Search Catalog
This document specifies the additional technical delivery conditions for castings made from all cast iron materials.
This document applies to iron castings produced in sand or permanent moulds or by centrifugal casting, continuous casting or investment casting.
- Standard17 pagesEnglish languagee-Library read for1 day
This document deals with electroplating process evaluation for fasteners, including fastener expected coating properties.
This document is a complement to CQI-11 in order to deal with fastener specific aspects not fully covered by CQI-11, and to clarify some questions/items when they are not fully suitable for fasteners.
This document is applicable to all parties involved in the supply chain for coated fasteners, i.e. fastener manufacturers, chemical suppliers, electroplaters and purchasers.
The requirements for electroplating fasteners specified in this document are essentially based on ISO 4042, ISO/TR 20491 and ISO 16047.
NOTE Requirements for electroplating fasteners are also given in ASTM F1941/F1941M.
- Technical specification26 pagesEnglish languagee-Library read for1 day
- National annex4 pagesSlovenian languagee-Library read for1 day
This document specifies the requirements and test methods for external tooth bleaching products. These products are intended for use in the oral cavity, either by professional application (in-office tooth bleaching products) or consumer application (professional or non-professional home use of tooth bleaching products) or both. It also specifies requirements for their packaging, labelling and manufacturer’s instructions for use.
This document is not applicable to tooth bleaching products:
specified in ISO 11609;
intended to change colour perception of natural teeth by mechanical methods (e.g. stain removal) or using restorative approaches, such as veneers or crowns;
auxiliary or supplementary materials (e.g. tray materials) and instruments or devices (e.g. lights) that are used in conjunction with the bleaching products.
This document does not specify biological safety aspects of tooth bleaching products.
NOTE The maximum concentration of a bleaching agent for professional or non-professional use is subject to each country’s regulatory body.
- Standard27 pagesEnglish languagee-Library read for1 day
This document specifies the technical delivery requirements for seamless and welded butt-welding fittings (elbows, concentric and eccentric reducers, equal and reducing tees, caps) made of austenitic and austenitic-ferritic (duplex) stainless steel without specific inspection requirements.
This document specifies:
— steel grades and their chemical compositions;
— mechanical properties;
— dimensions and tolerances;
— requirements for inspection and testing;
— inspection documents;
— marking;
— handling and packaging.
- Standard65 pagesEnglish languagee-Library read for1 day
This document provides product category rules (c-PCR), that are complementary to EN 15804:2012+A2:2019, for Type III environmental declarations for sandwich panels within the scope of EN 14509 1:— and EN 14509 2:—, which are used for non-structural and structural purposes in building envelopes and for sandwich panels with perforated faces and for sandwich panels with core materials others than defined in EN 14509 1:— and EN 14509 2:—.
Manufactured on industrial plant, double skin metal faced insulating sandwich panels are designed to be laid with overlapping edges in the following applications:
— roofs and discontinuous roofing;
— outer walls and wall cladding;
— walls (incl. partition walls) and (suspended) ceilings inside the building envelope.
This document is intended to be used cradle-to-grave, declaring modules A1-A3, modules C1-C4 and module D, according to EN 15804:2012+A2:2019
NOTE The assessment of social and economic performances at product level is not covered by this document.
- Standard33 pagesEnglish languagee-Library read for1 day
This document specifies requirements and technical specifications for information presented in tactile lettering in the built environment.
NOTE For the definition of built environment see ISO 21542.
It sets out rules for content, design, arrangement and application of information elements so that blind and partially sighted people are able to locate, identify, fluently read and interpret this information.
This document does not specify technical methods for producing tactile lettering.
This document is only applicable to permanently installed tactile lettering.
- Standard28 pagesEnglish languagee-Library read for1 day
1.1 This document specifies the minimum requirements for safety and performance of some optional specific permanently installed equipment on firefighting and rescue service vehicles, operated by trained persons, as designated in EN 1846 1:2011 and specified in EN 1846 2:2024.
NOTE 1 Categories and mass classes of these vehicles are given in EN 1846 1:2011.
NOTE 2 Vehicle means ground vehicles which can also drive on rails and amphibious vehicles.
The permanently installed equipment covered by this document is given below:
- water installation;
- additive installation;
- monitor;
- equipment gantries;
- demounting systems.
This document covers also the use of wireless control systems.
