Search Catalog

Standardization Organization
ICS
Technical Committee
Directive
Mandate

IEC 63296-3:2025 specifies the method for measuring the battery duration at a defined sound pressure level for continuous music playback of battery-operated wearable powered loudspeaker equipment. A primary battery or secondary battery can be used as a power source for such a shoulder-carried or body-worn loudspeaker and its composite device. In addition, only equipment that can be placed on or hung from a head and torso simulator (HATS) is covered. Bone conduction speakers are excluded. Portable loudspeaker equipment also supporting video playback as the main function is not covered by this document.

  • Standard
    17 pages
    English language
    e-Library read for
    1 day

This part of IEC 60794-1 describes test procedures used to establish uniform requirements for optical fibre cables for the environmental property - underwater cable resistance to hydrostatic pressure.
This document applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors.
See IEC 60794-1-2 for a reference guide to test methods of all types and for general requirements.

  • Standard
    17 pages
    English language
    e-Library read for
    1 day

IEC 62680-1-2:2026, the USB Power Delivery specification defines a power delivery system covering all elements of a USB system including USB Hosts, USB Devices, Hubs, Chargers and cable assemblies. This specification describes the architecture, protocols, power supply behavior, connectors and cabling necessary for managing power delivery over USB at up to 100W in SPR Mode and 240W in EPR Mode. This specification is intended to be fully compatible with and extend the existing USB infrastructure. It is intended that this specification will allow system OEMs, power supply and Peripheral developers adequate flexibility for product versatility and market differentiation without losing backwards compatibility.
IEC 62680-1-2:2026 cancels and replaces the seventh edition published in 2024 and constitutes a technical revision.
Extended Power Range (EPR) including Adjustable Voltage Supply (AVS) has been added. This document is the USB-IF publication Universal Serial Bus Power Delivery Specification Revision 3.2, Version 1.1.

  • Standard
    1052 pages
    English language
    e-Library read for
    1 day

This document establishes general rules and safety requirements on the application of capacitors, resistors, inductors, and complete filter units for electromagnetic interference
suppression which will be connected to an AC mains or other supply (DC or AC) with a nominal voltage not exceeding 1 000 V AC having a nominal frequency not exceeding 400 Hz, or 1 500 V DC.
It facilitates drafters of product safety standards and other stakeholders such as designers, manufacturers, se rvice providers, policy makers and regulators to consider safety aspects for the intended use and the reasonably foreseeable misuse of these components in its products and systems and apply risk reduction measures to achieve a tolerable risk level.

  • Standard
    31 pages
    English language
    e-Library read for
    1 day

This document provides two broad types of requirements for the determination and use of meteorological and oceanographic (metocean) conditions for the design, construction and operation of offshore structures:
those related to the determination of environmental conditions in general, together with the metocean parameters that are required to adequately describe them;
those related to the characterization and use of metocean parameters for the design, the construction activities or the operation of offshore structures.
This document covers the following environmental conditions and metocean parameters:
extreme and abnormal values of metocean parameters that recur with given return periods that are considerably longer than the design service life of the structure;
long-term distributions of metocean parameters in the form of cumulative, conditional, marginal or joint statistics of metocean parameters;
normal environmental conditions that are expected to occur frequently during the design service life of the structure.
Metocean parameters specified in this document are applicable to:
the determination of actions for the design of new structures;
the determination of actions for the assessment of existing structures;
the site-specific assessment of mobile offshore units;
the determination of limiting environmental conditions, weather windows, actions and action effects for pre-service and post-service situations (i.e. fabrication, transportation and installation or decommissioning and removal of a structure);
the operation of the platform, where appropriate.
It is beyond the scope of this document to provide detailed instructions that can be followed to produce reliable estimates of extreme or abnormal conditions in all areas and in all cases.

