridecane (C H ) are recommended solvents.
12 26 13 28
5.7 Tuning solution, used in Procedure C, containing a mixture of oxygenates (ethanol, MTBE and ETBE)
and benzene, at levels at the end or just above those of this methods range (see Table 1) and complemented
with a base solution containing various aromatics and olefins.
As a base solution, a regular oxygen-free (BOB) refinery stream is recommended. An example of a tuning
solution is given in Table 2.
Table 2 — Example of a tuning solution composition
Component or group Content
volume fraction
%
Ethanol 0,87
MTBE 0,87
ETBE 0,87
Benzene 1,00
6 Apparatus
6.1 Gas chromatograph, computer-controlled, multidimensional GC equipment, injector, FID, suitable
columns, traps and hydrogenation catalysts, of which an example is given in Annex A.
6.2 Switching valves, suitable switching valves that are used for the transfer of compounds from one
column to the other in the gas chromatograph.
They shall have a chemically inactive surface and a small dead volume.
6.3 Traps, suitable short columns (see Annex A for an example) used for retaining certain selected
chemical groups of the automotive motor gasoline using temperature control.
The absorption of the trapped compounds shall be reversible.
EXAMPLE A typical sequence is as follows:
— The alcohols and higher-boiling aromatics are absorbed in a trap (sulfate column I). The remaining aromatics are
separated from the other components by means of a polar column (e.g. OV 275).

ISO/DIS 22854:2026(en)
— The ethers are separated from the remaining fraction by means of another trap (sulfate column II).
— The olefins are separated from the saturates by the olefin trap (e.g. silver salt) in two steps. This is important
due to the limited capacity of such traps to retain high amounts of butene or total olefins. If the trap capacity is
sufficient for the olefin concentration, the separation can be performed in one step.
— The remaining saturated hydrocarbons are separated into paraffins and cyclo alkanes (naphthenes) according to
their carbon number using a 13X molecular sieve column.
— The ethers are then eluted from the trap (sulfate column II) and separated and detected according to the boiling
point.
— The olefins are desorbed from the olefin trap and hydrogenated in the Pt-column. They are separated and detected
as the corresponding saturated compounds using a 13X molecular sieve.
— The alcohols and higher-boiling aromatics are eluted from the polar column and the trap (sulfate column I),
separated using a non-polar column (e.g. OV 101 methyl silicone) and detected according to the boiling point.
Examples of typical chromatograms with this order of elution of the hydrocarbon fractions are shown in
Figure B.1 to Figure B.4. Specifically, for Procedure B, a typical chromatogram is shown in Figure B.5. For
Procedure C, exemplary chromatograms of the tuning are shown in Figure B.6.
WARNING — Sulfur-containing compounds are irreversibly adsorbed in the olefins trap and can
reduce its capacity to retain olefins. Sulfur can also adsorb in the alcohol and ether-alcohol-aromatic
traps. Although the effect of low amounts of sulfur components on the various traps or columns is
very small, it is important to exercise care when handling automotive motor gasoline samples with
high levels of sulfur.
7 Sampling
Samples shall be taken in accordance with ISO 3170 for manual sampling or in accordance with ISO 3171 for
automatic pipeline sampling.
NOTE National fuel specification standards or legal requirements for the sampling of automotive motor gasoline
can apply.
8 Procedure
8.1 Conditioning
Condition the apparatus according to the manufacturer’s instructions after shutdowns.
When gas connections have been disconnected or the flow turned off, condition the system by permitting
carrier gas to flow through the system for at least 30 min while the system is at ambient temperature.
8.2 Sample preparation
8.2.1 Procedure B only — Sample dilution
The procedure described in this subclause is used to analyse gasoline samples containing higher amounts of
ethanol such as ethanol (E85) automotive fuel with ethanol content between a volume fraction of 50 % and
a volume fraction of 85 %.
As the sulfate column I trap (see Table A.1) cannot trap high amounts of ethanol, the sample shall be diluted.
