This document specifies a method for determination of the mechanical durability of pellets. The mechanical durability is a measure of the resistance of compressed fuels towards shocks and/or abrasion as a consequence of handling and transportation.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for the determination of major and minor element concentrations in solid recovered fuels after digestion by the use of different acid mixtures and by addition of a fluxing agent for solid recovered fuel (SRF) ash.
a)       Method A: Microwave assisted digestion with hydrochloric, nitric and hydrofluoric acid mixture (6 ml HCl; 2 ml HNO3; 2 ml HF) followed by boric acid complexation;
b)       Method AT: Microwave assisted digestion with hydrochloric, nitric and tetrafluoroboric acid mixture (6 ml HCl; 2 ml HNO3; 4 ml HBF4);
c)        Method B: Microwave assisted digestion with hydrochloric, nitric and hydrofluoric acid mixture (0,5 ml HCl; 6 ml HNO3; 1 ml HF) followed by boric acid complexation;
d)       Method BT: Microwave assisted digestion with hydrochloric, nitric and tetrafluoroboric acid mixture (0,5 ml HCl; 6 ml HNO3; 2 ml HBF4);
e)       Method C: Microwave assisted digestion with nitric acid, hydrogen peroxide and hydrofluoric acid mixture (2,5 ml H2O2; 5 ml HNO3; 0,4 ml HF) and optional boric acid complexation;
f)         Method CT: Microwave assisted digestion with nitric acid, hydrogen peroxide and tetrafluoroboric acid mixture (2,5 ml H2O2; 5 ml HNO3; 0,8 ml HBF4);
g)       Method D: Digestion of the ashed SRF sample with fluxing agent lithium metaborate in an oven at 1 050 °C.
This document is applicable for the following major and minor/trace elements:
—     Major elements: aluminium (Al), calcium (Ca), iron (Fe), potassium (K), magnesium (Mg), sodium (Na), phosphorus (P), sulfur (S), silicon (Si) and titanium (Ti).
—     Minor/trace elements: arsenic (As), barium (Ba), beryllium (Be), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), mercury (Hg), molybdenum (Mo), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), selenium (Se), tin (Sn), thallium (Tl), vanadium (V) and zinc (Zn).
Method A is applicable for general use for SRF and ashed SRFs, but the amount of the test portion can be very low in case of high concentration of organic matter. Method AT can be used if an alternative to HF is necessary.
Method B with a higher volume of nitric acid is applicable for SRFs with high organic matter (e.g. suitable for high plastic content) that can be difficult to digest with less nitric acid or as a substitute for method A if appropriate equipment is not available. Method BT can be used if an alternative to HF is necessary.
Method C with combination of nitric acid and hydrogen peroxide and addition of hydrofluoric acid is applicable for wood based SRFs (e.g. demolition wood) or when there is a need for comparability to solid biofuel standards. Method CT can be used if an alternative to HF is necessary.
Method D is specifically applicable for determination of major elements in ashed SRF samples.
XRF can be used for the analysis of major elements (Al, Ca, Fe, K, Mg, Na, P, S, Si, Ti) after ashing (815 °C) of the samples and several major and minor/trace elements in SRF can be analysed by XRF after suitable calibration provided that the concentration levels are above instrumental detection limits of the XRF instrumentation and after proper preliminary testing and validation.
Digestion methods with HF and subsequent boric acid complexation or application of method D are applicable for determination of Si and Ti (better digestion efficiency).
Alternative digestion methods can be applied, if their performance is proved to be comparable with those of the methods described in this document.

  • Standard
    92 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This NWI Will be a TS and will specify additional requirements for qualified or not qualified trust services implementing electronic archiving service with specific regard to :
•   Functional requirements to use for receipt, storage, retrieval and deletion to ensure that the electronic data and electronic documents (electronically-born documents  and paper documents that have been scanned and digitized) are preserved in such a way that they are accessible and durably safeguarded against loss and unauthorized alteration or disposal, except for authorized changes concerning their electronic format.
•   Procedures and technologies ensuring the accuracy of the origin, the durability and legibility, integrity of the electronic data and electronic documents beyond the technological validity period and at least throughout the legal or contractual preservation period, while maintaining their integrity and their origin.
•   Procedures and technologies to use to allow authorised relying parties to receive a report in an automated manner that confirms that an electronic data  and electronic documents retrieved from a qualified electronic archive enjoys the presumption of integrity of the data and electronic documents from the beginning of the preservation period to the moment of retrieval.
•   Procedures and technologies to prevent unauthorized access and improper use of the confidential and restricted data and electronic documents.
•   Interactions between electronic archiving trust services and other trust services.
•   Procedures and technologies to reach and obtain a green sustainability approach when possible.

