Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking

This European Standard applies to standard boilers and low temperature boilers with forced draught burners with a nominal heat output not exceeding 1 000 kW, which are operated either with negative pressure (natural draught boilers) or with positive pressure (pressurised boiler) in the combustion chamber, in accordance with the boiler manufacturer’s instruction.
This standard specifies the necessary terminology, the requirements on the materials and testing of them, and marking requirements for heating boilers.
Particular requirements for boilers which can be used with open vented systems are contained in EN 303 4.
The requirements of this standard apply to heating boilers which are tested on an authorised test rig.
Boilers in accordance with this standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is restricted to 100 °C. The maximum allowable operating pressure is 8 bar.
For boilers with a built in or attached water heater (storage or continuous flow heater) this standard only applies to the parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part).
This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, oil or gas fired condensing boilers and boilers with oil vaporisation burners. For these boilers there are further requirements.

Heizkessel - Teil 1: Heizkessel mit Gebläsebrenner - Begriffe, Allgemeine Anforderungen, Prüfung und Kennzeichnung

Diese Europäische Norm gilt für Kessel von Zentralheizungen (Heizkessel) mit Gebläsebrennern bis zu einer Nennwärmeleistung von 1 000 kW, die nach den Festlegungen des Kesselherstellers entweder mit Unterdruck (Naturzugkessel) oder mit Überdruck (Überdruckkessel) im Brennraum betrieben werden.
Diese Norm legt die notwendigen Begriffe sowie die Anforderungen an Werkstoffe, Prüfungen und Kennzeichnungen für Heizkessel fest.
Für Heizkessel, die in offenen Heizungsanlagen betrieben werden, gilt EN 303-4.
Die Anforderungen dieser Norm gelten für Heizkessel, die auf einem zugelassenen Prüfstand geprüft werden.
Heizkessel in Übereinstimmung mit dieser Norm sind für die Beheizung von zentralen Heizungsanlagen bestimmt, deren Wärmeträger Wasser mit einer maximal zulässigen Betriebstemperatur von 100°C ist. Der maximal zulässige Betriebsdruck ist 8 bar.
Diese Norm gilt nur für die Bauelemente von Heizkesseln und Wassererwärmern (Speicher- oder Durchlaufwassererwärmer), die den Betriebsbedingungen des Heizkessels zwangsläufig unterworfen sind (Heizungsteil).
Die Norm gilt nicht für Gasheizkessel mit atmosphärischen Brennern, Heizkessel für feste Brennstoffe und Heizkessel mit Ölverdampfungsbrennern. Für diese Kessel sind andere Anforderungen zu erfüllen.

Chaudières de chauffage - Partie 1 : Chaudières avec brûleurs à air soufflé - Terminologie, prescriptions générales, essais et marquage

La présente Norme européenne s'applique aux chaudières de chauffage central (chaudières de chauffage) équipées de brûleurs à air soufflé d'une puissance utile nominale inférieure ou égale à 1 000 kW, fonctionnant soit en dépression (chaudières à tirage naturel), soit en pression (chaudières pressurisées) dans la chambre de combustion, selon les indications du fabricant de la chaudière.
La présente norme spécifie la terminologie nécessaire, les exigences relatives aux matériaux et aux essais qui s'y rapportent, ainsi que les exigences de marquage pour les chaudières de chauffage.
Pour les chaudières qui peuvent être utilisées avec un vase d’expansion ouvert, les exigences particulières de construction sont précisées dans l'EN 303-4.
Les exigences de la présente norme s'appliquent aux chaudières de chauffage soumises à essai sur un banc d'essai agréé.
Les chaudières conformes à la présente norme sont conçues pour le chauffage d'installations de chauffage central dont le fluide caloporteur est l'eau et dont la température de fonctionnement maximale autorisée est limitée à 100 °C. La pression de service maximale autorisée est de 8 bar.
Pour les chaudières mixtes et les chauffe-eau (dispositif de chauffage à accumulation ou à production instantanée), la présente norme s'applique uniquement aux éléments qui sont nécessairement soumis aux conditions de fonctionnement de la chaudière de chauffage (partie chauffage).
La présente norme ne s'applique pas aux chaudières à gaz à brûleur atmosphérique, aux chaudières pour combustibles solides, ni aux chaudières à brûleur fioul à caléfaction. Ces chaudières sont soumises à d'autres exigences.

Kotli za gretje - 1. del: Kotli z ventilatorskimi gorilniki - Terminologija, splošne zahteve, preskušanje in označevanje

Ta evropski standard se uporablja za standardne kotle in nizkotemperaturne kotle z ventilatorskimi gorilniki z nazivno izhodno toploto, ki ne presega 1000 kW, ki delujejo bodisi z negativnim tlakom (kotli na naraven vlek) bodisi s pozitivnim tlakom (kotli pod tlakom) v zgorevalni komori, v skladu z navodili proizvajalca kotla. Ta standard določa potrebno terminologijo, zahteve glede materialov in njihovo preskušanje ter zahteve glede označevanja kotlov za gretje. Posebne zahteve za kotle, ki jih je mogoče uporabljati z odprtimi prezračevalnimi sistemi, so v standardu EN 303-4. Zahteve tega standarda veljajo za grelne kotle, ki se preskušajo na pooblaščeni napravi za preskušanje. Kotli za gretje v skladu s tem standardom so namenjeni za gretje v sistemih centralnega ogrevanja, pri čemer toploto prenaša voda. Najvišja dovoljena obratovalna temperatura je 100 °C, najvišji dovoljen obratovalni tlak pa 8 barov.  V zvezi s kotli z vgrajenim ali pritrjenim (termoakumulacijskim ali pretočnim) grelnikom vode se ta standard uporablja le za tiste dele grelnika vode, za katere obvezno veljajo obratovalni pogoji kotla za gretje (grelni del). Ta standard se ne uporablja za plinske kotle z atmosferskimi gorilniki, kotle na trda goriva, kondenzacijske kotle na nafto ali plin in kotle z oljnimi uparjalniki. Za te kotle veljajo še dodatne zahteve.

