Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-201: Particular requirements for control equipment

This clause of Part 1 is applicable, except as follows.
1.1.1 Equipment included in scope
Replacement:
This part of IEC 61010 specifies safety requirements and related verification tests for control equipment and/or their associated peripherals.
Some equipment examples are:
- programmable logic controller (PLC);
- programmable automation controller (PAC);
- distributed control systems (DCS);
- industrial PC (computers) and panel PC;
- programming and debugging tools (PADTs);
- displays and human-machine interfaces (HMI);
- any product performing the function of control equipment and/or their associated peripherals;
- positioners; and
- control equipment which have as their intended use the command and control of machines, automated manufacturing and industrial processes, e.g. discrete and continuous control.
Components of the above named equipment and in the scope of this standard are e.g.:
- (auxiliary) stand-alone power supplies;
- peripherals such as digital and analogue I/O,
- remote-I/O;
- industrial network equipment, embedded or standalone (e.g. switches, routers, wireless base station).
Control equipment and their associated peripherals are intended to be used in an industrial environment and may be provided as OPEN or ENCLOSED EQUIPMENT.
NOTE 1 Control equipment intended also for use in other environments or for other purposes (example: for use in building installations to control light or other electrical installations, or for use on cars, trains or ships) can have additional conformity requirements defined by the safety standard(s) for these applications. These requirements can involve as example: insulation, spacings and power restrictions.
NOTE 2 Computing devices and similar equipment within the scope of IEC 60950 (planned to be replaced by IEC 62368) and conforming to its requirements are considered to be suitable for use with control equipment within the scope of this standard. However, some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in IEC 61010-1:2010, 5.4.4 second paragraph.
Control equipment covered in this standard is typically intended 237 for use in OVERVOLTAGE CATEGORY II (IEC 60664-1) in low-voltage installations, where the RATED equipment supply voltage does not exceed AC. 1 000 V r.m.s. (50/60 Hz), or DC 1 000 V.
Where control equipment is intended for installation to supply systems with overvoltage category III or IV, additional requirements are identified in Annex K.
The requirements of ISO/IEC Guide 51 and IEC Guide 104, as they relate to this part of IEC 61010, are incorporated herein.
1.1.2 Equipment excluded from scope
Replacement:
This standard does not deal with aspects of the overall automated system, e.g. a complete assembly line. Control equipment (e.g. DCS and PLC), their application program and their associated peripherals are considered as components (components in this context are items which perform no useful function by themselves) of an overall automated system.
Since control equipment (e.g. DCS and PLC) are component devices, safety considerations for the overall automated system including installation and application are beyond the scope of this standard. Refer to IEC 60364 series of standards or applicable national/local regulations for electrical installation and guidelines.
1.2.1 Aspects included in scope
Replace first sentence:
The purpose of the requirements of this standard is to ensure that all HAZARDs to the OPERATOR, SERVICE PERSONNEL and the surrounding area are reduced to a tolerable level.
NOTE By using the terms "OPERATOR" and "SERVICE PERSONNEL" this standard considers the perception of HAZARDS depending on training and skills. Annex AA gives a general approach in this regard.
1.2.2 Aspects excluded from scope
Replacement:
This standard does not cover:
a)[...]
b)[...]
c)[...]
d)[...]
e)[...]

Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2-201: Besondere Anforderungen für Steuer- und Regelgeräte

Exigences de securité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-201: Exigences particulières pour les équipements de commande

L'IEC 61010-2-201:2024 complète ou modifie les articles correspondants de l'IEC 61010-1, de façon à transformer cette publication en norme IEC: Exigences particulières pour les équipements de commande. Le présent document doit être utilisé conjointement avec l'IEC 61010-1:2010 et l'IEC 61010 1:2010/AMD1:2016. Lorsqu'un paragraphe particulier de l'IEC 61010-1 n'est pas mentionné dans le présent document, ce paragraphe s'applique pour autant que cela soit raisonnable. Lorsque le présent document mentionne "addition", "modification", "remplacement" ou "suppression", il convient d'adapter l'exigence, la spécification d'essai ou la note correspondante de l'IEC 61010 1 en conséquence.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
a) 1.1.1: clarification concernant les équipements inclus dans le domaine d'application;
b) 4.3.2.101: suppression du module à fibre optique;
c) 5.4.3: clarification de l'installation de l'équipement;
d) 6.7.1.1: révision de la figure représentant l'isolation entre des circuits séparés;
e) 6.7.101: suppression du paragraphe concernant l'isolation des BORNES A CABLER SUR PLACE de CATEGORIE DE SURTENSION ll avec une tension nominale maximale de 1 000 V;
f) 6.7.1.101: ajout d'un nouveau paragraphe concernant l'isolation des CIRCUITS TBTS/TBTP;
g) 6.8.3: ajout d'une spécification pour le contrôleur de tension;
h) 6.9.3: ajout d'une exception supplémentaire pour le codage des couleurs;
i) 6.9.101: ajout d'un nouveau paragraphe concernant le câblage des circuits secondaires, par exemple TBTS/TBTP;
j) 8.2.2.101: ajout d'exigences supplémentaires pour les écrans en verre;
k) 8.3: suppression du paragraphe concernant l'essai de chute;
l) 9.3.2: ajout d'exigences supplémentaires pour les matériaux des connecteurs et les matériaux isolants;
m) clarification des exigences particulières relatives aux matériaux non métalliques;
n) Article 11: suppression des exigences particulières concernant la protection contre les DANGERS des fluides et des corps solides étrangers;
o) 12.4: ajout d'un paragraphe supplémentaire concernant le rayonnement hyperfréquence;
p) 14.102: clarification concernant la description des appareils de commutation.

