Terminations for steel wire ropes - Safety - Part 3: Ferrules and ferrule-securing

This document deals with the requirements for the ferrule-securing of eyes and endless loops.
It also deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops.
This document applies to the ferrule-securing of eye terminations formed either by a Flemish eye or turn-back eye and covers ferrules made of non alloy carbon steel and aluminium.
This document applies to slings and assemblies using steel wire ropes for general lifting applications up to and including 60 mm diameter conforming to EN 12385-4, lift ropes conforming to EN 12385-5 and spiral strand ropes conforming to EN 12385-10. It is approved for use on rope grades up to 1960. For use on rope grades higher than 1960, the designer/ manufacturer must satisfy the testing requirements of this document.
Type testing of ferrule-secured systems and manufacturing quality control requirements are also specified.
This document deals with all significant hazards, hazardous situations, and events relevant to this particular steel wire rope termination when used as intended and under conditions of use which are foreseeable by the manufacturer.
This document applies to terminations of steel wire ropes with ferrules and ferrule-securing which are manufactured after the date of this publication.
NOTE   One design of ferrule-secured turn-back eye termination using an oval aluminium ferule which satisfies the requirements of this document is given for information in Annex A.

Endverbindungen für Drahtseile aus Stahldraht - Sicherheit - Teil 3: Pressklemmen und Verpressen

Dieses Dokument behandelt die Anforderungen für das Verpressen von Seilschlaufen und Endlosseilen.
Es behandelt auch die Anforderungen an die Pressklemmen für das Verpressen von Seilschlaufen und Endlosseilen.
Dieses Dokument gilt für das Verpressen von Flämischen Augen und rückgebogenen Seilschlaufen und behandelt Pressklemmen aus unlegiertem Kohlenstoffstahl und Aluminium.
Dieses Dokument gilt für Anschlagseile und Stahldrahtseile mit verpresster Seil-Endverbindung für allgemeine Hebezwecke bis zu einem Durchmesser von 60 mm nach EN 12385-4, aus Aufzugsseilen nach EN 12385-5 und Spiralseilen nach EN 12385-10. Es ist für die Verwendung mit Seilfestigkeitsklassen von bis zu 1960 zugelassen. Für die Verwendung mit Seilfestigkeitsklassen über 1960 muss der Entwickler/Hersteller die Prüfanforderungen in diesem Dokument erfüllen.
Die Baumusterprüfung des Pressklemmensystems und die Anforderungen an die Qualitätskontrolle bei der Herstellung sind ebenfalls festgelegt.
Dieses Dokument behandelt alle wesentlichen Gefährdungen, gefährlichen Situationen und Ereignisse, die für diese besondere Seil-Endverbindung von Bedeutung sind, wenn sie wie vorgesehen und unter Bedingungen, wie sie vom Hersteller als vorhersehbar gelten können, angewendet werden.
Dieses Dokument gilt für Seil-Endverbindungen mit Pressklemmen und für Verpressungen, die nach dem Erscheinungsdatum hergestellt wurden.
ANMERKUNG   Eine Ausführung von verpressten rückgebogenen Seilschlaufen, bei der eine ovale Aluminiumpressklemme verwendet wird und die die Anforderungen dieses Dokuments erfüllt, ist in Anhang A zur Information angegeben.

Terminaisons pour câbles en acier - Sécurité - Partie 3 : Manchons et boucles manchonnées

Le présent document traite des prescriptions relatives au manchonnage des boucles manchonnées et des œillets épissés.
Il traite également des prescriptions relatives aux manchons utilisés pour le manchonnage des boucles et des œillets épissés.
Le présent document s'applique au manchonnage des terminaisons à boucle formées d'un œil flamand ou d'une boucle manchonnée à brins parallèles et traite des manchons constitués d'acier au carbone non allié et d'aluminium.
Le présent document s'applique aux élingues et assemblages qui utilisent des câbles en acier pour des applications de levage générales jusqu'à et y compris un diamètre de 60 mm conformément à l'EN 12385-4, des câbles pour ascenseurs conformément à l'EN 12385-5 et des câbles spiraloïdaux conformément à l'EN 12385-10. Son utilisation est approuvée pour une utilisation avec des câbles jusqu’à la classe 1960. Pour une utilisation sur des câbles de qualité supérieure à la classe 1960, le concepteur/fabricant doit satisfaire aux exigences d'essai du présent document.
Des essais de type des systèmes manchonnés et les prescriptions relatives au contrôle de qualité de fabrication sont également spécifiés.
Le présent document traite de tous les phénomènes dangereux et de toutes les situations et événements dangereux significatifs correspondant à cette terminaison de câble en acier particulière lorsqu'elle est utilisée tel que prévu et dans les conditions d'utilisation prévisibles par le fabricant.
Le présent document s'applique aux terminaisons de câbles en acier à boucles manchonnées fabriquées après sa date de publication.
NOTE   Un modèle de terminaison à boucle manchonnée à brins parallèles utilisant un manchon ovale en aluminium satisfaisant aux prescriptions du présent document est donné pour information dans l'Annexe A.

