Search Catalog

Standardization Organization
ICS
Technical Committee
Directive
Mandate

This document specifies procedures for the detection of a DNA sequence of a construct used to (genetically) enhance the growth of fish commonly found in aquaculture. The genetically modified AquAdvantage Atlantic salmon (Salmo salar) carries the construct expressing CS-GHc2 growth hormone and can be detected based on a real-time polymerase chain reaction (PCR) targeting either the border between the growth hormone coding sequence (CS-GHc2) of Oncorhynchus tshawytscha (Chinook salmon) and the antifreeze terminator (T-AFP) of (Macro-) Zoarces americanus (ocean pout), i.e. with the construct-specific method, or the border between the Atlantic salmon genomic DNA and the antifreeze promoter (P-AFP) of ocean pout, i.e. with the event-specific method. These methods can be applied to identify the genetically modified (GM) fish or for screening purposes.
This document is applicable for the analysis of DNA extracted from foodstuffs. It can also be suitable for the analysis of DNA extracted from other products such as feedstuffs. The application of these methods requires the extraction of an adequate amount of amplifiable DNA from the relevant matrix.

  • Technical specification
    19 pages
    English language
    e-Library read for
    1 day

IEC 60695-2-10:2026 specifies the glow-wire apparatus and common test procedure to simulate the effects of thermal stresses which may be produced by heat sources such as glowing elements or overloaded resistors, for short periods, in order to assess the fire hazard by a simulation technique. The test procedure described in this document is a common test procedure intended for the small-scale tests in which a standardized electrically heated wire is used as a source of ignition. It is a common part of the test procedures applied to end products and to solid electrical insulating materials or other solid combustible materials. A detailed description of each particular test procedure is given in IEC 60695-2-11, IEC 60695-2-12 and IEC 60695-2-13.
This fourth edition cancels and replaces the third edition published in 2021. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of 4.3 to add reference to new Annex D;
b) addition of new normative Annex D on "Use of pyrometer for glow-wire test";
c) revision of Clause 3 references to align with ISO 13943:2017.
It has the status of a basic safety publication in accordance with IEC Guide 104. This International Standard is to be used in conjunction with IEC 60695-2-11, IEC 60695-2-12, and IEC 60695-2-13.

  • Standard
    34 pages
    English language
    e-Library read for
    1 day

This document specifies a method for determining the content of wet gluten and the gluten index for wheat flours (Triticum aestivum L. and Triticum durum Desf.) by mechanical means.
This document is directly applicable to flours. It is also applicable to common and durum wheat after grinding, if their particular size distribution meets the specification given in Table B.1.
NOTE            This document is related to ICC 137/1[7], ICC 155[8] and AACC Method 38-12.02[9].

  • Standard
    37 pages
    English language
    e-Library read for
    1 day

The present document specifies technical characteristics and methods of measurements for magnetron-based inland waterways navigational radars having the following characteristics:
• Transmitter peak power not exceeding 10 kW.
• Operating on a pulse modulated single, non-tuneable carrier frequency in the range specified in Table 1.
• At the transmitter output, a 4 port RF-circulator or equivalent is used.
• The antenna is passive, rotating and waveguide based.
• The radar display is an integral part of the equipment.

  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    47 pages
    English language
    sale 15% off
  • Standard
    47 pages
    English language
    sale 15% off
  • Standard
    47 pages
    English language
    e-Library read for
    1 day

This document specifies the performance and the functional characteristics of the low voltage static uninterruptible power supply (SUPS) systems in a nuclear power plant (NPP) and, when applicable, in nuclear facilities in general. An uninterruptible power supply (UPS) is an electrical equipment which draws electrical energy from a source, stores it, and maintains the supply in a specified form by means inside the equipment to output terminals. A SUPS has no rotating parts to perform its functions.
The specific design requirements for the components of the power supply system are covered by IEC standards and other standards listed in the normative references. Otherwise, specific component-level design requirements are outside the scope of this document.