General Information

Status
Published
Public Enquiry End Date
31-Jul-2016
Publication Date
12-Nov-2017
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
07-Nov-2017
Due Date
12-Jan-2018
Completion Date
13-Nov-2017

Relations

Buy Standard

Standard
EN 303-1:2017
English language
37 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 303-1:2016
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 303-1:2017
01-december-2017
1DGRPHãþD
SIST EN 15034:2007
SIST EN 15034:2007/AC:2008
SIST EN 303-1:1999
SIST EN 303-1:1999/A1:2004
.RWOL]DJUHWMHGHO.RWOL]YHQWLODWRUVNLPLJRULOQLNL7HUPLQRORJLMDVSORãQH
]DKWHYHSUHVNXãDQMHLQR]QDþHYDQMH
Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology,
general requirements, testing and marking
Heizkessel - Teil 1: Heizkessel mit Gebläsebrenner - Begriffe, Allgemeine
Anforderungen, Prüfung und Kennzeichnung
Chaudières de chauffage - Partie 1 : Chaudières avec brûleurs à air soufflé -
Terminologie, prescriptions générales, essais et marquage
Ta slovenski standard je istoveten z: EN 303-1:2017
ICS:
01.040.91 Gradbeni materiali in gradnja Construction materials and
(Slovarji) building (Vocabularies)
27.060.01 Gorilniki in grelniki vode na Burners and boilers in
splošno general
91.140.10 Sistemi centralnega Central heating systems
ogrevanja
SIST EN 303-1:2017 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 303-1:2017

---------------------- Page: 2 ----------------------

SIST EN 303-1:2017


EN 303-1
EUROPEAN STANDARD

NORME EUROPÉENNE

September 2017
EUROPÄISCHE NORM
ICS 91.140.10 Supersedes EN 15034:2006, EN 303-1:1999
English Version

Heating boilers - Part 1: Heating boilers with forced
draught burners - Terminology, general requirements,
testing and marking
Chaudières de chauffage - Partie 1 : Chaudières avec Heizkessel - Teil 1: Heizkessel mit Gebläsebrennern -
brûleurs à air soufflé - Terminologie, prescriptions Begriffe, Allgemeine Anforderungen, Prüfung und
générales, essais et marquage Kennzeichnung
This European Standard was approved by CEN on 26 June 2017.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 303-1:2017 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions, units and symbols . 7
3.1 Terms and definitions . 7
3.2 Units and symbols . 10
3.2.1 Units . 10
3.2.2 Symbols . 11
4 Requirements . 11
4.1 Construction requirements . 11
4.1.1 General requirements . 11
4.1.2 Specific requirements . 23
4.2 Operational requirements . 25
4.2.1 General . 25
4.2.2 Verification of the nominal condensing output . 25
4.2.3 Formation of condensation . 25
4.2.4 Temperature of combustion products . 25
4.2.5 Surface temperature . 25
4.2.6 Water side resistance of the boiler . 26
4.2.7 Soundness of the boiler . 26
4.2.8 Temperature sensing control type TR and temperature sensing control type STB . 26
4.3 Electrical equipment . 26
4.3.1 Electrical safety . 26
4.3.2 Electromagnetic compatibility . 27
5 Tests . 27
5.1 General . 27
5.2 Boilers of steel or non-ferrous metal . 27
5.2.1 Tests to be carried out before production . 27
5.2.2 Factory production control (FPC) for steel boilers . 27
5.3 Boilers of cast iron or non-ferrous metals . 28
5.3.1 Test to be carried out before production . 28
5.3.2 Test during production . 28
5.4 Test for gas soundness . 29
5.5 Water side resistance measurement . 29
5.5.1 General . 29
5.5.2 Test rig for the establishment of the water side resistance . 29
5.6 Additional tests for low temperatures boilers . 31
5.6.1 Additional tests by using of corrosion resistant coatings . 31
5.6.2 Additional tests for oil-fired low temperatures boilers . 31
6 Marking . 31
6.1 Information on the boiler data plate . 31
6.2 Requirements of the data plate . 31
7 Technical documentation, scope of supply . 31
7.1 General . 31
2

---------------------- Page: 4 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
7.2 Technical information (product fiche) and installation instructions . 31
7.3 Operating instructions . 33
7.4 Label . 33
Annex A (informative) Conformity evaluation . 34
Annex ZA (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) No [813/2013] aimed to be covered . 35
Annex ZB (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) No [811/2013] aimed to be covered . 36
Bibliography . 37

