Search Catalog

Standardization Organization
ICS
Technical Committee
Directive
Mandate

This European Standard deals with the safety of electric ondol-mattresses for household and similar purposes, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances. This standard also applies to control units supplied with the appliance

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

The present document defines Product Specific Requirements for Life Cycle Assessment (LCA) of Smartphones so that it is possible to compare the LCA between different smartphone models on SKU level (e.g. considering different memory configurations). The present document provides a methodology for evaluating the environmental impact of smartphones objectively and transparently and is based upon the Life Cycle Assessment (LCA) framework standardized in ETSI ES 203 199 [1] and IEC 63366 [i.1]. The purpose of the present document is to:• Provide smartphone-specific requirements, i.e. Product Specific Rules (PSR), in addition to those of ETSI ES 203 199 [1] and IEC 63366 [i.1] to ensure comparability of LCA studies of smartphones on SKU level. • Harmonize the LCAs of smartphones. • Increase the transparency and facilitate the interpretation of LCA studies of smartphones. • Facilitate the communication of LCA studies of smartphones on SKU level. The present document is valid for all types of smartphones. Moreover, the present document defines a set of requirements for which the LCA practitioners will comply. Comparisons of results from LCA studies of smartphones which belong to the same product family, including assessments which have been performed by different organizations, are within the scope of the present document.

  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    66 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances, including direct current (DC) supplied appliances and battery-operated appliances

  • Amendment
    6 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances, including direct current (DC) supplied appliances and battery-operated appliances

  • Standard
    29 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of microwave appliances intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.

  • Standard
    49 pages
    English language
    e-Library read for
    1 day

This document specifies a procedure for determining hydroxyacyl-coenzyme A dehydrogenase (HADH) activity in poultry meat samples by spectrophotometry. The results provide an indication of whether poultry breast meat has been previously frozen, based on the ratio of relative HADH activity, and can be used to verify the labelling of poultry breast meat sold as chilled poultry.
This document is applicable specifically to chicken breast meat. It is not applicable to other cuts and/or types of meat unless these have been validated and appropriate limits have been established.
When following the procedure outlined in this document, for a single sample pressing results in 96,6 % of samples being correctly classified. If a correct classification rate of 99,9 % is required, three sample pressings are necessary; i.e. three chicken breasts (one pressing from each), selected randomly from a batch.
This document is not applicable to minced meat or to poultry preparations.

  • Standard
    16 pages
    English language
    e-Library read for
    1 day

The present document applies to the following radio equipment type:
• User Equipment for Evolved Universal Terrestrial Radio Access (E-UTRA).
This radio equipment type is capable of operating in all or any part of the frequency bands given in tables from 1-1 through 1-5.

  • Standard
    154 pages
    English language
    sale 15% off
  • Standard
    154 pages
    English language
    sale 15% off
  • Standard
    154 pages
    English language
    sale 15% off
  • Standard
    154 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of electric ondol-mattresses for household and similar purposes, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances. This standard also applies to control units supplied with the appliance

  • Amendment
    6 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of electric vaporizers for household and similar use, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances

  • Amendment
    6 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of electric vaporizers for household and similar use, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances

  • Standard
    21 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of microwave appliances intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.

  • Amendment
    6 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances

  • Amendment
    7 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances

  • Standard
    28 pages
    English language
    e-Library read for
    1 day

IEC 62820‑1‑2:2026 specifies the technical requirements for the composition, functions, performance and test methods of building intercom systems using the Internet protocol (IP), and it is a supplement to IEC 62820‑1‑1. This document is applicable to the IP building intercom systems for both residential and commercial buildings.

  • Draft
    21 pages
    English language
    e-Library read for
    1 day

This document defines the measurement method of optical image stabilization performance for still images compensating for handheld blur consisting of three rotational components, yaw, pitch and roll. It applies to consumer digital cameras with optical image stabilization for still images. Apparatuses such as camcorders and mobile phones with still image shooting functionality are within the scope of this document.