  • Standard
    340 pages
    English language
    e-Library read for
    1 day

This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element:
—   solid, hollow core and multilayer load-bearing wall elements;
—   retaining wall elements, excluding retaining walls intended to retain tanks or reservoirs of liquids and diaphragm walls (concrete sheet piling);
—   solid, hollow core and multilayer roof elements, excluding ribbed floor elements and floor slabs elements;
—   solid, hollow core and multilayer floor elements excluding floor elements with the intended use to carry traffic loads;
—   solid and hollow core beams;
—   solid piers.
This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended for not to be used as structural use:
—   solid, hollow core and multilayer non-loadbearing wall elements;
—   cladding elements;
—   rectangular cross-section box culverts;
—   components for noise barriers.
NOTE   In addition to their loadbearing and encasing function, elements can also be used to provide fire resistance, sound insulation and thermal insulation.
Recycled lightweight concrete with an open structure (other than closed-loop recycling during production) is covered by this document.

  • Standard
    78 pages
    English language
    e-Library read for
    1 day

This document applies to decorative, automatically controlled fireplaces for domestic use, producing a flame using liquid alcohol, hereafter referred to as fuel, for decoration.
NOTE 1   The requirements outlined in this document can be applied even outside domestic settings. In that case additional or different rules on the use of the fireplaces can apply.
This document applies to decorative fireplaces that do not require manual user interaction during normal operation. These fireplaces include electric or electronic components that control the basic operation (incl. automatic filling system).
NOTE 2   These components control the safe operation and avoid hazards such as:
—   Fuel spillage while filling
—   Overfilling
—   Fuel explosion while igniting
—   Accidental ignition while refilling
—   Overheating
—   Unsuccessful extinguishing
The document applies only to fireplaces for use in indoor areas.
This document applies to free-standing, wall-mounted and built-in fireplaces.
This document applies to fireplaces ready for use, whose burner is an integral component of the fireplace.
This document does not apply to fireplaces specifically designed for heating food or keeping food warm (rechauds), as well as to fireplaces for use in boats, caravans, other.
This document does not apply to fireplaces with declared heating function.
This document does not apply to fireplaces, that are connected to a flue.
NOTE 3   Because of the safety component of automatically operated fireplaces this scope is not limited to a specific heat output or fuel consumption. Regarding heat output limits, national legislation can apply.

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

This part of the EN IEC 61360 specifies the new data dictionary (domain) “IEC 61360-7 - General items” including its generic concepts. The IEC 61360-7 data dictionary provides concepts (dictionary elements e.g. classes, properties) intended for cross-domain use.

  • Standard
    14 pages
    English language
    e-Library read for
    1 day

IEC 81346-14:2026, published jointly by IEC and ISO, provides, in combination with IEC 81346‑1 and IEC 81346‑2, rules and recommendations on the structuring of systems and the information on systems of manufacturing systems. It also provides additional classification schemes to those of IEC 81346‑2 for use in reference designations within manufacturing systems. It is published as a double logo standard.
The structuring principles and the classes of objects are intended to provide a clear identification and localization of the objects, and for use in their labelling in the manufacturing plant, for their designation in technical documents and for the designation of the technical documents as well.
The requirements in this document apply for processing, transportation and storage of products, as well as for systems to support the manufacturing process such as electrical systems, management systems and waste disposal systems.
This document applies to different areas within the manufacturing industry such as light industry, electrical and optical industry, chemical industry, material industry and heavy industry.
This document is not applicable for designations related to product individuals (e.g. inventory number, serial number) nor to the products manufactured.
This document is also a horizontal publication intended for use by technical committees in preparation of publications related to reference designations in accordance with the principles laid down in IEC Guide 108.

  • Standard
    32 pages
    English language
    e-Library read for
    1 day

IEC 63479-3:2026 describes the infotainment services for public vehicles (PVIS) framework, including the functional reference models and the information flows for functional operations.