3

---------------------- Page: 5 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
European foreword
This document (EN 303-1:2017) has been prepared by Technical Committee CEN/TC 57 “Central
heating boilers”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by March 2018, and conflicting national standards shall
be withdrawn at the latest by March 2018.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate M/534 and M/535 given to CEN by the European
Commission and the European Free Trade Association, and supports essential requirements of
EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA and Annex ZB, which are integral parts
of this document.
This document supersedes EN 303-1:1999 and EN 15034:2006.
The following essential changes have been made:
a) Construction requirements were adopted from EN 15034;
b) Terminology of EU-Regulations 811/2013 and 813/2013 adopted;
c) the document was completely revised technically;
d) the document was completely revised editorially.
The following structure is intended for the European Standards for heating boilers:
— EN 303-1, Heating boilers — Part 1: Heating boilers with forced draught burners — Terminology,
general requirements, testing and marking
— EN 303-2, Heating boilers — Part 2: Heating boilers with forced draught burners — Special
requirements for boilers with atomizing oil burners
— EN 303-3, Heating boilers — Part 3: Gas fired central heating boilers — Assembly comprising a boiler
body and a forced draught burner
— EN 303-4, Heating boilers — Part 4: Heating boilers with forced draught burners — Special
requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum
operating pressure of 3 bar — Terminology, special requirements, testing and marking
— EN 303-5, Heating boilers — Part 5: Heating boilers for solid fuels, hand and automatically fired, with
a nominal heat output of up to 300 kW — Terminology, requirements, testing and marking
— EN 304, Heating boilers — Test code for heating boilers for atomizing oil burners
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
4

---------------------- Page: 6 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
1 Scope
This European Standard applies to boilers used for central heating (heating boilers) with forced
draught burners with a nominal heat output not exceeding 1 000 kW, which are operated either with
negative pressure (natural draught boilers) or with positive pressure (pressurized boiler) in the
combustion chamber, in accordance with the boiler instructions.
This European Standard specifies the necessary terminology, the requirements on the materials and
testing of them, and marking requirements for heating boilers.
Particular requirements for boilers that can be used with open vented systems are contained in
EN 303-4.
The requirements of this standard apply to heating boilers that are tested on an authorized test rig.
Boilers in accordance with this standard are designed for the heating of central heating installations in
which the heat carrier is water, and the maximum allowable operating temperature of which is
restricted to 100 °C. The maximum allowable operating pressure is 8 bar.
For boilers and water heaters (storage or continuous flow heater) this standard only applies to the
parts which are necessarily subject to the operating conditions of the heating boiler (heating part).
This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, boilers
with oil vaporization burners. For these boilers there are further requirements.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 226:1987, Atomizing oil burners - Connecting dimensions between burners and heat generators
EN 303-2:2017, Heating boilers - Part 2: Heating boilers with forced draught burners - Special
requirements for boilers with atomizing oil burners
EN 303-4:1999, Heating boilers - Part 4: Heating boilers with forced draught burners - Special
requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum
operating pressure of 3 bar - Terminology, special requirements, testing and marking
EN 304:2017, Heating boilers - Test code for heating boilers for atomizing oil burners
EN 10025-2:2004, Hot rolled products of structural steels - Part 2: Technical delivery conditions for non-
alloy structural steels
EN 10027-2:2015, Designation systems for steels - Part 2: Numerical system
EN 10028-2:2017, Flat products made of steels for pressure purposes - Part 2: Non-alloy and alloy steels
with specified elevated temperature properties
EN 10028-3:2017, Flat products made of steels for pressure purposes - Part 3: Weldable fine grain steels,
normalized
EN 10029:2010, Hot-rolled steel plates 3 mm thick or above - Tolerances on dimensions and shape
EN 10088-2:2014, Stainless steels - Part 2: Technical delivery conditions for sheet/plate and strip of
corrosion resisting steels for general purposes
5

---------------------- Page: 7 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
EN 10204:2004, Metallic products - Types of inspection documents
EN 13501-1:2007+A1:2009, Fire classification of construction products and building elements - Part 1:
Classification using data from reaction to fire tests
EN 14597:2012, Temperature control devices and temperature limiters for heat generating systems
EN 60335-1:2012, Safety of household and similar electrical appliances — Part 1: General requirements
(IEC 60335-1:2010)
EN 60529:1991, Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989)
EN 60730-1:2011, Automatic electrical controls for household and similar use - Part 1: General
requirements (IEC 60730:2010), modified
EN 60730-2-9:2010, Automatic electrical controls for household and similar use - Part 2-9: Particular
requirements for temperature sensing controls (IEC 60730-2-9:2008), modified
EN 61000-6-2:2005, Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments (IEC 61000-6-2:2005)
EN 61000-6-3:2007, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments (IEC 61000-6-3:2006)
EN 60335-2-102:2016, Household and similar electrical appliances - Safety - Part 2-102: Particular
requirements for gas, oil and solid-fuel burning appliances having electrical connections (IEC 60335-2-
102:2004, modified + A1:2008, modified + A2:2012, modified)
EN ISO 4063:2010, Welding and allied processes - Nomenclature of processes and reference numbers (ISO
4063:2009)
EN ISO 6506 (all parts), Metallic materials - Brinell hardness test
EN ISO 9606-1:2013, Qualification testing of welders - Fusion welding - Part 1: Steels (ISO 9606-1:2012
including Cor 1:2012)
EN ISO 9606-2:2004, Qualification test of welders - Fusion welding - Part 2: Aluminium and aluminium
alloys (ISO 9606-2:2004)
EN ISO/IEC 17025:2005, General requirements for the competence of testing and calibration laboratories
(ISO/IEC 17025:2005)
ISO 7-1:1994, Pipe threads where pressure-tight joints are made on the threads — Part 1: Dimensions,
tolerances and designation
ISO 7-2:2000, Pipe threads where pressure-tight joints are made on the threads — Part 2: Verification by
means of limit gauges
ISO 185:2005, Grey cast irons - Classification
ISO 228-1:2000, Pipe threads where pressure-tight joints are not made on the threads — Part 1:
Dimensions, tolerances and designation
6