NOTE 3 This document is assumed to be read in conjunction with any national regulations in force for vehicles using the public roads and with any EU Directives and associated EFTA regulations in force relevant to vehicles and their equipment.
For the purposes of this document, the normal ambient temperature range is –15 °C to +40 °C.
For equipment to be used at temperature outside this temperature range, the particular temperature range is specified by the user. A risk assessment determines any need for additional precautions.
1.2 This document does not deal with the following types of equipment:
- all control systems outside of the cabin related to hook arm system;
- provisions for non-firefighting removable equipment driven by PTO.
1.3 This document deals with the technical requirements to minimize the hazards listed in Annex A which can arise during operational use, routine checking and maintenance of firefighting and rescue service vehicles.
It does not cover the hazards generated by:
- non-permanently installed equipment i.e. portable equipment carried on the vehicle;
- use in potentially explosive atmospheres;
- commissioning and decommissioning;
- noise (as permanently installed equipment cannot be operated separately from the vehicle, this hazard is covered in EN 1846 2:2024);
- electromagnetic compatibility;
- cyber security;
- cyber safety.
Additional measures not dealt with in this document can be necessary for specific use (e.g. fire in natural environment, flooding, etc.).
1.4 This document is not applicable to the equipment which is manufactured before its date of publication by CEN.
- Standard60 pagesEnglish languagee-Library read for1 day
This document specifies performance requirements for portable fire extinguishers in addition to the requirements of EN 3 7, to demonstrate their suitability for extinguishing fires in rechargeable batteries based on lithium-ion chemistry with a maximum capacity of 600 Wh, as used for example:
— portable electronic equipment (smartphones, laptops);
— power tools and domestic appliances;
— portable medical equipment;
— toys and radio-controlled objects;
— drones;
— bicycles.
This document contains general requirements and procedures for extinguishing tests. The size of the extinguishing tests is comparable to the battery capacities in the above mentioned applications where the battery is accessible. This document doesn’t apply to larger fire risks, such as vehicle batteries, fork lift trucks, and battery sets of stationary energy storage systems.
- Standard18 pagesEnglish languagee-Library read for1 day
This document specifies a spectrometric method for the determination of the chlorophyll content of rapeseed. It is not applicable to the determination of chlorophyll in oils.
- Standard16 pagesEnglish languagee-Library read for1 day
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
- Standard7 pagesEnglish and French languagesale 15% off
- Corrigendum4 pagesEnglish languagee-Library read for1 day
- Corrigendum8 pagesEnglish languagee-Library read for1 day
This document applies to switching device for islanding, hereafter referred to as SDFI, for household and similar uses, primarily intended to be used for energy efficiency (EE) purposes with local production or local storage of energy, or with both.
SDFI are intended to be installed in low voltage prosumer electrical installations (PEI) able to operate in island mode as defined in IEC 60364-8-82, so called islandable PEI.
SDFI are used to disconnect the PEI from the grid to allow operating the PEI in island mode and further reconnect the PEI to the grid.
They are intended to be used in islandable PEI which operate:
– in connected mode (direct feeding mode or reverse feeding mode), and
– in island mode,
as defined in IEC 60364-8-82.
NOTE 1 See definitions 3.10 and 3.13 of island mode and for connected mode respectively.
NOTE 2 Switching of a PEI to island mode can be subject to local regulations (grid codes) or to specific agreement with system operators. Reverse feeding is also usually subject to local regulations (grid codes). SDFI are part of the electrical installation.
This document applies to SDFI for operation in AC single or multiphase main circuits with rated voltages not exceeding 440 V AC, frequencies of 50 Hz, 60 Hz or 50/60 Hz. They are intended to be used in installations with prospective short circuit currents not exceeding 25 000 A.
NOTE 3 DC operations are not covered by this edition and are kept under consideration for a future revision of this document.
The SDFI is composed at least of one switching unit (SU) and a control unit (CU) to monitor its switching operations from grid connected to island mode and reverse wise.
The SDFI can be provided with a communication interface for exchange with external systems such as the Customer Energy Manager (CEM) defined in IEC 63402 series.
According to the intended use, the SDFI can be interlocked with a system referencing conductor switching device (SRCSD) according to IEC 63445 or it can be integrated with a SRCSD in a single unit.
NOTE 4 According to its intended use, the SDFI can also be used as an interface switch with the interface protection (integrated or not). See 3.19 and 3.20.
