(1) This document provides guidance for the development or improvement of rules deemed to help with the choosing of appropriate glazing for protection against injuries and falling, hereafter called "the Specifications". The Specifications to be written or revised can be a national regulation, a national standard, recommendations from a professional association, requirements for a particular project, etc.
(2) This document deals with the choice of the mode of breakage (see 5.2) with regard to the safety of people against:
-   the risk of injury in the event of a collision with a glazed element, e.g. a partition,
-   the risk of falling through or over a glazed element, e.g. a balustrade, and
-   the risk of accidental falling of glass fragments on people not having caused the breakage, e.g. an overhead glazing.
(3) These risks can be evaluated in the function of a normal use of the building or construction work. This includes use by the elderly, children and people with disabilities, but excludes deliberate risk taking. It presupposes a rational and responsible behaviour of the users or, in case of children, of those responsible for supervising them.
(4) The information contained in this document can be used to define minimum glass configuration. It does not exempt from the verification according to CEN/TS 19100-1 and CEN/TS 19100-2 and where appropriate CEN/TS 19100-3.
(5) Safety against burglary, vandalism, bullet attack, explosion, exposition to fire and seismic actions are not covered in this document. Preventing these risks needs further appropriate requirements.
(6) This document does not apply to the following glass products:
-   glass blocks and paver units;
-   channel-shaped glass.
(7) It also does not apply to the following applications:
-   escalators and moving walkway;
-   lifts;
-   accesses to machinery;
-   animal enclosures and aquariums;
-   greenhouses and agricultural installations;
-   temporary scaffolds.

  • Technical specification
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides a procedure to validate a calculation tool of spectrophotometric and thermal characteristics of the glass products following EN 410 or EN 673. It provides also the methodology to correctly use measured data in the calculation tool.  
The following characteristics are included in the scope of this standard:
- light transmittance (tv)
- light reflectance - both sides (rv, r'v)
- solar direct transmittance (te)
- solar direct reflectance – both sides (re, r'e)
- total solar energy transmittance (solar factor or g value) (g)
- thermal transmittance (U value) in the vertical position
The following characteristics are excluded from the scope of this standard:
- UV transmittance (tuv)
- shading coefficient (SC)
- general colour rendering index (Ra)
- thermal transmittance (U value) at angles other than vertical

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides a procedure to validate a calculation tool of spectrophotometric and thermal characteristics of the glass products following EN 410 or EN 673. It provides also the methodology to correctly use measured data in the calculation tool.  
The following characteristics are included in the scope of this standard:
- light transmittance (tv)
- light reflectance - both sides (rv, r'v)
- solar direct transmittance (te)
- solar direct reflectance – both sides (re, r'e)
- total solar energy transmittance (solar factor or g value) (g)
- thermal transmittance (U value) in the vertical position
The following characteristics are excluded from the scope of this standard:
- UV transmittance (tuv)
- shading coefficient (SC)
- general colour rendering index (Ra)
- thermal transmittance (U value) at angles other than vertical

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

(1) This document provides guidance for the development or improvement of rules deemed to help with the choosing of appropriate glazing for protection against injuries and falling, hereafter called "the Specifications". The Specifications to be written or revised can be a national regulation, a national standard, recommendations from a professional association, requirements for a particular project, etc.
(2) This document deals with the choice of the mode of breakage (see 5.2) with regard to the safety of people against:
-   the risk of injury in the event of a collision with a glazed element, e.g. a partition,
-   the risk of falling through or over a glazed element, e.g. a balustrade, and
-   the risk of accidental falling of glass fragments on people not having caused the breakage, e.g. an overhead glazing.
(3) These risks can be evaluated in the function of a normal use of the building or construction work. This includes use by the elderly, children and people with disabilities, but excludes deliberate risk taking. It presupposes a rational and responsible behaviour of the users or, in case of children, of those responsible for supervising them.
(4) The information contained in this document can be used to define minimum glass configuration. It does not exempt from the verification according to CEN/TS 19100-1 and CEN/TS 19100-2 and where appropriate CEN/TS 19100-3.
(5) Safety against burglary, vandalism, bullet attack, explosion, exposition to fire and seismic actions are not covered in this document. Preventing these risks needs further appropriate requirements.
(6) This document does not apply to the following glass products:
-   glass blocks and paver units;
-   channel-shaped glass.
(7) It also does not apply to the following applications:
-   escalators and moving walkway;
-   lifts;
-   accesses to machinery;
-   animal enclosures and aquariums;
-   greenhouses and agricultural installations;
-   temporary scaffolds.

