This European Standard deals with the safety of stand-alone electric spin extractors, and pin extractors incorporated in washing machines that have separate containers for washing and spin extraction for household and similar purposes that have a capacity not exceeding 10 kg of dry cloth and a drum peripheral speed not exceeding 50 m/s, their rated voltages being not more than 250 V for single-phase appliances and 480 V for other appliances

  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric sewing machines for household and similar use, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances.

  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of - portable heated carpets; - heated carpets and similar appliances; - heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.

  • Draft
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of - portable heated carpets; - heated carpets and similar appliances; - heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.

  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62290‑1:2025 provides an introduction to the IEC 62290 series and deals with the main concepts, the system definition, the principles and the basic functions of UGTMS (urban guided transport management and command/control systems) for use in urban guided passenger transport lines and networks. This document is applicable for new lines or resignalling of existing lines. This document is applicable to applications using: - continuous data transmission, - continuous supervision of train movements by train protection profile, and - localisation of trains by onboard UGTMS equipment (reporting trains), and optionally by external wayside (and optionally onboard) device. The IEC 62290 series specifies the functional, system and interface requirements for the command, control, and management systems intended to be used on urban, guided passenger transport lines and networks. These systems are designated herein as urban guided transport management and command/control systems (UGTMS). UGTMS cover a wide range of operations needs from non-automated (GOA1) to unattended (GOA4) operation. A line may be equipped with UGTMS on its full length or only partly equipped. The IEC 62290 series does not specifically address security issues. However, aspects of safety requirements may apply to ensuring security within the urban guided transit system. The main objectives of this series are as follows: - to provide a baseline system description and functional requirements specification for a transport authority to use in a request for proposal, - to provide recommendations for those transport authorities wishing to acquire an interoperable or interchangeable system. It is the responsibility of the transport authority concerned to decide on how to apply the IEC 62290 series and to take into account their particular needs. This document is applicable to applications using: - continuous data transmission, - continuous supervision of train movements by train protection profile, and - localisation of trains by onboard UGTMS equipment (reporting trains), and optionally by external wayside (and optionally onboard) device. This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Figure 3, giving the system environment of UGTMS, has been amended to reflect the adaptation of it; b) external equipment for which no requirement is described in the IEC 62290 series has been removed; c) new external equipment having such requirements (like the washing machine) has been added.

  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric insect killers for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric sewing machines for household and similar use, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances that are within the scope of this standard are: amusement machines; tables; bowling machines; dartboards; driving simulators; gaming machines; kiddie rides; laser shooting appliances; pinball machines; video games; personal service machines; card re-value machines; currency dispensers; luggage lockers; weighing machines; shoe shining appliances. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by users and maintenance persons

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electrical recovery and/or recycle equipment to recover and/or recycle refrigerant from air conditioning and refrigeration equipment.

  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric insect killers for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.

  • Draft
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of stand-alone electric spin extractors, and pin extractors incorporated in washing machines that have separate containers for washing and spin extraction for household and similar purposes that have a capacity not exceeding 10 kg of dry cloth and a drum peripheral speed not exceeding 50 m/s, their rated voltages being not more than 250 V for single-phase appliances and 480 V for other appliances