  • Standard
    41 pages
    English language
    e-Library read for
    1 day

This document specifies the characteristics of wheels for all heavy rail track gauges.
This document applies to heavy rail vehicles and applies, in principle, to other vehicles such as urban rail vehicles. Five steel grades, ER6, ER7, ER8, ERS8 and ER9, are defined in this document.
NOTE 1   Steel grade ERS8 has been introduced in this document as an optimization of steel grades ER8 and ER9 due to contact fatigue (RCF), taking into account service feedback from Europe, for example, BS 5892-3 in force in the United Kingdom.
Some features are provided as a Category 1 or Category 2 function.
The requirements defined in this document apply to cylindrical bores. Most requirements also apply to wheels with tapered bores. Specific requirements for tapered bores (e.g. geometrical dimensions, etc.) are defined in the technical specification.
This document applies to monobloc wheels in vacuum degassed steel, forged and rolled, with surface treated rims, which have already been the subject of extensive commercial applications on a European network or have complied with a technical approval procedure according to EN 13979-1:2020 to validate their design.
Annex A describes the evaluation process for accepting new materials that are not included in this document.
This document defines the requirements to be met for wheels; the technical approval procedure is not part of the scope of this document.
NOTE 2   A "surface-treated rim" is achieved by heat treatment which aims to harden the rim and create compressive residual stress.

  • Standard
    58 pages
    English language
    e-Library read for
    1 day

The present document defines the stage 3 specifications of the Supplementary Service Pre-emptive Priority Call (SS-PPC) for the Terrestrial Trunked Radio (TETRA). SS-PPC enables a user to have preferential access to the network resources in a TETRA system in times of congestion including pre-emption of calls. SS-PPC is applicable for pre-emptive priorities including the emergency priority. SS-PPC includes the capability to pre-empt resources needed for higher priority calls and the capability to pre-empt users from ongoing calls in order to move them to higher priority calls. SS-PPC specifies the definition, activation, deactivation and interrogation for the usage of pre-emptive call priorities in the TETRA system. The Switching and Management Infrastructure (SwMI) applies the SS-PPC priorities when it allocates the resources for calls. The SS-PPC operations are defined for the SwMI and for the Mobile Station (MS). SS-PPC is defined to subscribers of one TETRA system, but the subscribers may be located in several TETRA systems and the information flows may be delivered over the Inter System Interface (ISI). SS-PPC is invoked for calls within one TETRA system or for calls that extend over ISI to several TETRA systems. Man-Machine Interface (MMI) and charging principles are outside the scope of the present document. Supplementary Service stage 3 specification is preceded by the stage 1 and the stage 2 specifications of the service. Stage 1 describes the functional capabilities from the user's point of view. Stage 2 defines the functional behaviour in terms of Functional Entities (FEs) and information flows. Stage 3 gives a precise description of the supplementary service from the implementation point of view. It defines the protocol for the service and the encoding rules for the information flows. It defines the processes for the FEs and their behaviour. The described protocols and behaviour apply to the SwMI, for the MS and may be applied over the ISI between TETRA systems. Aspects relating to all supplementary services are detailed in ETSI EN 300 392-9 [3].

  • Standard
    67 pages
    English language
    sale 15% off
  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    66 pages
    English language
    e-Library read for
    1 day

This International Standard applies to runners of reaction turbines, regardless of their size and capacity. These can include radial turbines such as Francis turbines, axial turbines such as Kaplan and propeller turbines, as well as diagonal turbines, in all possible configurations. In the case of turbine runners with adjustable blades, the internal mechanical components of the blades' adjustment mechanism are excluded from this document. Pelton turbines, storage pumps and pump-turbines are not covered in this first edition, even though several topics are applicable to these types of hydraulic machines. Specificities and applicability to Pelton turbine and pump-turbines will be discussed in a later revision of the standard
This document outlines the methodologies for conducting a fatigue assessment of turbine runners. It encompasses several key aspects, such as defining the load events to be considered during the assessment, determining stresses for each of these load events, as well as the detailed approaches for assessing fatigue of new and existing runners. Additionally, it includes manufacturing and quality assurance requirements to be complied with to achieve the desired material fatigue properties and effectively apply the proposed fatigue assessment methodologies. This document also contains best practices for performing and analysing onsite strain gauge measurements performed on existing runners to evaluate their fatigue life.
The purpose of this document is to provide guidelines to assess fatigue in new and existing turbine runners. It does not specify if a fatigue assessment should be performed or not for a given runner. However, Annex B provides guidance to evaluate the necessity of realizing a fatigue assessment or not for a given new runner. The methods described in this document can also be used for remaining life assessments of in-service runners. However, it is important to consider that the assessed runner materials' fatigue properties and quality level could differ from the prescriptions found in the manufacturing and quality assurance section of this document which have been defined for new runners. It is also important to mention that fatigue assessment alone is not sufficient for a complete validation of the mechanical integrity of a new runner design. Other mechanical validations not covered in this document are typically conducted.

