IEC 62722-2-1:2023 specifies the performance requirements for LED luminaires, together with the test methods and conditions. It applies to LED luminaires for general lighting purposes. Semi-luminaires are not covered under the scope of this document. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:  
alignment with IEC 62717:2014, IEC 62717:2014/AMD1:2015 and IEC 62717:2014/AMD2:2019;
clarification of temperature requirements for the maintenance test, in 10.2 and Annex A;
introduction of a new Annex C on methods for calculation and measurements of parameters for extension of electric and photometric data.

  • Standard
    57 pages
    English and French language
    sale 15% off

IEC 60598-2-2:2023 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. It also specifies requirements for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum).
This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition (there are no major technical changes, see Annex D):  
The requirements specific to recessed luminaries given in IEC 60598-1 are now incorporated in this Part 2-2.
The requirements for air-handling luminaires given in IEC 60598-2-19 are now incorporated in this Part 2-2.
The references to Part 1 have been updated.

  • Standard
    49 pages
    English language
    sale 15% off

IEC 60598-2-18:2022 specifies requirements for fixed luminaires intended for use in water, or in contact with water, in, for example, the basins of swimming pools, fountains, paddling pools, and garden pools, and for use with electric light sources.
This third edition cancels and replaces the second edition published in 1993 and Amendment 1:2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:  
references to Part 1 have been updated;
some subclauses have been renumbered;
the standard has been redrafted such that it is applicable to both filament lamps and LED light sources;
marking requirements have been updated and 18.5.3 of the previoius edition has been deleted;
18.10.3 of the previous edition has been deleted, as it is no longer relevant, following the update of requirements for cross-sectional areas of external and internal cables in Section 5 of Part 1;
18.10.4 and 18.10.5 of the previous edition renumbered as 18.11.4 and 18.11.5 in this edition have been adapted to allow the use of an alternative waterproof multi-core cable that conforms to the waterproof test of Annex D and Annex E of EN 50525‑2‑21:2011 or to an equivalent regional standard;
in 18.11 (18.10 in the previous edition), the cross-sectional area of wiring has been aligned with Part 1;
in 18.11 (18.10 in the previous edition), the types of cables have been updated with alternative regional cables.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 62722-1:2022 is available as IEC 62722-1:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62722-1:2022 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this document are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- The reference to and use of the measurement methods for non-active power consumption in accordance with IEC 63103 have been added.
- The pictograms of Annex C have been updated to represent modern light sources.

  • Standard
    38 pages
    English and French language
    sale 15% off

IEC 60598-2-20:2022 is available as IEC 60598-2-20:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-2-20:2022 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- specific provisions for temporarily installed protected lighting (TPL) chains have been added;
- new terms and definitions have been added.

  • Standard
    46 pages
    English and French language
    sale 15% off

IEC 60598-1:2020 is available as IEC 60598-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
- Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
- Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
- Addition of Subclause 3.3.25, UV protection of cable;
- Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
- Revision of the requirements for functional earth and protective earth;
- Addition of Clause 4.35, Protection against fast rotating parts;
- Revision of Clause 3.2, Rated voltage marking;
- Revision of Subclause 5.2.10, Cord anchorage;
- Revision of Annex G for touch current and protective conductor current test set-up;
- Addition of requirements for constant light output function and programmable current output;
- Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
- Introduction of PELV;
- Introduction of Ethernet power supply connection for luminaires (PoE);
- Section 9, Introduction of IPX9;
- Addition of Subclause 3.3.26 for wall mounted luminaires;
- Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
- Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
- Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
- Revision of Subclause 10.2.2, alternative DC electric strength test;
- Revision of Annex D for recessed luminaires;
- Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
- Revision of use of bridging capacitors in luminaires;
- Revision of electrical connection to class III plugs.
The contents of the Interpretation sheet 1 (2023-08) have been included in this copy.