  • Technical specification
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides a procedure to validate a calculation tool based on simulation, analytical calculation and/or interpolation of airborne sound insulation characteristics of glass products.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes a method to determine and assess sound insulation performances of all transparent, translucent and opaque glass products, for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime or supplementary characteristic. This document refers to laboratory measurement method described in ISO 10140-1:2021, Annex D and defines extension rules that can be applied without further testing. It also provides typical performance data for a range of common glass products that can be used in the absence of measured data. All the considerations of this document relate to panes of glass or glass products alone. Incorporation of them into windows can cause changes in acoustic performance as a result of other influences, e.g. frame design, frame material, glazing material or method, mounting method, air tightness. Measurements of the sound insulation of complete windows (glass and frame) can be undertaken to resolve such issues.

  • Standard
    11 pages
    English language
    sale 15% off

This document specifies a test method of light transmittance for the laminated solar photovoltaic glass for use in building. This document is applicable to flat modules with light transmittance in the visible range (wavelengths from 380 nm to 780 nm). This document does not cover the assessment method of total solar energy transmittance of the flat module.

  • Standard
    6 pages
    English language
    sale 15% off

This document specifies a procedure to validate a calculation tool based on simulation, analytical calculation and/or interpolation of airborne sound insulation characteristics of glass products.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides the specifications and specifies the requirements for the designation of three types of glass namely crystal glass, crystal, and lead crystal, according to their chemical composition, density and refractive index. This document also describes the test methods to measure the respective characteristics of these crystal glass types. Given the potential lead contamination concerns in crystal glass and crystal, this document additionally stipulates a maximum permissible limit for lead content. This document is applicable to the designated crystal glass types used as tableware, containers (e.g. bottles, decanters, perfume jars), giftware, home decor and any decorative components in consumer goods (e.g. glass components and/or parts used in jewellery, textile applications, and electrical and electronic equipment), furniture and luminaries. This document does not apply to crystal glass types used within the areas of construction, healthcare and laboratories, and other technical uses of glass.

  • Standardization document
    6 pages
    English language
    sale 15% off

This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance which enables assessment of compliance with the acoustic requirements of buildings.
Rigorous technical analysis of measurement data remains an option, but this standard is intended to enable the derivation of simpler indices of performance, which can be adopted with confidence by non-specialists.
By adopting the principles of this standard the formulation of acoustic requirements in Building Codes and for product specification to satisfy particular needs for glazing is simplified.
It is recognised that the acoustic test procedures contained within EN ISO 140-1 and EN ISO 140-3 relate only to glass panes and their combinations. Although the same principles should be followed as closely as possible, it is inevitable that some compromises are necessary, because of the bulkier construction of other glazing types, e.g. glass blocks, paver units, channel-shaped glass, structural glazing and structural sealant glazing. Guidelines on how to adapt the test procedures for these glazing types are offered in Clause 4.
All the considerations of this standard relate to panes of glass/glazing alone. Incorporation of them into windows may cause changes in acoustic performance as a result of other influences, e.g. frame design, frame material, glazing material/method, mounting method, air tightness, etc. Measurements of the sound insulation of complete windows (glass and frame) may be undertaken to resolve such issues.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies two methods for testing the resistance of raw optical glasses to attack by aqueous acidic solutions and defines a classification of optical glasses according to the acid resistance determined by these methods. The surface method tests the resistance of the polished plate-shaped optical glass to attack by aqueous acidic solutions at 25 °C for a specified time and indicates the class determined by this method as “SR-S”. The powder method tests the resistance of crushed granular optical glass to attack by an acidic aqueous solution at above 98 °C for 1 h, and indicates the class determined by this method as “SR-P”.

