This document analyses a feasible way to accommodate interoperability elements for the data component of a spatial data infrastructure (SDI) and extend the meta model framework for interoperability (MFI) in securing interoperability among heterogeneous domain information models under the smart city context. This document: a) outlines the interoperability issues for city domain information models; b) reviews relevant standards and best practices and examines methodologies or solutions to tackle the interoperability issues; c) supposes a use case and provides an example to secure interoperability among different domain information models using model registry; d) specifies technical requirements in concern about how to apply the interoperability elements of the meta model framework to support the interoperability of smart city services; e) highlights the standardization items to be developed to secure interoperability.
- Technical report18 pagesEnglish languagesale 15% off
This document specifies requirements for producing and testing an undyed sulfuric acid anodic coating on aluminium alloys. The anodizing process is applied in the manufacture of aerospace products to improve paint adhesion and resistance to corrosion.
- Standard8 pagesEnglish languagesale 15% off
This document specifies information metadata, metrics metadata, clinical data linkage metadata, auxiliary fields, SAM interoperability, protection metadata and programming interfaces of genomic information. It defines: — metadata storage and interpretation for the different encapsulation levels as specified in ISO/IEC 23092-1 (in REF Section_sec_6 \r \h Clause 6 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E000000530065006300740069006F006E005F007300650063005F0036000000 ); — metrics metadata containing sequencing data metrics at the dataset and access unit levels as specified in ISO/IEC 23092-1 (in REF Section_sec_7 \r \h Clause 7 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E000000530065006300740069006F006E005F007300650063005F0037000000 ); — clinical data linkage metadata stored at the dataset group, dataset and annotation table levels as specified in ISO/IEC 23092-1 (in REF Section_sec_8 \r \h Clause 8 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E000000530065006300740069006F006E005F007300650063005F0038000000 ); — protection elements providing confidentiality, integrity and privacy rules at the different encapsulation levels as specified in ISO/IEC 23092-1 (in REF Section_sec_9 \r \h Clause 9 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E000000530065006300740069006F006E005F007300650063005F0039000000 ); — how to associate auxiliary fields to encoded reads (in REF Section_sec_10 \r \h Clause 10 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000F000000530065006300740069006F006E005F007300650063005F00310030000000 ); — interfaces to access genomic information coded in compliance with ISO/IEC 23092-1 and ISO/IEC 23092-2 (in REF Section_sec_12 \r \h Clause 12 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000F000000530065006300740069006F006E005F007300650063005F00310032000000 ); — mechanisms for backward compatibility with existing SAM content, and exportation to this format (in Annex E).
- Standard120 pagesEnglish languagesale 15% off
NOTE Clause A.2 contains guidance or rationale for this clause. This document specifies requirements for small-bore connectors intended to be used for connections in neural applications. This document does not specify requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular standards for specific medical devices or accessories.
- Standard31 pagesEnglish languagesale 15% off
- Standard32 pagesFrench languagesale 15% off
This document specifies the requirements for technical procedures, quality inspection, etc. for the surface treatment of austenitic stainless steel parts (e.g. 300 series, AISI 651, A286 or equivalent). This document applies to the removal of organic and inorganic contaminants, surface cleaning, surface finishing and surface passivation before the non-destructive test of austenitic stainless steel parts.
- Standard11 pagesEnglish languagesale 15% off
1.1 General
This document is applicable to food depositors as listed in 1.2 and the equipment typically integrated with them, i.e. product pumps, product elevators, conveyors and indexing mechanisms, when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer (see Annex B).
This document deals with the significant hazards, hazardous situations and events during transport, assembly and installation, commissioning, use, decommissioning, disabling, dismantling and scrapping.
NOTE 1 According to the clause which is referred to, "use" includes "setting, teaching/programming or process changeover, operation, cleaning, fault finding and maintenance".
NOTE 2 Although this document is intended to apply to depositors used in the food industry, many of its requirements can also be used for the same or similar machines used in other industries.
