Aerospace series - Cable, electrical, fire resistant - Single and twisted multicore assembly, screened (braided) and jacketed - Operating temperatures between - 65 °C and 260 °C - Part 001: Technical specification

This document specifies the required characteristics and test procedures for fire resistant or fire proof
electrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of
600 V ac, a frequency of maximum 2 000 Hz and a long term temperature of up to 260 °C (ambient
temperature plus temperatures rise in conductor).
These cables shall also maintain a specific dielectric strength when they are subjected to a flame of
1 100 °C after five (5) minutes (fire resistant) or 15 minutes (fire proof) exposure.

Luft- und Raumfahrt - Feuerberständige elektrische Leitungen - Einzel- und mehradrig verdrillte Leitungen, geschirmt (Geflecht) und ummantelt - Betriebstemperaturen zwischen - 65 °C und 260 °C - Teil 001: Technische Lieferbedingungen

Dieses Dokument legt die Anforderungen an und Prüfverfahren für feuerbeständige oder feuerfeste elektrische Leitungen zur Verwendung in elektrischen Bordnetzen fest. Sie sind bei einer Nennwechselspan¬nung von 600 V ac, einer Frequenz von höchstens 2 000 Hz sowie einer Langzeittemperatur von bis zu 260 °C (Umgebungstemperatur zuzüglich des Temperaturanstiegs im Leiter) zu betreiben.
Diese Leitungen müssen außerdem eine bestimmte Spannungsfestigkeit beibehalten, wenn sie fünf (5) min (feuerbeständig) oder 15 min (feuerfest) einer Flamme von 1 100 °C ausgesetzt sind.

Série aérospatiale — Câbles électriques blindés résistant au feu — Simple et multifilaire blindé (tresse) gainé — Températures de fonctionnement comprises entre – 65 °C et 260 °C — Partie 001 : Spécification technique

Aeronavtika - Električni ognjevzdržni kabli - Enožilni in večžilni prepleteni kabli, oklopljeni (opleteni) in oplaščeni - Delovne temperature med –65 °C in 260 °C - 001. del: Tehnična specifikacija

Ta dokument določa potrebne značilnosti in preskusne postopke za ognjevzdržne ali negorljive električne kable za uporabo v električnih sistemih letal. Uporabljajo naj se pri nazivni napetosti izmeničnega toka 600 V, največji frekvenci 2000 Hz in dolgotrajni temperaturi do 260 °C (temperatura okolice s povišanjem temperatur v prevodniku).
Kadar so izpostavljeni plamenu temperature 1100 °C, ti kabli po petih (5) minutah (ognjevzdržni) ali 15 minutah (negorljivi) izpostavljenosti ohranijo tudi določeno dielektrično moč.

General Information

Status
Published
Publication Date
08-Aug-2019
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
02-Jul-2019
Due Date
06-Sep-2019
Completion Date
09-Aug-2019

Relations

Buy Standard

Standard
EN 4608-001:2019
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 4608-001:2019
01-september-2019
Nadomešča:
SIST EN 4608-001:2009
Aeronavtika - Električni ognjevzdržni kabli - Enožilni in večžilni prepleteni kabli,
oklopljeni (opleteni) in oplaščeni - Delovne temperature med –65 °C in 260 °C - 001.
del: Tehnična specifikacija
Aerospace series - Cable, electrical, fire resistant - Single and twisted multicore
assembly, screened (braided) and jacketed - Operating temperatures between - 65 °C
and 260 °C - Part 001: Technical specification
Luft- und Raumfahrt - Feuerberständige elektrische Leitungen - Einzel- und mehradrig
verdrillte Leitungen, geschirmt (Geflecht) und ummantelt - Betriebstemperaturen
zwischen - 65 °C und 260 °C - Teil 001: Technische Lieferbedingungen
Série aérospatiale Câbles électriques blindés résistant au feu Simple et multifilaire
blindé (tresse) gainé Températures de fonctionnement comprises entre 65 °C et 260 °C
Partie 001 : Spécification technique
Ta slovenski standard je istoveten z: EN 4608-001:2019
ICS:
13.220.99 Drugi standardi v zvezi z Other standards related to
varstvom pred požarom protection against fire
29.060.20 Kabli Cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
SIST EN 4608-001:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 4608-001:2019