Zaključki jeklenih žičnih vrvi - Varnost - 3. del: Stisne puše in stiskanje

Ta dokument obravnava zahteve za zanke in neskončne zanke s stisno pušo.
Prav tako obravnava zahteve za stisne puše za zanke in neskončne zanke.
Ta dokument se uporablja za zaključke zank s stisnjeno pušo, izvedenih z neprepleteno zanko (Flemish eye) ali povratno zanko (turn-back eye) in zajema puše iz nelegiranega ogljikovega jekla in aluminija.
Ta dokument se uporablja za zanke in sestave, ki uporabljajo jeklene žične vrvi za splošno dvigovanje s premerom do vključno 60 mm, ki so skladne s standardom EN 12385-4, dvižne vrvi, ki so skladne s standardom EN 12385-5 in spiralne pramenaste vrvi, ki so skladne s standardom EN 12385-10. Odobren je za uporabo pri razredih vrvi do razreda 1960. Za uporabo višjih razredov (nad 1960) vrvi mora projektant/proizvajalec izpolniti preskusne zahteve iz tega dokumenta.
Tipsko preskušanje sistemov s stisnjeno pušo in zahteve za nadzor kakovosti izdelave so prav tako določeni.
Ta dokument obravnava vsa večja tveganja, nevarne situacije in nevarne dogodke v zvezi z zaključkom jeklene žičnate vrvi, kadar se uporabljajo v skladu s predvidenim namenom in pod pričakovanimi pogoji uporabe, ki jih določa proizvajalec.
Ta dokument se uporablja za zaključke jeklenih žičnih vrvi s stisnimi pušami, ki so bili izdelani po objavi tega dokumenta.
OPOMBA:   Ena od zasnov zaključka s povratno stisno pušo iz ovalnega aluminija, ki izpolnjuje zahteve iz tega dokumenta, je informativno podana v dodatku A.

General Information

Status
Published
Public Enquiry End Date
29-Apr-2022
Publication Date
04-Apr-2023
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
21-Dec-2022
Due Date
25-Feb-2023
Completion Date
05-Apr-2023

Relations

Buy Standard

Standard
EN 13411-3:2023
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 13411-3:2022
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 13411-3:2023
01-maj-2023
Nadomešča:
SIST EN 13411-3:2004+A1:2008
Zaključki jeklenih žičnih vrvi - Varnost - 3. del: Stisne puše in stiskanje
Terminations for steel wire ropes - Safety - Part 3: Ferrules and ferrule-securing
Endverbindungen für Drahtseile aus Stahldraht - Sicherheit - Teil 3: Pressklemmen und
Verpressen
Terminaisons pour câbles en acier - Sécurité - Partie 3 : Manchons et boucles
manchonnées
Ta slovenski standard je istoveten z: EN 13411-3:2022
ICS:
53.020.30 Pribor za dvigalno opremo Accessories for lifting
equipment
77.140.99 Drugi železni in jekleni izdelki Other iron and steel products
SIST EN 13411-3:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 13411-3:2023

---------------------- Page: 2 ----------------------
SIST EN 13411-3:2023


EN 13411-3
EUROPEAN STANDARD

NORME EUROPÉENNE

December 2022
EUROPÄISCHE NORM
ICS 21.060.70; 53.020.30 Supersedes EN 13411-3:2004+A1:2008
English Version

Terminations for steel wire ropes - Safety - Part 3: Ferrules
and ferrule-securing
Terminaisons pour câbles en acier - Sécurité - Partie 3 : Endverbindungen für Drahtseile aus Stahldraht -
Manchons et boucles manchonnées Sicherheit - Teil 3: Pressklemmen und Verpressen
This European Standard was approved by CEN on 4 December 2022.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13411-3:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 List of hazards . 7
5 Safety requirements and/or measures . 8
5.1 Ferrule-secured system . 8
5.1.1 General . 8
5.1.2 Type testing . 9
5.1.3 Instructions to be provided by the ferrule-secured system designer .10
5.2 Ferrules .10
5.2.1 Material .10
5.2.2 Dimensions .10
5.2.3 Manufacture and quality control of ferrule .11
5.2.4 Certificate .11
5.2.5 Marking .11
5.3 Ferrule-securing .11
5.3.1 General .11
5.3.2 Matching of ferrule to wire rope .11
5.3.3 Forming the eye .12
5.3.4 Pressing the ferrule .14
5.3.5 Quality control after pressing of the ferrule .14
6 Verification of the safety requirements and/or measures .14
6.1 Qualification of personnel .14
6.2 Tensile type test (FSET system designer).14
6.3 Fatigue type test (FSET system designer) .15
6.4 Fatigue type test of Flemish eye ferrule-secured termination of crane hoist rope
(FSET system designer).15
6.5 Ferrule dimensions before pressing (Ferrule manufacturer) .15
6.6 Manufacture and quality control of ferrule (Ferrule manufacturer) .15
6.7 Ferrules (FSET or ferrule-secured endless loop manufacturer) .15
6.8 Matching of ferrule to wire rope (FSET or ferrule-secured endless loop
manufacturer) .15
6.9 Forming the eye (FSET or ferrule-secured endless loop manufacturer) .15
6.10 Pressing the ferrule (FSET or ferrule-secured endless loop manufacturer) .15
6.11 Quality control after pressing the ferrule(s) (FSET or ferrule-secured endless loop
manufacturer) .15
7 Information for use .16
7.1 Marking .16
7.2 Certificate .16
2