This document does not apply to the following machines:
- auger depositors or auger fillers and gravimetric filling machines; safety requirements for these machines are contained in EN 415-3;
- automatic dough dividers, safety requirements for these machines are contained in EN 12042;
- filling machines for sausages, safety requirements for these machines are contained in EN 12463;
- mincing machines, safety requirements for these machines are contained in EN 12331;
- food depositors that are powered exclusively by manual effort;
- roller depositors intended for use in craft bakeries. Safety requirements for these machines are in EN 17677.
This document does not deal with the following hazards:
- hazards related to the use of food depositors in a potentially explosive atmosphere;
- hazards that can arise from using a food depositor to deposit a non-food product.
This document is not applicable to food depositors that were manufactured before the date of its publication as a European Standard.
1.2 Types of food depositors
1.2.1 General
This document deals with five different types of food depositor. The component parts of each of the different types of depositor are labelled in the figures shown in Clause 4 of this document.
1.2.2 Piston depositor
A piston depositor typically comprises a hopper, a rotary valve, a product measuring chamber in the form of a piston and a product dispensing valve. Some piston depositors incorporate several product measuring chambers and dispensing valves. Some designs dispense the product directly from the rotary valve without the use of a separate product dispensing valve. The volume of product dispensed is varied by altering the stroke of the product measuring chamber piston. Piston depositors are used to fill liquids, liquids containing solids in suspension and pastes. The product dispensing valve can be attached rigidly to the depositor or using a flexible pipe and in some cases is held by the operator. Figure 1 shows the typical cross section of a piston depositor.
Figure 1 - Piston depositor
1.2.3 Chamber depositor
A chamber depositor comprises a hopper feeding one or more product measuring chambers that are filled under gravity from the top. When the chamber has been filled with product the flow of product is stopped either by moving the chamber or using a product cutting device. The product is then discharged through the bottom of the chamber either by moving the chamber or by moving a plate in the base of the chamber. The volume of product dispensed is varied by altering the volume of the chamber. Chamber depositors are typically used to deposit free-flowing products like cooked rice or pasta. Figure 2 shows the typical cross section of a chamber depositor.
Figure 2 - Chamber depositor
1.2.4 Roller depositor
A roller depositor typically comprises a hopper that feeds product to two or more fluted contra-rotating rollers. These rollers force the product through one or more dies that shape the product.
...
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides a telehealth cybersecurity reference model of the overall security framework for systems and services applied to telehealth. This document contains a general description of: — factors of telehealth cybersecurity threats; — relationships between security risks and safety risks in telehealth services; — methodologies for defining security levels in telehealth services; — a cybersecurity reference model of telehealth services. Defining the specific type of telehealth services is not covered in this document.
- Technical specification12 pagesEnglish languagesale 15% off
This document specifies requirements for producing and testing a dyed sulfuric acid anodic coating on aluminium alloys. The anodizing process is applied in the manufacture of aerospace products to improve paint adhesion and resistance to corrosion and can colour the part in accordance with the drawing requirements.
- Standard8 pagesEnglish languagesale 15% off
This document specifies a test method for the quantitative determination of the antifungal activity by measuring the intensity of luminescence produced by an enzymatic reaction [adenosine triphosphate (ATP) method]. This document is applicable to various kinds of textile products, such as fibres, yarns, fabrics, clothing, bedclothes, home furnishings and other miscellaneous goods.
- Standard19 pagesEnglish languagesale 15% off
- Standard20 pagesFrench languagesale 15% off
This document specifies a method for the determination of the specific electrical resistivity of cathode blocks and baked anodes used in the production of aluminium, using samples at ambient temperature.
- Standard4 pagesEnglish languagesale 15% off
This document specifies the requirements for technical procedures, quality inspection, etc. for the surface treatment of martensitic, precipitation hardening and maraging stainless steel parts (e.g.400 series, 17-7PH, 17-4PH, 15-5PH, AM350, AM355, PH15-7Mo, PH13-8Mo, Custom 450 and 455 or equivalent). It provides practical methods for removing contaminants and for obtaining suitable corrosion resistance for aerospace applications. This document applies to the removal of organic and inorganic contaminants, surface cleaning, surface finishing and surface passivation before non-destructive inspection of martensitic, precipitation hardening and maraging stainless steel parts.