SDFI are intended for use in circuits where protection against electrical shock and overcurrent is provided according to installation rules for low voltage electrical installations, unless the SDFI already contains such protective function. SDFI are not requested to provide isolation function and overcurrent protection according to IEC 60364-8-82. However, the isolation function can be provided by a SDFI fulfilling the requirements of the relevant product standards.
SDFI are installed by instructed persons (IEC 60050-195:2021, 195-04-02) or skilled persons (IEC 60050-195:2021, 195-04-01). They are intended to be used by ordinary persons (IEC 60005-195:2021, 195-04-03) and do not require maintenance.
It is important to note that the main overcurrent protective device of installations cannot be used as a SDFI in single dwellings or similar islandable PEI (see Clause D.5 of IEC 60364-8-82:2022)
- Standard35 pagesEnglish languagee-Library read for1 day
This part of IEC 61058 applies to switches or switching devices for appliances. The switches are intended to control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 600 V and a rated current not exceeding 63 A.
In the IEC 61058 series the terms "switching devices" and "switches" are used interchangeably.
Switches for appliances are intended to be operated by
– a person via an actuating member,
– indirect actuation,
– an actuating sensing unit.
Transmission of a signal between the actuating member or sensing unit and the switch can be connected by optical, acoustic, thermal, electrical or other relevant connection and can include remote controlled units.
This document applies to switches for appliances with additional control functions provided by the switch using electronic circuits.
This document applies to circuitry when evaluated with a switch and necessary for the switching function.
This part document applies in general to switches for appliances in conjunction with the following parts:
– Part 1-1: Requirements for mechanical switches, and/or
– Part 1-2: Requirements for electronic switches.
This document does not apply to switches covered by:
– IEC 60669 (all parts), Switches for household and similar fixed-electrical installations, and
– IEC 60730 (all parts), Automatic electrical controls.
NOTE 1 Attention is drawn to the fact that the end product standards for appliances can contain additional or alternative requirements for switches (see Annex O).
NOTE 2 Throughout this document, the word "appliance" means "appliance or equipment".
- Standard131 pagesEnglish languagee-Library read for1 day
- Corrigendum4 pagesEnglish languagee-Library read for1 day
The purpose of this document is to describe product classes and properties, representing the miniature circuit-breaker (MCB), to become a part of the IEC 61360-4: IEC Common Data Dictionary (IEC CDD). It includes data required for product selection as well as data required for engineering.
This document intends, as a contribution to the IEC Common Data Dictionary, to be used by catalogue consortia, other database standards and software as a data reference for circuit-breakers and similar equipment for household use.
NOTE In the future, it is intended to extend the IEC 63508 DB to other types of products e.g. arc fault detection devices (AFDDs), residual current circuit breakers (RCCBs), residual circuit breaker with overcurrent protection (RCBOs).
- Standard35 pagesEnglish languagee-Library read for1 day
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
The contents of the corrigendum of November 2023 have been included in this copy.
- Standard196 pagesEnglish languagee-Library read for1 day
- Standard196 pagesEnglish languagesale 15% off
- Standard410 pagesEnglish and French languagesale 15% off
IEC 62196-3:2026 is applicable to vehicle couplers with pins and contact tubes of standardized configuration, herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage and current in accordance with IEC 62196-1:2025.
This document applies to high power DC interfaces and combined AC/DC interfaces of vehicle couplers that are intended for use in conductive charging systems for circuits specified in IEC 61851-1 and IEC 61851-23.
This third edition cancels and replaces the second edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The content of IEC TS 62196-3-1 has been integrated into this document as normative Annex AA.
b) increased ratings for all configurations;
c) reference to new tests in IEC 62196-1:2025 (Clauses 34, 35, 36 and 37).
- Standard151 pagesEnglish languagee-Library read for1 day
- Amendment9 pagesEnglish languagee-Library read for1 day
IEC 61995-1:2025 applies to devices for the connection of luminaires (DCL) intended for household and similar purposes, for the electrical connection of fixed luminaires of class I or class II to final circuits rated at not more than 16 A without mechanical support for the luminaires incorporated in the plug/outlet interface. The DCL retention mechanisms are not intended to support the weight of the luminaires.
This second edition cancels and replaces the first edition published in 2005 and Amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) additional requirements and tests for additional suspension means;
b) additional requirements and tests for additional functions;
c) additional requirements and tests for floating type DCLs;
d) introduction of insulation piercing terminals (IPT);
e) additional classification according to the connection capacities of the DCL outlet terminals;
f) modification of maximum withdrawal force for plugs with enabled locking means;
g) improvements of temperature rise tests.