  • Standard
    47 pages
    English language
    e-Library read for
    1 day

IEC 60310:2026 specifies the terms and definitions, classification, service conditions, characteristics and test methods for transformers and inductors on board rolling stock. This document is applicable to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design. This document is also applicable to the traction transformers of three-phase AC line-side powered vehicles and to the transformers inserted in the single-phase or polyphase auxiliary circuits of vehicles, after agreement between purchaser and manufacturer. This document does not apply to instrument transformers, transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase, and inductors of a rated output below 1 kVAR single-phase or 5 kVAR poly-phase on board rolling stock. This document does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on transformers or inductors, which are tested separately according to the relevant rules. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) typical circuits for transformer and inductors are added; b) letter symbols for cooling methods are added; c) dielectric test table is modified; d) subclauses for the tests of transformers and inductors are restructured; e) temperature test for dry type transformer and dry type inductors are separated in different subclauses; f) requirements for shock and vibration tests are updated according to IEC 61373:20.

  • Draft
    71 pages
    English language
    e-Library read for
    1 day

IEC 60794-1-136:2026 specifies procedures to determine the maximum allowable push force applied on cables during the installation by blowing. Currently this parameter is determined by a separate test on the cable before installation. The methods specified in this document apply primarily to low-diameter cables (microduct cables according to IEC 60794-5) without rigid strength elements (e.g. GRP rods).

  • Draft
    12 pages
    English language
    e-Library read for
    1 day

IEC/IEEE 62395-2:2024 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications. This document does not include or provide for any applications in potentially explosive atmospheres. This standard cancels and replaces IEC 62395-2:2013. This edition constitutes a technical revision. This standard includes the following significant technical changes with respect to IEC 62395-2:2013: a) Design considerations for trace heating on sprinkler systems have been expanded and a figure has been added to illustrate how to avoid undue shadowing of spray patterns from insulated sprigs close to sprinkler heads; b) Specific details of design considerations for trace heating for emergency eyewash units and safety showers have been added.

  • Draft
    91 pages
    English language
    e-Library read for
    1 day

IEC 62321-3-1:2026 is available as IEC 62321-3-1:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 62321-3-1:2026 describes the screening analysis of substances, specifically lead (Pb), mercury (Hg), cadmium (Cd), total chromium (Cr), total bromine (Br), total phosphorus (P), assuming the source of P is related to TCEP (CAS 115‑96‑8), Trixylyl-phosphate (CAS 25155‑23‑1), total chlorine (Cl), assuming the source of Cl is related to SCCP (CAS 85535‑84‑8), TCEP (CAS 115‑96‑8) , TBTC (CAS 1461‑22‑9), total tin (Sn), assuming the source of Sn is related to restricted organo-tin compounds, total antimony (Sb), assuming the source of Sb is related to Pyrochlore, and antimony lead yellow (CAS 8012‑00‑8) in uniform materials found in electrotechnical products, using the analytical technique of X‑ray fluorescence (XRF) spectrometry. This edition includes the following significant technical changes with respect to the previous editions of IEC 62321-3-1:2013 and IEC 62321:2008: a) This second edition of IEC 62321-3-1 includes the analysis of additional elements as indicators for additional substances. The selection is based on IEC TR 62936:2016. There are also comments about using the same methology for screening for content of critical raw materials (CRMs). This document has been given the status of a horizontal document in accordance with the ISO/IEC Directives, Part 1.

  • Draft
    44 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-15:2026 applies to automatic electrical air flow, water flow and water level sensing controls - for use in, on, or in association with boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "automatic electrical air flow, water flow and water level sensing controls". EXAMPLE 1 Water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications. - for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS); EXAMPLE 2 Independently mounted air flow, water flow and water level sensing controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. - for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 3 Controls for commercial boilers, heating and air-conditioning equipment. - that are smart enabled controls; EXAMPLE 4 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; - utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; - using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; - that are mechanically or electrically operated, responsive to or controlling air flow, water flow and water level; - as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document applies to - the inherent safety of automatic electrical air flow, water flow and water level sensing controls, and - functional safety of automatic air flow, water flow and water level sensing electrical controls and safety related systems, - controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical air flow, water flow and water level sensing controls used in, on, or in association with an equipment. This document takes into account the response value of an automatic action of a control where such a response value is dependent upon the method of mounting the control. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate h

