IEC 63138-3:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ5 series circular connectors with five RF channels, as well as a detailed specification of the blank format. This document also specifies the mating face dimensions and gauging information of MQ5 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ5 series circular connectors.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-17:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TNC RF coaxial connectors with threaded coupling with a characteristic impedance of 50 Ω. This document prescribes mating face dimensions for high performance connectors - grade 2, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TNC RF connectors. This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides the requirements of WB series glass beads with 50Ω impedance for RF connectors, including the structure dimensions, IEC type designation, rating and characteristics and quality assessments, etc.
These glass beads are used for adaption of coaxial systems to microstrip circuits extensively in microwave communication systems such as TR modules, power modules, integrated circuits and etc. where hermetic seal is required. They can serve as a part of an RF coaxial connector, multi-channel RF connector or hybrid connector, or can be applied directly in various communication module systems as an independent product. They provide 50Ω normative impedance with operating frequency limit up to 65 GHz.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRK bayonet coupling triaxial connectors. The series TRK bayonet coupling triaxial connectors with the advantages of quick connection and separation, high reliability, small size, good salt characteristics, four polarizations to prevent error-mate etc., can be connected with symmetrically twisted pair cables or triaxial cables. It has been widely used in 1553B data bus systems or other communication systems for digital signal transmission.
It prescribes mating face dimensions for series TRK bayonet coupling triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRK triaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Note: Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-1-5:2022 provides test methods for the rise time degradation of radio frequency (RF) connector. This document is applicable to triaxial and other radio frequency connectors.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-1-6:2022 provides test methods for RF power rating and power handling of RF connectors at specified frequency, temperature and altitude. This document is applicable to cabled RF connectors, microstrip RF connectors and RF connector adapters. It is also suitable to test RF channels in multi-channel RF connectors and hybrid connectors.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRL threaded triaxial connectors. Series TRL threaded triaxial connectors with high reliability, small size, good salt characteristics can be connected with symmetrically twisted pair cables or triaxial cables. It has been used in 1553B data bus systems or other communication systems for digital signal transmission.
It prescribes mating face dimensions for series TRL threaded triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRL threaded triaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Note: Metric dimensions are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for preparation of detail specification for type SC threaded RF coaxial connectors with 50 Ω characteristic impedance. The connectors are used with flexible and semi-rigid cables. And they are recommended to be utilized in medium power and low reflection applications up to 11 GHz. The dielectric filled interface is especially beneficial in applications involving severe environmental exposure.
It prescribes mating face dimensions, dimensional details, gauging information for general connectors - grade 2 and standard test connectors - grade 0 as well as test schedules and inspection requirements selected from IEC 61169-1, applicable to all detail specifications relating to type SC RF connectors. Type SC interface specified in this specification is equivalent to type SC-B interface in IEC 60169-21: 1985.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
NOTE: For this part, original dimensions are in inches. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61196-9-2:2022 applies to coaxial communication cables described in IEC 61196-9. It specifies the requirements for 50-0,4 type RF flexible cables. These cables are used in routers, notebook computers, mobile phones or other electronics. The operating frequency is from 5 MHz to 6 000 MHz.

  • Standard
    12 pages
    English language
    sale 15% off

IEC 61196-11:2022 specifies the general requirements of semi-rigid coaxial communication cables with polyethylene (PE) dielectric, including material and construction, IEC type designation, identification, marking and labelling, standard ratings and characteristics, requirements of finished cables, quality assessment, delivery and storage, etc.
This part of IEC 61196 applies to semi-rigid coaxial communication cables with polyethylene (PE) dielectric and tubular outer conductor. These cables are widely used in the interconnection between wireless communication equipment and antenna, as well as RF and microwave electronic equipment, broadcast television, microwave relay, navigation, etc.
This second edition cancels and replaces the first edition published in 2016. This edition includes the following significant technical changes with respect to the previous edition:
a. The scope is more detailed.
b. Outer diameter ratings of the inner conductor recommended.
c. Dielectric: outer diameter ratings of the dielectric recommended.
d. IEC type designation introduced.
e. Standard ratings and characteristics: completely revised.
f. Requirements of finished cables: completely revised.