  • Draft
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62290‑3:2025 specifies the system architecture for urban guided transport management and command/control systems (UGTMS) as defined in IEC 62290‑1 and IEC 62290‑2, and the allocation of functions and requirements defined in IEC 62290‑2 to the different UGTMS subsystems (designated as system constituents in IEC 62290‑1 and IEC 62290‑2), for use in urban guided passenger transport lines and networks. The IEC 62290 series specifies the functional, system and interface requirements for the command, control, and management systems intended to be used on urban, guided passenger transport lines and networks. These systems are designated herein as urban guided transport management and command/control systems (UGTMS). UGTMS cover a wide range of operations needs from non-automated (GOA1) to unattended (GOA4) operation. A line may be equipped with UGTMS on its full length or only partly equipped. The IEC 62290 series does not specifically address security issues. However, aspects of safety requirements may apply to ensuring security within the urban guided transit system. The main objectives of this series are as follows: * to provide a baseline system description and functional requirements specification for a transport authority to use in a request for proposal, * to provide recommendations for those transport authorities wishing to acquire an interoperable or interchangeable system. It is the responsibility of the transport authority concerned to decide on how to apply the IEC 62290 series and to take into account their particular needs. The IEC 62290 series is also intended to support applications for upgrading existing signalling and command control systems. In this case, interchangeability and compatibility could be ensured only for the additional UGTMS equipment. Checking the possibility for upgrading existing equipment and the level of interoperability is the responsibility of the transport authority concerned. This document is applicable for new lines or for upgrading existing signalling and command control systems. This document is applicable to applications using * continuous data transmission, * continuous supervision of train movements by train protection profile, and * localisation by onboard UGTMS equipment (reporting trains), and optionally by external wayside (and optionally onboard) device. The functional allocations of the UGTMS subsystems are mandatory (forming a sort of core system) or optional, according to the mandatory/optional functions and requirements defined in IEC 62290‑2. This document is applicable as a basis to define FIS and FFFIS. For specific applications, some elements can be added to meet the requirements coming from additional functions or equipment. This second edition cancels and replaces the first edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the last maintenance of IEC 62290‑1 is taken into account, in particular the changes made for describing the external environment of UGTMS; b) the last maintenance of IEC 62290‑2 is taken into account, as IEC 62290‑3 is using the requirements defined in the latter. Therefore, the document reflects the deleted functions and requirements in IEC 62290‑2, and also the new functions and requirements.

  • Draft
    280 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electrical recovery and/or recycle equipment to recover and/or recycle refrigerant from air conditioning and refrigeration equipment.

  • Draft
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-3-202:2025 provides performance test methods specialized for the thermal and electrical characteristics of an energy management system to effectively share the heat and power of networked small stationary fuel cell power systems. These test methods are applied for each small stationary fuel cell power system. This document covers small stationary fuel cell power systems which can be complemented with a supplementary heat generator or a thermal storage system, or both, such as: - output: rated electric power output of less than 10 kW for each system; - output mode: grid-connected or independent operation or stand-alone operation with alternating current (AC) output not exceeding 240 V or direct current (DC) output; - operating pressure: maximum allowable working pressure of less than 0,1 MPa (G) for the fuel and oxidant passages; - fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen) or liquid fuel (kerosene, methanol); oxidant: air. This document does not apply to small stationary fuel cell power systems with electricity storage other than (small scale) back-up power for safety, monitoring and control.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-11:2025 applies to electrically-operated food preparation appliances, either in the form of separate machines with a single function or in the form of multi-purpose machines with appropriate tools or attachments for several functions. These machines are intended for placing on counters, tables, work tops or sinks, for built-in, or for hand-held use, supplied from mains or from batteries and able to ensure the functions described in IEC 60619:1993, Clause 4 and IEC 60619:1993/AMD1:1995, Clause 4. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) definition of various kind of food preparation appliances added; b) revision of the test conditions; c) coffee mills and coffee grinders are removed from the scope. This Part 2-11 is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63185:2025 relates to a measurement method for complex permittivity of dielectric substrates at microwave and millimeter-wave frequencies. This method has been developed to evaluate the dielectric properties of low-loss materials used in microwave and millimeter-wave circuits and devices. It uses higher-order modes of a balanced-type circular disk resonator and provides broadband measurements of dielectric substrates by using one resonator, where the effect of excitation holes and that of fringing fields are taken into account accurately on the basis of the mode-matching analysis. This second edition cancels and replaces the first edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the upper limit of the applicable frequency range has been extended from 110 GHz to 170 GHz; b) circular disk resonators used for the measurements now include one with waveguide interfaces; c) in calculating the complex permittivity from the measured resonant properties, the fringing fields are now accurately taken into account based on the mode-matching analysis.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for cable management systems (CMS) intended to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions. This document establishes a non-hierarchical classification for this ability. Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document. CMS intended to provide support and fire protection for cables are tested according to EN 1366-11. This document does not apply to powertrack systems. NOTE Rules for testing CMS-support for fibre optic cables according to EN 50582 and communication cables according to EN 50289-4-16 are under consideration.