  • Technical specification
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a tensile bending method and a compression bending method for determining the failure stress of welded corners and welded T-joints made from unplasticized poly(vinyl chloride) (PVC-U) profiles.
It is applicable to PVC based profiles used for the fabrication of windows and doors.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance on the use of colour codes to inform people at risk as well as first response personnel about danger and to express the severity of a situation.
This document is applicable to all types of hazard in any location.
This document does not apply to the method for displaying colour codes, detailed ergonomic considerations related to viewing displays or safety signs covered by ISO 3864-1.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric sewing machines for household and similar use, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies guidelines for a use of social media in emergency management. It gives
guidance on how to use social media before, during and after an emergency and how social
media can support the work of emergency services. On the one hand, these guidelines are directed to
authorities (governmental as well as non­governmental organisations) involved in emergency management.
On the other hand, they are directed to citizens who want to use social media in emergency
situations.
These guidelines shall help social media users to use these new media as efficiently as possible.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes an approach and methodology for a country-based mechanism to channel climate finance to subnational
authorities to support climate change adaptation and to increase local resilience thereby contributing to the achievement of the goals
of the 2015 Paris Agreement of the United Nations Framework Convention on Climate Change (UNFCCC) and the UN Sustainable
Development Goals (SDGs). The country-based mechanism uses performance-based climate resilience grants (PBCRGs) which
ensure programming and verification of climate change expenditures at the local level, offering strong incentives for performance
improvements in enhanced resilience.
This document provides requirements and guidelines and is applicable to organizations such as national and subnational authorities,
donors, companies, financial institutions and international organizations that are involved in implementing a country-based
mechanism for channelling climate finance to subnational authorities to support climate change adaptation and resilience.
NOTE Another mechanism for supporting local adaptation is by direct support at the local level by donors without any financial
flows from national government.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for the fire safety of candle accessories, as well as safety information ‎and requirements on how safety information will be displayed.
The safety requirements and test methods specified in this document are intended to cover the most common risks.
This document does not specify requirements or test methods for uncommon risks arising from the unforeseen combination of accessories and candles.
This document does not apply to birthday cake candle holders that can hold only one candle and do not contain pyrotechnics.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric insect killers for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes requirements, test procedures, assessment methods and acceptance criteria for operating rolling stock in open track. For pressure variations and slipstream effects beside the track, requirements and assessment methods are provided. For running resistance, assessment methods are addressed in this document. Load cases on infrastructure components due to train-induced pressure variations and slipstream effects are addressed in this document. For ballasted track test set-ups for ballast projection assessment are proposed.
The requirements only apply to rolling stock of the heavy rail system with maximum train speeds above 160 km/h and not to other rail systems. The document is applicable to all rolling stock and infrastructure in open air with nominal track gauges of 1 435 mm to 1 668 mm inclusive.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to determine the influence of site-applied cement based materials and associated non-cement based products/materials (including pre-packaged mortars) on the odour, flavour, colour, turbidity and total organic carbon (TOC) of test waters after contact with the products.
This document is applicable to site-applied or site-formed cement based materials intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water. It is also applicable to individual constituents of cement based products/materials and to associated non-cement based products/materials.
Site-applied or site-formed cement based materials which cannot be cast as cubes or prisms e.g. some spray applied systems, should be tested as factory made cement based products according to EN 14944−1.
NOTE   Tests with the specified test water will not necessarily be representative of materials used in different kinds of waters and especially very soft waters.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electrical recovery and/or recycle equipment to recover and/or recycle refrigerant from air conditioning and refrigeration equipment.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of stand-alone electric spin extractors, and pin extractors incorporated in washing machines that have separate containers for washing and spin extraction for household and similar purposes that have a capacity not exceeding 10 kg of dry cloth and a drum peripheral speed not exceeding 50 m/s, their rated voltages being not more than 250 V for single-phase appliances and 480 V for other appliances