---------------------- Page: 4 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
Annex A (informative) Specification for one design of turn-back eye ferrule-secured
termination . 17
A.1 General . 17
A.2 Types of terminations . 17
A.3 Ropes for this design of ferrule . 18
A.3.1 General . 18
A.3.2 Rope types . 18
A.3.3 Metallic cross-sectional area factor . 19
A.3.4 Rope grade . 19
A.3.5 Types of rope lay . 19
A.4 Tubing . 19
A.4.1 General . 19
A.4.2 Material . 19
A.4.3 Straightness . 19
A.4.4 Wall thickness . 20
A.5 Identification and dimensions of ferrules (unpressed) . 21
A.6 Matching wire rope to ferrule . 23
A.7 Making the eye termination . 26
A.7.1 Positioning of ferrule (Types A and B) . 26
A.7.2 Pressing the ferrule . 27
A.7.3 Ferrules after pressing . 27
A.8 Information for use . 29
A.8.1 Identification marking . 29
A.8.2 Temperature limits . 29
Bibliography . 30

3

---------------------- Page: 5 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
European foreword
This document (EN 13411-3:2022) has been prepared by Technical Committee CEN/TC 168 “Chains,
ropes, webbing, slings and accessories - Safety”, the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by June 2023, and conflicting national standards shall be
withdrawn at the latest by June 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 13411-3:2004+A1:2008.
This document has been modified by the removal of Annexes ZA and ZB in accordance with the standard
being de-harmonized.
Annex A is informative.
EN 13411, Terminations for steel wire ropes — Safety consists of the following parts:
— Part 1: Thimbles for steel wire rope slings;
— Part 2: Splicing of eyes for wire rope slings;
— Part 4: Metal and resin socketing;
— Part 5: U-bolt wire rope grips;
— Part 6: Asymmetric wedge socket;
— Part 7: Symmetric wedge socket;
— Part 8: Swage terminals and swaging;
— Part 9: Solid Thimbles.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
4

---------------------- Page: 6 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
Introduction
This document is a Type C standard as stated in EN ISO 12100:2010.
The machinery concerned and the extent to which hazards, hazardous situations and events are covered
are indicated in the scope of this document.
It is understood that type testing of a ferrule-secured eye termination system is the responsibility of the
ferrule-secured eye termination system designer.
It is also understood that the ferrule supplier is responsible for ensuring that the material, design, and
quality of the ferrule is in accordance with the ferrule-secured eye system designer’s specification.
Ferrule-secured eyes manufactured by the ferrule-secured eye termination producer in accordance with
this document are permitted for use as rope terminations in the production of steel wire rope slings. They
are also used as terminations for steel wire rope assemblies for raising, lowering, and supporting loads.
The steel wire rope terminations concerned and the extent to which hazards, hazardous situations and
events are covered are indicated in the scope of this document.
When provisions of this Type C standard are different from those which are stated in Type A or B
standards, the provisions of this Type C standard take precedence over the provisions of the other
standards, for steel wire rope terminations that have been designed and produced according to the
provisions of this Type C standard.
5

---------------------- Page: 7 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
1 Scope
This document deals with the requirements for the ferrule-securing of eyes and endless loops.
It also deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops.
This document applies to the ferrule-securing of eye terminations formed either by a Flemish eye or turn-
back eye and covers ferrules made of non-alloy carbon steel and aluminium.
This document applies to slings and assemblies using steel wire ropes for general lifting applications up
to and including 60 mm diameter conforming to EN 12385-4, lift ropes conforming to EN 12385-5 and
spiral strand ropes conforming to EN 12385-10.
Type testing of ferrule-secured systems and manufacturing quality control requirements are also
specified.
This document deals with all significant hazards, hazardous situations, and events relevant to this
particular steel wire rope termination when used as intended and under conditions of use which are
foreseeable by the manufacturer.
This document applies to terminations of steel wire ropes with ferrules and ferrule-securing which are
manufactured after the date of this publication.
NOTE One design of ferrule-secured turn-back eye termination using an oval aluminium ferule which satisfies
the requirements of this document when securing ropes having rope grades up to and including 1960 is given for
information in Annex A.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 12385-2, Steel wire ropes — Safety — Part 2: Definitions, designation and classification
EN ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk
reduction (ISO 12100:2010)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 12385-2 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
3.1
ferrule-secured eye termination
FSET
eye formed at a rope end secured by means of a ferrule pressed on the rope
3.2
Flemish eye ferrule-secured termination
eye formed at a rope end secured by means of a ferrule pressed on the main body of the rope and the tail
ends of the strands from the Flemish eye
6