  • Standard
    62 pages
    English language
    sale 15% off

This document specifies requirements for the classification and grading of civil uncrewed aircraft systems (UAS). This document applies to heavier-than-air aircraft as well as aerostats of any possible architecture. This document applies to the industrial conception, development, design, production and delivery of civil UAS. It also applies to operations, modification, repair and maintenance of civil UAS. NOTE The characteristics in this document can be used individually or in combination, to meet specific needs of the classification and grading of civil UAS. This document does not apply to taxonomies of: automation levels; vertiports; UTM services.

  • Standard
    11 pages
    English language
    sale 15% off

In addition to the requirements of IEC 61326-1, this part of IEC 61326 specifies the EMC test requirements for process automation equipment using at least one Ethernet-APL (Ethernet ADVANCED PHYSICAL LAYER) compliant port according IEC TS 63444. The type of equipment covered by this document includes INFRASTRUCTURE DEVICES such as switches as well as measurement and control devices. This document provides requirements for the EMC test setups of the APL interface for devices intended for use in process control and process measurement. The other functions of the equipment remain covered by other parts of the IEC 61326 series. NOTE Ethernet-APL uses IEEE Std. 802.3-2022 Ethernet Physical Layer 10BASE-T1L, suitable to be used for full- duplex communication over a single balanced pair of conductors. The test levels are based on the intended environment as stated in the product’s specification or user documentation and selected appropriately from IEC 61326-1.

  • Draft
    44 pages
    English language
    e-Library read for
    1 day

IEC 60086-2-2:2026 is applicable to primary batteries which are based on standardised lithium (non-aqueous) electrochemical systems. It specifies: - the physical dimensions, - the discharge test conditions and discharge performance requirements. This first edition cancels and replaces the fourteenth edition of IEC 60086-2 published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) separation of batteries with aqueous electrolyte into a separate Part 2-1: Physical and electrical specifications; b) maximum open circuit voltage of FR10G445 and FR14505 was changed from 1,83 to 1,90 V; c) load of digital audio test for FR10G445 was changed from 50 mA to 75 mA and MAD was modified; d) portable lighting test was added for FR10G445; e) motor/toy and radio /clock /remote control test was added for FR14505; f) in Clause 3, terms were reordered according their functions: electrochemical systems, electrochemical systems, electrical characteristics and specifications; g) Annex D for common designation of IEC 60086 2:2021 was moved to IEC 60086 1:2026, as Annex H; h) Annex E for Compliance checklist of IEC 60086 2:2021 was removed and merged into Annex J of IEC 60086 1:2026.

  • Draft
    27 pages
    English language
    e-Library read for
    1 day

This document specifies a test method to determine if a fitting will fail in crushing mode under compression before a predefined percentage deformation of moulded fittings for thermoplastics piping systems and provides recommended percentage deformation for fittings (see Annex A). This document applies to fittings made from unplasticized poly(vinyl chloride) (PVC-U), high-impact poly(vinyl chloride) (PVC-HI), chlorinated poly(vinyl chloride) (PVC-C), polyethylene (PE), polypropylene (PP), acrylonitrile-butadiene-styrene (ABS), poly(vinylidene difluoride) (PVDF), poly(phenyl sulfone) (PPSU) and unplasticized polyamide (PA-U). This document can also be applied to moulded fittings made from other thermoplastics, in which case the test conditions can differ.

  • Standard
    6 pages
    English language
    sale 15% off

This document specifies requirements and recommendations for designing, developing, and establishing integrated clinical decision support systems (CDSS) for research purposes in personalized medicine. This document can be used as an implementation guideline for setting up computational modelling workflows to enable such systems. It addresses data quality, formatting and handling, as well as the processes generating such data, and the set-up, validation, simulation, storing and sharing of computational models used for this specific purpose in personalized medicine. This includes recommendations and rules for configuration, descriptions, annotations, interoperability, integration, access and provenance of such data and derived models in an interpretable and evidence-based manner. This document also specifies how to integrate these rules with clinical trials execution applying standard operating procedures. Furthermore, requirements and recommendations for data used to construct or required for validating such models are addressed. This document does not apply for computational models used for diagnostic or therapeutic purposes in standard clinical practice, outside of a formal research or investigational setting.