  • Standard
    17 pages
    English language
    sale 15% off

This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance which enables assessment of compliance with the acoustic requirements of buildings.
Rigorous technical analysis of measurement data remains an option, but this standard is intended to enable the derivation of simpler indices of performance, which can be adopted with confidence by non-specialists.
By adopting the principles of this standard the formulation of acoustic requirements in Building Codes and for product specification to satisfy particular needs for glazing is simplified.
It is recognised that the acoustic test procedures contained within EN ISO 140-1 and EN ISO 140-3 relate only to glass panes and their combinations. Although the same principles should be followed as closely as possible, it is inevitable that some compromises are necessary, because of the bulkier construction of other glazing types, e.g. glass blocks, paver units, channel-shaped glass, structural glazing and structural sealant glazing. Guidelines on how to adapt the test procedures for these glazing types are offered in Clause 4.
All the considerations of this standard relate to panes of glass/glazing alone. Incorporation of them into windows may cause changes in acoustic performance as a result of other influences, e.g. frame design, frame material, glazing material/method, mounting method, air tightness, etc. Measurements of the sound insulation of complete windows (glass and frame) may be undertaken to resolve such issues.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the requirements for and testing of sealants for use in one or more of the following applications:
a)   Manufacturing of insulating glass units where direct ultraviolet resistance and mechanical resistance (Bonding use) of the insulating glass edge seal are required.
b)   Manufacturing of factory-made bonded sealant glazing elements when referred to by the relevant European Standards and/or European Technical Approval Guidelines.
c)   Assembling of glass products into or onto supports, where also direct ultraviolet resistance and/or mechanical resistance (bonding use) of the seal are required, under controlled environmental conditions as described in EN 13022 2:2014, Clause 5.
NOTE 1   The required level of resistance to ultraviolet exposure will be dependent upon the chemistry of sealant. Reduced UV exposure testing is acceptable for proven silicone technologies. Extended UV exposure will be required for different technologies.
This document covers the evaluation of conformity and the factory production control with respect to the production of sealants in conformity with this document.
This document describes the role of sealants that are in conformity with this document, with respect to sealing and bonding.
This document does not apply to sealants for the manufacture of insulating glass units where the seal is fully protected, i.e. by a frame, from ultraviolet radiation.
NOTE 2   Sealants for this application comply with EN 1279 4.
This document contains other aspects of importance for trade.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the requirements for, and testing of sealants for use in one or more of the following applications:
a)   Manufacturing of insulating glass units where direct ultraviolet resistance and mechanical resistance (bonding use) of the insulating glass edge seal are required;
b)   Manufacturing of factory-made bonded sealant glazing elements when referred to by the relevant European Standards and/or European Technical Approval Guidelines;
c)   Assembling of glass products into or onto supports, where also direct ultraviolet resistance and/or mechanical resistance (bonding use) of the seal are required, under controlled environmental conditions as described in EN 13022-2.
This document covers the evaluation of conformity and the factory production control with respect to the production of sealants in conformity with this document.
This document describes the role of sealants that are in conformity with this document, with respect to sealing and bonding.
This document does not apply to sealants for the manufacture of insulating glass units where the seal is fully protected, i.e. by a frame, from ultraviolet radiation.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives test methods to assess the shatter properties of different types of monolithic flat glass for use in building and construction works, for which a specific fragmentation pattern is required when tested under defined conditions.
NOTE   Thermally treated monolithic glass are products for which such requirement exists.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives test methods to assess the shatter properties of different types of monolithic flat glass for use in building and construction works, for which a specific fragmentation pattern is required when tested under defined conditions.
NOTE Thermally treated monolithic glass is a product for which such a requirement exists.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies defects of finished sizes and test methods with regard to the appearance of laminated glass and laminated safety glass when looking through the glass.
All references to laminated glass in this document refer to both laminated glass and laminated safety glass.
NOTE      Special attention is paid to acceptability criteria in the vision area.
This document is applicable to finished sizes at the time of supply.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terms and describes component parts for laminated glass and laminated safety glass for use in building.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements for laminated safety glass as defined in ISO 12543-1.
NOTE       Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods relating to resistance to high temperature, humidity and radiation for laminated glass and laminated safety glass for use in building.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies dimensions, limit deviations and edge finishes of laminated glass and laminated safety glass for use in building.
This document is not applicable to panes having an area less than 0,05 m2.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements for laminated glass as defined in ISO 12543-1.
NOTE       Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terms and describes component parts for laminated glass and laminated safety
glass for use in building.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies dimensions, limit deviations and edge finishes of laminated glass and laminated
safety glass for use in building.
This document is not applicable to panes having an area less than 0,05 m2.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements for laminated safety glass as defined in ISO 12543-
1.
NOTE Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terms relating to raw optical glass and related manufacturing processes. The list is not complete and only comprises those terms for which the definition is considered necessary for correct and adequate understanding of the terminology. It is understood that the interpretations given are those corresponding to the practical usage in this field and that they do not necessarily coincide with those used in other fields.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