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

This document provides product category rules (PCR) guidance for the development of Type III environmental declarations for prefabricated reinforced components of autoclaved aerated concrete or lightweight aggregate concrete with open structure according to EN 15804:2012+A2:2019.
This document defines the parameters to be reported, the EPD types (and life cycle stages) to be covered, the rules to be followed for generating life cycle inventories (LCI) and conducting life cycle impact assessments (LCIA), and the data quality to be used in the development of EPDs.
In addition to the common parts of EN 15804:2012+A2:2019, this document provides guidance for elements made as prefabricated reinforced components of autoclaved aerated concrete or lightweight aggregate concrete with open structure:
—   defines the system boundaries;
—   defines the modelling and assessment of material-specific characteristics;
—   defines allocation procedures for multi-output processes along the production chain;
—   defines allocation procedures for reuse and recycling;
—   includes the rules for calculating the LCI and the LCIA underlying the EPD;
—   provides guidance/specific rules for the determination of the reference service life (RSL);
—   gives guidance on the establishment of default scenarios;
—   gives guidance on default functional units for elements.
This document is intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessments, when the intention is clearly stated in the system boundary description.

  • Standard
    41 pages
    English language
    e-Library read for
    1 day

This document specifies requirements for railway driving simulators for drivers' training. It defines the minimum functions and performances for a driver training simulator.
This document is applicable to all guided transport systems, including for mainlines, metros, tramways and light rails, as part of public/private transport systems. These vehicles are intended for the operation of intercity, urban and suburban passenger or freight services with self-propelled systems and operated on either segregated or not segregated paths.
Annexes A to D provide additional information.

  • Standard
    41 pages
    English language
    e-Library read for
    1 day

The purpose of this document is to define data communication services and protocols for computer equipment used for monitoring and control of HVAC&R and other building systems and to define, in addition, an abstract, object-oriented representation of information communicated between such equipment, thereby facilitating the application and use of digital control technology in buildings.

  • Standard
    1628 pages
    English language
    e-Library read for
    1 day

This document specifies methods of measurement of electrical power in networked standby mode and the reporting of the results for edge equipment.
The measurement of power and energy use in non-active mode, other than networked standby mode, is covered by IEC 62301 [1], including the input voltage range.
This document applies to edge equipment that is powered by:
– low voltage mains AC power (LV ≤ 1 000 V AC), or
– an external power supply that provides low voltage (LV ≤ 1 000 V) or extra low voltage (ELV ≤ 50 V) AC or DC power, or
– a separate source of extra low voltage DC power (ELV ≤ 50 V DC), or
– an internal main battery.
Conditions that are outside the scope of this document are as follows:
– active modes (primary function),
– other non-active modes (which are either covered by IEC 62301 [1] or by specific product group standards),
– conditions where main batteries are being charged other than in maintenance mode,
– disconnected condition of the equipment.
This document applies to the following product groups where a networked standby mode is present:
– edge equipment with a network reactivation function, such as household appliances, information technology equipment, audio, video and multimedia systems and equipment,
– digital radio receivers with an emergency warning function,
– gas burning equipment with electrical components.
NOTE 1 The measurements of power, energy use and performance of products during their intended use (when performing their primary functions) are generally specified in product standards and are not covered by this document.
NOTE 2 Networked standby mode for lighting equipment and the measurement of power is specified in IEC 63103 [4].
NOTE 3 Interconnecting equipment (equipment that provides network infrastructure and function) is outside the scope of this document. Measurement of electrical power in networked standby mode for interconnecting equipment is the subject of ETSI standard EN 303 423 [5].
This document also provides a method to test power management and to test whether it is possible to deactivate wireless network connection(s).
NOTE 4 Edge equipment can also include auxiliary batteries.
This group EE publication is primarily intended to be used as an EE standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products which are included in the boundary mentioned in the scope of this document.

  • Standard
    44 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances

  • Draft
    6 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of microwave appliances intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.

  • Draft
    6 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances

  • Draft
    28 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of electric vaporizers for household and similar use, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances

  • Draft
    5 pages
    English language
    e-Library read for
    1 day

This European standard deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances, including direct current (DC) supplied appliances and battery-operated appliances

  • Draft
    29 pages
    English language
    e-Library read for
    1 day

This document evaluates the use of the Bresle test (as defined in ISO 8502-9) for assessing soluble salt contamination on steel surfaces prepared with single-use abrasive blasting media. It presents comparative data from field and laboratory measurements using different analytical methods to determine whether conductivity values obtained from the Bresle test can be correlated to chloride and other salt concentrations.