---------------------- Page: 8 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
ISO 228-2:1987, Pipe threads where pressure-tight joints are not made on the threads — Part 2:
Verification by means of limit gauges
ISO 857-2:2005, Welding and allied processes — Vocabulary — Part 2: Soldering and brazing processes
and related terms
ISO 2553:2013, Welding and allied processes - Symbolic representation on drawings - Welded joints
ISO 7005-1:2011, Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems
ISO 7005-2:1988, Metallic flanges — Part 2: Cast iron flanges
ISO 7005-3:1988, Metallic flanges — Part 3: Copper alloy and composite flanges
3 Terms and definitions, units and symbols
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1.1
operating pressure
maximum allowable pressure at which the boiler is to be normally operated
Note 1 to entry: The operating pressure is less than the test pressure and the type test pressure.
3.1.2
test pressure
pressure to which all boilers and their parts are subjected during production
3.1.3
type test pressure
pressure to which the pre-production heating boiler(s) and associated parts are subjected before start
of mass production in the manufacturing works
3.1.4
operating temperature
maximum allowable temperature at which the boiler can be operated under normal operating
conditions at the maximum setting of the boiler’s water temperature controller
3.1.5
heat output
P
amount of heat transferred to the heat carrier (water) per unit of time
3.1.6
heat output range
span between the minimal and the maximal heat output over which the boiler meets the requirements
of this standard and over which it can be used, whether it is a range rated or a modulating boiler
3.1.7
nominal heat output
P
N
continuous output in accordance with the requirements of this standard
Note 1 to entry: The nominal heat output is equal to the rated heat output P4 according to EU Regulation
813/2013.
7

---------------------- Page: 9 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
3.1.8
heat input
Q
B
amount of heat in unit time which is supplied to the furnace of the heating boiler by the fuel based on its
net calorific value
3.1.9
boiler efficiency
η
ratio of the heat output (P) to the heat input (Q ) supplied by the fuel
B
P
η=
Q
B
Note 1 to entry: η is equal to η4 according to EU Regulation 813/2013, if P is equal to 100 % P full load .
( )
N
Note 2 to entry: η is equal to η1 according to EU Regulation 813/2013, if P is equal to 0,3 × P .
N
3.1.10
draught
pressure differential between the static air pressure in the place of installation and the static pressure
of the exhaust gases, as measured in the exhaust gas measuring section, which is required for correct
operation of the boiler at nominal output
3.1.11
flue gas resistance
pressure differential between the combustion chamber and the boiler exit
3.1.12
combustion circuit
comprises all components between air inlet and flue gas outlet of boiler which may include the air
supply device, the burner, the combustion chamber, the heat exchanger and the flue gas evacuation
device
3.1.13
soundness of the boiler
limited leakage of the combustion circuit
3.1.14
flue gas temperature
T
dfg
temperature measured at the outlet of the boiler
3.1.15
flue gas loss
quantity of heat per unit time lost at the flue gas exit of the boiler
3.1.16
water side resistance
pressure loss across the boiler measured at the flow and return connections of the boiler, with a volume
flow corresponding to the nominal heat output
8

---------------------- Page: 10 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
3.1.17
condensate
liquid formed from the combustion products during the condensation process
3.1.18
standard boiler
boiler for which the average water temperature can be restricted by design
3.1.19
low temperature boiler
boiler which can work continuously with a water return temperature of 35 ° to 40 °C or lower, possibly
producing condensation in certain circumstances without impairing the boiler’s operation and without
necessity of condensate drainage
Note 1 to entry: No nozzle for condensate drainage intended.
3.1.20
condensing boiler
boiler that, under normal operating conditions and at certain operating water temperatures, partially
condenses the water vapour in the combustion products in order to make use of the latent heat of water
vapour for heating purposes
Note 1 to entry: Always with nozzle for condensate drainage.
3.1.21
electrical power consumption at rated output
el
max
auxiliary electricalpower consumption at full load, expressed in kW
3.1.22
electrical power consumption at part load
el
min
auxiliary electrical power consumption at part load, expressed in kW
3.1.23
Electrical power consumption at standby
P
SB
auxiliary electrical power consumption of a heater in standby mode, expressed in kW
3.1.24
seasonal space heating energy efficiency in active mode
η
son
weighted average of the useful efficiency at rated heat output and the useful efficiency at 30 % of the
rated heat output, expressed in %
[SOURCE: EU Regulation 813/2013 Annex I, Definition 11]
3.1.25
seasonal space heating energy efficiency
η
s
ratio between the space heating demand for a designated heating season, supplied by a heater and the
annual energy consumption required to meet this demand, expressed in %
[SOURCE: EU Regulation 813/2013, §2 (20)]
9