- Standard89 pagesEnglish languagee-Library read for1 day
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
The contents of the corrigendum of November 2023 have been included in this copy.
- Standard1 pageEnglish and French languagesale 15% off
- Corrigendum1 pageFrench languagee-Library read for1 day
This document applies to docking connectors (hereinafter referred to as accessories) incorporated in or fixed to electrical equipment, intended to connect energy storage units, either removable or swappable, or both, to a dedicated electric power conversion unit, to an energy consuming unit or to another energy storage unit.
These accessories are intended for DC and can include either a protective earth contact or optional auxiliary contacts for signalling and data transmission, or both. These accessories have a rated current of up to 2 000 A and rated operating voltages not exceeding 1 500 V DC.
This document also applies to accessories intended to be used at extra-low voltage.
The list of preferred ratings is not intended to exclude other ratings.
These accessories are not suitable for mating or unmating under load. These accessories are intended to be installed by instructed persons (IEC 60050-195:2021, 195-04-02) or skilled persons (IEC 60050-195:2021, 195-04-01) only.
This document applies to accessories for use under environmental conditions as described in Clause 31.
These accessories are intended to be connected to current carrying parts in copper or copper
alloy only, plated or not plated.
In locations where special conditions prevail, additional requirements can apply.
NOTE For conditions other than operation, additional requirements can be applicable, for instance, IEC 62133 (all parts) and UN Recommendations on the Transport of Dangerous Goods (2002), section 38.338.3.
- Standard71 pagesEnglish languagee-Library read for1 day
The OpRa scope is the definition of a minimum set of Public Transport raw data needed to enable PT quantitative analysis.
OpRa does not go into the domain of service quality measurement and reporting: service quality analysis will use data provided by OpRa, but quality definition remains a contractual level issue between a Public Transport Authority and a Public Transport Operator or an operator’s internal choice for a purely private service. OpRa reports unbiased actual data (i.e. measured or observed), described and aggregated in a shared and understandable way.
OpRa focuses mainly on observed/measured and registered information, i.e. information which cannot be changed anymore in the future. This information is mainly an output of the domain “operations monitoring & control" as defined by Transmodel.
Based on the actual service, including delays and cancelled vehicle journeys, etc., OpRa considers the recorded reality of operation, either through individual observed and registered data at a given sampling interval (raw data) or in an aggregate way (indicators) and provides the data exchange format.
The approach documented in detail in this document is coherent with EU Directive 2010/40. It relates to the Article 4 of the Delegated Regulation EU 2017/1926 [16], as regards the historic data. OpRa proposes to complement NeTEx (dedicated to the static scheduled information), for the historic data, based on the underlying conceptual data reference model Transmodel EN 12896, similarly to the requirement of the Delegated Regulation EU 2017/1926 referring to the static scheduled information2.
- Technical specification225 pagesEnglish languagee-Library read for1 day
IEC 60115-8-10:2026 is applicable to the drafting of detail specifications for surface mount (SMD) low-power film resistors, classified to level G, based on the definition of the product classification levels in IEC 60115‑1:2020, 3.4. This edition includes the following significant technical changes with respect to the previous edition IEC 60115‑8‑1:2014: a) it supports solderability testing for both traditional lead-bearing soldering and up-to-date lead-free soldering, as required; b) it supports the provision of detailed visual acceptance criteria; c) it includes the requirement for a visual examination of the primary and proximity packaging; d) it provides for the inclusion of specific visual acceptance criteria, to be applied in addition to those given in Annex B of the sectional specification IEC 60115‑8:2023.
- Draft48 pagesEnglish languagee-Library read for1 day
This document specifies requirements for process development for forming, sealing and assembly of packaging for medical devices to be terminally sterilized, when utilizing heat sealing technologies.
This document recommends minimum heat sealing equipment features to support subsequent validation, process control and monitoring.
This document applies to both preformed sterile barrier systems and sterile barrier systems.
This document utilizes the sterile barrier system specification to develop the process specification using the principles of risk management.
This document is intended to be used prior to process validation.
NOTE ISO 11607-2 provides requirements for process specification and process validation.