  • Technical specification
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62037-8:2025 defines a radiated passive intermodulation (PIM) test to determine PIM levels generated by a device or object when it is exposed to RF radiation. This test can be conducted on any material or object and is not limited to devices designed to propagate RF signals. This test can be conducted as either a near field or far field test as defined by the test specification in an outdoor test site or in an anechoic test chamber. This second edition cancels and replaces the first edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) added safety warning to verify that transmitters are switched off before connecting or disconnecting any component; b) corrected formula for calculating directivity; c) corrected antenna orientation labels in Figure 6; d) added clarification that PIM tests reports shall include maximum PIM and VSWR values.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61753-084-02:2025 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 980/1 550 nm wide wavelength division multiplexing (WWDM) device will satisfy in order to be categorized as meeting the requirements of category C (indoor controlled environment), as defined in IEC 61753-1:2018, Annex A. WWDM is defined in IEC 62074-1. The requirements cover devices with single-mode non‑connectorised pigtails. This device has three ports; 980 nm port, 1 550 nm port and common port for output or combining 980 nm and 1 550 nm. This first edition cancels and replaces the first edition of IEC 61753-084-2 published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Change of test conditions harmonizing with IEC 61753-1: 2018.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61400-15-1:2025 defines a framework for assessment and reporting of the wind turbine suitability conditions for both onshore and offshore wind power plants. This includes: a) definition, measurement, and prediction of the long-term meteorological and wind flow characteristics at the site; b) integration of the long-term meteorological and wind flow characteristics with wind turbine and balance-of-plant characteristics; c) characterizing environmental extremes and other relevant plant design drivers; d) addressing documentation and reporting requirements to help ensure the traceability of the assessment processes. This document is framed to complement and support the scope of related IEC 61400 series by defining environmental input conditions. It is not intended to supersede the design and suitability requirements presented in those documents. Specific analytical and modelling procedures as described in IEC 61400-1, IEC 61400-2, IEC 61400-3-1 and IEC TS 61400-3-2 are excluded from the scope of this document.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62037-3:2025 defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector, as independently as possible from the effects of cable passive intermodulation (PIM). For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate transmission line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses on the connectors, a series of impacts is applied to the connectors while measuring the PIM. This third edition cancels and replaces the second edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) impact test requirements for multi-channel connectors added; b) method for calculating impact energy added for connector shapes other than round; c) revised test considerations for achieving maximum PIM in reverse (reflected) PIM measurements; d) added clarification that PIM tests reports shall include the maximum PIM value measured.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61340-4-11:2025 specifies the electrostatic testing, design and safe use requirements for composite intermediate bulk containers (IBC) intended for use in hazardous areas. Composite IBC are often filled with flammable liquids which can create an explosive atmosphere in the inner receptacle. The design requirements for composite IBC intended for such use are defined in 7.3.4.5 of IEC TS 60079-32-1:2013. The test procedures described in this document can be used by manufacturers, suppliers and product users for product qualification and compliance verification of new and reconditioned composite IBC. Additionally, the requirements of this document can be used for testing the electrostatic properties of composite IBC, independent of any inspection periods. Precautions regarding the use of composite IBC (e.g., stirring, cleaning etc.) are defined in 7.3.4.5 of IEC TS 60079-32-1:2013. Compliance with the requirements of this document does not mitigate the need for full risk assessment.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides design-for-recycling guidelines for Polyvinyl Chloride (PVC) cable management products and recommends design options to ensure the product is recyclable. This document is limited to the recycling of PVC cable management products. NOTE 1 The following PVC containing products are considered as examples: - Conduits and fittings; - Liquid tight sheathing and fittings; - Cable trunking and cable ducting lengths and other system components; - Cable tray and cable ladder lengths and other system components; - Cable cleats; - Cable glands; - Cable ties; - Cover plates and cover tapes; - Articulated and flexible system components. Products associated with or incorporated in a PVC cable management system component but which are not system components (e.g. enclosures, connecting boxes) are not within the scope of this document. NOTE 2 Cable management products are generally subject to European Standards specifying requirements and tests to ensure adequate safety and appropriate performance. NOTE 3 Packaging of cable management products is not covered by this document.