- Standard11 pagesEnglish languagesale 15% off
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the most important design and metrological characteristics of two-point inside micrometers:
— with a scale interval or digital step of 0,001 mm and 0,01 mm;
— with analogue or digital indication.
This document is applicable to two-point inside micrometers with and without interchangeable extensions.
This document does not apply to micrometers fitted with a dial gauge, or to jaw micrometers.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as:
a) bed frames;
b) bedside tables;
c) transport carts;
d) containers;
e) surgical tables;
f) sterilization containers;
g) surgical clogs;
h) wheelchairs;
i) aids for persons with disabilities.
This document also specifies the performance requirements for the cleaning and disinfection of the WD and its components and accessories.
Devices identified within the scopes of ISO 15883-2, ISO 15883-3, ISO 15883-4, and ISO 15883-6 do not fall within the scope of this document.
In addition, this document specifies the methods for type testing, works testing, validation (installation, operation, and performance qualification on first installation), routine control, and monitoring, as well as requalifications to be carried out periodically and after essential repairs.
NOTE 1 WD covered by this document can also be used for cleaning and chemical disinfection of other thermolabile and reusable devices as recommended in the instructions for use (IFU) for those devices.
NOTE 2 The performance requirements specified in this document cannot ensure the inactivation or removal of the causative agent(s) (prion proteins) of transmissible spongiform encephalopathies.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies two accelerated corrosion test methods. These methods assess the corrosion resistance of products containing copper in environments where there is a significant influence of chloride ions, mainly as sodium chloride from a marine source or winter road de-icing salt, as well as the influence of corrosion-promoting gases from industrial or traffic air pollution.
This document specifies both the test apparatus and test procedures to be used in executing the accelerated corrosion tests.
The methods are especially suitable for assessing the corrosion resistance of sensitive products with metals, e.g. electronic components, used in traffic and industrial environments.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62282-3-202:2025 provides performance test methods specialized for the thermal and electrical characteristics of an energy management system to effectively share the heat and power of networked small stationary fuel cell power systems. These test methods are applied for each small stationary fuel cell power system. This document covers small stationary fuel cell power systems which can be complemented with a supplementary heat generator or a thermal storage system, or both, such as:
- output: rated electric power output of less than 10 kW for each system;
- output mode: grid-connected or independent operation or stand-alone operation with alternating current (AC) output not exceeding 240 V or direct current (DC) output;
- operating pressure: maximum allowable working pressure of less than 0,1 MPa (G) for the fuel and oxidant passages;
- fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen) or liquid fuel (kerosene, methanol); oxidant: air.
This document does not apply to small stationary fuel cell power systems with electricity storage other than (small scale) back-up power for safety, monitoring and control.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies three methods for the determination of the ash of poly(vinyl chloride).
The general procedures given in ISO 3451-1 are followed. For ash, method A is used. For sulfated ash, methods B and C are used. All three methods are applicable to resins, compounds and finished products. Methods B and C are applicable when lead-containing compounds are present.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements relating to:
Aluminium alloy AL-P2014A
T6 or T62
Clad sheets and strips
0,4 mm ≤ a ≤ 6 mm
for aerospace applications.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the test methods to evaluate the performance of coaxial, quadrax and databus cables after the installation of plastic cable ties.
It is expected to be used together with EN 3475 100.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method of determining the ability of elements of connection to withstand sinusoidal or random vibrations of specified severities.
It is used together with EN 2591-100.
This test is based on EN 60068-2-6 and EN 60068-2-64.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
DEN/ERM-TG28-561
- Standard100 pagesEnglish languagesale 15% off
- Standard100 pagesEnglish languagesale 15% off
- Standard100 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric sewing machines for household and similar use, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances.
