Equipment for general lighting purposes - EMC immunity requirements

Applies to lighting equipment which is within the scope of IEC technical committee 34, such as lamps, auxiliaries and luminaires, intended either for connecting to a low voltage electricity supply or for battery operation.

Einrichtung für allgemeine Beleuchtungszwecke - EMV-Störfestigkeitsanforderungen

Equipements pour l'éclairage à usage général - Prescriptions concernant l'immunité CEM

S'applique aux équipements d'éclairage du domaine d'activité du comité d'études 34 de la CEI, tels que les lampes, les accessoires et les luminaires, destinés à être raccordés au réseau d'alimentation électrique public basse tension, ou à fonctionner sur piles.

Equipment for general lighting purposes - EMC immunity requirements (IEC 1547:1995)

General Information

Status
Withdrawn
Publication Date
31-May-1996
Withdrawal Date
17-Aug-2009
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
12-Aug-2009
Due Date
04-Sep-2009
Completion Date
18-Aug-2009

Relations

Buy Standard

Standard
EN 61547:1996
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61547:1996
01-junij-1996
Equipment for general lighting purposes - EMC immunity requirements (IEC
1547:1995)
Equipment for general lighting purposes - EMC immunity requirements
Einrichtung für allgemeine Beleuchtungszwecke - EMV-Störfestigkeitsanforderungen
Equipements pour l'éclairage à usage général - Prescriptions concernant l'immunité
CEM
Ta slovenski standard je istoveten z: EN 61547:1995
ICS:
29.140.01 Žarnice na splošno Lamps in general
33.100.20 Imunost Immunity
SIST EN 61547:1996 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61547:1996

---------------------- Page: 2 ----------------------

SIST EN 61547:1996

---------------------- Page: 3 ----------------------

SIST EN 61547:1996

---------------------- Page: 4 ----------------------

SIST EN 61547:1996

---------------------- Page: 5 ----------------------

SIST EN 61547:1996

---------------------- Page: 6 ----------------------

SIST EN 61547:1996
NORME CEI
INTERNATIONALE IEC
1547
INTERNATIONAL
Première édition
STANDARD
First edition
1995-09
Equipements pour l'éclairage à usage général —
Prescriptions
concernant l'immunité CEM
Equipment for general lighting purposes —
EMC immunity requirements
© CEI 1995 Droits de reproduction réservés —
Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par
aucun pro- any form or by any means, electronic or mechanical,
cédé, électronique ou mécanique, y compris la photocopie et including photocopying and microfilm, without permission
les microfilms, sans l'accord écrit de l'éditeur. in writing from the publisher.
Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève, Suisse
Commission Electrotechnique Internationale
CODE PRIX
International Electrotechnical Commission
PRICE CODE L
IEC
MemnyHapoAHaa 3nelcrporexHH4ecKan KOMHCCHR
• Pour prix, voir catalogue en vigueur •
For price, see current catalogue

---------------------- Page: 7 ----------------------

SIST EN 61547:1996
1547 ©IEC:1995 — 3
CONTENTS
Page
5
FOREWORD
Clause
7
1 Scope
2 Normative references 7
Definitions 9
3
4 Performance criteria 9
11
5 Test specifications
11
5.1 General
5.2 Electrostatic discharges 13
13
5.3 Radio frequency electromagnetic fields
13
5.4 Power frequency magnetic fields
15
5.5 Fast transients
17
5.6 Injected currents
19
5.7 Surges
19
5.8 Voltage dips and interruptions
19
5.9 Voltage fluctuations
Application of test specifications 19
6
19
6.1 General
6.2 Non-electronic lighting equipment 21
6.3 Electronic lighting equipment 21
7 Conditions during testing 23
8 Assessment of conformity 23

---------------------- Page: 8 ----------------------

SIST EN 61547:1996
1547 ©IEC:1995 — 5 —
INTERNATIONAL ELECTROTECHNICAL COMMISSION
EQUIPMENT FOR GENERAL LIGHTING PURPOSES -
EMC IMMUNITY REQUIREMENTS
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization
comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to
promote international co-operation on all questions concerning standardization in the electrical and electronic
fields. To this end and in addition to other activities, the IEC publishes International Standards. Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt
with may participate in this preparatory work. International, governmental and non-governmental organizations
liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on
which all the National Committees having a special interest therein are represented, express as nearly as
possible, an international consensus of opinion on the subjects dealt with.
3) They have the form of recommendations for international use published in the form of standards, technical
reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
International Standard IEC 1547 has been prepared by IEC technical committee 34: Lamps and
related equipment.
The text of this standard is based on the following documents:
DIS Report on voting
34/39/DIS 34/40/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