  • Standard
    16 pages
    English language
    sale 15% off

IEC 61196-11-1:2022 applies to coaxial communication cables described in IEC 61196-11. It specifies the layout and style for detail specifications for semi-rigid coaxial communication cables with polyethylene (PE) dielectric. Semi-rigid coaxial communication cables with polyethylene (PE) dielectric are widely used in the interconnection between wireless communication equipment and antenna, as well as RF and microwave electronic equipment, broadcast television, microwave relay, navigation, etc.
This part of IEC 61196 is used in conjunction with IEC 61196-1 and IEC 61196-11, which determines the layout and style for detail specifications, based on the blank detail specification. This second edition cancels and replaces the first edition published in 2016.This edition includes the following significant technical changes with respect to the previous edition: a. engineering information: Maximum tensile force and average power introduced, b. electrical, environmental and mechanical characteristics more detailed,
c. requirements for “Content of toxic and harmful substances” introduced.

  • Standard
    11 pages
    English language
    sale 15% off

IEC 63138-3:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ5 series circular connectors with five RF channels, as well as a detailed specification of the blank format. This document also specifies the mating face dimensions and gauging information of MQ5 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ5 series circular connectors.

  • Standard
    57 pages
    English and French language
    sale 15% off

IEC 61169-17:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TNC RF coaxial connectors with threaded coupling with a characteristic impedance of 50 Ω.
This document prescribes mating face dimensions for high performance connectors - grade 2, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TNC RF connectors.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 63295:2022 provides the requirements for WB series glass beads with 50 Ω impedance for RF connectors, including, among other, the structure dimensions, IEC type designation, rating and characteristics, and quality assessment. These glass beads are used for the adaption of coaxial systems to microstrip circuits used extensively in microwave communication systems such as TR modules, power modules, integrated circuits where hermetic seal is required.

  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 61169-68:2022 which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRK bayonet coupling triaxial connectors. The series TRK bayonet coupling triaxial connectors having the advantages of quick connection and separation, high reliability, small size, good salt characteristics, four polarizations to prevent error-mate etc., can be connected to symmetrically twisted pair cables or triaxial cables.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    54 pages
    English and French language
    sale 15% off

IEC 61169-67:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRL threaded triaxial connectors. Series TRL threaded triaxial connectors with high reliability, small size, good salt characteristics can be connected with symmetrically twisted pair cables or triaxial cables. It has been used in 1553B data bus systems or other communication systems for digital signal transmission.
It specifies mating face dimensions for series TRL threaded triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRL threaded triaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    40 pages
    English and French language
    sale 15% off

IEC 61169-1-6:2022 provides test methods for RF power rating and power handling of RF connectors at specified frequency, temperature and altitude.
This document is applicable to cabled RF connectors, microstrip RF connectors and RF connector adapters. It is also suitable to test RF channels in multi-channel RF connectors and hybrid connectors.

  • Standard
    28 pages
    English and French language
    sale 15% off

IEC 61169-21:2022 which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SC threaded RF coaxial connectors with 50 Ω characteristic impedance. The connectors are used with flexible and semi-rigid cables. They are recommended for use in medium power and low reflection applications up to 11 GHz. The dielectric filled interface is especially beneficial in applications involving severe environmental exposure.
This document specifies mating face dimensions, dimensional details, gauging information for general connectors − grade 2 and standard test connectors − grade 0 as well as test schedules and inspection requirements selected from IEC 61169-1, applicable to all detail specifications relating to type SC RF connectors. Type SC interface specified in this document is equivalent to type SC-B interface in IEC 60169-21:1985.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    58 pages
    English and French language
    sale 15% off