- Standard35 pagesEnglish languagee-Library read for1 day
This document establishes the air interface for radio frequency identification (RFID) devices operating in the 860 MHz to 930 MHz industrial, scientific and medical (ISM) band used in item management applications. This document specifies a common technical specification for RFID devices that can be used to develop standards for applications using this radio identification (RAIN) air interface. This document is intended to improve compatibility and encourage inter-operability of products for the growing RFID market in the international marketplace. This document establishes the forward and return link parameters for technical attributes including, but not limited to, operating frequency, operating channel accuracy, occupied channel bandwidth, maximum effective isotropic radiated power (EIRP), spurious emissions, modulation, duty cycle, data coding, bit rate, bit rate accuracy, bit transmission order, and, where appropriate, operating channels, frequency hop rate, hop sequence, spreading sequence, and chip rate. This document further specifies the communications protocol used in the air interface. This document describes the physical and logical requirements for a passive backscatter, Interrogator-talks-first (ITF), radio frequency identification system operating in the 860 MHz to 930 MHz frequency range. This document specifies: physical interactions (the signalling layer of the communication link) between Interrogators and Tags; logical operating procedures and commands between Interrogators and Tags; the collision arbitration scheme used to identify a specific tag in a multiple-tag environment; optional security commands that allow the use of crypto suites of ISO/IEC 29167-1:2014.
- Standard366 pagesEnglish languagesale 15% off
- Draft84 pagesEnglish languagee-Library read for1 day
The present document is composed of the following data packages:
— Indicators;
— Reusable components;
— Explicit frames for statistics
— Query.
This document itself is composed of the following parts:
— main document representing the conceptual foundations and corresponding data model (normative);
— Annex A containing the data dictionary and attribute tables, i.e. the list of all the concepts presented in the main document together with their definitions (normative);
— Annex B presenting the model evolution (informative);
— Annex C, providing details of the significant technical changes between this document and EN 12896-8:2019 (informative)
- Standard104 pagesEnglish languagee-Library read for1 day
This document applies to photovoltaic (PV) system components and communication networks supporting the communication of the DC shutdown equipment using power line communication.
This document defines how to propagate the operational state of the entire PV system (normal / shutdown) to the individual power production components comprising the PV system. The document also describes requirements and constraints associated with power line communication networks that are used to support this application.
NOTE 1 It is possible to have systems communicating in different ways to the method covered in this document.
E.g., in systems where all components of the PLC communication are from the same manufacturer. For those systems this document does not apply.
NOTE 2 Not included in the scope of this document are requirements for DC shutdown initiator mechanism, disconnection and de-energization.
NOTE 3 This document does not address whether DC shutdown is required or not.
NOTE 4 EMC requirements are not included in this document.
- Standard60 pagesEnglish languagee-Library read for1 day
- Amendment12 pagesEnglish languagee-Library read for1 day
IEC 61851-23:2023 applies to the EV supply equipment to provide energy transfer between the supply network and electric vehicles (EVs), with a rated maximum voltage at side A of up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B up to 1 500 V DC.
This document specifies the EV supply equipment of system A, system B and system C as defined in Annex AA, Annex BB and Annex CC. Other systems are under consideration.
This document provides the requirements for bidirectional power transfer (BPT) EV supply equipment for system A, with a rated maximum voltage at side A up to 1 000 V AC or 1 500 V DC. The requirements for reverse power transfer (RPT) and BPT for system B and system C are under consideration and are not specified in this document.
This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the structure has been rearranged according to IEC 61851-1:2017;
b) electrical safety requirements in Clause 8 and Clause 12 have been revised based on the requirements in IEC 62477-1 and inspired by the hazard based safety approach of IEC 62368-1;
c) test methods for checking conformity to the stated requirements have been mostly added; general provisions for compliance tests have been specified in Clause 102;
d) specific requirements and/or information for the following functions have been added: energy transfer with thermal management system (101.2), bi-directional power transfer control (Annex DD), multi- side B separated EV supply equipment (Annex FF), and communication and energy transfer process (Annex GG);
e) Annex AA (system A), Annex BB (system B) and Annex CC (system C) have been updated including additions in conjunction with b) and c). This document has been limited to be applicable to system A, system B and system C;
f) the former Annex DD and Annex EE have been deleted. A new Annex EE, with the requirements for the artificial test load, has been added.
g) a new informative annex for the touch current and the touch impulse current (Annex HH) has been added
- Standard391 pagesEnglish languagee-Library read for1 day
- Draft73 pagesEnglish languagee-Library read for1 day
- Draft23 pagesEnglish languagee-Library read for1 day
The CEN 16157 multipart standard specifies and defines component aspects supporting the shared use of data and information in the field of traffic and travel. The component aspects include the modelling approach, the data content, the data structure and relationships and the communications specification.