  • Technical specification
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines methodologies to measure the energy consumption and productivity of coffee machines based on their characteristics. This document applies to professional and commercial coffee machines used, for example, in kitchens and food preparation areas in restaurants, canteens, hotels, coffee shops, breakfast rooms. This document does not apply to: - household appliances; - machines that use only coffee pods or coffee capsules; - machines powered by non-electrical energy (i.e. gas); - vending machines for hot beverages; - milk refrigerators integrated or not into traditional machines; - accessory equipment provided together with the machine (e.g. cup warmer, milk refrigerator) physically separated from the machine.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-2: 2025 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges from operators directly and from personnel to adjacent objects. It additionally specifies ranges of test levels which relate to different environmental, and installation conditions and establishes test procedures. The objective of this document is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which can occur from personnel to objects near the equipment. This document specifies: - ideal waveform of the discharge current; - range of test levels; - test equipment; - test setup; - test procedure; - calibration procedure; - measurement uncertainty. This document gives specifications for tests performed in laboratories and guidance to post-installation tests. This document is not intended to specify the tests to be applied to particular apparatus or systems. The main aim is to give a general basic reference to all concerned product committees. The product committees remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. This document excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging. It is not intended for use in characterizing the performance of ESD protection circuit IEC Guide 107. This document forms Part 4-2 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) added a calibration requirement for ESD generators with air discharge tip; b) added a normative annex for test setups for particular kind of equipment (see Annex I); c) added an informative annex for wearable devices (see Annex J); d) added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E); e) moved Clause 9 into a new informative annex (see Annex K); f) improvement of the current calibration procedure; g) improvement of the measurement uncertainty considerations with examples of uncertainty budgets; h) because post-installation tests cannot be performed in a controlled environment, this test method has been moved into a new informative Annex G.

  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62276:2025 applies to the manufacture of synthetic quartz, lithium niobate (LN), lithium tantalate (LT), lithium tetraborate (LBO), and lanthanum gallium silicate (LGS) single crystal wafers intended for use as substrates in the manufacture of surface acoustic wave (SAW) filters and resonators. This edition includes the following significant technical changes with respect to the previous edition: a) The terms and definitions, the technical requirements, sampling frequency, test methods and measurement of transmittance, lightness, colour difference for LN and LT have been added in order to meet the needs of industry development; b) The term “inclusion” (mentioned in 4.13 and 6.10) and its definition have been added because there was no definition for it in Clause 3; c) The specification of LTV and PLTV, and the corresponding description of sampling frequency for LN and LT have been added, because they are the key performance parameters for the wafers; d) The tolerance of Curie temperature specification for LN and LT have been added in order to meet the development requirements of the industry; e) Measurement of thickness, TV5, TTV, LTV and PLTV have been completed, including measurement principle and method of thickness, TV5, TTV, LTV and PLTV.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-7-2:2025 applies to SOFC cell/stack assembly units, testing systems, instruments and measuring methods, and specifies test methods to test the performance of SOFC cells and stacks. This document is not applicable to small button cells that are designed for SOFC material testing and provide no practical means of fuel utilization measurement. This document is used based on the recommendation of the entity that provides the cell performance specification or for acquiring data on a cell or stack in order to estimate the performance of a system based on it. Users of this document can selectively execute test items suitable for their purposes from those described in this document.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document a) addresses the support of safety extra low voltage (SELV) and limited power source (LPS) applications that provide remote power over: • 4-pair balanced cabling in accordance with the reference implementations of EN 50173 series using currents per conductor of up to 500 mA; • 1-pair balanced cabling using currents per conductor of up to 2 000 mA; and targets the support of applications that provide remote power over balanced cabling to terminal equipment, b) covers the transmission and electrical parameters needed to support remote power over balanced cabling, c) covers various installation scenarios and how these may impact the capability of balanced cabling to support remote powering, d) specifies design and configuration of cabling as specified in EN 50173-1. NOTE SELV requirements specify a maximum voltage of 60 V DC and LPS is understood in the applications referenced to be up to 100 W supplied within cabling. This document includes a mathematical model to predict the behaviour of different bundle sizes, various cabling constructions, and installation conditions for different current capacities.