  • Draft
    44 pages
    English language
    e-Library read for
    1 day

IEC 60947-10:2026 applies to semiconductor circuit-breakers with a rated voltage up to 1 000 V AC or 1 500 V DC, intended to be installed and operated by instructed or skilled persons. This document covers the following different types: - semiconductor circuit-breakers (SCCBs) having semiconductor switching elements and, for isolation function, mechanical isolation contacts connected in series; - semiconductor hybrid circuit-breakers (SCHCBs) having semiconductor switching elements and mechanical switching elements in parallel and in addition, for isolation function, mechanical isolation contacts connected in series. In this document, where the term "circuit-breaker" only is used, it applies to both types. This document applies regardless of the rated currents, the method of construction or the proposed applications of the circuit-breakers. The object of this document is to state: a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply with reference to: 1) operation and behaviour in normal service; 2) operation and behaviour under specific abnormal circuit conditions (e.g. overload or short-circuit); 3) dielectric properties; 4) requirements on electromagnetic compatibility; c) tests intended for confirming that these conditions have been met and the methods to be adopted for these tests; d) information to be marked on or given with the circuit-breakers.

  • Draft
    123 pages
    English language
    e-Library read for
    1 day

IEC 60695-2-10:2026 specifies the glow-wire apparatus and common test procedure to simulate the effects of thermal stresses which may be produced by heat sources such as glowing elements or overloaded resistors, for short periods, in order to assess the fire hazard by a simulation technique. The test procedure described in this document is a common test procedure intended for the small-scale tests in which a standardized electrically heated wire is used as a source of ignition. It is a common part of the test procedures applied to end products and to solid electrical insulating materials or other solid combustible materials. A detailed description of each particular test procedure is given in IEC 60695-2-11, IEC 60695-2-12 and IEC 60695-2-13. This fourth edition cancels and replaces the third edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision of 4.3 to add reference to new Annex D; b) addition of new normative Annex D on "Use of pyrometer for glow-wire test"; c) revision of Clause 3 references to align with ISO 13943:2017. It has the status of a basic safety publication in accordance with IEC Guide 104. This International Standard is to be used in conjunction with IEC 60695-2-11, IEC 60695-2-12, and IEC 60695-2-13.

  • Standard
    34 pages
    English language
    e-Library read for
    1 day

IEC 63230:2026 applies to runners of reaction turbines, regardless of their size and capacity. These can include radial turbines such as Francis turbines, axial turbines such as Kaplan and propeller turbines, as well as diagonal turbines, in all possible configurations. In the case of turbine runners with adjustable blades, the internal mechanical components of the blades' adjustment mechanism are excluded from this document. Pelton turbines, storage pumps and pump-turbines are not covered in this first edition, even though several topics are applicable to these types of hydraulic machines. Specificities and applicability to Pelton turbine and pump-turbines will be discussed in a later revision of the standard This document outlines the methodologies for conducting a fatigue assessment of turbine runners. It encompasses several key aspects, such as defining the load events to be considered during the assessment, determining stresses for each of these load events, as well as the detailed approaches for assessing fatigue of new and existing runners. Additionally, it includes manufacturing and quality assurance requirements to be complied with to achieve the desired material fatigue properties and effectively apply the proposed fatigue assessment methodologies. This document also contains best practices for performing and analysing on-site strain gauge measurements performed on existing runners to evaluate their fatigue life. The purpose of this document is to provide guidelines to assess fatigue in new and existing turbine runners. It does not specify if a fatigue assessment should be performed or not for a given runner. However, Annex B provides guidance to evaluate the necessity of realizing a fatigue assessment or not for a given new runner. The methods described in this document can also be used for remaining life assessments of in-service runners

  • Standard
    47 pages
    English language
    e-Library read for
    1 day

IEC 63522-41:2026 provides guidelines for the insulation coordination of electromechanical elementary, solid state, time, forcibility guided and reed relays as well reed contacts and hybrid switching solutions. This document can also be used for similar devices when specified in a detail specification.

  • Draft
    26 pages
    English language
    e-Library read for
    1 day

See the scope of IEC 61225:2025. Adoption is to be implemented without modification.

  • Standard
    41 pages
    English language
    e-Library read for
    1 day

IEC 61643-361:2026 applies to surge isolation transformers (SITs) dedicated to surge mitigation and for connection to 50/60 Hz power circuits and equipment rated up to 1 000 V RMS. This document covers the surge and mitigation performance of SITs with an impulse withstand voltage performance of at least 30 kV, and provides standard methods for testing and rating. This document covers surge-related parameters but does not address typical transformer tests and parameters covered by the IEC 61558 series [13][1]. This document also does not cover SIT operation under differential mode lightning surge conditions. [1] Numbers in square brackets refer to the Bibliography.