---------------------- Page: 2 ----------------------

SIST EN 4608-001:2019


EN 4608-001
EUROPEAN STANDARD

NORME EUROPÉENNE

June 2019
EUROPÄISCHE NORM
ICS 49.060
English Version

Aerospace series - Cable, electrical, fire resistant - Single
and twisted multicore assembly, screened (braided) and
jacketed - Operating temperatures between - 65 °C and
260 °C - Part 001: Technical specification
Série aérospatiale - Câbles électriques blindés résistant Luft- und Raumfahrt - Feuerbeständige elektrische
au feu - Simple et multifilaire blindé (tresse) gainé - Leitungen - Einzel- und mehradrig verdrillte Leitungen,
Températures de fonctionnement comprises entre - 65 geschirmt (Geflecht) und ummantelt -
°C et 260 °C - Partie 001 : Spécification technique Betriebstemperaturen zwischen - 65 °C und 260 °C -
Teil 001: Technische Lieferbedingungen
This European Standard was approved by CEN on 14 January 2019.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 4608-001:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 4608-001:2019
EN 4608-001:2019 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Materials and construction of cables . 5
5 Required characteristics . 5
6 Tests methods . 5
7 Qualification and acceptance conditions. 10
8 Identification, marking . 12
9 Packaging, labelling and delivery length . 12

2

---------------------- Page: 4 ----------------------

SIST EN 4608-001:2019
EN 4608-001:2019 (E)
European foreword
This document (EN 4608-001:2019) has been prepared by the Aerospace and Defence Industries
Association of Europe - Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of
ASD, prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by December 2019, and conflicting national standards shall
be withdrawn at the latest by December 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 4608-001:2006.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia,
Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN 4608-001:2019
EN 4608-001:2019 (E)
1 Scope
This document specifies the required characteristics and test procedures for fire resistant or fire proof
electrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of
600 V ac, a frequency of maximum 2 000 Hz and a long term temperature of up to 260 °C (ambient
temperature plus temperatures rise in conductor).
These cables shall also maintain a specific dielectric strength when they are subjected to a flame of
1 100 °C after five (5) minutes (fire resistant) or 15 minutes (fire proof) exposure.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 2234, Aerospace series — Cable, electrical, fire resistant — Technical specification
EN 2235, Aerospace series — Single and multicore electrical cables, screened and jacketed — Technical
specification
EN 3475-100 (all parts), Aerospace series — Cables, electrical, aircraft use — Test methods — Part 100:
General
EN 3838, Aerospace series — Requirements and tests on user-applied markings on aircraft electrical cables
EN 4608-002, Aerospace series — Cable, electrical, fire resistant — Single and twisted multicore assembly,
screened (braided) and jacketed — Operating temperatures between – 65 °C and 260 °C — Part 002:
General
EN 4608-005, Aerospace series — Cable, electrical, fire resistant — Single and twisted multicore assembly,
screened (braided) and jacketed — Operating temperatures between – 65 °C and 260 °C — Part 005: DW
family — Lightweight two-core gauge 24 for data transmission — UV Laser printable — Product standard
EN 9133, Aerospace series — Quality Management Systems — Qualification Procedure for Aerospace
Standard Products
1)
ISO 2574, Aircraft — Electrical cables — Identification marking
2)
TR 6058, Aerospace series — Cable code identification list
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 3475-100 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp

1) Published by : International Organization for Standardization (ISO), http://www.iso.ch/
2) Published as ASD-STAN Technical Report at the date of publication of this European Standard by AeroSpace and
Defence industries Association of Europe - Standardization (ASD-STAN) (http://www.asd-stan.org/)
4

---------------------- Page: 6 ----------------------

SIST EN 4608-001:2019
EN 4608-001:2019 (E)
4 Materials and construction of cables
4.1 General
The individual cores shall conform to EN 2234 and applicable product standard.
4.1.1 Materials
The material shall conform to the applicable product standard.
The materials used shall have no corrosive effect upon the conductors and screens and shall not be
susceptible to attack by mould and other micro-organisms.
4.1.2 Construction
The construction shall conform to EN 2234, 4.1.
4.2 Construction of cables
4.2.1 Assembly
The lay length of the outer layer shall not be less than eight (8) times and not more than 16 times the
nominal diameter of the cabled cores. The cores shall not be spliced.
4.2.2 Screened cables
Shielding shall conform to EN 2235, 4.3.3.
Efficiency of shielding is not required during the flame exposure.
4.3 Colour
The colour of the outer layer and stripes shall be in accordance with EN 4608-002.
5 Required characteristics
The required characteristics for cables tested according to 6.1 shall conform to the values specified in the
product standard or in
...