This document defines a mapping from UML models, compliant with EN 16157-1, into JavaScript Object Notation (JSON) using JSON Schema as specified in draft 2020-12 and subsequent versions.
The schema mapping conforms to the JSON format defined by the Internet Engineering Task Force (IETF) in RFC 8259.
In the context of describing generation of schema, this refers to the webtool made available as part of the CEN 16157 multipart standard, which can generate the JSON schema mapping specified in this document.
- Technical specification20 pagesEnglish languagee-Library read for1 day
NOTE Throughout this standard, the abbreviation ACS (ASSEMBLY for construction site, see 3.1.101) is used for a low-voltage switchgear and controlgear assembly intended for use on construction and similar sites. This part of 61439 defines the specific requirements of ACS as follows: - ASSEMBLIES for which the rated voltage does not exceed 1 000 V in case of AC or 1 500 V in case of DC; - ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above; - ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out; - transportable (semi-fixed) or mobile ASSEMBLIES with enclosure. The manufacture and/or assembly may be carried out other than by the original manufacturer. This standard does not apply to individual devices and self-contained components, such as motor starters, fuse switches, electronic equipment, etc. which will comply with the relevant product standards. This standard does not apply to ASSEMBLIES for use in the administrative centres of construction sites (offices, cloakrooms, ASSEMBLY rooms, canteens, restaurants, dormitories, toilets, etc.). Requirements for electrical protection provided by equipment manufactured according to this International Standard are given in IEC 60364-7-704.
- Draft29 pagesEnglish languagee-Library read for1 day
This part of IEC 63223 series [2] provides an overview of asset management, its principles and value creation options for the management of network assets in power systems.
This document can be applied to all types of network assets and by all types and sizes of power network companies. The term power network company does not necessarily refer to legally structured companies.
In this document, network assets refer mainly to the physical assets of the electrical energy network, meaning items, equipment, or systems that have potential or actual value for the electric company and are part of the power lines and substations responsible for the transmission and distribution of electrical energy. Examples of network assets that can be included in the asset portfolio of a power network company are presented in IEC 63223-2:2026 [6], 4.2.2.
- Standard25 pagesEnglish languagee-Library read for1 day
- Amendment10 pagesEnglish languagee-Library read for1 day
This part of IEC 62146 includes generalities of capacitors used on alternating current circuitbreakers and introduces specifications for grading capacitors. Regarding grading capacitors, their function is to control the voltage distribution across the individual interrupter units of a multi-break circuit-breaker.
Capacitors can also be used in parallel to the interrupter unit on single break circuit-breakers to modify the Transient Recovery Voltage (TRV). This TRV capacitor application is covered by IEC 62146-2:2023.
Capacitors for high-voltage alternating circuit breakers are sub-components for the circuitbreaker and are specified in accordance with the circuit-breaker specifications according to IEC 62271-1, IEC 62271-100, and if applicable to IEC 62271-203.
This document applies to grading capacitors falling into one or both of the following categories for:
− mounting on air-insulated circuit-breakers.
− mounting on enclosed circuit-breakers (for example immersed in insulating gas, in oil, etc.).
The testing for each of the above applications is in some cases different.
The object of this document is:
− to define uniform rules regarding performances, testing and rating;
− to define specific safety rules;
− to provide a guidance for installation and operation.
NOTE CIGRÉ TB-368 presents a study about the operating environment of voltage grading capacitors applied to high-voltage circuit-breakers (see [2]1).
This document does not apply to capacitors not directly associated with high-voltage alternating current circuit-breakers.
- Standard46 pagesEnglish languagee-Library read for1 day
This part of IEC 63287 gives guidelines for the development of reliability qualification plans using the early failure assessment, based on the environmental conditioning and
proposed usage of the product. This document is not intended for military- and spacerelated applications.
- Standard19 pagesEnglish languagee-Library read for1 day
This document provides background information, rationale, and technical guidance supporting the 15427 series of standards and technical specifications for wheel/rail friction management. It is intended for users who are unfamiliar with friction management, those who are involved in specifying friction management materials and/or application equipment for trainborne or trackside application, or those who are responsible for vehicle or track maintenance. Users also include the friction management supply industry.