  • Draft
    18 pages
    English language
    e-Library read for
    1 day

IEC 62196-3:2026 is applicable to vehicle couplers with pins and contact tubes of standardized configuration, herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage and current in accordance with IEC 62196-1:2025. This document applies to high power DC interfaces and combined AC/DC interfaces of vehicle couplers that are intended for use in conductive charging systems for circuits specified in IEC 61851-1 and IEC 61851-23. This third edition cancels and replaces the second edition published in 2022. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The content of IEC TS 62196-3-1 has been integrated into this document as normative Annex AA. b) increased ratings for all configurations; c) reference to new tests in IEC 62196-1:2025 (Clauses 34, 35, 36 and 37).

  • Draft
    139 pages
    English language
    e-Library read for
    1 day

IEC 61169-1-3:2026 is applicable to built-in devices (hereinafter referred to as "SPD" - surge protective device) or surge protection of telecommunications and signalling networks against indirect and direct effects of lightning or other transient over voltages. An SPD is intended to protect the electrical apparatus from transient over voltages and to divert surge currents. The SPD built in the coaxial connector can be a gas discharge tube type, a ¼ wavelength short stub type, a flash-off gap type, and a hybrid type thereof. The purpose of these built-in SPD is to protect modern electronic equipment connected to telecommunications and signalling networks with nominal system voltages up to 1 000 V (RMS) AC and 1 500 V DC.

  • Draft
    22 pages
    English language
    e-Library read for
    1 day

IEC/IEEE 62395-1:2024 specifies requirements for electrical resistance trace heating systems and includes general test requirements. This first edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes, apart from general revisions of IEC 62395-1 and harmonization with IEEE 515 [1] and IEEE 515.1 [2], with respect to the previous edition: a) Added control and monitoring requirements for fire sprinkler systems and safety showers. b) Provided a supplemental ice bath method for verification of rated output. c) Provided constructional and type test requirements for glands used to terminate heating devices to an exposed enclosure.

  • Draft
    67 pages
    English language
    e-Library read for
    1 day

IEC 60794-1-125:2026 specifies the ripcord functional test procedure used to measure the functionality of the cable ripcord. This first edition cancels and replaces cancels and replaces Method E25 of the first edition of the IEC 60794-1-21:2015.

  • Draft
    8 pages
    English language
    e-Library read for
    1 day

This document gives guidance on auditing management systems, including the principles of auditing, managing an audit programme and conducting management system audits, as well as guidance on the evaluation of competence of individuals involved in the audit process. These individuals include those managing the audit programme, auditors and audit teams.
It is applicable to all organizations that need to plan and conduct audits of management systems or manage an audit programme.
The application of this document to other types of audits is possible, provided that special consideration is given to the specific competence needed and the objectives to be achieved.

  • Standard
    56 pages
    English language
    e-Library read for
    1 day

IEC 60940:2026 establishes general rules and safety requirements on the application of capacitors, resistors, inductors, and complete filter units for electromagnetic interference suppression which will be connected to an AC mains or other supply (DC or AC) with a nominal voltage not exceeding 1 000 V AC having a nominal frequency not exceeding 400 Hz, or 1 500 V DC.
It facilitates drafters of product safety standards and other stakeholders such as designers, manufacturers, service providers, policy makers and regulators to consider safety aspects for the intended use and the reasonably foreseeable misuse of these components in its products and systems and apply risk reduction measures to achieve a tolerable risk level.
This third edition includes the following significant technical changes with respect to the previous edition:
a) new title to change the document from “guidance” into “general rules and safety requirements;
b) new content added (Clause 5 to Clause 9);
c) the previous edition is partly contained in Clause 4.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    29 pages
    French language
    sale 15% off

This document supplements or modifies the corresponding clauses in IEC 62841-1, so as to convert it into the IEC Standard: Particular requirements for transportable planers and thicknessers.
IEC 62841-1:2014, Clause 1 is applicable, except as follows:
This document applies to transportable planers, thicknessers and combined planers and thicknessers intended for cutting wood and analogous materials with a maximum planing width of 330 mm.
This document does not apply to planers, thicknessers or combined planers and thicknessers other than transportable.
NOTE 101 ISO 19085-7:2019 gives requirements for planers, thicknessers or combined planers and thicknessers other than transportable.

  • Standard
    38 pages
    English language
    e-Library read for
    1 day

This document specifies general interface requirements for small-bore connectors that form part of a medical device or accessory that conveys liquids or gases to a patient.
This document also identifies the applications for which these small-bore connectors are intended to be used, which include, but are not limited to:
—     respiratory;
—     enteral;
—     limb cuff inflation;
—     neural;
—     intravascular or hypodermic;
—     other use cases utilizing an ISO 80369-7 small-bore connector.
This document provides the methodology to assess non-interconnectable characteristics of small-bore connectors based on their inherent design in order to reduce the risk of misconnections between medical devices or between accessories for different applications as specified in this document as well as those that can be developed under future parts of the ISO and IEC 80369 series.
NOTE            Clause A.2 contains guidance or rationale for this Clause.