---------------------- Page: 8 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
3.3
turn-back eye ferrule-secured termination
eye formed at a rope end secured by means of a ferrule pressed onto the main body of the rope and the
tail end
3.4
ferrule-secured endless loop
loop secured by ferrules pressed on the overlapping rope ends resulting in an endless rope assembly
3.5
competent person
designated person, suitably qualified by knowledge and experience, and with the necessary instruction
to ensure that the required operations are correctly carried out
3.6
ferrule-secured system designer
person or organization that designs the ferrule-secured eye termination or ferrule-secured endless loop
and assumes responsibility for type testing
3.7
ferrule manufacturer
person or organization that manufactures ferrules for a ferrule-secured eye termination or ferrule-
secured endless loop system
3.8
ferrule-secured termination manufacturer
person or organization that manufactures the FSET and/or ferrule secured endless loop in accordance
with the ferrule-secured termination system designer’s instructions
4 List of hazards
This clause contains all the significant hazards, hazardous situations and events, as far as they are dealt
with in this standard, identified by risk assessment as significant for this type of steel wire rope
termination and which require action to eliminate or reduce the risk.
Accidental release of a load due to failure of a FSET puts at risk either directly or indirectly the safety or
health of those persons within the danger zone.
Table 1 contains those hazards that require action to minimize risk identified by risk assessment as being
specific and significant for ferrule-secured eyes and endless loops.
7

---------------------- Page: 9 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
Table 1 — Hazards and associated requirements
Hazards relevant to this standard identified by Relevant clause of this document
reference to EN ISO 12100:2010
Inadequate mechanical strength 5.1.2
5.2
Annex A
Inadequate dimensional tolerances 5.3.2
Annex A
Inadequate information about the selection of 5.1.3
ropes and accessories and their inadequate
5.3
integration into the machine
6.8
7
Inadequate information about abnormal 6
conditions of assembly/testing/use and
7
maintenance
Inadequate information for the selection of ropes Annex A
suitable for the particular application
Exposure to puncture hazard 5.3.4
5.3.5
NOTE For the purposes of this Part of EN 13411, inadequate strength of parts means failure to achieve 90 %
of the minimum breaking force of the rope.

5 Safety requirements and/or measures
5.1 Ferrule-secured system
5.1.1 General
The ferrule-secured system shall comply with the safety requirements and/or protection measures of
this clause.
In addition, the ferrule-secured systems shall be designed according to the principles of EN ISO 12100 for
relevant hazards but not significant, which are not dealt with in this document.
The ferrule-secured system designer shall carry out type testing in accordance with 5.1.2.
The ferrule-secured termination system designer shall provide instructions on how to produce the
ferrule-secured termination and/or the ferrule-secured endless loop.
The instructions shall at least cover those items given in 5.1.3 and be supported with a written declaration
that the system has passed the type testing requirements of 5.1.2.
8

---------------------- Page: 10 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
In the particular case of oval ferrules with tapered ends used in the securing of the turn-back eye or
endless loop where the rope end is contained within the ferrule, the ferrule-secured system designer shall
provide means whereby the position of the rope end before and after pressing can be ascertained. This
shall not include verification by marking the rope. Only the parallel portion of a ferrule shall be
considered load bearing.
5.1.2 Type testing
5.1.2.1 Sampling
Where the ferrule design follows a mathematical progression throughout a given size range, rope
diameter shall be selected for testing to represent the lower and upper quartiles of that range.
Where the ferrule design does not follow a mathematical progression throughout a given size range, each
rope diameter within that range for which the system is designed shall be selected for testing.
For each rope diameter selected as above, the rope grade shall be the highest for which the system is
designed and at least three FSETs or three ferrule secured endless loops, whichever is the case, shall be
tested.
NOTE 1 In the case of the FSET, the number of tests is regarded as two when the test lengths have a FSET at both
ends.
Additionally, sampling shall take into account whether the type of ferrule-secured termination is a turn-
back eye or Flemish eye or whether it is an endless loop, as follows:
a) Turn-back eye ferrule secured-termination
Testing shall be carried out on each of the basic rope types for which the system is designed. For each
basic rope type, testing shall be carried out on ropes having the lowest and highest metallic cross-
sectional area factors for which the system is designed.
NOTE 2 For the purposes of this document there are four basic rope types, namely single layer rope,
rotation-resistant rope, parallel-closed rope, and spiral strand rope, refer to EN 12385-2 for definitions.
b) Flemish-eye ferrule-secured termination
Testing shall be carried out on single layer rope having the lowest and highest metallic cross-
sectional area factors for which the system is designed.
c) Ferule-secured endless loop
Testing shall be carried out on single layer rope having the lowest and highest metallic cross-
sectional factor for which the system is designed.
5.1.2.2 Tensile test
When tested in accordance with 6.2, the FSET shall sustain a force of at least 90 % of the minimum
breaking force of the rope.
NOTE A terminal efficiency of 90 % is equivalent to a termination efficiency factor, K , of 0,9 which is used in
T
the calculation of WLL for slings.
When tested in accordance with 6.2, the ferrule-secured endless loop shall sustain a force of at least 90 %
of twice the minimum breaking force of the rope.
9