Key items described in this document include:
— Fundamental principles of the wheel/rail interface, adhesion, friction behaviour, and common issues such as noise, wear, corrugation, and low adhesion.
— The purpose, function, and performance of friction management materials, including flange lubricants, top of rail materials, and adhesion enhancers.
— An overview of trackside and trainborne application technologies, including equipment options, selection criteria, and operational factors.
— General guidance on maintenance, operational strategy, environmental considerations, and safe implementation of friction management systems.
Testing and trialling methods, and performance considerations for evaluating friction management solutions.
Overall, the document acts as a technical reference for understanding the rationale behind requirements, correct application of friction management solutions, and their role in achieving safe, reliable, and efficient railway operations.
- Technical report175 pagesEnglish languagee-Library read for1 day
IEC/IEEE 62395-1:2024 specifies requirements for electrical resistance trace heating systems and includes general test requirements. This first edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes, apart from general revisions of IEC 62395-1 and harmonization with IEEE 515 [1] and IEEE 515.1 [2], with respect to the previous edition: a) Added control and monitoring requirements for fire sprinkler systems and safety showers. b) Provided a supplemental ice bath method for verification of rated output. c) Provided constructional and type test requirements for glands used to terminate heating devices to an exposed enclosure.
- Corrigendum1 pageEnglish languagee-Library read for1 day
This document gives guidance to the design of ventilative cooling systems while referring to relevant standards to ensure coherence and avoiding overlapping. In this document different design approaches for use of natural, mechanical or hybrid ventilative cooling can be found, starting at the feasibility phase before going into the design phase. In addition, this document gives guidance on where to find additional information on the design, calculation and maintenance of such systems.
This document is applicable to buildings specified according to the thermal indoor environmental aspects used for human occupancy where production processes don’t have a major impact on the indoor environmental quality. This document is applicable to residential and non-residential buildings.
This document applies to all types of buildings: new and retrofit, residential and non-residential.
This document is applicable to:
- mechanical ventilative cooling
- natural ventilative cooling
- hybrid ventilative cooling
- airing as a supplement to ventilative cooling specifically relevant during e.g. power failures
- supplementary free cooling as a supplement to ventilative cooling
The design of supplementary free cooling systems and active cooling systems are not part of the normative part of the document. However, the interface between ventilative cooling systems and supplementary free cooling systems as well as the interface between ventilative cooling and active cooling systems are mentioned informatively.
Design of ventilative cooling systems commonly considers other aspects like energy use, acoustic, draught, solar gain control, outdoor air quality, user acceptance, burglary and cleaning and maintenance, though these are not covered in detail in this document.
This document only covers temperature control.
This document does not apply to:
- moisture control
- waterborne
- heat losses.
- Technical specification112 pagesEnglish languagee-Library read for1 day
- Amendment13 pagesEnglish languagee-Library read for1 day
This document specifies restoration by electric arc welding and is limited to the head of the rails only.
This document describes the approval systems for consumables and procedures used in manual metal arc and flux cored metal deposit rail repair welding. This document includes the quality-related tasks and responsibilities of personnel involved in the electric arc repair welding of rails. This document applies to plain rail and switches and crossings manufactured from new Vignole railway rails R200, R220, R260, R260Mn, and R350HT grades rails of 27 kg/m and above as contained in EN 13674-1, EN 13674-2 and EN 13674-4.
The permitted welding processes are limited to Electric Arc (EA) in accordance with EN ISO 4063 and are by description Process No 111: SMAW (Shielded Metal Arc Welding) and Process No 114: FCAW (Flux Cored Arc Welding).
This document can be applied in situ, at line side or at out of track locations. The flash welded leg ends of austenitic manganese steel crossings are included in this document, except when located within 500 mm of manganese crossings. Where repairs are required within 500 mm, refer to EN 16725.
- Standard31 pagesEnglish languagee-Library read for1 day
This part of IEC 60679 describes the general properties, performance characteristics and usage precautions for quartz crystal oscillators. This document mainly describes crystal oscillators, but some descriptions also apply to oscillators other than crystal units (e.g. MEMS resonators).
- Standard50 pagesEnglish languagee-Library read for1 day
This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23 and B40, typically used for power, signal and data transmissions in industrial applications.