The selected diluting solvent (see 5.6) shall not interfere with the analysis. The level of dilution should be
chosen in such a way that the final amount of ethanol does not exceed a volume fraction of 20 %. If the
ethanol content is unknown, it is recommended to use a dilution ratio of 4:1 when analysing the sample.

ISO/DIS 22854:2026(en)
8.2.2 All procedures — Sample cooling
Cool the test sample to prevent loss by evaporation. Transfer a sufficient portion of the test sample to a vial
(5.4) and immediately tightly close and seal it using the self-sealing PTFE cap (see 5.4). It is recommended to
cool the test sample to a temperature between 0 °C and 5 °C.
8.3 Test sample injection volume
Size the injection volume of the test sample in such a way that the capacity of the columns is not exceeded
and the linearity of the detector is valid.
NOTE An injection volume of 0,1 µl has proven to be satisfactory.
8.4 Tuning of the apparatus (Procedure C)
This tuning step is required for type of products using small engine petrol fuel, which are low in olefin
content and are substantially free of aromatic compounds, especially benzene. This step requires optimizing
the pre-column temperatures and valve settings.
Run the tuning solution (5.7) and check for correct instrument parameters, cutting times and grouping times.
Verify whether all individual components have been identified correctly, like the examples in Figure B.6.
Some deviation from the target values is allowed but special attention should be paid to the MTBE and
ETBE values in conjunction with the benzene value. MTBE and ETBE tend to coelute with benzene when
the precolumn temperature is too high. Lower the precolumn temperature by steps of 10 °C and rerun the
tuning solution until each component can be correctly identified.
8.5 Verification of the apparatus and test conditions
For all procedures, run the reference solution (see 5.5) and check for correct instrument parameters, cutting
times and grouping times, by verifying whether all individual components are identified correctly. If they are
not correct, adjust the apparatus to the manufacturer’s recommendations and rerun the reference solution
until the results are correct.
WARNING — Attention should be paid to components, such as benzene, olefins and oxygenates,
that are near the boundaries of separation on the group-selective columns. Care should be taken to
accurately identify the oxygenated compounds, especially with medium-blend type of products. It is
recommended to verify the identity of possible oxygenates using a reference material that contains
the pure component of interest. Annex B shows several chromatograms specifically for oxygenate
compounds, providing evidence of their elution times and possible interferences.
[6]
NOTE A study, see CEN/TR 15745 has shown that iso-propanol often eludes in two peaks. Notwithstanding the
notice of importance in 4.3, this elution can happen. In this case, it is important to identify both peaks properly. When
the peaks are correctly identified, the reproducibility in 11.3 applies.
8.6 Validation
Reprocess the validation reference solution (see 5.5) and compare the obtained results with the consensus
values. The absolute deviation from the consensus values shall not be greater than the reproducibility for
the parameters given in Clause 11.
It is strongly recommended to run the validation reference solution weekly to check the proper functioning
of the equipment.
The validation reference solution(s) should contain the components in amounts similar to those found in the
test samples. Validation of the apparatus should be performed prior to the analysis of any new oxygenates.
8.7 Preparation of the test sample
Prepare the test sample as specified in 8.2.

ISO/DIS 22854:2026(en)
8.8 Preparation of the apparatus and test conditions
Set up the apparatus in accordance with 8.1 and check it in accordance with 8.5.
For Procedure C, check the areas in between the fractions on “unexpected peaks”. These can be components
eluting in the wrong fraction and adjustment of the temperature(s) can be required. Also check peak shapes,
such as double peaks or skewed peaks, which can indicate an incorrect elution order. Adjust the valve times
using the tuning and reference solutions.
9 Calculation
9.1 General
For Procedure A and C, 9.2 to 9.5 shall be followed.
For Procedure B, in the final calculations, the peak area of the diluting solvent (see 5.6) shall not be
integrated. This is so that the final report, after normalization to 100 %, gives the results for all groups and
components for the undiluted sample.