---------------------- Page: 11 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
5.1.2.3 Fatigue test
When tested in accordance with 6.3 for 75 000 cycles followed by a tensile test in accordance with 6.2,
the FSET shall sustain a force of at least 80 % of the minimum breaking force of the rope and the endless
loop shall sustain a force of at least 80 % of twice the minimum breaking force of the rope.
Additionally, for Flemish eye ferrule-secured terminations of crane hoist ropes, a further fatigue test shall
be performed on an assembly comprising a solid thimble having a peripheral length equivalent to at least
four rope lay lengths. When tested in accordance with 6.4, the ferrule-secured termination shall
6
withstand a minimum of 1x10 cycles and not exhibit a complete strand fracture.
5.1.3 Instructions to be provided by the ferrule-secured system designer
The ferrule-secured system designer shall provide instructions on at least the following:
a) preparation of the rope end;
b) details of the rope(s) for which the system is designed;
c) matching of the ferrule material and size to the rope diameter and type;
d) positioning of the rope end;
e) procedure for ferrule-securing, i.e. pressing the ferrule;
f) alignment, condition and maintenance of the tooling;
g) procedure for removal of fins;
h) dimensional requirements of the pressed ferrule;
i) marking limitations of the ferrule; and
j) temperature limits of the ferrule secured system.
5.2 Ferrules
5.2.1 Material
The material selected by the ferrule manufacturer shall be non-alloy carbon steel or aluminium and shall
conform to the same specification as that used by the ferrule-secured system designer when satisfying
the type tests.
Non-alloy carbon steel shall be a fully-killed non-ageing normalized steel.
5.2.2 Dimensions
The dimensions of the ferrule shall be in accordance with those used by the ferrule-secured system
designer when satisfying the type tests.
10

---------------------- Page: 12 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
5.2.3 Manufacture and quality control of ferrule
The tube from which ferrules are made shall be free from any cracks, folds and surface defects.
With the exception of steel ferrules for Flemish eyes, ferrules shall be produced to provide a seam-free
hollow product. Extrusion over mandrels with a bridge shall not be used. Electric resistance welding of
steel tubes may only take place for steel ferrules for Flemish eyes and shall be carried out prior to the
tube drawing and normalizing processes.
For each batch of steel ferrules produced from the same cast of steel and heat treatment a sample ferrule
shall be selected and close flattened at ambient temperature, see Figure 1. If the sample fails this test a
further ten (10) or 3 % of the batch of ferrules, whichever is the greater, shall be randomly selected, and
all shall pass the flattening test otherwise the whole batch shall be rejected.

Figure 1 — Close-flattened ferrules
5.2.4 Certificate
The ferrule manufacturer shall supply a certificate stating that the whole batch of ferrules conforms to
the ferrule secured system designer’s specification.
5.2.5 Marking
Each ferrule shall be marked with its size and the ferrule manufacturer’s name or mark except in the case
of ferrules for use with ropes smaller than 8 mm diameter where the marking can be on the package.
5.3 Ferrule-securing
5.3.1 General
The procedure adopted by the manufacturer of the ferrule-secured eye termination or endless loop shall
be in accordance with 5.3.2 to 5.3.5 and the instructions provided by the ferrule-secured system designer.
Ferrule-securing shall be carried out by a competent person trained in ferrule-securing.
5.3.2 Matching of ferrule to wire rope
Determine the rope details from the documentation supplied with the rope, see EN 12385-1 and ensure
that the rope is within the scope of the ferrule-secured system as detailed by the ferrule-secured system
designer. In some cases, it will also be necessary to determine the nominal metallic cross-sectional area
factor of the rope, refer to EN 12385-4, EN 12385-5 and EN 12385-10.
Follow the ferrule-secured system designer’s instructions to select the appropriate ferrule size, taking
into account the nominal or measured diameter of the rope, whichever is applicable.
11

---------------------- Page: 13 ----------------------
SIST EN 13411-3:2023
EN 13411-3:2022 (E)
5.3.3 Forming the eye
5.3.3.1 Flemish eye
The outer strands of the rope shall be divided into two equal groups. The core shall be assigned to one of
these groups. The length of rope divided shall depend on t
...

SLOVENSKI STANDARD
oSIST prEN 13411-3:2022
01-april-2022
Zaključki jeklenih žičnih vrvi - Varnost - 3. del: Stisne puše in stiskanje
Terminations for steel wire ropes - Safety - Part 3: Ferrules and ferrule-securing
Endverbindungen für Drahtseile aus Stahldraht - Sicherheit - Teil 3: Pressklemmen und
Verpressen
Terminaisons pour câbles en acier - Sécurité - Partie 3 : Manchons et boucles
manchonnées
Ta slovenski standard je istoveten z: prEN 13411-3
ICS:
53.020.30 Pribor za dvigalno opremo Accessories for lifting
equipment
77.140.99 Drugi železni in jekleni izdelki Other iron and steel products
oSIST prEN 13411-3:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 13411-3:2022

---------------------- Page: 2 ----------------------
oSIST prEN 13411-3:2022


DRAFT
EUROPEAN STANDARD
prEN 13411-3
NORME EUROPÉENNE

EUROPÄISCHE NORM

February 2022
ICS 21.060.70; 53.020.30 Will supersede EN 13411-3:2004+A1:2008
English Version