This document specifies test methods relating to resistance to high temperature, humidity and
radiation for laminated glass and laminated safety glass for use in building.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements for laminated glass as defined in ISO 12543-1.
NOTE Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies defects of finished sizes and test methods with regard to the appearance of
laminated glass and laminated safety glass when looking through the glass.
All references to laminated glass in this document refer to both laminated glass and laminated safety
glass.
NOTE Special attention is paid to acceptability criteria in the vision area.
This document is applicable to finished sizes at the time of supply.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for retesting laminated solar photovoltaic (PV) glass for use in buildings. This document applies to laminated solar PV glass.

  • Technical specification
    8 pages
    English language
    sale 15% off
  • Technical specification
    8 pages
    English language
    sale 15% off

This document specifies the method to be used to verify the mechanical performance of the bonded glazing for doors, windows and curtain walling (see examples in Annex A) and its durability. The bonding covered is only that between the glass and the untreated, treated or coated metal surface.
NOTE 1   Bonded glazing was formerly known as structural sealant glazing SSGS.
This document covers bonded glazing incorporated into the product construction works as follows:
-   either vertically; or
-   up to 83° from the vertical (positive slope); or
-   up to 15° from the vertical onto the building face (negative slope).
NOTE 2   A wall has a positive slope if its outer surface faces upwards (see Figure A.1).
Specific additional safety provisions may apply nationally.
This document gives information to the manufacturer to comply with requirements regarding design, factory production control and assembly rules.
The parts concerned in the testing are the metal surface (anodized and coated aluminium, stainless steel), the surface of glass, provided or not, with a layer or coating, which shall be bonded, the bonding sealant and mechanical restraints when required.
This document does not apply to:
-   other surfaces materials;
-   direct glazing;
-   glass-to-glass bonding and edge seal of insulating glass units (which are covered by EN 13022-1 and EN 1279-5);
-   adhesive tapes.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1      Scope of CEN/TS 19100 3
(1) This document gives design rules for mechanically supported glass components primarily subjected to in-plane loading. It also covers construction rules for mechanical joints for in-plane loaded glass components.
NOTE   In-plane loaded glass elements are primarily subjected to in-plane loads, e.g. transferred from adjacent parts of a structure. They can also be subjected to out-of-plane loading.
1.2      Assumptions
(1) The assumptions of EN 1990 apply to this document.
(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995 1 1, EN 1998 1, EN 1999 1 1 and EN 12488.