These connectors consist of fixed and free connectors either rewirable or non-rewirable.
NOTE B indicates that the connector is equipped with bayonet locking, while 12, 17, 23, 40 are the approximate dimensions in millimetres of the contact carrier diameter of these circular connectors.
Power contacts of male connectors are round contacts with Ø 1 mm, Ø 1,5 mm, Ø 1,8 mm, Ø 2,25 mm and Ø 4 mm, with current ratings up to 64 A per pole and rated voltage of 50 V, 300 V or 600 V AC/DC. Power contact groups are classified by type and identified throughout this document as “P” followed by two digits “01” through “09” (see 4.3, Table 1).
Signal contacts of male connectors are round contacts with Ø 1 mm and Ø 1,8 mm, with current ratings up to 20 A per pole and rated voltage of 50 V AC/DC. Signal contact groups are classified by type and identified throughout this document as “S” followed by “0”, “1”, or “2” (see 4.3, Table 2).
Male data contacts are round with Ø 0,8 mm and Ø 1 mm, with current ratings up to 4 A and rated voltage of 50 V AC/DC, Data modules are classified by type and identified throughout this document as “D” followed by “1”, or “2” (see 4.3, Table 3). D1 modules provide data transmission with frequencies from 1 MHz to 100 MHz; D2 modules provide data transmission with frequencies from 0,1 MHz to 600 MHz.
Besides the size of their bayonet locking (B12, B17, B23 or B40), connectors according to this document can be identified by data module (D) and complementing power (P) and signal (S) contact groups and optionally by number of poles, and finally by their application.
These connectors are designated for two main target applications, which differ as follows:
– Application A is for data transmission with power over data.
– Application B is for data transmission without power over data.
Connectors with power, signal and data contacts of the same gender are intended to also transmit power over the data contacts (application A), while connectors with data contacts not of the same gender of power and signal contacts are not intended to transmit power over the data contacts (application B).
The codings provided by this document prevent the mating to any other connector with similarly sized interfaces covered by this document.
- Standard109 pagesEnglish languagee-Library read for1 day
IEC/IEEE 62395-2:2024 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications. This document does not include or provide for any applications in potentially explosive atmospheres. This standard cancels and replaces IEC 62395-2:2013. This edition constitutes a technical revision. This standard includes the following significant technical changes with respect to IEC 62395-2:2013: a) Design considerations for trace heating on sprinkler systems have been expanded and a figure has been added to illustrate how to avoid undue shadowing of spray patterns from insulated sprigs close to sprinkler heads; b) Specific details of design considerations for trace heating for emergency eyewash units and safety showers have been added.
- Corrigendum1 pageEnglish languagee-Library read for1 day
- Corrigendum3 pagesEnglish languagee-Library read for1 day
- Corrigendum3 pagesEnglish and French languagee-Library read for1 day
This part of IEC 60730 applies to automatic electrical motor-starting relays
– intended to control the start windings of single phase motors;
– for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "control" means "motor-starting relays".
– intended for appliances within the scope of IEC 60335;
– for equipment that is used in building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
– for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment.
– used in, on, or in association with equipment that are smart enabled;
EXAMPLE 2 Smart grid control, remote interfaces/control of energy-consuming equipment.
– that are AC or DC powered with a rated voltage not exceeding 690 V AC or 600 V DC;
– used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
– utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
– using NTC or PTC thermistors, requirements for which are contained in Annex J;
– that are mechanically or electrically operated, responsive to or controlling such characteristics as current and voltage, or combinations thereof;
EXAMPLE 3 Centrifugal motor-starting devices.
– as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
– the inherent safety of motor-starting control, and
– functional safety of motor-starting control and safety related systems (when required),
– controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
– the operating values, operating times, and operating sequences where such are associated with equipment safety,
– motor-starting controls incorporating electronic devices, thermistor elements, thermal elements or magnetic elements.
This document specifies the requirements for construction, operation and testing of automatic electrical motor-starting relays used in, on, or in association with an equipment.
This document does not
– apply to motor-starting relays designed exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. However, this document can be applied to motor-start relays for equipment intended specifically for industrial applications in cases where no relevant safety standard exists;
– take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply;
– apply to general purpose relays or to contactors and motor starters of the type covered by IEC 60947 series;
– apply to mechanically operated motor-starting devices.
- Standard20 pagesEnglish languagee-Library read for1 day