  • Technical specification
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61753-086-02:2025 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1 490/1 550 nm downstream and 1 310 nm upstream wide wavelength division multiplexing (WWDM) passive optical network (PON) device will satisfy in order to be categorized as meeting the requirements of category C (indoor controlled environment), as defined in IEC 61753-1:2018, Annex A. WWDM is defined in IEC 62074-1. Annex B gives general information for these PON WWDM devices. This first edition cancels and replaces the first edition of IEC 61753-086-2 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Change of test conditions harmonizing with IEC 61753-1: 2018.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-5-1:2024 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V AC (at a frequency not exceeding 1 000 Hz) or 600 V DC. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of the scope structure and exclusions; b) requirements for control circuits; c) update of the normal service conditions (e.g. shock and vibration); d) update of information and marking requirements including environmental information requirements referencing IEC TS 63058:2021; e) update of the constructional requirements and the corresponding tests considering safety aspects (e.g. artificial optical radiation, security aspects, limited energy source, stored charge energy circuit); f) update of the EMC requirements according to the generic documents; g) new requirements for reed contact magnetic switches in Annex D; h) requirements for class II circuit devices achieved by double or reinforced insulation in Annex F; i) update of pull-out tests in Annex G; j) information requirements for audible signalling device in Annex J; k) insertion of new Annex O.

  • Standard
    136 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60794-1-307:2025 describes test procedures used in establishing uniform requirements of tubes for the mechanical property kinking. This document applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. Throughout the document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This first edition partially cancels and replaces the second edition of IEC 60794‑1-23 published in 2019. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to IEC 60794‑1‑23:2019: a) renumbering of the existing test method G7 as G7A; b) addition of test parameter L and calculated loop diameter D in Table 1 for method G7A; c) addition of a new test procedure for tubes routed within installation devices and numbering it as G7B.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60601-2-68:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-ray based IMAGE-GUIDED RADIOTHERAPY equipment for use with EXTERNAL BEAM EQUIPMENT (EBE). This document covers safety aspects of kilovoltage (kV) and megavoltage (MV) X-ray imaging devices integrated in a specified geometrical relationship with EBE for the purpose of IGRT. It covers aspects of communication and relationships between the EXTERNAL BEAM EQUIPMENT and X-ray imaging devices, attached or not directly attached to, but in the same RADIATION shielded area as, and dedicated for use only with, the EXTERNAL BEAM EQUIPMENT. This document deals with equipment for OFFLINE X-IGRT, ONLINE X-IGRT and REAL-TIME X-IGRT. It covers procedures to reduce the risk of over-reliance on the X-IGRT EBE SYSTEM. For example, in the case of ONLINE X-IGRT, the MANUFACTURER will provide an interactive interface for user interaction with the correction suggested by the system. This document does not apply to CT SCANNERS, X-RAY EQUIPMENT for RADIOGRAPHY, and X-RAY EQUIPMENT for RADIOSCOPY, which are not intended for use for IGRT. Requirements that are being tested according to another standard can be identified by the manufacturer and if equivalent do not require retesting, instead evidence can refer to the CT SCANNER, X-RAY EQUIPMENT for RADIOGRAPHY, or X-RAY EQUIPMENT for RADIOSCOPY EQUIPMENT manufacturer's providing compliance statements or test reports. If the X-IGRT EQUIPMENT is combined with an MEE, any requirement that is the same for the X-IGRT EQUIPMENT and the MEE, such as a PATIENT POSITIONER, is not required to be tested twice, but can be accepted as tested by the MEE. This document applies for X-ray equipment for radiography, radioscopy, and COMPUTER tomography used for IGRT. If a clause or subclause is specifically intended to be applicable to X-IGRT EBE SYSTEMS, the content of that clause or subclause will say so. Where that is not the case, the clause or subclause applies only to X-IGRT EQUIPMENT. This document, with the inclusion of TYPE TESTS and SITE TESTS, applies respectively to the MANUFACTURER and some installation aspects of X-IGRT EBE SYSTEMS intended to be: • for NORMAL USE, operated under the authority of the RESPONSIBLE ORGANIZATION by QUALIFIED PERSONS having the required skills for a particular medical application, for particular specified clinical purposes, e.g., STATIONARY RADIOTHERAPY or MOVING BEAM RADIOTHERAPY, • maintained in accordance with the recommendations given in the INSTRUCTIONS FOR USE, and • subject to regular quality assurance performance and calibration checks by a QUALIFIED PERSON. IEC 80601-2-68:2024 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with the new editions of the relevant standards: – IEC 60601-2-1:2020; – IEC 60601-2-44:2009, IEC 60601-2-44:2009/AMD1:2012 and IEC 60601-2-44:2009/AMD2:2016; – IEC 60601-2-64:2014; b) clarification of the use of IEC 60601-2-68 for CT SCANNERS, X-RAY EQUIPMENT for RADIOGRAPHY and RADIOSCOPY used in the same room with an EXTERNAL BEAM EQUIPMENT (EBE); c) introduction of updated requirements related to MECHANICAL HAZARDS, RADIATION HAZARDS, PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS), ACCOMPANYING DOCUMENTATION of an ME SYSTEM, and REMOTE OPERATION.