IEC 61935-2:2021 specifies test methods for balanced and coaxial cords, which are used as equipment cords, patch cords, and CP cords, within cabling systems, in accordance with ISO/IEC 11801-1. The test methods and associated requirements are provided to demonstrate performance and reliability and to ensure compatibility of these balanced and coaxial cords during their operational lifetime. This document may also be used for providing test methodology for assessing the performance of other cords.
This fourth edition cancels and replaces the third edition published in 2010. This edition includes the following significant technical changes with respect to the previous edition:
- inclusion of cords up to category 8.1 and category 8.2, as defined in ISO/IEC 11801-1.

  • Standard
    67 pages
    English and French language
    sale 15% off

IEC 61196-1-200:2022 is available as IEC 61196-1-200:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61196-1-200:2022 gives the general requirements and conditions for environmental tests to be performed on coaxial communication cables and applies to the IEC 61196-1-2xx series, which specifies environmental test methods for coaxial communication cables. Further test details (e.g. temperature, duration) and/or test requirements can be given in the relevant test procedure and/or the relevant sectional or detail specification. This third edition cancels and replaces the second edition published in 2014. This edition includes the following significant technical changes with respect to the previous edition:
a. Update of Annex A.

  • Standard
    13 pages
    English and French language
    sale 15% off

IEC 61169-1-5:2022 provides test methods for the rise time degradation of radio frequency (RF) connector.
This document is applicable to triaxial and other radio frequency connectors.

  • Standard
    24 pages
    English and French language
    sale 15% off

This part of IEC 62037 defines the test fixtures and procedures recommended for measuring
levels of passive intermodulation generated by antennas, typically used in wireless
communication systems. The purpose is to define qualification and acceptance test methods for
antennas for use in low intermodulation (low IM) applications

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 defines a procedure to measure levels of passive intermodulation
generated by a coaxial cable assembly.
This test method is applicable to jumper cables, i.e. cable assemblies intended to provide
interface flexibility between rigid devices. It is also used to evaluate cable assemblies that are
subjected to motion in operation

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 deals with the general requirements and measuring methods for
intermodulation (IM) level measurement of passive RF and microwave components, which can
be caused by the presence of two or more transmitting signals.
The test procedures given in this document give the general requirements and measurement
methods required to characterize the level of unwanted IM signals using two transmitting signals.
The IEC 62037 series addresses the measurement of PIM, but does not cover the long-term
reliability of a product with reference to its performance.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 defines test fixtures and procedures recommended for measuring levels
of passive intermodulation generated by filters, typically used in wireless communication
systems. The purpose is to define qualification and acceptance test methods for filters for use
in low intermodulation (low IM) applications

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 defines the impact test on coaxial connectors to evaluate their robustness
against weak connections and particles inside the connector, as independently as possible from
the effects of cable PIM (passive intermodulation).
For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate
transmission-line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses
on the connectors, a series of impacts is applied to the connectors while measuring the PIM.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61935-2-22:2021 is a blank detail specification describing cords which are compliant with category 6 cabling requirements, as specified in the ISO/IEC 11801-1.
ISO/IEC 11801 and ISO/IEC 11801 series definitions and specifications referenced by this blank detail specification are currently covered by ISO/IEC 11801-1.
This document is intended to be used in conjunction with IEC 61935-2, IEC 61156-1, IEC 61156-6, IEC 60603-7-41 and IEC 60603-7-51. The blank detail specification determines the layout and style for detail specifications describing cords with transmission characteristics up to 500 MHz for digital communications. Detail specifications, based on the blank detail specification, can be prepared by a national organization, a manufacturer, or a user.
Test configuration applicable to cords is detailed in the IEC 61935-2.