---------------------- Page: 11 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
Note 1 to entry: Weighted average of the useful efficiency at rated heat output and the useful efficiency at 30 %
of the rated heat output, expressed in % corrected with respect to control, the electrical consumption, the standby
heat loss and the pilot consumption if any.
3.1.26
temperature sensing control type TR
thermostat or modulating thermostat used in heat generating systems for controlling the temperature
of liquid or/and gaseous media, which has provisions for setting by the user and which, if equipped
with an electrical output, provides at least type 1B action
Note 1 to entry: See 2.2.4 and 2.2.6 of EN 60730–1:2011 and see 2.2.105 of EN 60730–2-9:2010.
3.1.27
temperature sensing control type STB
safety temperature limiter (thermal cut out, protective control) for heat generating systems which can
only be reset manually or by a tool and which provides at least the actions according to EN 14597
Note 1 to entry: Type 2K action will be considered to be provided if type 2N action is provided.
Note 2 to entry: Actions according to EN 14597: type 2B, type 2K, type 2P and type 2V and optionally any of the
following actions: type 2F and type 2N; the settings of this control are unchangeably fixed or can be fixed with a
tool or a special tool.
3.1.28
nominal condensing output
P
cond
value of useful output, in kW and corresponding to the operation of the boiler in a 50 °C/30 °C water
temperature regime
[SOURCE: EN 15034:2006, definition 3.2]
3.2 Units and symbols
3.2.1 Units
The unit system applied in this standard is the SI system, cf. ISO 80000-1 and others.
The following units and their multiples are used:
Length m (metre);
 mm (millimetre);
Mass kg (kilogram);
Power kW (kilowatt);
Efficiency η (percent);
Other units applied:
Temperature °C (degrees Celsius).
10

---------------------- Page: 12 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
3.2.2 Symbols
Table 1 — Symbols
Symbol Name Unit
P heat output kW
P nominal heat output kW
N
Q heat input kW
B
η boiler efficiency %
T exit flue gas temperature °C
dfg
el electrical power consumption at rated output kW
max
el electrical power consumption at part load kW
min
P electrical power consumption at standby kW
SB
η seasonal space heating energy efficiency in %
son
active mode
η seasonal space heating energy efficiency %
s
P nominal condensing output kW
cond
4 Requirements
4.1 Construction requirements
4.1.1 General requirements
4.1.1.1 Introduction
Boilers shall be fire-resistant and safe to operate. They shall be made of non-combustible materials and
shall be resistant to deformation and shall be such that:
— they can withstand the stresses arising during normal operation;
— the burner and the boiler cannot become heated to create a hazard;
— dangerous accumulations of combustible gases (fuels mixed with air) in the combustion chamber
and in the flues are prevented; and
— gases cannot leak from the boiler in dangerous quantities.
Combustible materials are allowable for:
— components of accessories, e.g. burner covers, if the parts are fitted outside of the boiler;
— internal components of controls and safety equipment;
— operating handles;
— electrical equipment;
— thermal insulation (see 4.1.1.6.9); all materials containing asbestos are forbidden.
11

---------------------- Page: 13 ----------------------

SIST EN 303-1:2017
EN 303-1:2017 (E)
Component parts of covers, operating, control and safety devices and electrical accessories shall be
arranged in such a way that their surface temperatures, under steady-state conditions, do not exceed
those specified either by the technical documentation or in the component part standard.
The materials for the parts subject to pressure shall be in accordance with generally accepted technical
requirements. They shall be suitable for the purpose and treatment intended. The mechanical and
physical properties as well as the chemical composition of the materials shall be guaranteed by the
relevant material producer/supplier.
All parts of the heating boiler likely to come into contact with
...

SLOVENSKI STANDARD
oSIST prEN 303-1:2016
01-julij-2016
.RWOL]DJUHWMHGHO.RWOL]YHQWLODWRUVNLPLJRULOQLNL7HUPLQRORJLMDVSORãQH
]DKWHYHSUHVNXãDQMHLQR]QDþHYDQMH
Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology,
general requirements, testing and marking
Heizkessel - Teil 1: Heizkessel mit Gebläsebrenner - Begriffe, Allgemeine
Anforderungen, Prüfung und Kennzeichnung
Chaudières de chauffage - Partie 1 : Chaudières avec brûleurs à air soufflé -
Terminologie, prescriptions générales, essais et marquage
Ta slovenski standard je istoveten z: prEN 303-1
ICS:
01.040.91 Gradbeni materiali in gradnja Construction materials and
(Slovarji) building (Vocabularies)
27.060.01 Gorilniki in grelniki vode na Burners and boilers in
splošno general
91.140.10 Sistemi centralnega Central heating systems
ogrevanja
oSIST prEN 303-1:2016 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 303-1:2016

