Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions

This European Standard specifies the terms and definitions for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either, air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling. This European Standard does not apply to heat pumps for domestic hot water, although certain definitions can be applied to these.
This European Standard applies to:
- factory-made units that can be ducted,
- factory-made liquid chilling packages with integral condensers or for use with remote condensers,
- factory-made units of either fixed capacity or variable capacity by any means, and
- air-to-air air conditioners which can also evaporate the condensate on the condenser side.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, this European Standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This European Standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard, see EN 15218 for evaporatively cooled condenser units.
Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.
NOTE 1   Part load testing of units is dealt with in prEN 14825.
NOTE 2   All the symbols given in this text should be used regardless of the language used.

Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumbeheizung und Kühlung - Teil 1: Begriffe

Diese Europäische Norm legt die Begriffe für die Einstufung und Leistung von Luftkonditionierern, Flüssigkeitskühlsätzen,
Wärmepumpen, die entweder Luft oder Wasser oder Sole als Wärmeträger nutzen, mit elektrisch
angetriebenen Verdichtern für die Raumbeheizung und/oder Kühlung fest. Diese Europäische Norm gilt
nicht speziell für Wärmepumpen zum Erwärmen von Brauchwasser, obwohl bestimmte Definitionen auf diese
angewendet werden können.
Diese Europäische Norm gilt für:
- fabrikmäßig zusammengebaute Geräte, die mit Luftkanalanschlüssen versehen sein können,
- fabrikmäßig zusammengebaute Flüssigkeitskühlsätze, die mit eingebauten Verflüssigern oder mit getrennt
angeordneten Verflüssigern betrieben werden,
- fabrikmäßig zusammengebaute Geräte mit fest eingestellter oder durch beliebige Vorrichtungen zu verändernder
Leistung (variable Leistung), und
- Luft/Luft-Luftkonditionierer, die das Kondensat auf der Verflüssigerseite verdampfen.
Kompaktgeräte, Einzelgeräte in Split-Bauweise und Multi-Split-Systeme fallen unter den Anwendungsbereich
dieser Norm. Geräte mit Ein- und Zweikanal-Systemen werden ebenfalls in dieser Norm behandelt.
Wenn die Geräte aus mehreren Teilen bestehen, gilt diese Europäische Norm mit der Ausnahme von Flüssigkeitskühlsätzen
mit getrennt angeordnetem Verflüssiger nur für Teile, die als vollständige Baueinheit konstruiert
und geliefert werden.
Diese Europäische Norm gilt hauptsächlich für Wasser- und Solekühlsätze, kann jedoch bei Vereinbarung auf
weitere Flüssigkeitskühlsätze angewendet werden.
Geräte, deren Verflüssiger durch Belüftung und durch Verdampfung von zusätzlichem, von außen zugeführtem
Wasser gekühlt wird, werden in dieser Norm nicht behandelt, sind jedoch Gegenstand von EN 15218, die
sich auf verdunstungsgekühlte Verflüssiger bezieht.
Anlagen für die Beheizung und/oder Kühlung industrieller Prozesse fallen nicht in den Anwendungsbereich
dieser Norm.
ANMERKUNG 1 Die Prüfung von Geräten unter Teillastbedingungen ist in prEN 14825 festgelegt.
ANMERKUNG 2 Alle in diesem Dokument enthaltenen Symbole sollten unabhängig von der verwendeten Sprache
verwendet werden.

Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigeration des locaux - Partie 1: Termes et définitions

La présente Norme européenne spécifie les termes et définitions relatifs à la détermination des caractéristiques de performance des climatiseurs à condensation par air et à condensation par eau, des groupes refroidisseurs de liquide et des pompes à chaleur utilisant l'air, l'eau ou l'eau glycolée comme fluide caloporteur, avec compresseur entraîné par moteur électrique, lorsqu'ils sont utilisés pour le chauffage et/ou la réfrigération des locaux. La présente Norme européenne ne s'applique pas spécifiquement aux pompes à chaleur utilisées pour l'eau chaude sanitaire, bien que certaines définitions puissent leur être applicables.
La présente Norme européenne s'applique :
-   aux appareils fabriqués en usine qui peuvent être raccordés ;
-   aux groupes refroidisseurs de liquide autonomes fabriqués en usine ou conçus pour être utilisés avec des condenseurs fournis séparément ;
-   aux appareils fabriqués en usine de capacité fixe ou variable par tous moyens ; et
-   aux climatiseurs air/air qui peuvent également évaporer les condensats du côté condenseur.
La présente norme couvre les systèmes monoblocs, à deux éléments séparés et multi-split. La présente norme couvre les appareils à simple et à double raccordement.
Dans le cas d'appareils à éléments séparés, la présente Norme européenne ne s'applique qu'aux appareils conçus et fournis comme un ensemble, sauf pour ce qui concerne les groupes refroidisseurs de liquide avec condenseur séparé.
La présente Norme européenne est principalement destinée aux groupes refroidisseurs d'eau et d'eau glycolée mais peut être utilisé, après accord, pour d'autres liquides.
Les appareils ayant leur condenseur refroidi par air et par évaporation d'eau extérieure supplémentaire ne sont pas couverts par la présente norme, voir l'EN 15218 pour les appareils ayant leur condenseur refroidi par évaporation.
La présente norme ne s'applique pas aux installations utilisées pour le chauffage et/ou le refroidissement des procédés industriels.
NOTE 1   Les essais à charge partielle des appareils sont traités dans le prEN 14825.
NOTE 2   Il convient d'utiliser tous les symboles spécifiés dans le présent document, quelle que soit la langue utilisée.