  • Standard
    11 pages
    English language
    sale 15% off

IEC 61935-2-21:2021 is a blank detail specification describing cords which are compliant with category 6 cabling requirements, as specified in ISO/IEC 11801-1. ISO/IEC 11801 and ISO/IEC 11801 series definitions and specifications referenced by this blank detail specification are currently covered by ISO/IEC 11801-1.
This document is intended to be used in conjunction with IEC 61935-2, IEC 61156-1, IEC 61156-6, IEC 60603-7-4 and IEC 60603-7-5. The blank detail specification determines the layout and style for detail specifications describing cords with transmission characteristics up to 250 MHz for digital communications. Detail specifications, based on the blank detail specification, can be prepared by a national organization, a manufacturer, or a user.
The test configuration applicable to cords is detailed in IEC 61935-2.

  • Standard
    11 pages
    English language
    sale 15% off

IEC 62037-2:2021 defines a procedure to measure levels of passive intermodulation generated by a coaxial cable assembly. This test method is applicable to jumper cables, i.e. cable assemblies intended to provide interface flexibility between rigid devices. It is also used to evaluate cable assemblies that are subjected to motion in operation.
This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a. criteria for application of mechanical stress revised to be a function of advertised cable bend radius.

  • Standard
    16 pages
    English and French language
    sale 15% off

The present document specifies technical characteristics and methods of measurements for Point-to-point (P-P) Digital
Fixed Radio Systems (DFRS) operating in frequency bands allocated to Fixed Service (FS) from 1 GHz to 86 GHz,
corresponding to the appropriate frequency bands from 1,4 GHz to 86 GHz as described in annex B to annex J.
Systems in the scope of the present document are generally intended to operate in full Frequency Division Duplex
(FDD) and cover also unidirectional applications. Time Division Duplex (TDD) applications, when possibly applicable
in a specific band, are explicitly mentioned as appropriate in annex B through annex J.
Systems may be composed by equipment without antennas (see informative annex Q for background) or equipment
including integral or dedicated antenna, both cases are in the scope of the present document.
The present document covers requirements to demonstrate that radio equipment both effectively uses and supports the
efficient use of radio spectrum in order to avoid harmful interference
NOTE: The relationship between the present document and the essential requirements of article 3.2 of
Directive 2014/53/EU [i.1] is given in annex A.

  • Standard
    162 pages
    English language
    sale 15% off
  • Standard
    162 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    162 pages
    English language
    sale 15% off
  • Draft
    162 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for coaxial connectors with 10 mm inner diameter of outer conductor, characteristic impedance 50 Ω, series 4,3-10 with screw type, hand screw type or quick-lock type coupling, for an upper operating frequency limit of 6 GHz, for use in wireless telecommunication and wireless network applications in conjunction with appropriate transmission line types for these applications. It also describes mating face dimensions for general purpose connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to 4,3-10 series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document applies to Digital Fixed Radio Systems (DFRS) in point-to-point operation with integral and
external antennas in the frequency range of 1 GHz to 86 GHz corresponding to the appropriate frequency bands
1,4 GHz to 86 GHz as described in ETSI EN 302 217-2 [16], annex B to annex J.
The present document summarizes:
• all characteristics, principles and, of utmost importance, terms and definitions that are common to all
P-P equipment and antennas and its consultation is necessary when using all other parts of ETSI EN 302 217
series;
• all system-dependent requirements for Point-to-Point (P-P) equipment. These requirements are introduced in
two different clauses sub-sets:
- Main requirements are requirements that are also related to the "essential requirements" under
article 3.2 of Directive 2014/53/EU [i.1] and further detailed in the Harmonised Standard ETSI
EN 302 217-2 [16].
- Complementary requirements are requirements that are not related to essential requirements under
article 3.2 of Directive 2014/53/EU [i.1]. Nevertheless they have been commonly agreed for proper
system operation and deployment when specific deployment conditions or compatibility requirements are
present. Compliance to all or some of these requirements is left to manufacturer decision.
Health and safety requirements and EMC conditions and requirements are not considered in the ETSI EN 302 217
series.