  • Technical specification
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of CEN/TS 19103
(1)   CEN/TS 19103 gives general design rules for timber-concrete composite structures.
(2)   It provides requirements for materials, design parameters, connections, detailing and execution for timber-concrete composite structures. Recommendations for environmental parameters (temperature and moisture content), design methods and test methods are given in the Annexes.
(3)   It includes rules common to many types of timber-concrete composite, but does not include details for the design of glued timber-concrete composites, nor for bridges.
NOTE   For the design of glued timber-concrete composites or bridges alternative references are available.
(4)   It covers the design of timber-concrete composite structures in both quasi-constant and variable environmental conditions. For ease of use, it provides simple design rules for quasi-constant environmental conditions and more complex rules for variable environmental conditions.
1.2   Assumptions
(1)   The general assumptions of EN 1990 apply.
(2)   CEN/TS 19103 is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN  1992 (all parts), EN  1994 (all parts), EN 1995 (all parts), EN 1998 (all parts) when timber structures are built in seismic regions, and ENs for construction products relevant to timber structures.

  • Technical specification
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of FprCEN/TS 19100-1
(1) FprCEN/TS 19100-1 gives basic design rules for mechanically supported glass components. This document is concerned with the requirements for resistance, serviceability, fracture characteristics and glass component failure consequences in relation to human safety, robustness, redundancy and durability of glass structures.
(2) This document covers the basis of design, materials, durability and structural design.
(3) This document also covers construction rules for the structural design of glass components.
1.2   Assumptions
(1) The assumptions of EN 1990 apply to FprCEN/TS 19100-1.
(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995 1 1, EN 1998 1, EN 1999 1 1 and EN 12488.

  • Technical specification
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of FprCEN/TS 19100 2
(1) FprCEN/TS 19100 2 gives basic structural design rules for mechanically supported glass components primarily subjected to out of plane loading. Out of plane loaded glass components are made of flat or curved glass components.
NOTE   Out of plane loads are loads acting normal (e.g wind) to or having a component (e.g dead load, snow, ...) acting normal to the glass plane.
1.2   Assumptions
(1) The assumptions of EN 1990 apply to FprCEN/TS 19100-2.
(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995 1 1, EN 1998 1, EN 1999 1 1 and EN 12488.

  • Technical specification
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements for laminated safety glass as defined in ISO 12543-1. NOTE Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.

  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off

This document specifies dimensions, limit deviations and edge finishes of laminated glass and laminated safety glass for use in building. This document is not applicable to panes having an area less than 0,05 m2.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

This document specifies defects of finished sizes and test methods with regard to the appearance of laminated glass and laminated safety glass when looking through the glass. All references to laminated glass in this document refer to both laminated glass and laminated safety glass. NOTE Special attention is paid to acceptability criteria in the vision area. This document is applicable to finished sizes at the time of supply.

  • Standard
    6 pages
    English language
    sale 15% off
  • Standard
    6 pages
    English language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off

This document defines terms and describes component parts for laminated glass and laminated safety glass for use in building.

  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off

This document specifies performance requirements for laminated glass as defined in ISO 12543-1. NOTE Any defects that are found in installed laminated safety glass are dealt with in ISO 12543-6.

  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    5 pages
    French language
    sale 15% off
  • Standard
    5 pages
    French language
    sale 15% off

This document specifies test methods relating to resistance to high temperature, humidity and radiation for laminated glass and laminated safety glass for use in building.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

This European Standard specifies the critical dimensions of the neck finish of glass aerosol containers with respect to the thorough and tight closing of valves with ferrules defined in EN 14849.
This standard is applicable to a nominal diameter of 11 mm, 13 mm, 15 mm, 17 mm, 18 mm and 20 mm necked aerosol containers with moulded and tubular neck finishes.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of FprCEN/TS 19100 2
(1) FprCEN/TS 19100 2 gives basic structural design rules for mechanically supported glass components primarily subjected to out of plane loading. Out of plane loaded glass components are made of flat or curved glass components.
NOTE   Out of plane loads are loads acting normal (e.g wind) to or having a component (e.g dead load, snow, ...) acting normal to the glass plane.
1.2   Assumptions
(1) The assumptions of EN 1990 apply to FprCEN/TS 19100-2.
(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995 1 1, EN 1998 1, EN 1999 1 1 and EN 12488.