NOTE Analysing high-ethanol samples as well as samples with 15 volume percentage or more of oxygenates
using this application can require specific analysis and reporting procedures and competences (see manufacturer’s
instructions and Clause B.7 ).
9.2 Calculation as a mass fraction in per cent
The integrated peak areas are employed for the calculations. The peaks are arranged according to their
presence in the hydrocarbon group. Table 3 and Table 4 give the relative response factors of hydrocarbon
groups and for oxygenated compounds.
NOTE The response factors are normalized to methane and those for the oxygenated compounds have been
determined experimentally.
After correcting with the relative response factors, the mass contributions for all hydrocarbon groups are
calculated and normalized to a mass fraction of 100 %. The hydrocarbon groups are then classified according
to the hydrocarbon type and carbon number.
Table 3 — FID relative response factors of hydrocarbon groups
Relative response factor
F
RR,HG
Carbon number
Paraffins, Cyclo-alkanes Olefins, Olefins, cyclics Aromatics
(naphthenes)
n- plusiso- n- plusiso-
3 0,916 — 0,916 — —
4 0,906 — 0,906 — —
5 0,899 0,874 0,899 0,874 —
6 0,895 0,874 0,895 0,874 0,811
7 0,892 0,874 0,892 0,874 0,820
8 0,890 0,874 0,890 0,874 0,827
9 0,888 0,874 0,888 0,874 0,832
10 0,887 0,874 0,887 0,874 0,837
11+ 0,887 — — — 0,840
ISO/DIS 22854:2026(en)
Table 4 — FID relative response factors for oxygenated compounds
Relative response factor
Oxygenated compound
F
RR,HG
MTBE 1,334
DIPE 1,317
ETBE 1,242
TAME 1,242
Methanol 3,000
Ethanol 1,870
n-propanol 1,867
iso-propanol 1,742
n-butanol 1,546
iso-butanol 1,390
sec-butanol 1,390
tert-butanol 1,230
2-methyl-2-butanol 1,400
If single compounds, e.g. oxygenate compounds, are determined by a different but accepted method, e.g. EN
[7] [8] [9] [10]
1601 , ASTM D4815 , EN 13132 or ASTM D5599 they shall be excluded from integration. The total
area is then not normalized to 100 %, but to 100 % minus the excluded quantified component. The external
quantification shall be noted in the report.
Calculate the theoretical relative response factors, F , of a particular carbon number for a hydrocarbon
RR,HG
type group (response of methane set to unity) as given in Formula (1); (see Table 1 and Table 2):
(1)
where
M is the molar mass of carbon, equal to 12,011, in g/mol;
C
n is the number of carbon atoms in the group;
C
M is the molar mass of hydrogen, equal to 1,008, in g/mol;
H
n is the number of hydrogen atoms in the group;
H
0,748 7 is the correction factor to set the response of methane to unity.
For each hydrocarbon group (HG) the mass fraction in per cent, w , is calculated as given in Formula (2):
HG
(2)
where
A is the total, corrected signal area for the hydrocarbon group (HG)
HG
9.3 Calculation as a volume fraction in per cent
The conversion from mass fraction to volume fraction is done using the density of the hydrocarbon groups.
The density values at 15 °C of hydrocarbon groups, expressed in kilograms per cubic metre, are shown in
Table 5. The density values of oxygenate compounds at 15 °C are shown in Table 6 (derived from Reference
[11]
).
ISO/DIS 22854:2026(en)
Table 5 — Density at 15 °C of hydrocarbon groups
Density
ρ
HG
Carbon
kg/m
number
Paraffins, Cyclo-alkanes Olefins, Olefins, Aromatics
n- plus iso- (naphthenes) n- plus iso- cyclics
3 506,5 — 520,4 — —
4 577,9 — 613,7 — —
5 626,9 750,3 656,5 773,3 —
6 662,2 760,6 685,9 785,3 884,3
7 688,8 762,1 704,0 790,5 871,6
8 708,4 780,5 719,3 805,2 871,9
9 728,1 792,5 738,2 812,5 878,0
10 734,0 812,8 748,6 817,6 892,8
11+ 759,0 — — — 894,4
[11]
SOURCE: Reference , reproduced with the permission of the authors.