- Draft20 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric insect killers for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electric sewing machines for household and similar use, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of stand-alone electric spin extractors, and pin extractors incorporated in washing machines that have separate containers for washing and spin extraction for household and similar purposes that have a capacity not exceeding 10 kg of dry cloth and a drum peripheral speed not exceeding 50 m/s, their rated voltages being not more than 250 V for single-phase appliances and 480 V for other appliances
- Draft25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62290‑1:2025 provides an introduction to the IEC 62290 series and deals with the main concepts, the system definition, the principles and the basic functions of UGTMS (urban guided transport management and command/control systems) for use in urban guided passenger transport lines and networks. This document is applicable for new lines or resignalling of existing lines. This document is applicable to applications using: - continuous data transmission, - continuous supervision of train movements by train protection profile, and - localisation of trains by onboard UGTMS equipment (reporting trains), and optionally by external wayside (and optionally onboard) device. The IEC 62290 series specifies the functional, system and interface requirements for the command, control, and management systems intended to be used on urban, guided passenger transport lines and networks. These systems are designated herein as urban guided transport management and command/control systems (UGTMS). UGTMS cover a wide range of operations needs from non-automated (GOA1) to unattended (GOA4) operation. A line may be equipped with UGTMS on its full length or only partly equipped. The IEC 62290 series does not specifically address security issues. However, aspects of safety requirements may apply to ensuring security within the urban guided transit system. The main objectives of this series are as follows: - to provide a baseline system description and functional requirements specification for a transport authority to use in a request for proposal, - to provide recommendations for those transport authorities wishing to acquire an interoperable or interchangeable system. It is the responsibility of the transport authority concerned to decide on how to apply the IEC 62290 series and to take into account their particular needs. This document is applicable to applications using: - continuous data transmission, - continuous supervision of train movements by train protection profile, and - localisation of trains by onboard UGTMS equipment (reporting trains), and optionally by external wayside (and optionally onboard) device. This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Figure 3, giving the system environment of UGTMS, has been amended to reflect the adaptation of it; b) external equipment for which no requirement is described in the IEC 62290 series has been removed; c) new external equipment having such requirements (like the washing machine) has been added.
- Draft31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of - portable heated carpets; - heated carpets and similar appliances; - heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.
- Draft5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62290‑3:2025 specifies the system architecture for urban guided transport management and command/control systems (UGTMS) as defined in IEC 62290‑1 and IEC 62290‑2, and the allocation of functions and requirements defined in IEC 62290‑2 to the different UGTMS subsystems (designated as system constituents in IEC 62290‑1 and IEC 62290‑2), for use in urban guided passenger transport lines and networks. The IEC 62290 series specifies the functional, system and interface requirements for the command, control, and management systems intended to be used on urban, guided passenger transport lines and networks. These systems are designated herein as urban guided transport management and command/control systems (UGTMS). UGTMS cover a wide range of operations needs from non-automated (GOA1) to unattended (GOA4) operation. A line may be equipped with UGTMS on its full length or only partly equipped. The IEC 62290 series does not specifically address security issues. However, aspects of safety requirements may apply to ensuring security within the urban guided transit system. The main objectives of this series are as follows: * to provide a baseline system description and functional requirements specification for a transport authority to use in a request for proposal, * to provide recommendations for those transport authorities wishing to acquire an interoperable or interchangeable system. It is the responsibility of the transport authority concerned to decide on how to apply the IEC 62290 series and to take into account their particular needs. The IEC 62290 series is also intended to support applications for upgrading existing signalling and command control systems. In this case, interchangeability and compatibility could be ensured only for the additional UGTMS equipment. Checking the possibility for upgrading existing equipment and the level of interoperability is the responsibility of the transport authority concerned. This document is applicable for new lines or for upgrading existing signalling and command control systems. This document is applicable to applications using * continuous data transmission, * continuous supervision of train movements by train protection profile, and * localisation by onboard UGTMS equipment (reporting trains), and optionally by external wayside (and optionally onboard) device. The functional allocations of the UGTMS subsystems are mandatory (forming a sort of core system) or optional, according to the mandatory/optional functions and requirements defined in IEC 62290‑2. This document is applicable as a basis to define FIS and FFFIS. For specific applications, some elements can be added to meet the requirements coming from additional functions or equipment. This second edition cancels and replaces the first edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the last maintenance of IEC 62290‑1 is taken into account, in particular the changes made for describing the external environment of UGTMS; b) the last maintenance of IEC 62290‑2 is taken into account, as IEC 62290‑3 is using the requirements defined in the latter. Therefore, the document reflects the deleted functions and requirements in IEC 62290‑2, and also the new functions and requirements.