  • Technical specification
    43 pages
    English language
    sale 15% off

This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 1:2014, EN 60728 1 1:2014, EN 60728 101:2017, EN 60728 10:2014, EN 50173 1:2018 and EN 50173 4:2018. This also includes the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Draft
    16 pages
    English language
    e-Library read for
    1 day

This document specifies guidelines and requirements for conducting life cycle inventory (LCI) studies of steel products reflecting steel’s capacity for closed-loop recycling, including: specification of the declared unit used for LCI calculation of steel products; definition of the system boundaries used for LCI calculation of steel products; evaluation of scrap in LCI calculation of steel products; evaluation of co-products in LCI calculation of steel products; reporting of LCI calculation results of steel products. The application of LCI results, including life cycle impact assessment (LCIA), is outside the scope of this document.

  • Standard
    43 pages
    English language
    sale 15% off

IEC 60127-4:2026 relates to universal modular fuse-links (UMF) for printed circuits and other substrate systems, used for the protection of electric appliances, electronic equipment, and component parts thereof, normally intended to be used indoors. It does not apply to fuse-links for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere. These fuses are normally intended to be mounted or replaced only by appropriately skilled persons using specialized equipment. This document applies in addition to the requirements of IEC 60127-1. The objectives of this part of IEC 60127 are as given in IEC 60127-1, with the additional requirement of a degree of non-interchangeability. This fourth edition cancels and replaces the third edition published in 2005, Amendment 1:2008 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) align to IEC 60127-1:2023, third edition; b) enhance the rated current of UMFs to 100A and provide the corresponding maximum voltage drop and maximum sustained dissipation; c) modify the figures; d) update the normative references to the latest version. This International Standard is to be used in conjunction with IEC 60127-1:2023

  • Draft
    33 pages
    English language
    e-Library read for
    1 day

This document specifies calculation methods for determining the required mass flow to be relieved for each specified conditions described in Table 1. Recommendations for pressure relief devices for cryostats are given in Annex A.

  • Standard
    37 pages
    English language
    sale 15% off
  • Standard
    36 pages
    French language
    sale 15% off

This document specifies the general requirements for basic safety and essential performance of electric radial pulse tonometric devices. This document does not apply to the accuracy of differential diagnosis or interpretation of the diagnostic data obtained from the use of such devices. This document applies to pressure-based radial pulse tonometric devices.

  • Standard
    9 pages
    English language
    sale 15% off

This part of IEC 63082 defines the concepts and terminology necessary to understand and communicate effectively about intelligent device management (IDM). This document explains the relationship between IDM and other existing asset management standards. Additionally, this document describes principles and defines organizational and functional structures associated with IDM. This document also introduces the concept of IDM program for coordination of multiple stakeholders.

  • Draft
    128 pages
    English language
    e-Library read for
    1 day

This document specifies the data exchange requirements between related systems within the smart city for electric vehicle (EV)-based demand response (DR) services utilizing nomadic devices as follows: EV-based DR service for demand reduction, called “demand response” during the shortage of reserve on electric grid or in response to a fine dust warning issued according to an air quality forecast; EV-based DR for demand increase, called “reverse demand response”, instead of curtailment during excess electricity generation by renewable energy sources such as the sun and wind. This document defines the requirements of main actors such as the EV, nomadic device, smart city cloud, charging station and service provider to support EV-based DR services. This document also defines the data set and data processing procedure requirements for EV-based DR services.

  • Standard
    26 pages
    English language
    sale 15% off

IEC 60086-2-1:2026 is applicable to primary batteries which are based on standardised electrochemical systems using aqueous electrolytes. It specifies: - the physical dimensions, - the discharge test conditions and discharge performance requirements. IEC 60086-2-1: 2026 cancels and replaces the fourteenth edition of IEC 60086 2 published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) separation of lithium batteries into IEC 60086-2-2: Physical and electrical specifications; b) in Clause 3, terms were reordered according to their functions: electrochemical systems, electrical characteristics and specifications; c) TR03 and TR6 were added in Category 1, Round batteries; d) load of digital audio test for LR03, TR03 and R03 was changed from 50 mA to 75 mA and MAD was modified; e) personal grooming test of LR6 was added instead of high drain application test; f) high drain application test was added for TR6; g) radio /clock /remote control test was added for R6S; h) CD, digital audio, wireless gaming and accessories test was removed for LR6, R6P and R6S; i) 4,5 V of common designation was added for 3LR12, 3R12P and 3R12S; j) Annex D for common designation of IEC 60086 2:2021 was moved to IEC 60086 1:2026, as Annex H; k) Annex E for Compliance checklist of IEC 60086 2:2021 was removed and merged into Annex J of IEC 60086 1:2026.