  • Standard
    229 pages
    English language
    sale 15% off
  • Standard
    472 pages
    English and French language
    sale 15% off

IEC 60598-2-23:2020 specifies requirements for extra-low-voltage lighting systems for ELV light sources, intended for ordinary interior use on supply voltages not exceeding 1 000 V. The luminaires, being connected in parallel, are supplied via freely suspended continuous supporting conductors or profiles, the current in the ELV part of the system not exceeding 25 A.
This second edition cancels and replaces the first edition published in 1996 and Amendment 1:2000. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A):
a) The title has been modified to allow the inclusion of other light sources;
b) The scope has been updated to be aligned with the other parts of the IEC 60598-2 series and to include other light sources;
c) Normative references and the reference to transformer and controlgear standards have been updated;
d) The short circuit test (23.7.6.1 and 23.7.6.2) was removed and reference is now made to the same test in Part 1.

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 60598-2-1:2020 specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V.
This second edition cancels and replaces the first edition published in 1979 and Amendment 1:1987. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A):
a) the scope has been modified to be in line with Part 1 to include all electric light sources,
b) references to Part 1 have been updated.

  • Standard
    13 pages
    English and French language
    sale 15% off

IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V.
This second edition cancels and replaces the first edition published in 1984 and Amendement 2:1990. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) extension of the applicable scope from light source to electric light source and replacement of "tungsten filament, tubular fluorescent and other discharge lamps" with "electric light source" in 17.1.
b) consideration of the fact that there are many LED luminaires with non-replaceable light source, and light source without a glass bulb, or with low operation temperature: the applicable scope of relevant clauses therefore only applies to replaceable light source luminaires with a glass bulb lamp, or with high surface temperature.

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC 60598-2-4:2017 is available as IEC 60598-2-4:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-2-4:2017 specifies requirements for portable general purpose luminaires for indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with or incorporating electrical light sources on supply voltages not exceeding 250 V.
This third edition cancels and replaces the second edition published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- alignment with IEC 60598-1;
- modification of the scope, classification and requirements to cover portable luminaires for both indoor and outdoor applications, by introducing the requirements already listed in IEC 60598-2-7;
NOTE In this edition of IEC 60598-2-4 all requirements listed in IEC 60598-2-7 have been incorporated. As a consequence, IEC 60598-2-7 will be withdrawn after publication of this standard.
- modification of the scope to cover all electrical light sources (it was previously limited to tungsten filament, tubular fluorescent and other discharge lamps);
- introduction of the symbol for luminaires which are other than ordinary, but suitable for indoor applications only (e.g. luminaire using PVC cable);
- modification in the detail of test to clarify that the stability test on an inclined plane (see 4.7.3) shall be carried out with the light source(s) in place;
- modification of the minimum degree of protection against dust and moisture for portable luminaires for outdoor use from IPX3 to IPX4 (see 4.5.2); as a consequence, the requirements for cable entry position, as given in IEC 60598-2-7:1982, 7.6.3 were deleted as they are covered by IPX4;
- modification of the requirements for the acceptance criteria of plug and socket outlet;
- modification of the IP test requiring the most unfavourable of the overturned positions to cover all classes (and not only class II luminaires as in 7.13.1 of IEC 60598-2-7:1982).

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60598-2-5:2015 specifies requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V. This third edition cancels and replaces the second edition published in 1998, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: it introduces requirements for the glass breaking test.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 60598-2-20:2014 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. For combinations where rope lights (also known as sealed lighting chains) are included, see IEC 60598-2-21. This fourth edition cancels and replaces the third edition (2010). This edition includes the following significant technical changes with respect to the previous edition, where the requirements for rope lights (sealed lighting chains) have been removed and are now dealt with in IEC 60598-2-21. The contents of the corrigendum of December 2016 have been included in this copy.
This publication is to be read in conjunction with IEC 60598-1:2014

  • Standard
    41 pages
    English and French language
    sale 15% off

IEC 60598-2-21:2014 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V.
The contents of the corrigendum of December 2016 have been included in this copy.
This publication is to be read in conjunction with IEC 60598-1:2014.

  • Standard
    34 pages
    English and French language
    sale 15% off

IEC 62722-1:2014 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this standard are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed. This first edition cancels and replaces IEC PAS 62722-1 published in 2011 and constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC PAS 62722-1.
a) The inclusion of more precise requirements for the comparison of the photometric distribution shape, with the comparison method given in Annex D.
b) Further regional standards added to the schedule given in Annex A.