- Draft280 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of electrical recovery and/or recycle equipment to recover and/or recycle refrigerant from air conditioning and refrigeration equipment.
- Draft49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of stand-alone electric spin extractors, and pin extractors incorporated in washing machines that have separate containers for washing and spin extraction for household and similar purposes that have a capacity not exceeding 10 kg of dry cloth and a drum peripheral speed not exceeding 50 m/s, their rated voltages being not more than 250 V for single-phase appliances and 480 V for other appliances
- Draft7 pagesEnglish languagesale 10% offe-Library read for1 day
The present document specifies technical requirements, limits and test methods for Short Range Devices in the non-
specific category operating in the frequency range 25 MHz to 1 000 MHz.
The non specific SRD category is defined by the EU Commission Decision 2019/1345/EU [i.3] as:
"The non-specific short-range device category covers all kinds of radio devices, regardless of the application or the
purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry,
telecommand, alarms, data transmissions in general and other applications".
These radio equipment types are capable of transmitting up to 500 mW effective radiated power and operating indoor or
outdoor.
NOTE: The relationship between the present document and the essential requirements of article 3.2 of
Directive 2014/53/EU [i.2] is given in Annex A
- Standard107 pagesEnglish languagesale 15% off
- Standard107 pagesEnglish languagesale 15% off
- Standard107 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard deals with the safety of - portable heated carpets; - heated carpets and similar appliances; - heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.
- Draft46 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for temporary edge protection systems for use during construction or maintenance of buildings and other structures.
This document applies to edge protection systems for flat and inclined surfaces and specifies the requirements for three classes of temporary edge protection.
For edge protection systems with an arrest function (e.g. falling or sliding down a sloping roof) this document specifies requirements for energy absorption.
This document includes edge protection systems, some of which are fixed to the structure and others, which rely on gravity and friction on flat surfaces.
This document does not provide requirements for edge protection systems intended for:
— protection against impact from vehicles or from other mobile equipment,
— protection from sliding down of bulk loose materials, snow etc,
— protection of areas accessible to the public.
This document does not apply to side protection on scaffolds according to EN 12811 1 and EN 1004 1.
NOTE This does not prevent these systems to be used on temporary structures.
- Draft44 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for the physical properties of powered toothbrushes in order to promote the safety of these products for their intended use.
There are different technologies of powered toothbrushes. Common features of those powered toothbrushes to which this document applies are:
— a battery;
— a motor;
— a mechanical or magnetic drive system;
— a moving brush head with tufted filaments.
Powered toothbrushes can have a moving brush head with different motions (e.g. oscillating-rotating, side-by-side), frequencies and velocities.
These types of electric toothbrushes are tested for safety in use by means of appropriate test procedures or clinical studies
The requirements listed in this document apply to all types of powered toothbrushes. However, there is a possibility that some requirements are not applicable for all types. For example, brush head plate retention can only be applied if the brush has a head portion that can detach from the brush shaft. In addition, for the filaments end-rounding requirements, this document does not apply to filament types that are very thin (less than 0,1 mm outside diameter) or have no sharp edges (e.g. tapered, feathered, with split tips or spherical cap) or non-synthetic filaments, where applying the end-rounding process is inappropriate or impossible.
This document is not applicable to other types of powered oral hygiene devices (such as powered interdental brushes) or manual toothbrushes.
- Draft24 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use-products - with water.
This document applies to products that are used in the veterinary area for disinfecting non-porous surfaces without mechanical action - i.e. in the breeding, husbandry, production, veterinary care facilities, transport and disposal of all animals except when in the food chain following death and entry to the processing industry.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances in the conditions in which they are used.
NOTE 2 This method corresponds to a Phase 2 Step 2 test.
This method excludes the evaluation of the activity of products against yeasts, fungal spores, mycobacteria and bacterial spores.