  • Standard
    80 pages
    English language
    sale 15% off
  • Standard
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    80 pages
    English language
    sale 15% off
  • Draft
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62153 specifies a method to extrapolate the test results of transfer
impedance to higher frequencies and the test results of screening attenuation to lower
frequencies when measured with the triaxial set-up in accordance with IEC 62153-4-3,
IEC 62153‑4‑4 [1]1 and IEC 62153-4-15. This method is applicable for homogenous screens,
i.e. screens having a transfer impedance directly proportional to length. The transfer
impedance can have any frequency behaviour, i.e. it could have a behaviour where it does not
increase with 20 dB per decade as observed for screens made of a foil and a braid.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The absorbing clamp method is suitable to determine the screening- or the coupling attenuation of metallic communication cables in the frequency range of 30 MHz to 2400 MHz, depending on the performance of the clamp. It is an alternative method to the the triaxial method of IEC 62153-4-4 or IEC 62153-4-9. Due to the undefined outer circuit of this absorbing clamp method, the test results obtained at different places and laboratories could vary by at least ± 6dB.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62153 specifies the procedures for measuring with triaxial cell the transfer
impedance, screening attenuation or the coupling attenuation of connectors, cable assemblies
and components, for example accessories for analogue and digital transmission systems, and
equipment for communication networks and cabling.
Measurements can be achieved by applying the device under test directly to the triaxial cell or
with the tube-in-tube method in accordance with IEC 62153-4-7.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62153 deals with the triaxial tube in tube method. This triaxial method is
suitable to determine the surface transfer impedance and/or screening attenuation and
coupling attenuation of mated screened connectors (including the connection between cable
and connector) and cable assemblies. This method could also be extended to determine the
transfer impedance, coupling or screening attenuation of balanced or multipin connectors and
multicore cable assemblies. For the measurement of transfer impedance and screening- or
coupling attenuation, only one test set-up is needed.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document is applicable to antennas (stand-alone, dedicated or integral antennas according to the definitions
of terms in clause 3.1) used in MultiPoint (MP) Digital Fixed Radio Systems (DFRS) (see note 1) intended for use in
the frequency bands identified in ETSI EN 302 326-2 [i.4].
NOTE 1: Applications intended for offering in the bands 3,4 GHz to 3,8 GHz the option of Nomadic Wireless
Access (NWA), according to the NWA definition in Recommendation ITU-R F.1399 [i.3], are also
considered in the scope of the present document.
For Multipoint Fixed Radio Systems, antenna characteristics are not considered relevant to essential requirements under
article 3.2 of Directive 2014/53/EU [i.1] (see note 2). Antenna characteristics in the present document are considered
applicable whenever they are considered appropriate for the associated multipoint radio system.
NOTE 2: Rationale can be found in ETSI TR 101 506 [i.2].