Table 6 — Density at 15 °C of oxygenated compounds
Oxygenated compound Density
ρ
HG
kg/m
MTBE 745,3
DIPE 729,2
ETBE 745,6
di-ethylether 719,2
TAME 775,2
TAEE 774,9
methanol 795,8
ethanol 794,8
n-propanol 810,3
iso-propanol 789,5
n-butanol 813,3
iso-butanol 805,8
sec-butanol 810,6
tert-butanol 791,0
2-methyl-2-butanol 813,5
[11]
SOURCE: Reference , reproduced with the permission of the authors.
The volume fraction in per cent, φ , of the hydrocarbon group (HG) is obtained from the mass fraction,
HG
w , as given in Formula (3)
HG :
(3)
where
ρ is the density of the hydrocarbon group (HG) in kg/m ;
HG
w is the mass percentage of the hydrocarbon group (HG).
HG
ISO/DIS 22854:2026(en)
9.4 Calculation of total oxygen content in mass fraction in per cent
Calculate the oxygen content, w , from all identified oxygenate compounds, i, according to Formula (4):
O
(4)
where
n is the number of oxygen atoms in the molecule, generally 1;
O
M is the molar mass of oxygen, in g/mol;
O
M is the molar mass of the oxygenated compound, in g/mol;
i
w is the mass percentage of the compound in the mixture.
i
EXAMPLE This example calculation uses MTBE (C H O) as the only oxygenate compound and the following
5 12
molar masses:
— C: 12,011
— H: 1,008
— O: 16,000
(5)
9.5 Data report according to automotive motor gasoline specifications
[1]
For the reporting of conformity to automotive motor gasoline specifications, such as EN 228 specific
rounding or summation of results can be necessary. The following results are reported.
— The total content of saturates is determined by summation of (volume fraction) of the paraffins, cyclo-
alkanes (naphthenes) and high-boiling poly-cyclic alkanes. The content of separate saturates (such as
n-hexane) are reported in volume fraction percentage).
— The total olefin content is determined by summation of the (volume fraction) of the olefins and the cyclic
olefins and is reported in volume fraction percentage.
— The total aromatic content is reported unchanged in volume fraction percentage.
— The benzene content is reported in volume fraction percentage.
— The (total) oxygenated compound contents are reported in volume fraction percentage.
— The total oxygen content is calculated according to 9.4. It is reported in mass fraction percentage.
10 Expression of results
10.1 Procedure A and C
The results are reported as a volume fraction percentage or a mass fraction percentage (see 9.5) according
to the following requirements:
— saturates content, aromatics content and olefins content to the nearest 0,1 %;
— benzene content, (total and specific) oxygenates content and total oxygen content to the nearest 0,01 %;
— n-hexane and total C6- to C8-naphthenes to the nearest 0,1 %.

ISO/DIS 22854:2026(en)
10.2 Procedure B
The results for ethanol, ethers and higher alcohols are reported to the nearest 0,1 %.
11 Precision
11.1 General
The precision is given as determined by statistical examination of inter-laboratory test results in accordance
[12]
with ISO 4259:2006 Precision values calculated from the formulae given in Table 7, Table 8 or Table 9
shall be rounded to the appropriate number of decimal places as specified in Clause 10.
Supporting data for Procedures A and B are documented in:
[6] [12]
— CEN/TR 15745 , which consists of calculations according to ISO 4259:2006 ,
[13] [14]
— Reference , which consists of calculations according to EN ISO 4259-1:2017 , and
[5] [15]
— Reference , which consists of calculations according to EN ISO 4259-1:2026 .
NOTE 1 For the higher TAME contents (up to 24,84 volume fraction percentage), too few data were obtained in
[5]
study to derive a full precision statement. The data presented in Table 7 are therefore only ind
...