- Draft37 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines fundamental terminology for blockchain and distributed ledger technologies.
- Draft19 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for the design, manufacture and testing of cylinders, tubes and other pressure vessels of steel, stainless steel, aluminium alloys or of non-metallic construction material. These are intended for the stationary storage of gaseous hydrogen of up to a maximum water capacity of 10 000 l and a maximum allowable working pressure not exceeding 1 100 bar, of seamless metallic construction (Type 1) or of composite construction (Types 2, 3 and 4), hereafter referred to as pressure vessels.
NOTE Additional requirements with regard to assemblies (manifolded cylinders and tubes and other pressure vessels) are not covered by this document.
This document is not applicable to Type 2 and 3 vessels with welded liners.
This document is not applicable to pressure vessels used for solid, liquid hydrogen or hybrid cryogenic-high pressure hydrogen storage applications.
This document is not applicable to external piping which can be designed according to recognized standards.
- Draft68 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for the determination of the oxidation stability of fuels for diesel engines at 110 °C, by means of measuring the induction period of the fuel up to 48 h. The method is applicable to fatty acid methyl esters (FAME) intended for the use as pure biofuel or as a blending component for diesel fuels, and to blends of FAME with diesel fuel containing 2 % (V/V) of FAME at minimum.
The precision of the test method has been developed for conventional diesel. This test method is applicable for paraffinic diesel fuels as specified in EN 15940, however, a separate precision statement for paraffinic diesel is not available.
NOTE 1 EN 14112 [1] describes a similar test method for the determination of the oxidation stability of pure fatty acid methyl esters (see the Introduction to this document). Additionally, EN 16568 [4] describes a similar test method for the determination of the oxidation stability of fuels for diesel engines at 120 °C, by means of measuring the induction period of the fuel up to 20 h. EN 16568 is applicable to blends of FAME with diesel fuel containing 2 % (V/V) of FAME at minimum. Other alternative test methods for the determination of the oxidation stability of distillate fuels are described in CEN/TR 17225 [5].
NOTE 2 For induction periods higher than 48 h the precision is not covered by the precision statement of this method. The limit values of the relevant fuel standards are well within the scope of this test method.
NOTE 3 The presence of cetane improver can reduce the oxidation stability determined by this test method. Limited studies with EHN (2-ethyl hexyl nitrate) indicated, however, that the stability is reduced to an extent which is within the reproducibility of the test method.
NOTE 4 For the purposes of this document, the term “% (V/V)” is used to represent the volume fraction (φ) of a material.
- Draft17 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies basic requirements for hydraulic part-turn valve actuators, both double acting and single acting, used for on-off and modulating control duties.
It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing.
It does not apply to hydraulic actuators which are integral parts of control valves and to hydraulic actuators designed for permanent immersion in fresh or sea water as well as electro-hydraulic actuators.
Other requirements, or conditions of use, different from those indicated in this document can vary upon request.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method to determine the influence of site-applied cement based materials and associated non-cement based products/materials (including pre-packaged mortars) on the odour, flavour, colour, turbidity and total organic carbon (TOC) of test waters after contact with the products.
This document is applicable to site-applied or site-formed cement based materials intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water. It is also applicable to individual constituents of cement based products/materials and to associated non-cement based products/materials.
Site-applied or site-formed cement based materials which cannot be cast as cubes or prisms e.g. some spray applied systems, should be tested as factory made cement based products according to EN 14944−1.
NOTE Tests with the specified test water will not necessarily be representative of materials used in different kinds of waters and especially very soft waters.
- Draft54 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 2477:2005 describes a method for determining the permanent change in dimensions on heating of a shaped insulating refractory product.
- Draft9 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives guidance on the use of colour codes to inform people at risk as well as first response personnel about danger and to express the severity of a situation.
This document is applicable to all types of hazard in any location.
This document does not apply to the method for displaying colour codes, detailed ergonomic considerations related to viewing displays or safety signs covered by ISO 3864-1.
- Draft16 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63461:2024 applies to laboratory model tests of any type of Pelton hydraulic turbine with unit power greater than 5 MW. It contains the rules governing test conduct and provides measures to be taken if any phase of the tests is disputed.