  • Technical report
    9 pages
    English language
    sale 15% off

This European Standard deals with the safety of electric ondol-mattresses for household and similar purposes, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances. This standard also applies to control units supplied with the appliance

  • Draft
    6 pages
    English language
    e-Library read for
    1 day

This document specifies guidelines for grading raw sheep skins on the basis of their mass and size.

  • Standard
    2 pages
    English language
    sale 15% off

This European Standard deals with the safety of microwave appliances intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.

  • Draft
    49 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of electric vaporizers for household and similar use, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances

  • Draft
    21 pages
    English language
    e-Library read for
    1 day

This European Standard deals with the safety of electric ondol-mattresses for household and similar purposes, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances. This standard also applies to control units supplied with the appliance

  • Draft
    24 pages
    English language
    e-Library read for
    1 day

This document specifies a method for determining the ultimate aerobic biodegradability of plastic materials under controlled composting conditions by gravimetric measurement of the amount of carbon dioxide evolved. The method is designed to yield an optimum rate of biodegradation by adjusting the humidity, aeration and temperature of the composting vessel. The method applies to the following materials: natural and/or synthetic polymers and copolymers, and mixtures of these; plastic materials that contain additives such as plasticizers or colorants; water-soluble polymers; materials that, under the test conditions, do not inhibit the activity of microorganisms present in the inoculum. NOTE If the test material inhibits microorganisms in the inoculum, another type of mature compost or pre-exposure compost can be used.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

This document specifies the method for an application to: obtain OAuth tokens in a moderately secure manner for access to protected data; use OpenID Connect (OIDC) to identify the customer (user); and use tokens to access REST APIs in a moderately secure manner.

  • Standard
    13 pages
    English language
    sale 15% off

This European standard deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances, including direct current (DC) supplied appliances and battery-operated appliances

  • Draft
    6 pages
    English language
    e-Library read for
    1 day

This document specifies three procedures to check the performance of solar thermal collector fields. This document is applicable to most collector types addressed by ISO 9806. This includes glazed liquid heating flat plate collectors, evacuated tube collectors, and tracking, concentrating collectors. However, certain limitations apply in comparison to ISO 9806, specifically concerning wind and infrared sensitive collectors (WISC), hybrid collectors, and air collectors: WISC collectors are included only when both wind speed data measured on the collector plane and longwave radiation data are available. NOTE Such data is rarely available in practical applications. Hybrid collectors (“collectors co-generating thermal and electrical power” in ISO 9806, commonly PVT) are excluded. The reason is that their thermal performance in real-world operation depends on the operation of the electrical part: If the electrical part is switched off, limited, or curtailed for any reason, while the thermal part remains active, this would lead to an overestimation of the thermal power output, based on performance parameters determined under MPP conditions (maximum electrical power generation), as specified in ISO 9806. Solar air heating collectors (SAHC) are excluded due to the complexity of accurately assessing their performance: Testing and evaluating SAHC performance is complex, because it requires accounting for the enthalpy difference in the primary loop. Additionally, their thermal efficiency is highly dependent on mass flow rate, and their performance is tested at three different air mass flow rates, resulting in three separate parameter sets. For the ISO 24194 Power Check, this makes it challenging to select the appropriate parameters for estimating thermal power output. This document specifies procedures for performance check of the thermal power output of the collector field as well as on the daily yield and annual yield of the collector field. For the three procedures, this document specifies how to compare a measured output with the calculated one. The document is applicable to collector fields of all sizes.