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    38 pages
    English language
    sale 15% off
  • Standard
    38 pages
    English language
    sale 15% off
  • Standard
    38 pages
    English language
    sale 15% off
  • Draft
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document specifies technical characteristics and methods of measurements applicable to radio equipment
used in MultiPoint (MP) Digital Fixed Radio Systems (DFRS) (see note 2) designed for use in the following sub-ranges
(see note 3):
• 30 MHz to 1 GHz.
• 1 GHz to 3 GHz.
• 3 GHz to 11 GHz.
• 24,25 GHz to 29,5 GHz.
• 31,0 GHz to 33,4 GHz.
• 40,5 GHz to 43,5 GHz.
NOTE 1: The relationship between the present document and essential requirements of article 3.2 of Directive
2014/53/EU [i.1] is given in Annex A.
The present document is applicable to multipoint radio system equipment using any arbitrary access method. It applies
to all equipment composing the MP systems, i.e. to Central Station (CS), Terminal Station (TS) and Repeater Station
(RS).
Time Division Duplex (TDD) or Frequency Division Duplex (FDD or H-FDD) can be used on an equivalent basis.
Systems implementing an actual FH-CDMA access method with hopping period exceeding 400 ms are not considered
within the scope of the present document.
NOTE 2: Applications intended for offering in the bands 3,4 GHz to 3,8 GHz the option of Nomadic Wireless
Access (NWA), according to the NWA definition in Recommendation ITU-R F.1399 [i.14], are also
considered in the scope of the present document.
NOTE 3: For more information on the applicable frequency bands, refer to Annex F.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    90 pages
    English language
    sale 15% off
  • Standard
    90 pages
    English language
    sale 15% off
  • Standard
    87 pages
    English language
    sale 15% off
  • Draft
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-54:2021 is available as IEC 61169-54:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61169-54:2021 provides information and rules for the preparation of detail specifications (DS) for coaxial connectors with 10 mm inner diameter of outer conductor, characteristic impedance 50 Ω, series 4,3-10 with screw type, hand screw type or quick-lock type coupling, for an upper operating frequency limit of 6 GHz, for use in wireless telecommunication and wireless network applications in conjunction with appropriate transmission line types for these applications. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. This second edition cancels and replaces the first edition published in 2016. This edition includes the following significant technical changes with respect to the previous edition:
- Table 8: some values changed.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 61196-6-1:2021 is available as IEC 61196-6-1:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61196-6-1:2021 applies to coaxial communication cables as described in IEC 61196-6. It specifies the requirements for drop cables for use in cabled television distribution networks operating at temperatures between −40 °C and +70 °C and in the frequency range from 5 MHz to 1 000 MHz or from 5 MHz to 3 000 MHz. This second edition cancels and replaces the first edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition:
- Annex A, Cable identification and marking was added.

  • Standard
    13 pages
    English language
    sale 15% off

IEC 61196-6:2021 is available as IEC 61196-6:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61196-6:2021 applies to coaxial communications cables. It specifies the requirements for CATV drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals, interactive services, surveillance & control systems, and satellite television receiving systems according to the requirements of IEC 60728-1, IEC 60728-1-1, IEC 60728-101, IEC 60728-10, ISO/IEC 11801-1 and ISO/IEC 11801-4. This also includes the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. This second edition cancels and replaces the first edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition:
- extended scope,
- revised sheath marking and labelling.

  • Standard
    18 pages
    English language
    sale 15% off

IEC 61196-7:2021 is available as IEC 61196-7:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61196-7:2021 applies to coaxial communications cables. It specifies the requirements for cables for broadcast and communications technologies (BCT) cabling in accordance with ISO/IEC 11801-4 for use in cabled television distribution networks operating at temperature between −40 °C and +70 °C and in the frequency range from 5 MHz to 6 000 MHz.This second edition cancels and replaces the first edition published in 2011. This edition includes the following significant technical changes with respect to the previous edition:
- extension of frequency range up to 6 GHz,
- revised sheath marking and labelling,
- a table with typical cable characteristics was added as annex B.

  • Standard
    17 pages
    English language
    sale 15% off

IEC 62153-4-5:2021 is suitable to determine the screening- or the coupling-attenuation of metallic communication cables in the frequency range of 30 MHz to 1 000 MHz (2 400 MHz), depending on the performance of the clamp. It is an alternative method to the triaxial method of IEC 62153-4-4 or IEC 62153-4-9. Due to the undefined outer circuit of this absorbing clamp method, the test results obtained at different places and laboratories could vary by at least ± 6 dB.
This second edition cancels and replaces the first edition published in 2006. This edition includes the following significant technical changes with respect to the previous edition:
a. reorganisation of clauses and annexes;
b. extension of frequency range to 2,4 GHz;
c. application of a virtual balun respectively balunless test procedure with multiport VNA.