---------------------- Page: 2 ----------------------
oSIST prEN 303-1:2016


DRAFT
EUROPEAN STANDARD
prEN 303-1
NORME EUROPÉENNE

EUROPÄISCHE NORM

April 2016
ICS 01.040.91; 91.140.10 Will supersede EN 303-1:1999
English Version

Heating boilers - Part 1: Heating boilers with forced
draught burners - Terminology, general requirements,
testing and marking
Chaudières de chauffage - Partie 1 : Chaudières avec Heizkessel - Teil 1: Heizkessel mit Gebläsebrenner -
brûleurs à air soufflé - Terminologie, prescriptions Begriffe, Allgemeine Anforderungen, Prüfung und
générales, essais et marquage Kennzeichnung
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 57.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 303-1:2016 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 7
4 Requirements . 10
4.1 Construction requirements . 10
4.1.1 General requirements . 10
4.1.2 Specific requirements . 22
4.2 Operational requirements . 23
4.2.1 General . 23
4.2.2 Verification of the nominal condensing output . 23
4.2.3 Formation of condensation . 23
4.2.4 Temperature of combustion products . 23
4.2.5 Surface temperature . 24
4.2.6 Water side resistance of the boiler . 24
4.2.7 Soundness of the boiler . 24
4.2.8 Temperature sensing control type TR and temperature sensing control type STB . 24
4.3 Electrical equipment . 25
4.3.1 Electrical safety . 25
4.3.2 Electromagnetic compatibility . 25
5 Tests . 25
5.1 General . 25
5.2 Boilers of mild steel or non-ferrous metal . 26
5.2.1 Tests to be carried out before production . 26
5.2.2 Factory production control (FPC) for mild steel boilers . 26
5.3 Boilers of cast iron or non-ferrous metals . 26
5.3.1 Test to be carried out before production . 26
5.3.2 Test during production . 26
5.4 Test for gas side soundness . 27
5.5 Waterside resistance measurement . 28
5.5.1 General . 28
5.5.2 Test rig for the establishment of the waterside resistance . 28
5.6 Additional tests for low-temperatures boilers . 30
5.6.1 Additional tests by using of corrosion resistant coatings . 30
5.6.2 Additional tests for oil-fired low-temperatures boilers . 30
6 Marking . 30
6.1 Boiler data plate - Information on the data plate . 30
6.2 Requirements of the data plate . 30
7 Technical documentation, scope of supply . 30
7.1 General . 30
7.2 Technical information (product fiche) and installation instructions . 30
7.3 Operating instructions . 32
7.4 Label . 32
Annex A (informative) Conformity evaluation . 33
2

---------------------- Page: 4 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
Annex ZA (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) No [813/2013] aimed to be covered . 34
Annex ZB (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) No [811/2013] aimed to be covered . 35
Bibliography . 36

3

---------------------- Page: 5 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
European foreword
This document (prEN 303-1:2016) has been prepared by Technical Committee CEN/TC 57 “Central
heating boilers”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
The following structure is intended for the European standards for heating boilers:
EN 303-1, Heating boilers — Part 1: Heating boilers with forced draught burners — Terminology, general
requirements, testing and marking
EN 303-2, Heating boilers — Part 2: Heating boilers with forced draught burners — Special requirements
for boilers with atomizing oil burners
EN 303-3, Heating boilers — Part 3: Gas fired central heating boilers — Assembly comprising a boiler
body and a forced draught burner
EN 303-4, Heating boilers — Part 4: Heating boilers with forced draught burners — Special requirements
for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of
3 bar — Terminology, special requirements, testing and marking
EN 303-5, Heating boilers — Part 5: Heating boilers for solid fuels, hand and automatically fired, with a
nominal heat output of up to 300 kW — Terminology, requirements, testing and marking
EN 304, Heating boilers — Test code for heating boilers for atomizing oil burners
Concerning the required extension of the heat output from 300 kW up to 1 000 kW the following
essential changes were agreed:
a) Construction requirements were adopted from EN 15034;
b) Terminology of EU-Regulations 811/2013 and 813/2013 adopted;
c) the document was completely revised technically;
d) the document was completely revised editorially.
WARNING — Other requirements and other EU Directives may be applicable to the products falling
within the scope of this European Standard.
This document has been prepared under a standardization request M/535 and M/534 given to CEN by
the European Commission and the European Free Trade Association, and supports essential
requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA and Annex ZB, which are integral parts
of this document.
4

---------------------- Page: 6 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
1 Scope
This European Standard applies to boilers used for central heating (heating boilers) with forced
draught burners with a nominal heat output not exceeding 1 000 kW, which are operated either with
negative pressure (natural draught boilers) or with positive pressure (pressurized boiler) in the
combustion chamber, in accordance with the boiler manufacturer’s instruction.
This standard specifies the necessary terminology, the requirements on the materials and testing of
them, and marking requirements for heating boilers.
Particular requirements for boilers that can be used with open vented systems are contained in
EN 303-4.
The requirements of this standard apply to heating boilers that are tested on an authorized test rig.
Boilers in accordance with this standard are designed for the heating of central heating installations in
which the heat carrier is water, and the maximum allowable operating temperature of which is
restricted to 100 °C. The maximum allowable operating pressure is 8 bar.
For boilers (storage or continuous flow heater) this standard only applies to the parts of the water
heater that are necessarily subject to the operating conditions of the heating boiler (heating part).
This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, boilers and
boilers with oil vaporization burners. For these boilers there are further requirements.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 226, Atomizing oil burners - Connecting dimensions between burners and heat generators
prEN 303-2:2016, Heating boilers — Part 2: Heating boilers with forced draught burners — Special
requirements for boilers with atomizing oil burners
EN 303-4, Heating boilers - Part 4: Heating boilers with forced draught burners - Special requirements for
boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3
bar - Terminology, special requirements, testing and marking
prEN 304:2016, Heating boilers — Test code for heating boilers for atomizing oil burners
EN 10025-2, Hot rolled products of structural steels - Part 2: Technical delivery conditions for non-alloy
structural steels
EN 10027-2, Designation systems for steels - Part 2: Numerical system
EN 10028-2:2009, Flat products made of steels for pressure purposes - Part 2: Non-alloy and alloy steels
with specified elevated temperature properties
EN 10028-3:2009, Flat products made of steels for pressure purposes - Part 3: Weldable fine grain steels,
normalized
EN 10029, Hot-rolled steel plates 3 mm thick or above - Tolerances on dimensions and shape
EN 10088-2:2014, Stainless steels - Part 2: Technical delivery conditions for sheet/plate and strip of
corrosion resisting steels for general purposes
5