  • Standard
    36 pages
    English and French language
    sale 15% off

IEC 60598-1:2014 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This eighth edition cancels and replaces the seventh edition published in 2008. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition:
a) requirements to support the construction methods for new LED luminaires entering the market;
b) photobiological requirements extended;
c) more precise requirements for insulation between different types of electrical circuit;
d) other general updates and improvements. The contents of the corrigenda of October 2015, of December 2015, of May 2017 and interpretation sheet 1 of May 2016 have been included in this copy.

  • Standard
    417 pages
    English and French language
    sale 15% off

IEC 60598-2-24:2013 series specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials but where the risk of explosion in the atmosphere does not exist. The luminaires are for use with electric light sources on supply voltages not exceeding 1 000 V. This standard specifically excludes requirements for luminaires for use in explosive gas atmospheres and explosive dust atmospheres. This second edition cancels and replaces the first edition published in 1997. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) change of required degree of protection from IP6X to IP4X to harmonize with the international wiring rules;
b) temperature limits introduced for glass surface of any light source exposed to risk of dust.
This publication is to be read in conjunction with IEC 60598-1:2008.

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC 60598-2-11:2013 specifies requirements for household aquarium luminaires incorporating electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Subclause 11.1, change of the scope to open the standard for all kinds of electrical light sources.
b) Subclause 11.4.2, change of the definition in order to clarify non-permanently attached aquarium luminaire.
c) Subclause 11.11.3, for indoor operated aquarium luminaire, change of the size of external cable to at least 0,75 mm2 instead of 1,0 mm2 in the former edition.
This publication is to be read in conjunction with IEC 60598-1:2008.

  • Standard
    42 pages
    English and French language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60598-2-12:2013 specifies requirements for mains socket-outlet mounted nightlights for use with electric light sources, on supply voltages not exceeding 250 V a.c. 50/60 Hz. This second edition cancels and replaces the first edition published in 2006. It constitutes a technical revision for harmonization of thermal tests in 12.13 to relevant parts of 10.12.1 of IEC 60598-2-10.
This publication is to be read in conjunction with IEC 60598-1:2008.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60598-2-8:2013 specifies requirements for handlamps and similar portable luminaires which are held in the hand, hooked up or resting on a surface for use with electric light sources on supply voltages not exceeding 250 V. This third edition cancels and replaces the second edition, published in 1996, its Amendment 1 (2000) and its Amendment 2 (2007). It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) The requirements have been updated to make them consistent and to solve contradicting requirements introduced in the Amendment 2. In that amendment, a requirement was introduced specifying that handlamp shall always be classified as rough service luminaire only. The implication of this statement was that according to 4.13.4 of Part 1 this kind of luminaire shall always be IP54. This requirements is in contradiction with several points of this Part 2 where it is considered acceptable for ordinary luminaires (e.g. 8.11.1, 8.11.2 and 8.13.1).
b) Furthermore, the contradiction between the requirement in 8.7.1 and 8.7.2 regarding the type of material used for the protective cover has been corrected.
This publication is to be read in conjunction with IEC 60598-1:2008.

  • Standard
    29 pages
    English and French language
    sale 15% off

IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled luminaires. This third edition cancels and replaces the second edition published in 1996 and its Amendment 1 (1997), of which is constitutes a technical revision. The changes introduced by this new edition are those required to maintain consistency later versions of IEC 60598-1 that have been published since the previous edition of this standard.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC/TR 62696:2011(E) covers the testing and classification of luminaires according to IEC 62262. The application of an IK rating to a luminaire is considered to be a performance issue and is not directly related to the safety provisions of IEC 60598 standards covering luminaire safety.

  • Technical report
    6 pages
    English language
    sale 15% off

IEC/PAS 62722-2-1:2011(E) specifies the performance requirements for LED luminaires, together with the test methods and conditions, required to show compliance with this PAS. It applies to LED luminaires for general lighting purposes, where claims of operational performance are made.

  • Technical specification
    16 pages
    English language
    sale 15% off

IEC/PAS 62722-1:2011(E) covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V where claims of operational performance are made. Unless otherwise detailed performance data covered under the scope of this PAS are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed.

  • Technical specification
    14 pages
    English language
    sale 15% off