Terminations for steel wire ropes - Safety - Part 3: Ferrules
and ferrule-securing
Terminaisons pour câbles en acier - Sécurité - Partie 3 : Endverbindungen für Drahtseile aus Stahldraht -
Manchons et boucles manchonnées Sicherheit - Teil 3: Pressklemmen und Verpressen
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 168.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13411-3:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 List of hazards . 7
5 Safety requirements and/or measures . 8
5.1 Ferrule-secured system . 8
5.1.1 General . 8
5.1.2 Type testing . 9
5.1.3 Instructions to be provided by the ferrule-secured system designer . 10
5.2 Ferrules . 10
5.2.1 Material . 10
5.2.2 Dimensions . 10
5.2.3 Manufacture and quality control of ferrule . 10
5.2.4 Certificate . 11
5.2.5 Marking . 11
5.3 Ferrule-securing . 11
5.3.1 General . 11
5.3.2 Matching of ferrule to wire rope . 11
5.3.3 Forming the eye . 11
5.3.4 Pressing the ferrule . 13
5.3.5 Quality control after pressing of the ferrule . 14
6 Verification of the safety requirements and/or measures . 14
6.1 Qualification of personnel . 14
6.2 Tensile type test (FSET system designer). 14
6.3 Fatigue type test (FSET system designer) . 14
6.4 Fatigue type test of Flemish eye ferrule-secured termination of crane hoist rope (FSET
system designer) . 14
6.5 Ferrule dimensions before pressing (Ferrule manufacturer) . 14
6.6 Manufacture and quality control of ferrule (Ferrule manufacturer) . 14
6.7 Ferrules (FSET or ferrule-secured endless loop manufacturer) . 15
6.8 Matching of ferrule to wire rope (FSET or ferrule-secured endless loop manufacturer) . 15
6.9 Forming the eye (FSET or ferrule-secured endless loop manufacturer) . 15
6.10 Pressing the ferrule (FSET or ferrule-secured endless loop manufacturer) . 15
6.11 Quality control after pressing the ferrule(s) (FSET or ferrule-secured endless loop
manufacturer) . 15
7 Information for use . 15
7.1 Marking . 15
7.2 Certificate . 15
Annex A (informative)  Specification for one design of turn-back eye ferrule-secured termination . 16
A.1 General . 16
A.2 Types of terminations. 16
2

---------------------- Page: 4 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
A.3 Ropes for this design of ferrule . 17
A.3.1 General . 17
A.3.2 Rope types . 17
A.3.3 Metallic cross-sectional area factor . 17
A.3.4 Rope grade . 17
A.3.5 Types of rope lay . 17
A.4 Tubing . 17
A.4.1 General . 17
A.4.2 Material . 17
A.4.3 Straightness . 18
A.4.4 Wall thickness . 18
A.5 Identification and dimensions of ferrules (unpressed) . 19
A.6 Matching wire rope to ferrule . 21
A.7 Making the eye termination . 24
A.7.1 Positioning of ferrule (Types A and B) . 24
A.7.2 Pressing the ferrule . 25
A.7.3 Ferrules after pressing . 25
A.8 Information for use . 27
A.8.1 Identification marks . 27
A.8.2 Temperature limits . 27
Bibliography . 28

3

---------------------- Page: 5 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
European foreword
This document (prEN 13411-3:2022) has been prepared by Technical Committee CEN/TC 168 “Chains,
ropes, webbing, slings and accessories - Safety”, the secretariat of which is held by BSI.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 13411-3:2004+A1:2008.
This document has been modified by the removal of Annexes ZA and ZB in accordance with the standard
being de-harmonized.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association and supports essential requirements of EU Directive(s).
Annex A is informative.
The other parts of EN 13411 are:
Part 1: Thimbles for steel wire rope slings
Part 2: Splicing of eyes for wire rope slings
Part 3: Ferrules and ferrule-securing
Part 4: Metal and resin socketing
Part 5: U-bolt wire rope grips
Part 6: Asymmetric wedge socket
Part 7: Symmetric wedge socket
Part 8: Swage terminals and swaging
Part 9: Solid Thimbles

4

---------------------- Page: 6 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
Introduction
This document is a Type C standard as stated in EN ISO 12100:2010.
The machinery concerned and the extent to which hazards, hazardous situations and events are covered are
indicated in the scope of this document.
It is understood that type testing of a ferrule-secured eye termination system is the responsibility of the
ferrule-secured eye termination system designer.
It is also understood that the ferrule supplier is responsible for ensuring that the material, design, and
quality of the ferrule is in accordance with the ferrule-secured eye system designer’s specification.
Ferrule-secured eyes manufactured by the ferrule-secured eye termination producer in accordance with this
document are permitted for use as rope terminations in the production of steel wire rope slings. They are
also used as terminations for steel wire rope assemblies for raising, lowering, and supporting loads.
The steel wire rope terminations concerned and the extent to which hazards, hazardous situations and
events are covered are indicated in the scope of this document.
When provisions of this type C standard are different from those which are stated in type A or B standards,
the provisions of this type C standard take precedence over the provisions of the other standards, for steel
wire rope terminations that have been designed and produced according to the provisions of this type C
standard.