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric sewing machines for household and similar use, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of
- portable heated carpets;
- heated carpets and similar appliances;
- heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines fundamental terminology for blockchain and distributed ledger technologies.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to determine the migration of substances from hardened cement based site-applied or site-formed materials (including pre-packaged mortars) into test waters after contact with the products. It also covers determination of migration from individual constituents of cement based products and materials (see Annexes A and B) and from associated non-cement based products for approval purposes (see Annex C).
Site-applied or site-formed cement based materials which cannot be cast as cubes or prisms e.g. some spray applied systems, fall in the scope of EN 14944−3 and not under this standard.
This document is applicable to site-applied or site-formed cement based materials intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water. It is also applicable to individual constituents of cement based products/materials and to associated non-cement based products/materials.
NOTE   Tests with the specified test water will not necessarily be representative of materials used in different kinds of waters and especially very soft waters.

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of stand-alone electric spin extractors, and pin extractors incorporated in washing machines that have separate containers for washing and spin extraction for household and similar purposes that have a capacity not exceeding 10 kg of dry cloth and a drum peripheral speed not exceeding 50 m/s, their rated voltages being not more than 250 V for single-phase appliances and 480 V for other appliances

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for the physical properties of powered toothbrushes in order to promote the safety of these products for their intended use.
There are different technologies of powered toothbrushes. Common features of those powered toothbrushes to which this document applies are:
—     a battery;
—     a motor;
—     a mechanical or magnetic drive system;
—     a moving brush head with tufted filaments.
Powered toothbrushes can have a moving brush head with different motions (e.g. oscillating-rotating, side-by-side), frequencies and velocities.
These types of electric toothbrushes are tested for safety in use by means of appropriate test procedures or clinical studies
The requirements listed in this document apply to all types of powered toothbrushes. However, there is a possibility that some requirements are not applicable for all types. For example, brush head plate retention can only be applied if the brush has a head portion that can detach from the brush shaft. In addition, for the filaments end-rounding requirements, this document does not apply to filament types that are very thin (less than 0,1 mm outside diameter) or have no sharp edges (e.g. tapered, feathered, with split tips or spherical cap) or non-synthetic filaments, where applying the end-rounding process is inappropriate or impossible.
This document is not applicable to other types of powered oral hygiene devices (such as powered interdental brushes) or manual toothbrushes.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances that are within the scope of this standard are: amusement machines; tables; bowling machines; dartboards; driving simulators; gaming machines; kiddie rides; laser shooting appliances; pinball machines; video games; personal service machines; card re-value machines; currency dispensers; luggage lockers; weighing machines; shoe shining appliances. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by users and maintenance persons

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of
- portable heated carpets;
- heated carpets and similar appliances;
- heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric insect killers for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 2477:2005 describes a method for determining the permanent change in dimensions on heating of a shaped insulating refractory product.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electrical recovery and/or recycle equipment to recover and/or recycle refrigerant from air conditioning and refrigeration equipment.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance and requirements for the assessment of conformity of compounds/formulations, products, joints and assemblies in accordance with the applicable part(s) of EN 14758 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   A basic test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2   If certification is involved, the certification body operating according to EN ISO/IEC 17065 [1] and EN ISO/IEC 17020 [2] is considered to be competent.
In conjunction with EN 14758-1, this document is applicable to solid wall pipes and fittings with or without internal and/or external skin and the system made of mineral modified polypropylene materials (PP-MD) intended to be used for non-pressure underground drainage and sewerage:
-   outside the building structure (application area code “U”); and
-   for both buried in ground within the building structure and outside the building structure (application area code “UD”).

  • Technical specification
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test methods for temporary edge protection systems for use during construction or maintenance of buildings and other structures.
This document applies to edge protection systems for flat and inclined surfaces and specifies the requirements for three classes of temporary edge protection.
For edge protection systems with an arrest function (e.g. falling or sliding down a sloping roof) this document specifies requirements for energy absorption.
This document includes edge protection systems, some of which are fixed to the structure and others, which rely on gravity and friction on flat surfaces.
This document does not provide requirements for edge protection systems intended for:
—   protection against impact from vehicles or from other mobile equipment,
—   protection from sliding down of bulk loose materials, snow etc,
—   protection of areas accessible to the public.
This document does not apply to side protection on scaffolds according to EN 12811 1 and EN 1004 1.
NOTE   This does not prevent these systems to be used on temporary structures.