  • Standard
    55 pages
    English language
    e-Library read for
    1 day

This document specifies coupling between handpieces and motors that are connected to dental units. For the purposes of this document, the couplings described in this document are not equipped with electronic terminal(s).
This document specifies the nominal dimensions, tolerances and extraction force of coupling systems for use between handpieces and motor which supply the handpiece with water, air and light and rotation energy.

  • Standard
    23 pages
    English language
    e-Library read for
    1 day

This document specifies the requirements and methods for the clinical investigation of medical electrical (ME) equipment used to measure the body temperature in indirect measurement mode.
This document covers both intermittently and continuously measuring clinical thermometers.
NOTE 1        This document does not apply to clinical thermometers measuring the body temperature in direct measurement mode.
NOTE 2        For clinical thermometers in direct measurement mode determining the technical accuracy in accordance with ISO 80601-2-56:—1) is considered sufficient.
This document is applicable to clinical thermometers with claimed measurement time shorter than 60 seconds (for methods such as oral or rectal measurement), or shorter than 5 minutes (for methods such as axillary measurement), and which are treated as predictive type thermometers and fall under the scope of this document.
This document specifies additional disclosure requirements.
This document does not apply to the clinical investigation of a screening thermographs for human febrile temperature screening whose laboratory accuracy requirements are described in IEC 80601-2-59.
This document does not apply to pulmonary artery catheter for the determination of cardiac output by thermodilution.
NOTE 3        ISO 80601-2-56:—1) does include pulmonary artery catheter for the determination of cardiac output by thermodilution.

  • Standard
    33 pages
    English language
    e-Library read for
    1 day

This document specifies requirements and test methods for operating lights used in dental treatment and intended for illuminating the oral cavity of patients. It also contains specifications on the instructions for use, marking and packaging.
This document applies to operating lights, irrespective of the technology of the light source.
This document excludes auxiliary light sources and those intended for patient contact, e.g. from dental handpieces and dental headlamps, fibreoptic intraoral operating lights and operating lights which are specifically designed for use in oral surgery.

  • Standard
    34 pages
    English language
    e-Library read for
    1 day

IEC TS 63537:2026 addresses the requirements for hardware-in-the-loop (HIL) simulation test of power system stability control system (see definition in 3.1.2). Its purpose is to provide guidelines encompassing the use of terms and definitions, as well as the objective and general requirements for HIL simulation test. The TS covers the test requirements, test system, test contents, and test quality management. This document improves the safe and stable operation of the power system.

  • Technical specification
    17 pages
    English language
    sale 15% off

This document specifies requirements for oropharyngeal airways.
This document is not applicable to metal oropharyngeal airways, nor to requirements concerning flammability of oropharyngeal airways.
This document is not applicable to supralaryngeal airways, which are covered by ISO 11712[1].
The requirements that are also applicable to other airway devices have been removed from this document as they now appear in the general airway device standard (ISO 18190).
The requirements in this device-specific standard take precedence over any conflicting requirements in the general standard for airway devices (ISO 18190).

  • Standard
    22 pages
    English language
    e-Library read for
    1 day

This document provides requirements and specific guidance for the safe operation and maintenance of optical fibre communication systems (OFCSs). In these systems, optical power is possibly accessible outside the confines of the transmitting equipment and/or at great distance from the optical source.
This document requires the assessment of hazard level at each accessible location of the OFCS as a replacement for product classification according to IEC 60825-1. It applies to the installed OFCS as an engineered, end-to-end assembly for the generation, transfer and receipt of optical radiation arising from lasers, light-emitting diodes (LEDs) or optical amplifiers, in which the transference is by means of optical fibre for communication and/or control purposes.
NOTE 1 Throughout this document, a reference to 'laser' is taken to include LEDs and optical amplifiers.
Individual components and subassemblies that fall under the definition of a laser product are subject to the applicable subclause(s) of IEC 60825-1. This document is applicable to individual components and subassemblies intended to be installed within OFCSs.
This document does not apply to optical fibre systems primarily designed to transmit optical power for applications such as material processing or medical treatment.
In addition to the hazards resulting from laser radiation, OFCSs possibly give rise to other hazards, such as fire.
This document does not address safety issues associated with explosion or fire with respect to OFCSs deployed in explosive atmospheres.
NOTE 2 The hazard presented by optical radiation emerging from a fibre is determined by the wavelength and power emerging from the fibre and also by the optical characteristics of the fibre itself (see Annex A).