  • Draft
    49 pages
    English language
    e-Library read for
    1 day

This document specifies general requirements for the basic safety and essential performance of transcutaneous electrical acupoint stimulators (TEAS) with a focus on devices intended to stimulate acupoints on the human body. It applies to all types of TEAS specifically designed for acupoint-related therapeutic usage, only in the context of professional traditional Chinese medicine (TCM) healthcare services. It is not applicable to invasive electro-acupuncture stimulators for the application of electric currents via acupuncture needles inserted into the body.

  • Standard
    9 pages
    English language
    sale 15% off

This document specifies requirements for process development for forming, sealing and assembly of packaging for medical devices to be terminally sterilized, when utilizing heat sealing technologies. This document recommends minimum heat sealing equipment features to support subsequent validation, process control and monitoring. This document applies to both preformed sterile barrier systems and sterile barrier systems. This document utilizes the sterile barrier system specification to develop the process specification using the principles of risk management. This document is intended to be used prior to process validation. NOTE ISO 11607-2 provides requirements for process specification and process validation.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    31 pages
    French language
    sale 15% off

This document applies to hearing aid fitting management (HAFM) services offered by hearing aid professionals (HAP) when providing benefit for their clients. The provision of hearing aids relies on the knowledge and practices of a hearing aid professional, to ensure the proper fitting and adequate service in the interest of the client with hearing loss. This document specifies general processes of HAFM from the client profile to the follow-up through administering, organising and controlling hearing aid fitting through all stages. It also specifies important preconditions such as education, facilities and systems that are required to ensure proper services. The focus of this document is the services offered to the majority of adult clients with hearing impairment. It is recognized that certain populations with hearing loss such as children, persons with other disabilities or persons with implantable devices can require services outside the scope of this document. This document generally applies to air conduction hearing aids and for the most part also to bone conduction devices. Hearing loss can be a consequence of serious medical conditions. Hearing aid professionals are not in a position to diagnose or treat such conditions. When assisting clients seeking hearing rehabilitation without prior medical examination, hearing aid professionals are expected to be observant of symptoms of such conditions and refer to proper medical care. Further to the main body of the document, which specifies the HAFM requirements and processes, several informative annexes are provided. Appropriate education of hearing aid professionals is vital for exercising HAFM. Annex A defines the competencies required for the HAFM processes. Annex B offers a recommended curriculum for the education of hearing aid professionals. Annex C is an example of an appropriate fitting room. Annex D gives guidance on the referral of clients for medical or other specialist examination and treatment. Annex E is a recommendation for important information to be exchanged with the client during the process of HAFM. Annex F is a comprehensive terminology list offering definitions of the most current terms related to HAFM. It is the intention that these annexes be helpful to those who wish to deliver HAFM of the highest quality.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    46 pages
    French language
    sale 15% off