---------------------- Page: 7 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
EN 10204:2004, Metallic products — Types of inspection documents
EN 13501-1, Fire classification of construction products and building elements - Part 1: Classification
using data from reaction to fire tests
EN 14597, Temperature control devices and temperature limiters for heat generating systems
EN 60335-1, Safety of household and similar electrical appliances — Part 1: General requirements (IEC
60335-1)
EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 60730-1:2011, Automatic electrical controls for household and similar use - Part 1: General
requirements (IEC 60730-1:2010)
EN 60730-2-9:2010, Automatic electrical controls for household and similar use — Part 2: Particular
requirements for temperature sensing controls (IEC 60730-2-9:2008)
EN 61000-6-2, Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments (IEC 61000-6-2)
EN 61000-6-3, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for
residential, commercial and light-industrial environments (IEC 61000-6-3)
EN ISO 4063, Welding and allied processes - Nomenclature of processes and reference numbers (ISO 4063)
EN ISO 6506, all parts, Metallic materials - Brinell hardness test
EN ISO 9606-1, Qualification testing of welders - Fusion welding - Part 1: Steels (ISO 9606-1)
EN ISO 9606-2, Qualification test of welders - Fusion welding - Part 2: Aluminium and aluminium alloys
(ISO 9606-2)
EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
(ISO/IEC 17025)
ISO 7-1, Pipe threads where pressure-tight joints are made on the threads — Part 1: Dimensions,
tolerances and designation
ISO 7-2, Pipe threads where pressure-tight joints are made on the threads — Part 2: Verification by means
of limit gauges
ISO 185, Grey cast irons — Classification
ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions,
tolerances and designation
ISO 228-2, Pipe threads where pressure-tight joints are not made on the threads — Part 2: Verification by
means of limit gauges
ISO 857, Welding, brazing and soldering processes — Vocabulary
ISO 2553, Welding and allied processes — Symbolic representation on drawings — Welded joints
6

---------------------- Page: 8 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
ISO 7005-1, Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems
ISO 7005-2, Metallic flanges — Part 2: Cast iron flanges
ISO 7005-3, Metallic flanges — Part 3: Copper alloy and composite flanges
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
operating pressure
maximum allowable pressure at which the boiler is to be normally operated
Note 1 to entry: The operating pressure is less than the test pressure and the type test pressure.
3.2
test pressure
pressure to which all boilers and their parts are subjected during production in the works of the
manufacturer or during setting up by the installer
3.3
type test pressure
pressure to which the pre-production heating boiler(s) and associated parts are subjected before start
of mass production in the manufacturing works
3.4
operating temperature
maximum allowable temperature at which the boiler can be operated under normal operating
conditions at the maximum setting of the boiler’s water temperature controller
3.5
heat output P
heat output range
amount of heat transferred to the heat carrier (water) per unit of time
Note 1 to entry: The heat output range is the span of output below the nominal heat output specified by the
manufacturer over which the boiler meets the requirements of this standard and over which it can be used.
3.6
nominal heat output
P
N
continuous output specified by the manufacturer in accordance with the requirements of this standard.
It is the maximum useful quantity of heat transferred to the heat carrier per hour
Note 1 to entry: the nominal heat output is equal to the rated heat output according to ErP (P )
4
3.7
heat input
Q
B
amount of heat in unit time which is supplied to the furnace of the heating boiler by the fuel based on its
net calorific value
7

---------------------- Page: 9 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
3.8
boiler efficiency
η
ratio of the heat output (P) to the heat input (Q ) supplied by the fuel
B
P
η=
Q
B
full load
Note 1 to entry: η is equal to η according to ErP, if P is equal to P
4
N
100 %

Note 2 to entry: η is equal to η according to ErP, if P is equal to 0,3 ×P
1
N
3.9
draught
pressure differential between the static air pressure in the place of installation and the static pressure
of the exhaust gases, as measured in the exhaust gas measuring section, which is required for correct
operation of the boiler at nominal output
3.10
flue gas side resistance
pressure differential between the combustion chamber and the boiler exit
3.11
combustion circuit
comprises the combustion chamber, the heat exchanger, the air supply circuit and the combustion
product circuit up to the flue exit
3.12
soundness of combustion circuit
soundness of the combustion circuit through which the exhaust gases flow
3.13
exit flue temperature
t
A
temperature measured at the flue exit of the boiler
3.14
flue gas loss
quantity of heat per unit time lost at the flue gas exit of the boiler
3.15
standby loss
q
B
quantity of heat which is necessary to maintain the boiler at a given temperature when no heat output
is used. It is stated as (P in relation to the heat input P )
stby B
3.16
water side resistance
pressure loss across the boiler measured at the flow and return connections of the boiler, with a volume
flow corresponding to the nominal heat output
8

---------------------- Page: 10 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
3.17
condensate
liquid formed from the combustion products during the condensation process
3.18
standard boiler
boiler for which the average water temperature can be restricted by design
3.19
low temperature boiler
LT
boiler which can work continuously with a water return temperature of 35 ° to 40 °C or lower, possibly
producing condensation in certain circumstances without impairing the boiler’s operation and without
necessity of condensate drainage (no nozzle for condensate drainage foreseen)
3.20
condensing boiler
boiler that, under normal operating conditions and at certain operating water temperatures, partially
condenses the water vapour in the combustion products in order to make use of the latent heat of water
vapour for heating purposes (always with nozzle for condensate drainage)
3.21
electrical consumption at rated output
el
max
auxiliary electricity consumption at full load, expressed in kW
3.22
electrical consumption at part load
el
min
auxiliary electricity consumption at part load, expressed in kW
3.23
electrical consumption at standby
P
SB
standby mode power consumption’ (P ) means the power consumption of a heater in standby mode,
SB
expressed in kW
3.24
seasonal space heating energy efficiency in active mode
η,
son
weighted average of the useful efficiency at rated heat output and the useful efficiency at 30 % of the
rated heat output, expressed in % (active mode)
[SOURCE: EU Regulation 813/2013 Annex I, Definition 11]
3.25
seasonal space heating energy efficiency
η,
s
weighted average of the useful efficiency at rated heat output and the useful efficiency at 30 % of the
rated heat output, expressed in %
[SOURCE: EU Regulation 813/2013, §2 (20)]
9