  • Standard
    61 pages
    English language
    e-Library read for
    1 day

IEC/IEEE 60802:2026 defines time-sensitive networking profiles for industrial automation. The profiles select features, options, configurations, defaults, protocols, and procedures of bridges, end stations, and LANs to build industrial automation networks. This document also specifies YANG modules defining read-only information available online and offline as a digital data sheet. This document also specifies YANG modules for remote procedure calls and actions to address requirements arising from industrial automation networks.

  • Standard
    220 pages
    English language
    sale 15% off

IEC TS 62607-6-24:2026 which is a Technical Specification, establishes a standardized method to determine the key control characteristic (KCC)
• number of layer distribution
for CVD graphene film by
• optical contrast measurement
The number of layers and number of layer distribution of CVD graphene film is derived by G‑channel contrast values.
This method is applicable for clean CVD graphene film without twisted multilayer structures on a SiO2/Si substrate.

  • Technical specification
    21 pages
    English language
    sale 15% off

IEC TS 63346-2-1:2026 establishes the general principles for the design of low-voltage auxiliary power systems (APS) with nominal voltages below or equal to 1 kV AC and 1,5 kV DC, and nominal frequency up to and including 60 Hz, so as to provide safe and correct operation for the intended use.
This document applies to the design of low-voltage auxiliary systems for
- substations, which are part of an electrical system, confined to a given area, mainly including ends of transmission or distribution lines, electrical switchgear and controlgear, buildings and transformers,
- converter stations,
- hydropower stations, where the gravitational energy of water is converted into electricity, and
- thermal power stations, where the thermal energy is obtained by burning fossil fuels.

  • Technical specification
    15 pages
    English language
    sale 15% off

ISO/IEC 14543-4-303:2026 specifies an application-layer protocol important for ensuring interoperability among the products of various manufacturers regarding communications between electric vehicle supply equipment (EVSE) chargers and controllers. It uses the network enhanced communications device (NECD) protocol specified in ISO/IEC 14543-4-3. This protocol is based on UDP using IPv4 or IPv6 (TCP is optional).

  • Standard
    34 pages
    English language
    sale 15% off

ISO/IEC 14543-4-304:2026 specifies an application-layer protocol important for ensuring interoperability among the products of various manufacturers regarding communications between electric vehicle supply equipment (EVSE) charger and dischargers and controllers. It uses the network enhanced communications device (NECD) protocol specified in ISO/IEC 14543-4-3. This protocol is based on UDP using IPv4 or IPv6 (TCP is optional).

  • Standard
    45 pages
    English language
    sale 15% off

IEC TS 63427:2026 provides principles and technical requirements for the adjustment potential of demand side resources in demand side management. Demand side resources include dispatchable loads, electrical energy storage, grid-connected microgrids, and distributed energy resources, which are connected to power distribution systems and capable of adjusting their operating state and exchanging information with grid control systems. It includes the DSR characteristics, system requirements, data preparation and evaluation process.
The adjustments of demand side resources can be subject to relevant local regulations or specifications. Electricity market mechanisms, user behaviour and data privacy are excluded from the scope of this document.

  • Technical specification
    27 pages
    English language
    sale 15% off

IEC 60079-10-2 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present in order to permit the proper assessment of ignition sources in such areas. In this document, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dust clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7, other general considerations for dust layers are described. The examples in this document are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this document can also be followed when combustible fibres or flyings might cause a hazard.
Atmospheric conditions include variations in pressure and temperature above and below reference levels of 101,3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosive properties of the combustible material. For air with normal oxygen content, typically a volume fraction of 21 % is assumed.
It does not apply to:
a) underground mining areas;
b) dusts of explosives that do not require atmospheric oxygen for combustion such as pyrophoric substances, propellants, pyrotechnics, munitions, peroxides, oxidizers, water‑reactive elements or compounds, or other similar materials;
c) catastrophic failures or rare malfunctions which are outside the conditions dealt with in this document;
d) rooms used for medical purposes;
e) domestic premises;
f) where a hazard is due to the presence of flammable gas or vapour, but the principles can be used in the assessment of a hybrid mixture (see also IEC 60079-10-1).
This document does not consider the effects of consequential damage following a fire or an explosion. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition.