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This document is applicable to food depositors as listed in 1.2 and the equipment typically integrated with them, i.e. product pumps, product elevators, conveyors and indexing mechanisms, when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer (see Annex B).
This document deals with the significant hazards, hazardous situations and events during transport, assembly and installation, commissioning, use, decommissioning, disabling, dismantling and scrapping.
NOTE 1   According to the clause which is referred to, "use" includes "setting, teaching/programming or process changeover, operation, cleaning, fault finding and maintenance".
NOTE 2   Although this document is intended to apply to depositors used in the food industry, many of its requirements can also be used for the same or similar machines used in other industries.
This document does not apply to the following machines:
- auger depositors or auger fillers and gravimetric filling machines; safety requirements for these machines are contained in EN 415-3;
- automatic dough dividers, safety requirements for these machines are contained in EN 12042;
- filling machines for sausages, safety requirements for these machines are contained in EN 12463;
- mincing machines, safety requirements for these machines are contained in EN 12331;
- food depositors that are powered exclusively by manual effort;
- roller depositors intended for use in craft bakeries. Safety requirements for these machines are in EN 17677.
This document does not deal with the following hazards:
- hazards related to the use of food depositors in a potentially explosive atmosphere;
- hazards that can arise from using a food depositor to deposit a non-food product.
This document is not applicable to food depositors that were manufactured before the date of its publication as a European Standard.
1.2   Types of food depositors
1.2.1   General
This document deals with five different types of food depositor. The component parts of each of the different types of depositor are labelled in the figures shown in Clause 4 of this document.
1.2.2   Piston depositor
A piston depositor typically comprises a hopper, a rotary valve, a product measuring chamber in the form of a piston and a product dispensing valve. Some piston depositors incorporate several product measuring chambers and dispensing valves. Some designs dispense the product directly from the rotary valve without the use of a separate product dispensing valve. The volume of product dispensed is varied by altering the stroke of the product measuring chamber piston. Piston depositors are used to fill liquids, liquids containing solids in suspension and pastes. The product dispensing valve can be attached rigidly to the depositor or using a flexible pipe and in some cases is held by the operator. Figure 1 shows the typical cross section of a piston depositor.
Figure 1 - Piston depositor
1.2.3   Chamber depositor
A chamber depositor comprises a hopper feeding one or more product measuring chambers that are filled under gravity from the top. When the chamber has been filled with product the flow of product is stopped either by moving the chamber or using a product cutting device. The product is then discharged through the bottom of the chamber either by moving the chamber or by moving a plate in the base of the chamber. The volume of product dispensed is varied by altering the volume of the chamber. Chamber depositors are typically used to deposit free-flowing products like cooked rice or pasta. Figure 2 shows the typical cross section of a chamber depositor.
Figure 2 - Chamber depositor
1.2.4   Roller depositor
A roller depositor typically comprises a hopper that feeds product to two or more fluted contra-rotating rollers. These rollers force the product through one or more dies that shape the product.
...