The main objectives of this document are:
- to define the terms and quantities used;
- to specify methods of testing and of measuring the quantities involved, in order to ascertain the hydraulic performance of the model;
- to specify the methods of computation of results and of comparison with guarantees;
- to determine if the contract guarantees that fall within the scope of this document have been fulfilled;
- and to define the extent, content and structure of the final report.
Full application of the procedures herein described is not generally justified for machines with smaller power. Nevertheless, this document can be used for such machines by agreement between the purchaser and the supplier.
- Standard1 pageEnglish and French languagesale 15% off
IEC TR 62282-7-3:2025 is a generic assessment of the feasibility of standardizing accelerated test procedures (both proton exchange membrane (PEM) and oxide ion-conducting solid oxide cell (SOC) technologies) for fuel cell stacks that have been engineered for a specific system application. This document comprises a review of literature and projects, a discussion of the main physical phenomena of interest in accelerated testing campaigns (focusing on the cell and stack levels, not looking at the system as a black box), a compendium of measurement techniques that are applicable, and it suggests a macroscopic approach to the formulation of a representative accelerated testing campaign.
- Technical report29 pagesEnglish languagesale 15% off
IEC TR 63515:2025 provides a conceptual framework for power system resilience. It covers the definition, evaluation metrics and methods, improvement strategies and uses cases of power system resilience. This document is applicable to developing resilient power system and implementing resilience improvement strategies.
This document is not exhaustive, and it is possible to consider other aspects, such as different application scenarios, evaluation methods, and improvement measures.
- Technical report39 pagesEnglish languagesale 15% off
IEC PAS 62443-2-2: 2025 provides guidance on the development, validation, operation, and maintenance of a set of technical, physical, and process security measures called Security Protection Scheme (SPS). The document’s goal is to provide the asset owner implementing an IACS Security Program (SP) with mechanisms and procedures to ensure that the design, implementation and operation of an SPS manage the risks resulting from cyberthreats to each of the IACS included in its operating facility.
The document is based on contents specified in other documents of the IEC 62443 series and explains how these contents can be used to support the development of technical, physical, and process security measures addressing the risks to the IACS during the operation phase.
- Technical specification44 pagesEnglish languagesale 15% off
IEC TS 62271-315:2025 is applicable to direct current (DC) transfer switches designed for indoor or outdoor installation and for operation on HVDC transmission systems having direct voltages of 100 kV and above. DC transfer switches normally include metallic return transfer switches (MRTS), earth return transfer switches (ERTS), neutral bus switches (NBS) and neutral bus earthing switches (NBES).
- Technical specification74 pagesEnglish languagesale 15% off
IEC TR 61850-90-30:2025, which is a Technical Report, describes extensions of the SCL Substation/Process Section allowing the creation of a comprehensive, IED and hardware independent specification of an IEC 61850 based power system.
It addresses how to:
• decompose functions in SCL
• show function classifications in SCL
• relate functions with the SCL Substation and Process Section
• relate functions to Logical Nodes and IEDs/Specification IEDs
• present information flow between functions in a hardware/implementation independent way
• position Functions in relation to "Application Schemes", "Distributed Functions", "Protection Schemes"
• consider the relationship to Basic Application Profiles (BAP) defined in IEC TR 61850-7-6
The document addresses the engineering process as far as it is related to the specification of Functions and their instantiation in IEC 61850 based power system. This includes the impact on the SCL Process Section during system configuration.
The engineering process related to the definition of Applications and their instantiation is addressed in the Basic Application Profile Document (BAP) in IEC TR 61850-7-6.
The System Configuration process is described in IEC 61850-6.
Modifications and extensions of SCL are done in a way to guarantee backwards compatibility.
In addition, this document introduces:
• Some further elements to SCL that improve the content and usefulness of SSD files and facilitate the handling of SCL files for engineering purposes,
• New variants of IED specific files: ISD file and FSD files,
• Evolution of the engineering rights management, to first improve the usage of SED and add a new concept of System Configuration Collaboration (SCC file) which allows collaboration on the same project with different engineers.