  • Standard
    74 pages
    English language
    sale 15% off
  • Standard
    75 pages
    English and French language
    sale 15% off
  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 60404-8-3:2023 defines the grades of cold-rolled non-oriented electrical steel strip and sheet delivered in the semi-processed state in nominal thicknesses of 0,47 mm, 0,50 mm, 0,64 mm, 0,65 mm and 0,79 mm. It gives general requirements, magnetic properties, geometric characteristics, tolerances and technical characteristics as well as inspection procedures. The nominal thicknesses of 0,47 mm, 0,64 mm and 0,79 mm apply to the grades for use at 60 Hz only.
This document applies to cold-rolled non-oriented electrical steel strip and sheet delivered in the semi-processed state, i.e. without final heat treatment, in coils or sheets, and intended for the construction of magnetic circuits. This document does not apply to materials supplied in the fully-processed state.
These materials correspond respectively to classes B2 and C21 of IEC 60404-1.
This edition includes the following significant technical changes with respect to the previous edition:
a) Modification of terms and technical requirements concerning geometrical characteristics to be consistent with IEC 60404-9:2018;
b) Insertion of Table 3 – Tolerances on nominal thickness;
c) Change of the length of the test specimen for determination of geometrical characteristics from 2 m to 1 m;
d) Deletion of Annex A with the European numerical system of designation of steels.

  • Standard
    44 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English and French language
    sale 15% off

IEC 60404-8-4:2022 defines the grades of cold-rolled non-oriented electrical steel strip and sheet in nominal thicknesses of 0,35 mm, 0,47 mm, 0,50 mm, 0,65 mm and 1,00 mm. In particular, it gives general requirements, magnetic properties, geometric characteristics, tolerances and technological characteristics, as well as inspection procedure. The nominal thickness 0,47 mm applies to the grades for use at 60 Hz only. This document applies to cold-rolled non-oriented electrical steel strip and sheet supplied in the fully-processed state, i.e. the final annealed condition, in coils or sheets, and intended for the construction of magnetic circuits. This document does not apply to materials supplied in the semi-processed state. This edition includes the following significant technical changes with respect to the previous edition:
- modification of terms and technical requirements concerning geometrical characteristics to be consistent with IEC 60404-9:2018;
- insertion of Table 3 - Tolerances on nominal thickness;
- change of the length of test specimen for determination of geometrical characteristics from 2 m to 1 m.

  • Standard
    80 pages
    English language
    sale 15% off
  • Standard
    50 pages
    English language
    sale 15% off
  • Standard
    52 pages
    English and French language
    sale 15% off

IEC 61995-1:2025 applies to devices for the connection of luminaires (DCL) intended for household and similar purposes, for the electrical connection of fixed luminaires of class I or class II to final circuits rated at not more than 16 A without mechanical support for the luminaires incorporated in the plug/outlet interface. The DCL retention mechanisms are not intended to support the weight of the luminaires. This second edition cancels and replaces the first edition published in 2005 and Amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) additional requirements and tests for additional suspension means; b) additional requirements and tests for additional functions; c) additional requirements and tests for floating type DCLs; d) introduction of insulation piercing terminals (IPT); e) additional classification according to the connection capacities of the DCL outlet terminals; f) modification of maximum withdrawal force for plugs with enabled locking means; g) improvements of temperature rise tests.

  • Draft
    84 pages
    English language
    e-Library read for
    1 day

This document specifies requirements and gives recommendations for the periodic inspection and testing of permanently mounted tubes of: composite with seamless metallic liners; composite with non-load-sharing liners; seamless steel; in battery vehicles and multiple element gas containers (MEGCs) including frames and associated equipment (these components are also inspected); and large tubes of: composite with seamless metallic liners; composite with non-load-sharing liners; in modules including frames and associated equipment (these components are also inspected).

  • Standard
    33 pages
    English language
    sale 15% off

IEC 61754-2: 2026 defines the standard interface dimensions for type BFOC/2,5 family of connectors. This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of Clause 2, Clause 3 and the Bibliography; b) addition of the active device receptacle interface type; c) revision of the ferrule grades to refer to the connector optical interfaces specified in the IEC 61755-3 series; d) revision of the ferrule end face geometry to refer to the connector optical interfaces specified in the IEC 61755‑3 series and IEC 63267‑3 series; e) improvement of the description of the characteristics of the resilient alignment sleeve for adaptor and rigid bore sleeve for active device receptacle; f) harmonisation of the dimensions of reference A for the rigid bore sleeve with other connector interface standards in IEC 61754 series.

  • Draft
    12 pages
    English language
    e-Library read for
    1 day