  • Standard
    79 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62541-15:2025 describes a safety communication layer (services and a protocol) for the exchange of SafetyData using IEC 62541 mechanisms. It identifies the principles for functional safety communications defined in IEC 61784‑3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only. NOTE 1 This document targets controller-to-controller communication. However, easy expandability to other use-cases (e.g. OPC UA field level communication) has already been considered in the design of this document. NOTE 2 This document does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres. This document defines mechanisms for the transmission of safety-relevant messages among participants within a network using OPC UA technology in accordance with the requirements of the IEC 61508 series and IEC 61784-3 for functional safety. These mechanisms can be used in various industrial applications such as process control, manufacturing, automation, and machinery. This document provides guidelines for both developers and assessors of compliant devices and systems. NOTE 3 The resulting SIL claim of a system depends on the implementation of this document within the system – implementation of this document in a standard device is not sufficient to qualify it as a safety device.

  • Draft
    93 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-36:2025 is used for testing all kinds of relays and evaluates their ability to perform under expected conditions of transportation, storage, and all aspects of operational use. This document defines a standard test method to measure fire hazards of all materials susceptible to fire hazards.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard covers the requirements for phase-shifting transformers of all types. The scope excludes transformers with an unregulated phase shift. This document is limited to matters particular to phase-shifting transformers and does not include matters relating to general requirements for power transformers covered in existing standards in the EN 60076 series.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-25:2025 Used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method to check the magnetic interference between relays under operating conditions and their influence on other relays in the neighbourhood.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62902:2025 specifies methods for the clear identification of secondary cells, batteries, battery modules and monoblocs according to their chemistry (electrochemical storage technology). The markings described in this document are applicable to - secondary cells, - batteries, - battery modules, and - monoblocs, when they are placed on the market for end use and when their battery volume exceeds 900 cm3. The chemistry marking is useful for the installation, operation and decommissioning phases in the battery's life cycle. This document defines the conditions of use of the markings indicating the chemistry of these secondary batteries.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This part of the IEC 60255 series specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. It is applicable to measuring relays and protection equipment and combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. Tests specified in this document are not required for equipment not incorporating electronic circuits, for example electromechanical relays. The requirements specified in this document are applicable to measuring relays and protection equipment in a condition representative of how new equipment is provided by the manufacturer. All tests specified are type tests only. 1.2 Emission This document specifies limits and test methods, for measuring relays and protection equipment in relation to electromagnetic emissions which might cause interference in other equipment. These emission limits represent electromagnetic compatibility requirements and have been selected to ensure that the disturbances generated by measuring relays and protection equipment, operated normally in substations and power plants, do not exceed a specified level which could prevent other equipment from operating as intended. Test requirements are specified for the enclosure, auxiliary power supply ports, input/output ports, signal/control ports and wired network ports. 1.3 Immunity This document specifies the immunity test requirements for measuring relays and protection equipment in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges. These test requirements represent the electromagnetic compatibility immunity requirements and have been selected so as to ensure an adequate level of immunity for measuring relays and protection equipment, operated normally in substations and power plants. NOTE 1 Product safety considerations are not covered in this document. NOTE 2 In special cases, situations will arise where the levels of disturbance could exceed the levels specified in this document, for example where a hand-held transmitter or a mobile telephone is used close to measuring relays and protection equipment. In these instances, special precautions and procedures could have to be employed.