  • Standard
    50 pages
    English language
    sale 15% off
  • Draft
    54 pages
    French language
    sale 15% off

This document specifies the brain–computer interface (BCI) reference architecture (RA). The BCI RA defines the key characteristics of BCI systems, provides a common language for stakeholders, and addresses their concerns. It also provides guidance to system architects on efficient BCI system design, typical implementation categories and effects of using BCI technology in developing applications. Additionally, this document serves as a technical reference for architects, manufacturers, vendors, service providers, regulators and the public to better understand the BCI architecture, its functions and the underlying technology that supports the BCI systems.

  • Standard
    18 pages
    English language
    sale 15% off

This document provides guidance for communicating the risks related to the beneficial use of biosolids produced from industrial and municipal sludge and municipal biosolids derived products (e.g. composts, growing medium) and for managing public perception related to their use. This document: defines key concepts related to risk and risk communication; provides context for risk in relation to the beneficial use of biosolids; describes public perceptions and responses to the beneficial use of biosolids at a global scale; outlines risk communication principles, methods, and tools; includes case studies and examples of communication strategies. This document can also be used to support the development of biosolids management plans, particularly in relation to community consultation, engagement, and communication activities. In addition, it can be applied, where appropriate, to risk communication associated with other beneficial uses of biosolids or similar materials. This document does not apply to communication regarding hazardous sludge originating from wastewater that, due to its physical, chemical, or infectious properties, can pose significant risks to human health or the environment during use, handling, storage, or transportation, and requires specialized disposal methods. The definition of “beneficial use of biosolids” is outside the scope of this document.

  • Standard
    25 pages
    English language
    sale 15% off

This document defines an evaluation procedure and evaluation methods for assessing the accuracy and precision of 3D modelling software for designing 3D printing models using phantoms. This document is not intended to evaluate the 3D-printed product itself.

  • Standard
    24 pages
    English language
    sale 15% off

This document provides requirements and recommendations for the ecotoxicological evaluation and classification of sludge for land application, and suitable land application pathways. This document applies to sludge from wastewater treatment plants.

  • Standard
    29 pages
    English language
    sale 15% off

This document is intended for the validation of codes used for the calculation of doses received by individuals on board aircraft. It gives guidance to radiation protection authorities and code developers on the basic functional requirements which the code fulfils. Depending on any formal approval by a radiation protection authority, additional requirements concerning the software testing can apply.

  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

The scope of this document is the definition of the functional interface between the TDC and other train systems. These "Other Train Systems" are the train systems interfacing with the TDC excluding the displays (CLC/TR 50542-2), ETCS/STM onboard (Subset-121) and already designed class B ATP systems.
The functional interface deals with data exchanged between the TDC and these train systems as shown in Figure 1.
The TDC is defined in document CLC/TR 50542-1.
(...)

  • Technical report
    11 pages
    English language
    e-Library read for
    1 day

This document specifies requirements and recommendations for remote maintenance services (RMSs) of medical devices and medical information systems in healthcare facilities (HCFs). This document is applicable to HCFs and remote service centres (RSCs) providing remote maintenance services for medical devices and medical information systems. This document specifies the risk assessment necessary to protect remote maintenance activities, taking into consideration the special characteristics of the healthcare field such as patient safety, regulations and privacy protections. This document provides practical examples of risk analysis to protect both the HCF and RMS provider information assets in a safe and efficient (i.e. economical) manner. These assets are primarily the information system itself and personal health data held in the information system.

  • Technical specification
    19 pages
    English language
    sale 15% off

This document summarizes measurement results for the use of RFID on plastic returnable transport items (RTIs). This document describes the followings: materials of plastic RTIs, features, reliability of RFID used for plastic RTIs, and measurement results for the use of RFID on plastic RTIs.