---------------------- Page: 9 ----------------------

SIST EN 61547:1996
1547 ©IEC:1995 — 7 —
EQUIPMENT FOR GENERAL LIGHTING PURPOSES —
EMC IMMUNITY REQUIREMENTS
1 Scope
This International Standard for electromagnetic immunity requirements applies to lighting
equipment which is within the scope of IEC technical committee 34, such as lamps, auxiliaries
and luminaires, intended either for connecting to a low voltage electricity supply or for battery
operation.
Excluded from the scope of this standard is equipment for which the immunity requirements are
formulated in other IEC or CISPR standards such as:
— lighting equipment for use in transport vehicles;
— entertainment lighting control equipment for professional purposes;

lighting devices built-in other equipment such as:
• scale illumination or indicators;
• photocopiers;
• slide and overhead projectors;
• video display units.
However, in multi-function equipment where the lighting part operates independently from
other parts, the lighting part shall comply with the requirements of this standard.
The requirements of this standard are based on the requirements for domestic, commercial and
light-industrial environments as given in the future IEC 1000-6-1 1) ,
but modified to lighting
engineering practice.
It can be expected that lighting equipment complying with the requirements of this standard
will operate satisfactorily in other environments. In some special cases measures have to be
taken to provide greater immunity. It is impracticable to deal with all these possibilities. Such
requirements may be established by contractual agreement between supplier and purchaser.
This standard shall be read in conjunction with the relevant basic and/or product standard(s).
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. At the time of publication, the editions
indicated were valid. All normative documents are subject to revision, and parties to
agreements based on this International Standard are encouraged to investigate the possibility of
applying the most recent editions to the normative documents indicated below. Members of
IEC and ISO maintain registers of currently valid International Standards.
I EC 50(161): 1990, International Electrotechnical Vocabulary — (IEV) Chapter 161:
Electromagnetic Compatibility
IEC 50(845): 1987, International Electrotechnical Vocabulary — (IEV) Chapter 845: Lighting
1) At present at stage of document 77(sec)141

---------------------- Page: 10 ----------------------

SIST EN 61547:1996
1547 ©IEC:1995 — 9
IEC 598-1: 1992, Luminaires — Part 1: General requirements and tests
IEC 598-2-22: 1990, Luminaires— Part 2: Particular requirements — Section 22: Luminaires for
emergency lighting
IEC 1000-4-2: 1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 2: Electrostatic discharge immunity tests
IEC 1000-4-3: 1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 3: Radiated, radio frequency, electromagnetic field immunity tests
IEC 1000-4-4: 1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 4: Electrical fast transient/burst immunity tests
IEC 1000-4-5: 1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 5: Surge immunity tests
IEC/DIS 1000-4-6: Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 6: Immunity to conducted disturbances, induced by radio-frequency fields
IEC 1000-4-8: 1993, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 8: Power frequency magnetic field immunity tests
IEC 1000-4-11: 1994, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement
techniques — Section 11: Voltage dips, short interruptions and voltage variations immunity
tests
3 Definitions
For the purpose of this International Standard, the definitions of IEC 50(161) and IEC 50(845)
apply, together with the following definitions:
3.1 port: Particular electrical interface of the specified equipment with the external
electromagnetic environment.
3.2 enclosure port:
The physical boundary of the equipment through which electromagnetic
fields may radiate or penetrate.
Enclosure port
AC power port
Earth port
LIGHTING
DC power port EQUIPMENT Signal/control port
NOTE — For the purpose of this standard, d.c. power ports for supplying regulating controls are
considered to be signal ports.
Figure 1 - Examples of ports
4 Performance criteria
4.1 A functional description of performance criteria, during or as a consequence of the
immunity testing, shall be provided by the manufacturer and noted in the test report.
The performance of lighting equipment shall be assessed by monitoring:
— the luminous intensity of the luminaire or of the lamp(s);
— the functioning of the control in case of equipment which includes a regulating
control or concerns the regulating control itself;
— the functioning of the starting device, if any.

---------------------- Page: 11 ----------------------

SIST EN 61547:1996
1547 ©IEC:1995 — 11 —
4.2 The following performance criteria apply to lighting equipment:
Performance criterion A:
During the test no change of the luminous intensity shall be observed and the regulating
control, if any, shall operate during the test as intended.
Performance criterion B:
During the test the luminous intensity may change to any value. After the test the luminous
intensity shall be restored to its initial value within 1 min.
Regulating controls need not function during the test, but after the test the mode of the control
shall be the same as before the test provided that during the test no mode changing commands
were given.
Performance criterion C:
During and after the test any change of the luminous intensity is allowed and the lamp(s) may
be extinguished. After the test, within 30 min, all functions shall return to normal if necessary
by temporary interruption of the mains supply and/or operating the regulating control.
Additional requirement for lighting equipment incorporating a starting device:
After the test the lighting equipment is switched off. After half an hour it is switched on again.
The lighting equipment shall start and operate as intended.
4.3 A change of luminous intensity may be checked by visual observation but in case of doubt
the following applies:
The luminous intensity of a luminaire or of the lamp(s) shall be measured by means of a
illuminance (lux) meter which is positioned in an axis perpendicular to th
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.