Klimatske naprave, enote za tekočinsko hlajenje in toplotne črpalke z električnimi kompresorji za segrevanje in hlajenje prostora - 1. del: Izrazi in definicije

Ta evropski standard določa izraze in definicije za ocenjevanje in delovanje klimatskih naprav, enot za tekočinsko hlajenje in toplotnih črpalk, ki uporabljajo zrak, vodo ali slanico kot medij za transport toplote, z električnimi kompresorji, kadar se uporabljajo za segrevanje in/ali ohlajevanje prostora. Ta evropski standard ne velja za toplotne črpalke za gospodinjsko vročo vodo, čeprav lahko za njih veljajo določene definicije. Ta evropski standard velja za: - tovarniško izdelane enote, ki se lahko uporabljajo v ceveh; - tovarniško izdelane enote za tekočinsko hlajenje z vgrajenim kondenzatorjem ali za uporabo z oddaljenim kondenzatorjem; - tovarniško izdelane enote s fiksno ali na kakršen koli način spremenljivo zmogljivostjo in - klimatske naprave zrak-zrak, ki prav tako lahko uparijo kondenzat na strani kondenzatorja. Ta standard zajema pakirane enote in sisteme z enim ali več razcepi. Ta standard zajema enote z enojnim in dvojnim jaškom. Pri enotah, sestavljenih iz več kosov, ta evropski standard velja samo za tiste, ki so načrtovane in dostavljene kot celoten paket, razen za enote za tekočinsko hlajenje z oddaljenim kondenzatorjem. Ta evropski standard je prvotno namenjen enotam za hlajenje z vodo in slanico, vendar se lahko po dogovoru uporablja tudi za druge tekočine. Enote, ki svoj kondenzator hladijo z zrakom in z izhlapevanjem zunanje dodatne vode, niso zajete s tem standardom, glej EN 15218 za kondenzatorske enote, hlajene z izhlapevanje. Inštalacije, uporabljene za gretje in/ali hlajenje industrijskih procesov, niso zajete v tem standardu.

General Information

Status
Withdrawn
Publication Date
25-Oct-2011
Withdrawal Date
24-Sep-2013
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
25-Sep-2013
Completion Date
25-Sep-2013

Relations

Buy Standard

Standard
EN 14511-1:2012
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luftkonditionerer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumbehezung und Kühlung - Teil 1: BegriffeClimatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigération des locaux - Partie 1: Termes et définitionsAir conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions27.080Heat pumps91.140.30VLVWHPLVentilation and air-conditioning01.040.23Fluid systems and components for general use (Vocabularies)23.120QDSUDYHVentilators. Fans. Air-conditionersICS:Ta slovenski standard je istoveten z:EN 14511-1:2011SIST EN 14511-1:2012en,fr,de01-januar-2012SIST EN 14511-1:2012SLOVENSKI
STANDARDSIST EN 14511-1:20081DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14511-1
October 2011 ICS 01.040.91; 91.140.30 Supersedes EN 14511-1:2007English Version
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions
Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigeration des locaux - Partie 1: Termes et définitions
Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumbeheizung und Kühlung - Teil 1: Begriffe This European Standard was approved by CEN on 20 August 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14511-1:2011: ESIST EN 14511-1:2012

Installations used for heating and/or cooling of industrial processes are not within the scope of this standard. NOTE 1 Part load testing of units is dealt with in prEN 14825. NOTE 2 All the symbols given in this text should be used regardless of the language used. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 air conditioner encased assembly or assemblies designed as a unit to provide delivery of conditioned air to an enclosed space (room for instance) or zone NOTE 1 It includes an electrically operated refrigeration system for cooling and possibly dehumidifying the air. NOTE 2 It can have means for heating, circulating, cleaning and humidifying the air. If the unit provides heating by reversing the refrigerating cycle then it is a heat pump. 2.2 heat pump encased assembly or assemblies designed as a unit to provide delivery of heat NOTE 1 It includes an electrically operated refrigeration system for heating. SIST EN 14511-1:2012

2.9 double-duct air conditioner air conditioner placed in the conditioned space near a wall, in which the condenser intake air is introduced from the outdoor environment by a small duct and the condenser discharge air is rejected to the outdoor environment by a second small duct 2.10 liquid chilling package factory-made unit designed to cool liquid, using an evaporator, a refrigerant compressor, an integral or remote condenser and appropriate controls NOTE It may have means for heating which can be reversing the refrigerating cycle, like a heat pump. 2.11 heat recovery liquid chilling package factory-made liquid chilling package designed for the purpose of chilling liquid and recovering of heat 2.12 heat recovery recovery of heat rejected by the unit whose primary control is in the cooling mode by means of either an additional heat exchanger (e.g. a liquid chiller with an additional condenser) or by transferring the heat through the refrigerating system for use to unit whose primary control remains in the heating mode (e.g. variable refrigerant flow) 2.13 indoor heat exchanger heat exchanger which is designed to transfer heat to the indoor part of the building or to the indoor hot water supplies or to remove heat from these SIST EN 14511-1:2012

air from the outdoor environment
2.20 water loop closed circuit of water maintained within a temperature range on which the units in cooling mode reject heat and the units in heating mode take heat 2.21 total cooling capacity PC heat given off from the heat transfer medium to the unit per unit of time, expressed in Watt
2.22 latent cooling capacity PL capacity of the unit for removing latent heat from the evaporator intake air, expressed in Watt 2.23 sensible cooling capacity PS capacity of the unit for removing sensible heat from the evaporator intake air, expressed in Watt 2.24 heating capacity PH heat given off by the unit to the heat transfer medium per unit of time, expressed in Watt SIST EN 14511-1:2012

2.33 rating conditions standardised conditions provided for the determination of data which are characteristic for the unit, especially:  heating capacity, power input, COP in heating mode; SIST EN 14511-1:2012
...