---------------------- Page: 11 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
3.26
temperature sensing control type TR
thermostat or modulating thermostat used in heat generating systems for controlling the temperature
of liquid or/and gaseous media, which has provisions for setting by the user and which, if equipped
with an electrical output, provides at least type 1B action
Note 1 to entry: See 2.2.4 and 2.2.6 of EN 60730–1:2011 and see 2.2.105 of EN 60730–2-9:2010.
Note 2 to entry: In the following this device is designated by the device code TR.
3.27
temperature sensing control type STB
safety temperature limiter (thermal cut out, protective control) for heat generating systems which can
only be reset manually or by a tool and which provides at least the following actions: type 2B, type 2K,
type 2P and type 2V and optionally any of the following actions: type 2F and type 2N; the settings of this
control are unchangeably fixed or can be fixed with a tool or a special tool
Note 1 to entry: Type 2K action will be considered to be provided if type 2N action is provided.
3.28
nominal condensing output
P
value of useful output declared by the manufacturer, in kW and corresponding to the operation of the
boiler in a 50 °C/30 °C water temperature regime
[SOURCE: EN 15034, Definition 3.2]
4 Requirements
4.1 Construction requirements
4.1.1 General requirements
4.1.1.1 Introduction
Boilers shall be fire-resistant and safe to operate. They shall be made of non-combustible materials and
shall be resistant to deformation and shall be such that:
— they can withstand the stresses arising during normal operation;
— the burner and the boiler cannot become heated to create a hazard;
— dangerous accumulations of combustible gases (fuels mixed with air) in the combustion chamber
and in the flues are prevented and
— gases cannot leak from the boiler in dangerous quantities.
Combustible materials are allowable for
— components of accessories e.g. burner covers, if the parts are fitted outside of the boiler;
— internal components of controls and safety equipment;
— operating handles;
— electrical equipment;
10

---------------------- Page: 12 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
— thermal insulation (see 4.1.1.6.9); all materials containing asbestos are forbidden.
Component parts of covers, operating, control and safety devices and electrical accessories shall be
arranged in such a way that their surface temperatures, under steady-state conditions, do not exceed
those specified either by the manufacturer or in the component part standard.
The materials for the parts subject to pressure shall be in accordance with generally accepted technical
requirements. They shall be suitable for the purpose and treatment intended. The mechanical and
physical properties as well as the chemical composition of the materials shall be guaranteed by the
relevant material producer/supplier.
All parts of the heating boiler likely to come into contact with condensation in condensing or low
temperature boilers shall be constructed of sufficiently corrosion resistant materials or materials
protected by a suitable coating, in order to ensure a reasonable life for a boiler that is installed, used
and maintained in accordance with the manufacturer's instructions. Fuel quality requirements shall be
declared by the manufacturer.
Surfaces in contact with condensate shall be designed to prevent condensate retention.
4.1.1.2 Drawings
The following shall be specified in the boiler drawings or in the relevant documents:
— the specified materials;
— the welding process, the weld type (generally the symbol for the weld type is sufficient) and the
welding fillers;
— the maximum allowable operating temperature in °C;
— the maximum allowable operating pressure in bar;
— the test pressure in bar;
— the nominal heat output or the heat output range for every boiler size in kW.
4.1.1.3 Factory production control (FPC)
4.1.1.3.1 General
The necessary tests according to the specification of the boiler shall be carried out by qualified
personnel and equipment during the factory production control of the boiler.
4.1.1.3.2 Boiler for steel and other non ferrous material
No leakage or significant permanent deformation shall occur during the test of “Factory production
control (FPC) for mild steel boilers” (5.2.2).
4.1.1.3.3 Boiler for cast material
For cast iron parts subject to pressure the following tests shall be carried out using separately cast test
pieces for each cast:
1) tensile test in accordance with ISO 185, Type A; the values given in Table 4 are to be confirmed by
the tensile test;
2) chemical analysis (C, Si, Mn, P, S);
3) Brinell hardness test in accordance with EN ISO 6506- series;
11

---------------------- Page: 13 ----------------------
oSIST prEN 303-1:2016
prEN 303-1:2016 (E)
4) Izod impact (for graphite iron).
The results of the tests shall either be recorded in registers countersigned by the works tester
responsible, or works certificates in accordance with EN 10204 shall be drawn up. Works certificates
and registers shall be kept for at least five years by the manufacturer and shall be accessible for
examination.
The repair of parts subject to pressure by welding is not permissible.
4.1.1.4 Heating boilers of steel and of non ferrous materials
4.1.1.4.1 Execution of welding work
Boiler manufacturers who carry out welding work shall meet the following requirements of
EN ISO 9606-1 and EN ISO 9606-2:
— only welders who are qualified in the welding of the materials to be processed may be used;
— equipment shall be available to allow defect free welding to
...

Questions, Comments and Discussion