  • Standard
    81 pages
    English and French language
    sale 15% off

IEC 62153-4-16:2021 specifies a method to extrapolate the test results of transfer impedance to higher frequencies and the test results of screening attenuation to lower frequencies when measured with the triaxial set-up in accordance with IEC 62153-4-3, IEC 62153‑4‑4 and IEC 62153-4-15. This method is applicable for homogenous screens, i.e. screens having a transfer impedance directly proportional to length.
This second edition cancels and replaces the first edition published in 2016. This edition includes the following significant technical changes with respect to the previous edition:
- replacement of the conversion formula which was limited to a matched DUT by a new conversion formula suitable for any load conditions.

  • Standard
    41 pages
    English and French language
    sale 15% off

This part of IEC 63249 defines general requirements and test methods for waveguide to coaxial
adapters. It includes terms and definitions, design and construction, ratings and characteristics,
climatic categories, IEC type designation, requirements and test methods, quality assessment,
marking, etc.
It provides the basis for establishing the sectional specifications for various waveguide to
coaxial adapters.
This specification applies to waveguide to coaxial adapters (short name adapter).
For the purpose of this specification, according to ends, adapters are classified as the following:
– Class I: Waveguide to coaxial connector adapter, waveguide at one end and coaxial
connector at the other end;
– Class II: Waveguide to coaxial cable adapter, waveguide at one end,and coaxial cable at
the other end;
– Class III: Waveguide to coaxial cabled connector adapter, waveguide at one end,and
coaxial cabled connector at the other end.
According to whether the inner conductor probe of coaxial end is connected with the inner wall
of waveguide cavity or not, adapters are classified as the following:
– Connected adapter: Inner conductor probe of coaxial end is connected with inner wall of
waveguide cavity;
– Disconnected adapter: Inner conductor probe of coaxial end is disconnected with inner wall
of waveguide cavity.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62153-4-15:2021 is available as IEC 62153-4-15:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62153-4-15:2021 specifies the procedures for measuring with triaxial cell the transfer impedance, screening attenuation or the coupling attenuation of connectors, cable assemblies and components, for example accessories for analogue and digital transmission systems, and equipment for communication networks and cabling. This second edition cancels and replaces the first edition published in 2015.This edition includes the following significant technical changes with respect to the previous edition:
a) measurement of coupling attenuation of balanced connectors, assemblies and components with balun and balunless added;
b) application of a test adapter was added;
c) application of a moveable shorting plane;
d) application of the triaxial "absorber" cell;
e) correction of test results in the case that the receiver input impedance R is higher than the characteristic impedance of the outer circuit Z2.

  • Standard
    90 pages
    English and French language
    sale 15% off

IEC 62153-4-7:2021 is available as IEC 62153-4-7:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62153-4-7:2021 deals with the triaxial tube in tube method. This triaxial method is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and multicore cable assemblies. This third edition cancels and replaces the second edition published in 2015 and its Amendment 1:2018.This edition includes the following significant technical changes with respect to the previous edition:
- Annex E contains informative information about the direct measurement of screening effectiveness of connectors;
- Annex F gives normative information about mixed mode parameters;
- Annex G contains normative information about accessories for measuring coupling attenuation;
- Annex H discusses the low frequency screening attenuation.

  • Standard
    114 pages
    English and French language
    sale 15% off

IEC 61196-1-212:2021 describes three methods to determine the UV resistance of sheath materials for electric and optical fibre cables. These tests apply for outdoor and indoor cable applications according to the product standard. The samples of sheath are taken from the finished cables. Although this test method is written principally for communication cables, it can be used for energy cables if called up by the relevant product standard.

  • Standard
    19 pages
    English language
    sale 15% off

IEC 63249-1:2021 defines general requirements and test methods for waveguide to coaxial adapters. It includes terms and definitions, design and construction, ratings and characteristics, climatic categories, IEC type designation, requirements and test methods, quality assessment, marking, etc.
It provides the basis for establishing the sectional specifications for various waveguide to coaxial adapters.

  • Standard
    53 pages
    English and French language
    sale 15% off