This document defines the assessment of endurable longitudinal compressive force (LCF) of a vehicle. The endurable longitudinal compressive force is a parameter depending on the vehicle design. It is used to estimate the risk of derailment of a vehicle as a result of being subjected to longitudinal compressive force, under operating conditions.
NOTE 1   As operating conditions can vary in several aspects (infrastructure, train configurations etc.), this document defines uniform assessments of endurable longitudinal compressive force per vehicle in specific operating conditions. The main assessment of endurable longitudinal compressive force for conventional trains is derived from UIC 530-2:2011, which is based on practical tests performed in ERRI-B12. Assessments of endurable longitudinal compressive force for high-capacity trains in this document are required by the methodology of IRS 40421. IRS 40421 assesses operational train parameters.
This document applies to the following types of vehicles:
-   single wagons;
-   permanently coupled units with standard ends between the vehicles;
-   permanently coupled units with diagonal buffers and screw couplers between the vehicles;
-   permanently coupled units with a bar coupler between the vehicles;
-   articulated units with 2-axle bogies;
-   wagons with 3-axle bogies;
-   low-floor wagons with eight or more axles (e.g. rolling road wagon);
-   vehicles with centre couplers;
-   railbound construction and maintenance machines as defined in EN 14033-1:2017.
NOTE 2   This document defines the acceptance process to be followed by vehicles that are operated in a way that high longitudinal compressive force occur in the trains due to their operational environment (e.g. train composition, brake mode, track layout).
The following vehicles are not in the scope of this document:
-   locomotives and passenger rolling stocks;
-   vehicles that are only operated in passenger trains.
NOTE 3   Locomotives, passenger rolling stocks and vehicles operated in passenger trains only are not in the scope of this document as they either are subject to low longitudinal compressive force in operation or have sufficient endurable longitudinal compressive force due to their axle load.
Acceptance criteria and test conditions as well as conditions for simulation are defined in this document. Conditions for dispensation of the assessment of the endurable longitudinal compressive force are also defined in this document.
This document applies principally to vehicles which operate without restrictions on tracks with a gauge of 1 435 mm in Europe.
NOTE 4   The influence on railway systems using other gauges is not sufficiently understood to extend the scope of this document to gauges other than 1 435 mm.
NOTE 5   For wagons with centre couplers, a need for assessment of derailment risk due to Longitudinal Forces on other gauges (1 524 mm, 1 600 mm, 1 668 mm) has been expressed. The influence on railway systems using other gauges is not sufficiently understood. This document only introduces some notions to assess it independently from the gauge.

  • Standard
    39 pages
    English language
    e-Library read for
    1 day

This document specifies requirements and recommendations to maximize the sustainability of cabling systems including both customer premises infrastructure and the accommodation of information technology equipment by addressing the a) cabling design; b) selection, packaging and transportation of components and related materials; c) installation, operation and maintenance; d) management of waste materials; e) skill sets necessary for designers, installers and users.

  • Draft
    43 pages
    English language
    e-Library read for
    1 day

This document specifies the mounting dimensions required for interchangeability of rod-end spherical eyes of pneumatic cylinders. The rod-end spherical eyes have been designed specifically for the use with 1 000 kPa [10 bar1)] series cylinders manufactured in accordance with ISO 6432 and ISO 15552, but this does not limit their application. The spherical bearing end eyes are used on piston rods of pneumatic cylinders for mechanically transmitting the cylinder force under oscillatory rotational and tilting movements. The design of the rod-end spherical eyes is based on the maximum forces resulting from the specified internal diameter of the cylinders and pressure according to ISO 6432, ISO 15552 and ISO 21287. 1)1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    4 pages
    English language
    sale 15% off

This document specifies requirements for the required structure and content of security functional components for use during a security evaluation. It includes a catalogue of functional components that meet the common security functionality requirements of many IT products.

  • Standard
    262 pages
    English language
    e-Library read for
    1 day

This document specifies controls, purpose, and guidance for implementing controls, to meet the requirements identified by a risk and impact assessment related to the protection of personally identifiable information (PII).
In particular, this document specifies requirements and guidance based on ISO/IEC 27002, taking into consideration the controls for processing PII that can be applicable within the context of an organization's information security risk environment(s).
This document is applicable to all types and sizes of organizations acting as PII controllers (as defined in ISO/IEC 29100), including public and private companies, government entities and not-for-profit organizations that process PII, in particular, organizations that do not establish or operate a privacy information management system.

  • Standard
    55 pages
    English language
    e-Library read for
    1 day

This document specifies requirements and a standardized framework for specifying objective, repeatable and reproducible evaluation methods and evaluation activities.
This document does not specify how to evaluate, adopt, or maintain evaluation methods and evaluation activities. These aspects are a matter for those originating the evaluation methods and evaluation activities in their particular area of interest.

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

Loading...