  • Technical report
    48 pages
    English language
    sale 15% off

This document applies to the testing of surfaces that may become contaminated by radioactive materials.
The ease of decontamination is a property of a surface and an important criterion for selecting surface
materials used in the nuclear industry, interim storage or disposal facilities from which contamination can
be removed easily and rapidly without damaging the surface. The test described in this document is a rapid
laboratory-based method to compare the ease of decontamination of different surface materials.
The results from the test can be one parameter to take into account when selecting surface coatings such
as varnish or impervious layers such as ceramics and other surfaces. The radionuclides used in this test
are those commonly found in the nuclear industry (137Cs, 134Cs and 60Co) in aqueous form. The test can also be adopted for use with other radionuclides and other chemical forms, depending on the customer requirements, if the solutions are chemically stable and do not corrode the test specimen.
The test does not measure the ease of decontamination of the surface materials in practical use, as this
depends on the radionuclide(s) present, their chemical form, the duration of exposure to the contaminant
and the environmental conditions amongst other factors.
The test method is not intended to describe general decontamination procedures or to assess the efficiency of decontamination procedures (see ISO 7503-1 to ISO 7503-3).
The test method is not suitable for use of radiochemicals if the radionuclide emits low energy gamma rays or beta particles that are readily attenuated in the surface.

  • Standard
    42 pages
    English language
    e-Library read for
    1 day

IEC 61753-022-02: 2026 defines the minimum initial test and measurement requirements and severities which multimode fibre optic connectors terminated as a pigtail or patchcord satisfy in order to be categorized as meeting the IEC standard category C (controlled environment), as defined in IEC 61753‑1. This first edition cancels and replaces the second edition of IEC 61753-022-2 published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of provisions for rectangular ferrule connectors;
b) additions of terms and definitions;
c) update of the fibre naming conventions in accordance with IEC 60793-2-10;
d) update of test severities in accordance with IEC 61753‑1;
e) addition of the torsion test;
f) reduction of the duration of the fibre/cable retention test on reinforced cables from 120 s to 60 s minimum;
g) deletion of the static side load test;
h) update of the flexing of the strain relief test to use the change in attenuation instead of the transient loss;
i) reduction of the number of mating durability cycles for cylindrical ferrule connectors from 500 cycles to 200 cycles;
j) addition of the mating durability for rectangular ferrule connectors with 50 cycles;
k) addition of Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.

  • Standard
    23 pages
    English language
    e-Library read for
    1 day

This document gives the botanical names of the main species of oleaginous plants, together with the names of the corresponding raw materials and oils (fats). This document is applicable to both edible oil and non-edible oils. An alphabetical index of the raw materials is also given to assist in the use of this document.

  • Standard
    17 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off

This document specifies an analytical method for determining the neptunium concentration by spectrophotometry, with spectrophotometer implemented in hot cell or glove box allowing the analysis of high activity solutions, with a standard uncertainty, with coverage factor k = 1 of about 5 %, in nitric acid solutions after the dissolution of nuclear reactor irradiated fuels, at different steps of the process in a nuclear fuel reprocessing plant or in other nuclear facilities. The method is applicable to sample from the process containing a concentration of neptunium between 10 mg·l-1 and 400 mg·l-1 and uranium concentrations of up to 300 g·l-1.

  • Standard
    16 pages
    English language
    e-Library read for
    1 day

This document describes an analytical method for the determination of uranium in samples from pure product materials such as U metal, UO2, UO3, U3O8, uranyl nitrate hexahydrate and uranium hexafluoride from the nuclear fuel cycle. This procedure is sufficiently accurate and precise to be used for nuclear materials accountability. This method can be used directly for the analysis of most uranium and uranium oxide nuclear reactor fuels, either irradiated or un-irradiated, and of uranium nitrate product solutions. Fission products equivalent to up to 10 % burn-up of heavy atoms do not interfere, and other elements which could cause interference are not normally present in sufficient quantity to affect the result significantly. The method recommends that an aliquot of sample is weighed and that a mass titration is used, in order to obtain improved precision and accuracy. This does not preclude the use of alternative techniques which could give equivalent performance. The use of automatic device(s) in the performance of some critical steps of the method has some advantages, mainly in the case of routine analysis.