Varnostne zahteve za električno opremo za meritve, nadzor in laboratorijsko uporabo - 2-201. del: Posebne zahteve za opremo za nadzor in upravljanje

General Information

Status
Not Published
Public Enquiry End Date
22-Nov-2020
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
28-May-2024
Due Date
16-Jul-2024
Completion Date
01-Jul-2024

Relations

Buy Standard

Draft
prEN IEC 61010-2-201:2020 - BARVE
English language
80 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 61010-2-201:2020
01-november-2020
Varnostne zahteve za električno opremo za meritve, nadzor in laboratorijsko
uporabo - 2-201. del: Posebne zahteve za opremo za nadzor in upravljanje
Safety requirements for electrical equipment for measurement, control, and laboratory
use - Part 2-201: Particular requirements for control equipment
Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2
-201: Besondere Anforderungen für Steuer- und Regelgeräte
Exigences de securité pour appareils électriques de mesurage, de
régulation et de laboratoire - Partie 2-201: Exigences particulières pour
les équipements de commande
Ta slovenski standard je istoveten z: prEN IEC 61010-2-201:2020
ICS:
19.080 Električno in elektronsko Electrical and electronic
preskušanje testing
71.040.10 Kemijski laboratoriji. Chemical laboratories.
Laboratorijska oprema Laboratory equipment
oSIST prEN IEC 61010-2-201:2020 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 61010-2-201:2020

oSIST prEN IEC 61010-2-201:2020
65/822/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61010-2-201 ED3
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2020-09-04 2020-11-27
SUPERSEDES DOCUMENTS:
65/782/CD, 65/798A/CC
IEC TC 65 : INDUSTRIAL-PROCESS MEASUREMENT, CONTROL AND AUTOMATION
SECRETARIAT: SECRETARY:
France Mr Rudy BELLIARDI
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

TC 66
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY

SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.

TITLE:
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part
2-201: Particular requirements for control equipment

PROPOSED STABILITY DATE: 2026
NOTE FROM TC/SC OFFICERS:
elect ronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

oSIST prEN IEC 61010-2-201:2020
65/822/CDV – 2 – IEC CDV 61010-2-201:2020 © IEC 2020
1 CONTENTS
2 CONTENTS . 2
3 FOREWORD . 4
4 INTRODUCTION . 7
5 1 Scope and object . 8
6 2 Normative references . 9
7 3 Terms and definitions . 10
8 4 Tests . 12
9 5 Marking and documentation . 13
10 6 Protection against electric shock . 15
11 7 Protection against mechanical HAZARDS . 30
12 8 Resistance to mechanical stresses . 31
13 9 Protection against the spread of fire . 32
14 10 Equipment temperature limits and resistance to heat . 37
15 11 Protection against HAZARDS from fluids and solid foreign objects . 44
16 12 Protection against radiation, including laser sources, and against sonic and
17 ultrasonic pressure . 44
18 13 Protection against liberated gases and substances, explosion and implosion . 44
19 14 Components and subassemblies . 44
20 15 Protection by interlocks . 48
21 16 HAZARDS resulting from application . 48
22 17 RISK assessment . 49
23 Annexes . 50
24 Annex E (informative) Guideline for reduction of POLLUTION DEGREES . 51
25 Annex F (normative) ROUTINE TESTS . 53
26 Annex L (informative) Index of defined terms . 55
27 Annex AA (informative) General approach to safety for control equipment . 56
28 Annex BB (informative) System drawing of isolation boundaries . 58
29 Annex CC (informative) Historical techniques for secondary circuits . 69
30 Annex DD (normative) Flammability test for magnesium alloy fire ENCLOSUREs or
31 flame barriers (see 9.3.2) . 73
32 Annex EE (informative) Information/documentation and correlation to its uses . 74
33 Annex FF (informative) Measurement of CLEARANCES and CREEPAGE DISTANCES . 76
34 Bibliography . 79
36 Figure 101 – Typical INTERFACE/PORT/TERMINAL diagram of control equipment . 18
37 Figure 102 – Examples of insulation between separate circuits and between circuits
38 and ACCESSIBLE conductive parts . 23
39 Figure 103 – Mechanical HAZARDS, with regard to PANEL MOUNTED EQUIPMENT . 30
40 Figure 104 – Spread of fire HAZARDS, with regard to PANEL MOUNTED EQUIPMENT . 34
41 Figure 105 – General temperature test environment . 39
42 Figure 106 – Vented equipment . 41
43 Figure 107 – Non-vented equipment . 42