5

---------------------- Page: 7 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
1 Scope
This document deals with the requirements for the ferrule-securing of eyes and endless loops.
It also deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops.
This document applies to the ferrule-securing of eye terminations formed either by a Flemish eye or turn-
back eye and covers ferrules made of non alloy carbon steel and aluminium.
This document applies to slings and assemblies using steel wire ropes for general lifting applications up to
and including 60 mm diameter conforming to EN 12385-4, lift ropes conforming to EN 12385-5 and spiral
strand ropes conforming to EN 12385-10. It is approved for use on rope grades up to 1960. For use on rope
grades higher than 1960, the designer/ manufacturer must satisfy the testing requirements of this
document.
Type testing of ferrule-secured systems and manufacturing quality control requirements are also specified.
This document deals with all significant hazards, hazardous situations, and events relevant to this particular
steel wire rope termination when used as intended and under conditions of use which are foreseeable by the
manufacturer.
This document applies to terminations of steel wire ropes with ferrules and ferrule-securing which are
manufactured after the date of this publication.
NOTE One design of ferrule-secured turn-back eye termination using an oval aluminium ferule which satisfies the
requirements of this document is given for information in Annex A.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 515:2017, Aluminium and aluminium alloys — Wrought products — Temper designations
EN 12385-1:2002+A1:2008, Steel wire ropes — Safety — Part 1: General requirements
EN 12385-2:2002+A1:2008, Steel wire ropes — Safety — Part 2: Definitions, designation and classification
EN 12385-4:2002+A1:2008, Steel wire ropes — Safety — Part 4: Stranded ropes for general lifting
applications
EN 12385-5:2021, Steel wire ropes — Safety — Part 5: Stranded ropes for lifts
EN 12385-10:2003+A1:2008, Steel wire ropes — Safety — Part 10: Spiral ropes for general structural
applications
EN ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk reduction
(ISO 12100:2010)
6

---------------------- Page: 8 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
3 Terms and definitions
For the purposes of this document, the terms and definitions in EN 12385-2 apply together with the
following:
3.1
ferrule-secured eye termination (FSET)
eye formed at a rope end secured by means of a ferrule pressed on the rope
3.2
Flemish eye ferrule-secured termination
eye formed at a rope end secured by means of a ferrule pressed on the main body of the rope and the tail
ends of the strands from the Flemish eye
3.3
turn-back eye ferrule-secured termination
eye formed at a rope end secured by means of a ferrule pressed onto the main body of the rope and the tail
end
3.4
ferrule-secured endless loop
loop secured by ferrules pressed on the overlapping rope ends resulting in an endless rope assembly
3.5
competent person
designated person, suitably qualified by knowledge and experience, and with the necessary instruction to
ensure that the required operations are correctly carried out
3.6
ferrule-secured system designer
person or organization that designs the ferrule-secured eye termination or ferrule-secured endless loop and
assumes responsibility for type testing
3.7
ferrule manufacturer
person or organization that manufactures ferrules for a ferrule-secured eye termination or ferrule-secured
endless loop system
3.8
ferrule-secured termination manufacturer
person or organization that manufactures the FSET and/or ferrule secured endless loop in accordance with
the ferrule-secured termination system designer’s instructions
4 List of hazards
This clause contains all the significant hazards, hazardous situations and events, as far as they are dealt with
in this standard, identified by risk assessment as significant for this type of steel wire rope termination and
which require action to eliminate or reduce the risk.
Accidental release of a load due to failure of a FSET puts at risk either directly or indirectly the safety or
health of those persons within the danger zone.
Table 1 contains those hazards that require action to minimize risk identified by risk assessment as being
specific and significant for ferrule-secured eyes and endless loops.
7

---------------------- Page: 9 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
Table 1 — Hazards and associated requirements
Hazards relevant to this standard identified by Relevant clause of this standard
reference to EN ISO 12100:2010
Inadequate mechanical strength 5.1.2
5.2
Annex A
Inadequate dimensional tolerances 5.3.2
Annex A
Inadequate information about the selection of 5.1.3
ropes and accessories and their inadequate
5.3
integration into the machine
6.8
7
Inadequate information about abnormal 6
conditions of assembly/ testing/ use and
7
maintenance
Inadequate information for the selection of ropes Annex A
suitable for the particular application
Exposure to puncture hazard 5.3.4
5.3.5
NOTE For the purposes of this Part of EN 13411, inadequate strength of parts means failure to achieve
90 % of the minimum breaking force of the rope.

5 Safety requirements and/or measures
5.1 Ferrule-secured system
5.1.1 General
The ferrule-secured system shall comply with the safety requirements and/or protection measures of this
clause.
In addition, the ferrule-secured systems shall be designed according to the principles of EN ISO 12100 for
relevant hazards but not significant, which are not dealt with in this document.
The ferrule-secured system designer shall carry out type testing in accordance with 5.1.2.
The ferrule-secured termination system designer shall provide instructions on how to produce the ferrule-
secured termination and/or the ferrule-secured endless loop.
The instructions shall at least cover those items given in 5.1.3 and be supported with a written declaration
that the system has passed the type testing requirements of 5.1.2.
In the particular case of oval ferrules with tapered ends used in the securing of the turn-back eye or endless
loop where the rope end is contained within the ferrule, the ferrule-secured system designer shall provide
means whereby the position of the rope end before and after pressing can be ascertained. This shall not
include verification by marking the rope. Only the parallel portion of a ferrule shall be considered load
bearing.
8