  • Technical specification
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of FprCEN/TS 19100-1
(1) FprCEN/TS 19100-1 gives basic design rules for mechanically supported glass components. This document is concerned with the requirements for resistance, serviceability, fracture characteristics and glass component failure consequences in relation to human safety, robustness, redundancy and durability of glass structures.
(2) This document covers the basis of design, materials, durability and structural design.
(3) This document also covers construction rules for the structural design of glass components.
1.2   Assumptions
(1) The assumptions of EN 1990 apply to FprCEN/TS 19100-1.
(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995 1 1, EN 1998 1, EN 1999 1 1 and EN 12488.

  • Technical specification
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1      Scope of CEN/TS 19100 3
(1) This document gives design rules for mechanically supported glass components primarily subjected to in-plane loading. It also covers construction rules for mechanical joints for in-plane loaded glass components.
NOTE   In-plane loaded glass elements are primarily subjected to in-plane loads, e.g. transferred from adjacent parts of a structure. They can also be subjected to out-of-plane loading.
1.2      Assumptions
(1) The assumptions of EN 1990 apply to this document.
(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995 1 1, EN 1998 1, EN 1999 1 1 and EN 12488.

  • Technical specification
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of CEN/TS 19103
(1)   CEN/TS 19103 gives general design rules for timber-concrete composite structures.
(2)   It provides requirements for materials, design parameters, connections, detailing and execution for timber-concrete composite structures. Recommendations for environmental parameters (temperature and moisture content), design methods and test methods are given in the Annexes.
(3)   It includes rules common to many types of timber-concrete composite, but does not include details for the design of glued timber-concrete composites, nor for bridges.
NOTE   For the design of glued timber-concrete composites or bridges alternative references are available.
(4)   It covers the design of timber-concrete composite structures in both quasi-constant and variable environmental conditions. For ease of use, it provides simple design rules for quasi-constant environmental conditions and more complex rules for variable environmental conditions.
1.2   Assumptions
(1)   The general assumptions of EN 1990 apply.
(2)   CEN/TS 19103 is intended to be used in conjunction with EN 1990, EN 1991 (all parts), EN  1992 (all parts), EN  1994 (all parts), EN 1995 (all parts), EN 1998 (all parts) when timber structures are built in seismic regions, and ENs for construction products relevant to timber structures.

  • Technical specification
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the properties of glass blocks used for the construction of non-load-bearing walls and horizontally spanning panels. This document also specifies test methods used to verify these properties for square, rectangular and circular glass blocks.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off

This document specifies the accelerated ageing test and requirements for electrochromic glazings intended to either control direct or indirect solar transmission, or both. The electrochromic glazings can be assembled as insulating glass unit, laminated glass or combination of both. The test method described in this document is only applicable to chromogenic glazings that can be switched between different transmission states using an electrical stimulus. This test method is not applicable to other chromogenic glazings such as photochromic and thermochromic glazings, which do not respond to electrical stimulus. This test method is applicable to any electrochromic glazing fabricated for use in buildings such as in doors, windows, skylights, exterior wall systems and glazing exposed to solar radiation. The materials used for constructing the electrochromic glazing and for electrochromically changing its optical properties can be inorganic or organic materials.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

This document specifies test methods for evaluation of performance of vacuum insulating glass samples with rigid edge seal when subjected to temperature differences between the glass sheets. This document is not applicable to vacuum insulating glass samples with flexible edge seal.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off

This document provides specific rules for the assessment of the release on dangerous substances from glass products into indoor air of buildings in complement to the horizontal rules given in EN 16516.
This document addresses specifically products as mentioned in TC 129 Mandate - M135 Amendment 1 EN (2012), i.e. products covered by the following European Standards: EN 1036 2 and EN 16477 21. However, this document can also be applied to other glass products containing volatile organic compounds (VOC) such as: EN 1279 5, EN 15755 1 and EN 14449. Glass products that do not contain organic compounds are not in the scope of this document (see Annex A).
This document addresses the release of dangerous substances into indoor air from construction products, although it can also be applied to glass products used in other applications such as furniture.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day