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as:
a)       bed frames;
b)       bedside tables;
c)        transport carts;
d)       containers;
e)       surgical tables;
f)         sterilization containers;
g)       surgical clogs;
h)       wheelchairs;
i)         aids for persons with disabilities.
This document also specifies the performance requirements for the cleaning and disinfection of the WD and its components and accessories.
Devices identified within the scopes of ISO 15883-2, ISO 15883-3, ISO 15883-4, and ISO 15883-6 do not fall within the scope of this document.
In addition, this document specifies the methods for type testing, works testing, validation (installation, operation, and performance qualification on first installation), routine control, and monitoring, as well as requalifications to be carried out periodically and after essential repairs.
NOTE 1        WD covered by this document can also be used for cleaning and chemical disinfection of other thermolabile and reusable devices as recommended in the instructions for use (IFU) for those devices.
NOTE 2        The performance requirements specified in this document cannot ensure the inactivation or removal of the causative agent(s) (prion proteins) of transmissible spongiform encephalopathies.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-3-202:2025 provides performance test methods specialized for the thermal and electrical characteristics of an energy management system to effectively share the heat and power of networked small stationary fuel cell power systems. These test methods are applied for each small stationary fuel cell power system. This document covers small stationary fuel cell power systems which can be complemented with a supplementary heat generator or a thermal storage system, or both, such as:
- output: rated electric power output of less than 10 kW for each system;
- output mode: grid-connected or independent operation or stand-alone operation with alternating current (AC) output not exceeding 240 V or direct current (DC) output;
- operating pressure: maximum allowable working pressure of less than 0,1 MPa (G) for the fuel and oxidant passages;
- fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen) or liquid fuel (kerosene, methanol); oxidant: air.
This document does not apply to small stationary fuel cell power systems with electricity storage other than (small scale) back-up power for safety, monitoring and control.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements relating to:
Aluminium alloy AL-P2014A
T6 or T62
Clad sheets and strips
0,4 mm ≤ a ≤ 6 mm
for aerospace applications.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies two accelerated corrosion test methods. These methods assess the corrosion resistance of products containing copper in environments where there is a significant influence of chloride ions, mainly as sodium chloride from a marine source or winter road de-icing salt, as well as the influence of corrosion-promoting gases from industrial or traffic air pollution.
This document specifies both the test apparatus and test procedures to be used in executing the accelerated corrosion tests.
The methods are especially suitable for assessing the corrosion resistance of sensitive products with metals, e.g. electronic components, used in traffic and industrial environments.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the most important design and metrological characteristics of two-point inside micrometers:
—    with a scale interval or digital step of 0,001 mm and 0,01 mm;
—    with analogue or digital indication.
This document is applicable to two-point inside micrometers with and without interchangeable extensions.
This document does not apply to micrometers fitted with a dial gauge, or to jaw micrometers.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies three methods for the determination of the ash of poly(vinyl chloride).
The general procedures given in ISO 3451-1 are followed. For ash, method A is used. For sulfated ash, methods B and C are used. All three methods are applicable to resins, compounds and finished products. Methods B and C are applicable when lead-containing compounds are present.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general characteristics, conditions for qualification, acceptance and quality assurance for a fibre optic cable with a 62,5 µm/125 µm simplex fibre, 2,74 mm outside cable diameter and of semi-loose construction. The basic construction is the cable specified in EN 4641-102 with added sheaths for ruggedized usages.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the effective control of non-deliverable software. This document can be used during the design, development, test, production, release, use, maintenance, and retirement of non-deliverable software. This can include non-deliverable software procured from external suppliers and utilized in the design, production, evaluation, test, acceptance, or calibration of a deliverable product.
This document focuses solely on the unique requirements of the operational processes that pertain to non-deliverable software as identified below:
This document applies to non-deliverable software (including firmware) that affects a deliverable product or service. Following are several applications and supporting examples of non-deliverable software that is within the scope of this document:
—   design and development: modelling, simulation, virtual reality, virtual machine, computer-aided design (CAD), three-dimensional (3D) modelling and analysis tools, software compiler, and code generators;
—   manufacturing: additive manufacturing, computer numerical controlled (CNC) programs, robotics, factory automation, tools that load deliverable software, software used in special process (e.g. heat treat, shot peen, sonic wall inspection), and automated manufacturing software (i.e. pick and place);
—   verification, validation and maintenance: coordinate measuring machine (CMM) programs, hardware or software qualification, code coverage, test scripts, analysis tools, acceptance test, production acceptance, calibration (inspection, test or calibration), simulator, emulator, and software used in post-delivery service provisions.
The following types of software are not within scope of this document:
—   deliverable software (refer to EN 9115);
—   manufacturing and measuring equipment embedded software (e.g. operating system, drivers);
—   enterprise or office software (e.g. MS Office, word processing or spreadsheet applications, Teams, network software, email, employee management system).
Operational processes not covered in this document are addressed by the respective organization’s quality management system (QMS), based on the EN 9100-series (i.e. EN 9100, EN 9110, EN 9120) and/or ISO 9001 standards.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test methods to evaluate the performance of coaxial, quadrax and databus cables after the installation of plastic cable ties.
It is expected to be used together with EN 3475 100.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method of determining the ability of elements of connection to withstand sinusoidal or random vibrations of specified severities.
It is used together with EN 2591-100.
This test is based on EN 60068-2-6 and EN 60068-2-64.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the International Standard name identifier (ISNI) for the identification of public identities of parties, i.e. the identities used publicly by parties involved throughout the media content industries in the creation, production, management and content distribution chains.
The ISNI system uniquely identifies public identities across multiple fields of creative activity and provides a tool for disambiguating public identities that might otherwise be confused.
The ISNI is not intended to provide direct access to comprehensive information about a public identity but can provide links to other systems where such information is held.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    12 pages
    English language
    sale 15% off