oSIST prEN IEC 61010-2-201:2020
IEC 61010-2-201:2020 © IEC 2020 – 3 – 65/822/CDV
44 Figure 108 – PANEL MOUNTED EQUIPMENT extending through the wall of the end location
45 ENCLOSURE . 43
46 Figure AA.1 – Control equipment access and safety concerns . 56
47 Figure BB.1 – Typical system ENCLOSURE layout . 58
48 Figure BB.2 – Simplified system schematic . 60
49 Figure BB.3 – HAZARD situation of the control equipment . 61
50 Figure BB.4 – Application of the standard to the control equipment safety drawing . 62
51 Figure BB.5 – Application of 6.7.1.5 items a) and b) to the control equipment safety
52 drawing . 62
53 Figure BB.6 – Application of 6.7.1.5 items a), b), c) and d) to the control equipment
54 safety drawing . 63
55 Figure BB.7 – REINFORCED INSULATION . 63
56 Figure BB.8 – BASIC INSULATION . 64
57 Figure BB.9 – REINFORCED INSULATION, BASIC INSULATION and impedance . 65
58 Figure BB.10 – REINFORCED INSULATION from external power supplies . 66
59 Figure BB.11 – BASIC INSULATION from external power supplies . 67
60 Figure EE.1 – Information/documentation for component products . 74
61 Figure EE.2 – Information/documentation accumulation and segregation tree for an
62 example installation . 75
63 Figure FF.1 – The path a component mounted to a PWB (side view). 77
64 Figure FF.2 – The path a component mounted to a PWB (side view). 77
66 Table 101 – INTERFACES, PORTS AND TERMINALS considered as OPERATOR ACCESSIBLE
67 for OPEN and ENCLOSED EQUIPMENT . 17
68 Table 4 – CLEARANCE and CREEPAGE DISTANCES for MAINS CIRCUITs of OVERVOLTAGE
69 CATEGORY II up to 300 V. 26
70 Table 5 – Test voltages for solid insulation between MAINS and between MAINS and
71 secondary circuits OVERVOLTAGE CATEGORY II up to 300 V . 27
72 Table 6 – CLEARANCES and test voltages for secondary circuits derived from MAINS
73 s of OVERVOLTAGE CATEGORY II up to 300 V . 28
CIRCUIT
74 Table 19 – Surface temperature limits, under NORMAL CONDITION . 38
75 Table E.1 – Environmental situations . 51
76 Table E.2 – Reduction of POLLUTION DEGREES (PD) . 52
77 Table CC.1 – Limits of output current and output power for inherently limited power
78 sources . 71
79 Table CC.2 – Limits of output current, output power and RATINGS for over-current
80 protective devices for non-inherently limited power sources . 72
81 Table FF.1 – Dimensions of X . 76
oSIST prEN IEC 61010-2-201:2020
65/822/CDV – 4 – IEC CDV 61010-2-201:2020 © IEC 2020
84 INTERNATIONAL ELECTROTECHNICAL COMMISSION
85 ____________
87 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT
88 FOR MEASUREMENT, CONTROL, AND LABORATORY USE –
90 Part 2-201: Particular requirements for control equipment
92 FOREWORD
93 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
94 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
95 international co-operation on all questions concerning standardization in the electrical and electronic fields. To
96 this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
97 Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
98 Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
99 in the subject dealt with may participate in this preparatory work. International, governmental and non-
100 governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
101 with the International Organization for Standardization (ISO) in accordance with conditions determined by
102 agreement between the two organizations.
103 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
104 consensus of opinion on the relevant subjects since each technical committee has representation from all
105 interested IEC National Committees.
106 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
107 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
108 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
109 misinterpretation by any end user.
110 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
111 transparently to the maximum extent possible in their national and regional publications. Any divergence
112 between any IEC Publication and the corresponding national or region
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.