---------------------- Page: 10 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
5.1.2 Type testing
5.1.2.1 Sampling
Where the ferrule design follows a mathematical progression throughout a given size range, rope diameter
shall be selected for testing to represent the lower and upper quartiles of that range.
Where the ferrule design does not follow a mathematical progression throughout a given size range, each
rope diameter within that range for which the system is designed shall be selected for testing.
For each rope diameter selected as above, the rope grade shall be the highest for which the system is
designed and at least three FSETs or three ferrule secured endless loops, whichever is the case, shall be
tested.
NOTE 1 In the case of the FSET the number of tests is regarded as two when the test lengths have a FSET at both
ends.
Additionally, sampling shall take into account whether the type of ferrule-secured termination is a turn-back
eye or Flemish eye or whether it is an endless loop, as follows:
a) Turn-back eye ferrule secured-termination
Testing shall be carried out on each of the basic rope types for which the system is designed. For each
basic rope type, testing shall be carried out on ropes having the lowest and highest metallic cross-
sectional area factors for which the system is designed.
NOTE 2 For the purposes of this standard there are four basic rope types, namely single layer rope, rotation-
resistant rope, parallel-closed rope, and spiral strand rope, refer EN 12385-2 for definitions.
b) Flemish-eye ferrule-secured termination
Testing shall be carried out on single layer rope having the lowest and highest metallic cross-sectional
area factors for which the system is designed.
c) Ferule-secured endless loop
Testing shall be carried out on single layer rope having the lowest and highest metallic cross-sectional
factor for which the system is designed.
5.1.2.2 Tensile test
When tested in accordance with 6.2 the FSET shall sustain a force of at least 90 % of the minimum breaking
force of the rope.
NOTE A terminal efficiency of 90 % is equivalent to a termination efficiency factor, K , of 0,9 which is used in the
T
calculation of WLL for slings
When tested in accordance with 6.2 the ferrule-secured endless loop shall sustain a force of at least 90 % of
twice the minimum breaking force of the rope.
5.1.2.3 Fatigue test
When tested in accordance with 6.3 for 75 000 cycles followed by a tensile test in accordance with 6.2 the
FSET and endless loop shall sustain a force of at least 80 % of the minimum breaking force of the rope.
Additionally for Flemish eye ferrule-secured terminations of crane hoist ropes a further fatigue test shall be
performed on an assembly comprising a solid thimble having a peripheral length equivalent to at least four
rope lay lengths. When tested in accordance with 6.4 the ferrule-secured termination shall withstand a
6
minimum of 1x10 cycles and not exhibit a complete strand fracture.
9

---------------------- Page: 11 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)
5.1.3 Instructions to be provided by the ferrule-secured system designer
The ferrule-secured system designer shall provide instructions on at least the following:
a) preparation of the rope end;
b) details of the rope(s) for which the system is designed;
c) matching of the ferrule material and size to the rope diameter and type;
d) positioning of the rope end;
e) procedure for ferrule-securing, i.e. pressing the ferrule;
f) alignment, condition and maintenance of the tooling;
g) procedure for removal of fins;
h) dimensional requirements of the pressed ferrule;
i) marking limitations of the ferrule; and
j) temperature limits of the ferrule secured system.
5.2 Ferrules
5.2.1 Material
The material selected by the ferrule manufacturer shall be non-alloy carbon steel or aluminium and shall
conform to the same specification as that used by the ferrule-secured system designer when satisfying the
type tests.
Non-alloy carbon steel shall be a fully-killed non-ageing normalized steel.
Aluminium shall be in condition ‘F’ according to EN 515.
5.2.2 Dimensions
The dimensions of the ferrule shall be in accordance with those used by the ferrule-secured system designer
when satisfying the type tests.
5.2.3 Manufacture and quality control of ferrule
The tube from which ferrules are made shall be free from any cracks, folds and surface defects.
With the exception of steel ferrules for Flemish eyes, ferrules shall be produced to provide a seam-free
hollow product. Extrusion over mandrels with a bridge shall not be used. Electric resistance welding of steel
tubes may only take place steel ferrules for Flemish eyes and shall be carried out prior to the tube drawing
and normalizing processes.
For each batch of steel ferrules produced from the same cast of steel and heat treatment a sample ferrule
shall be selected and close flattened at ambient temperature, see Figure 1. If the sample fails this test a
further ten (10) or 3 % of the batch of ferrules, whichever is the greater, shall be randomly selected, and all
shall pass the flattening test otherwise the whole batch shall be rejected.

10

---------------------- Page: 12 ----------------------
oSIST prEN 13411-3:2022
prEN 13411-3:2022 (E)

Figure 1 — Close-flattened ferrules
5.2.4 Certificate
The ferrule manufacturer shall supply a certificate stating that the whole batch of ferrules conforms to the
ferrule secured system designer’s specification.
5.2.5 Marking
Each ferrule shall be marked with its size and the ferrule manufacturer’s name or mark except in the case of
ferrules for use with ropes smaller than 8mm diameter where the marking can be on the package.
5.3 Ferrule-securing
5.3.1 General
The procedure adopted by the manufacturer of the ferrule-secured eye termination or endless loop shall be
in accordance with 5.3.2 to 5.3.5 and the instructions provided by the ferrule-secured system designer.
Ferrule-securing shall be carried out by a competent person trained in ferrule-securing.
5.3.2 Matching of ferrule to wire rope
Determine the rope details from the documentation supplied with the rope, see EN 12385-1 and ensure that
the rope is within the scope of the ferrule-secured system as detailed by the ferrule-secured system
designer. In some cases, it wil
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.