IEC 63522-25:2025 Used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to check the magnetic interference between relays under operating conditions and their influence on other relays in the neighbourhood.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO/IEC 15459-3:2014 specifies the common rules applicable for unique identification that are required to ensure full compatibility across different identities.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off

This document specifies a method to determine the resistance to internal pressure of polyethylene (PE), crosslinked polyethylene (PE-X) and unplasticized (PA-U) pipes to verify the condition of the pipe after being subjected to a squeeze-off procedure.
The equipment and procedure used to prepare the test samples and test parameters are given in this document, i.e.:
a)   the diameter and series of the pipe to be tested (see 6.1);
b)   the number of test pieces (see 6.2);
c)   the parameters for the hydrostatic strength tests (see 7.6).
NOTE 1   Further information on the squeeze-off procedure is given in EN 12007-2 and ISO/TS 10839 for polyethylene, and CEN/TS 12007-6 for unplasticized polyamide.
NOTE 2   The squeeze-off procedure is specified to limit gas flow to allow maintenance, repair or to make network connections. Squeeze-off is used in an emergency for pipes carrying other media.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements, recommendations, and guidance on aspects of accessible systems for living independently (ASLI) in relation to technical solutions, service design, provision, and information. This includes adapting design and functionality of systems, to allow ease of use by any user, regardless of their abilities.
This document does not cover system-to-system communication.
This document is not applicable to household and similar electrical appliances covered by EN IEC 63008 [10].

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the dimensions, tolerances, required characteristics and the mass of an AWG 24 shielded quad cable, type KL, intended for high speed (100 Mbit/s) full duplex Ethernet networks.
Linked to this particular application, the operating temperatures of the cable are between −65 °C and 125 °C.
This cable is laser markable, this marking satisfies the requirements of EN 3838.
The characteristics impedance is 100 Ω ± 15 Ω.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1   Scope
1.1   General
The aviation, space, and defence industries rely on the development and manufacture of complex products comprised of multiple systems, subsystems, and components each designed by individual designers (design activities) at various levels within the supply chain. Each design or manufacturing activity controls various aspects of the configuration and specifications related to the product. When a change to design or process is requested or required, the change is typically required to be evaluated against the impacts to the entire system.
Proposed changes to design data/information that the design activity identifies to be minor and have no effect on the product requirements or specifications, have the potential to be implemented and approved, where authorized to do so, but requires notification. Changes that affect customer mandated requirements or specifications shall be approved prior to implementation. In many cases, the design activity is not conducted by the DAH or design authority. The design activity may be several layers below the design approval. Irrespective of where the design activity is conducted in the supply chain, notification is required. The typical change notification flow is presented in Figure 1.
[Figure 1]
Submitting NOC data either electronically or conventionally on paper is subject to the terms and conditions of the customer’s contract. This also includes, where applicable, data access under the regulations of export control.
The process of exchanging, coordinating, and approving NOC data varies with the multiple relationships and agreements among all organizations concerned. An objective of this document is to provide the definition of a data set that can be integrated into any form of communication (e.g. electronic data interchange, submission of conventional paper forms). A sample form can be found in the Supply Chain Management Handbook (SCMH).
If all or part of this document is contractually invoked, design organizations and design holders (i.e. the organization responsible for the product end item design) that have responsibility for change management of products used on other higher-level designs shall use the information and processes defined in this document for submitting change notifications.
1.2   Application
This document defines the common NOC requirements for aviation, space, and defence organizations. The requirements that a design organization are to use when submitting a NOC to the customer for either change authorization or notification are included herein. A NOC informs the customer of physical or functional (e.g. design, material, software, maintenance) changes or any associated process changes to an established baseline configuration.
Retention of the NOC establishes a means of configuration control and captures the evolution of the part. This requirement is of utmost importance in commercial/civil aviation products where changes to type certificated products are mandated by regulations; however, these same concepts are also required in defence and space applications per contractual requirements.
Where there are changes to items which the organization does not have design input or is not permitted to make any changes to the design [e.g. build to print, Technical Standard Order (TSO) articles] then change requests are to be formally submitted to the customer and approved via the customer’s change request process.
[...]

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-35:2025 is used for testing all kind of relays within the scope of technical committee 94 and evaluates their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for resistance to cleaning solvents.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day