  • Standard
    25 pages
    English language
    e-Library read for
    1 day

IEC/IEEE 62209-1528:2020 specifies protocols and test procedures for the reproducible and repeatable measurement of the conservative exposure peak spatial average SAR (psSAR) induced inside a simplified model of the head and the body by radio-frequency (RF) transmitting devices, with a defined measurement uncertainty. These protocols and procedures apply to a significant majority of the population, including children, during the use of hand-held and body-worn wireless communication devices. These devices include single or multiple transmitters or antennas, and are operated with their radiating structure(s) at distances up to 200 mm from a human head or body. This document is employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, operating in conjunction with other RF-transmitting, non-transmitting devices or accessories (e.g. belt-clips), or embedded in garments. The applicable frequency range is from 4 MHz to 10 GHz. Devices operating in the applicable frequency range can be tested using the phantoms and other requirements defined in this document.
The device categories covered include, but are not limited to, mobile telephones, cordless microphones, and radio transmitters in personal, desktop and laptop computers, for multi band operations using single or multiple antennas, including push-to-talk devices. This document can also be applied for wireless power transfer devices operating above 4 MHz.
This document does not apply to implanted medical devices.
This first edition of IEC/IEEE 62209-1528 cancels and replaces IEC 62209-1:2016, IEC 62209-2:2010, IEC 62209 2:2010/AMD1:2019 and IEEE Std 1528:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) extension of the frequency range down to 4 MHz and up to 10 GHz;
b) testing of devices with proximity sensors;
c) application specific phantoms;
d) device holder specifications;
e) fast SAR testing procedures;
f) test reduction procedures;
g) LTE assessment procedure;
h) revision of validation clause, including validation antennas;
i) revision of SAR assessment procedure;
j) time-average SAR measurement procedure;
k) uncertainty analysis;
This publication is published as an IEC/IEEE Dual Logo standard.

  • Standard
    280 pages
    English language
    sale 15% off
  • Standard
    589 pages
    English language
    sale 15% off
  • Standard
    600 pages
    English and French language
    sale 15% off

This document defines the contents, methods and requirements of configuration management for space projects, and the responsibilities and authorities of related parties. It is intended to be used in conjunction with ISO 14300-1:2023, Clause 10. This document is applicable to the configuration management of space projects from the mission analysis phase to the disposal phase.

  • Standard
    28 pages
    English language
    sale 15% off

ISO/IEC 27572:2026 specifies the brain–computer interface (BCI) reference architecture (RA). The BCI RA defines the key characteristics of BCI systems, provides a common language for stakeholders, and addresses their concerns. It also provides guidance to system architects on efficient BCI system design, typical implementation categories and effects of using BCI technology in developing applications. Additionally, this document serves as a technical reference for architects, manufacturers, vendors, service providers, regulators and the public to better understand the BCI architecture, its functions and the underlying technology that supports the BCI systems.

  • Standard
    18 pages
    English language
    sale 15% off

This document summarizes measurement results for the use of RFID on metal returnable transport items (RTIs). This document describes the following: types of metal RTIs, features, reliability of RFID used for metal RTIs, and measurement results for the use of RFID on metal RTIs.

  • Technical report
    57 pages
    English language
    sale 15% off

The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed. The severities specified are those which will have a low probability of being exceeded; generally less than 1 % of the operating time in a year. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at weatherprotected locations defined in clause 5.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    19 pages
    English language
    sale 15% off
  • Standard
    19 pages
    English language
    e-Library read for
    1 day

This document is applicable to test methods designed to be used at the place of installation of the articulated extraction arms (AEA), usually a laboratory and for various laboratory applications that require local extraction. They are used for commissioning after installation, for maintenance and for qualification purposes. For certain customer requirements additional or modified test methods can be necessary.
This document includes product functional performance referring to product standard detailed in EN 16589-1. Occupational health and safety assessments methods are not included in this document.
This document does not consider performance requirements for the extract air system associated with the AEA installation and therefore extract system performance is not part of the scope.
This document does not confirm or establish a capture zone of an AEA capture device only the functional extract capacity and mechanical functions of the AEA.

  • Standard
    21 pages
    English language
    e-Library read for
    1 day