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-39:2025 is used for testing all kind of relays and shall evaluate their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines standard test methods for: 1. measuring the insertion and withdrawal forces of the mating relay and socket; 2. measuring the insertion and withdrawal forces on relays with flat quickconnect terminations; 3. verifying the correct connection of flat terminals with eye lug connectors.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62933-4-2:2025 defines the requirements for evaluating and reporting the negative impact on the environment caused by the failure of a cell, flow cell, battery or flow battery in the accumulation subsystem of a battery energy storage system (BESS). The batteries within this scope used in a BESS are classified according to the type of their electrolyte. These electrolyte types are aqueous, non-aqueous or solid. The environmental impacts directly caused by the failure of other components of the BESS are not within the scope of this document.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62037-1:2025 deals with the general requirements and measuring methods for intermodulation (IM) level measurement of passive RF and microwave components, which can be caused by the presence of two or more transmitting signals. The test procedures given in this document give the general requirements and measurement methods required to characterize the level of unwanted IM signals using two transmitting signals. The IEC 62037 series addresses the measurement of PIM but does not cover the long-term reliability of a product with reference to its performance. This third edition cancels and replaces the second edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) added clarification that PIM generation is typically frequency dependent and noted that testing with swept or multiple fixed frequencies often provides more accurate results; b) identified multi-port PIM analyzers as a possible test set-up topography; c) added specification that test power level does not exceed the power handling capability of the DUT; d) updated test specification to include missing parameters needed to properly define a PIM test; e) added clarification that PIM test reports include the maximum PIM value measured over the test duration; f) corrected error in Figure 3 that was erroneously changed in IEC 62037-1:2021.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard covers the requirements for phase-shifting transformers of all types. The scope excludes transformers with an unregulated phase shift. This document is limited to matters particular to phase-shifting transformers and does not include matters relating to general requirements for power transformers covered in existing standards in the EN 60076 series.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60255-27:2023 specifies the product safety requirements for measuring relays and protection equipment having a rated AC voltage up to 1 000 V, or a rated DC voltage up to 1 500 V. This document specifies essential safety requirements to minimize the risk of fire and hazards caused by electric shock or injury to the user and property. This document specifies only product safety requirements; functional performance of the equipment is not covered. This document covers all the ways in which the equipment can be mounted and used in cabinets, racks and panels. This document also applies to auxiliary devices such as shunts, series resistors, transformers, auxiliary control panels, display devices, etc., that are used in conjunction with measuring relays and protection equipment and are tested together.

  • Standard
    103 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The scope of this document is the definition of the functional interface between TDC and DMIs. [Figure 1] The DMIs are those defined and considered in CLC/TR 50542 1:2025. The TDC is defined in CLC/TR 50542 1:2025. NOTE 1 The conversion of physical signals into numerical representation is out of scope. NOTE 2 The term DMI is used in this clause as synonym for display.

  • Technical report
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-6:2025 is used for testing all kinds of relays and evaluates their ability to perform under expected conditions of transportation, storage, and all aspects of operational use. This document defines a standard test method to measure contact-circuit resistance or voltage drop.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day