- Technical report184 pagesEnglish languagesale 15% off
IEC 60050-831:2025 gives the terms and definitions used in smart cities and smart city systems, as well as general terms pertaining to specific applications and associated technologies. This terminology is consistent with the terminology developed in the other specialized parts of the IEV. It has the status of a horizontal standard in accordance with IEC Guide 108.
- Standard50 pagesEnglish and French languagesale 15% off
IEC 61000-4-2: 2025 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges from operators directly and from personnel to adjacent objects. It additionally specifies ranges of test levels which relate to different environmental, and installation conditions and establishes test procedures. The objective of this document is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which can occur from personnel to objects near the equipment. This document specifies:
- ideal waveform of the discharge current;
- range of test levels;
- test equipment;
- test setup;
- test procedure;
- calibration procedure;
- measurement uncertainty.
This document gives specifications for tests performed in laboratories and guidance to post-installation tests. This document is not intended to specify the tests to be applied to particular apparatus or systems. The main aim is to give a general basic reference to all concerned product committees. The product committees remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. This document excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging. It is not intended for use in characterizing the performance of ESD protection circuit IEC Guide 107.
This document forms Part 4-2 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) added a calibration requirement for ESD generators with air discharge tip;
b) added a normative annex for test setups for particular kind of equipment (see Annex I);
c) added an informative annex for wearable devices (see Annex J);
d) added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E);
e) moved Clause 9 into a new informative annex (see Annex K);
f) improvement of the current calibration procedure;
g) improvement of the measurement uncertainty considerations with examples of uncertainty budgets;
h) because post-installation tests cannot be performed in a controlled environment, this test method has been moved into a new informative Annex G.
- Standard163 pagesEnglish and French languagesale 15% off
IEC 62276:2025 applies to the manufacture of synthetic quartz, lithium niobate (LN), lithium tantalate (LT), lithium tetraborate (LBO), and lanthanum gallium silicate (LGS) single crystal wafers intended for use as substrates in the manufacture of surface acoustic wave (SAW) filters and resonators.
This edition includes the following significant technical changes with respect to the previous edition:
a) The terms and definitions, the technical requirements, sampling frequency, test methods and measurement of transmittance, lightness, colour difference for LN and LT have been added in order to meet the needs of industry development;
b) The term “inclusion” (mentioned in 4.13 and 6.10) and its definition have been added because there was no definition for it in Clause 3;
c) The specification of LTV and PLTV, and the corresponding description of sampling frequency for LN and LT have been added, because they are the key performance parameters for the wafers;
d) The tolerance of Curie temperature specification for LN and LT have been added in order to meet the development requirements of the industry;
e) Measurement of thickness, TV5, TTV, LTV and PLTV have been completed, including measurement principle and method of thickness, TV5, TTV, LTV and PLTV.
- Standard82 pagesEnglish and French languagesale 15% off
IEC 62282-7-2:2025 applies to SOFC cell/stack assembly units, testing systems, instruments and measuring methods, and specifies test methods to test the performance of SOFC cells and stacks. This document is not applicable to small button cells that are designed for SOFC material testing and provide no practical means of fuel utilization measurement. This document is used based on the recommendation of the entity that provides the cell performance specification or for acquiring data on a cell or stack in order to estimate the performance of a system based on it. Users of this document can selectively execute test items suitable for their purposes from those described in this document.
- Standard98 pagesEnglish and French languagesale 15% off
REN/MSG-TFES-15-3
- Standard67 pagesEnglish languagesale 15% off
- Standard67 pagesEnglish languagesale 15% off
- Standard67 pagesEnglish languagesale 10% offe-Library read for1 day
SIGNIFICANCE AND USE
4.1 This practice is useful as a screening basis for acceptance or rejection of transparencies during manufacturing so that units with identifiable flaws will not be carried to final inspection for rejection at that time.
4.2 This practice may also be employed as a go-no go technique for acceptance or rejection of the finished product.
4.3 This practice is simple, inexpensive, and effective. Flaws identified by this practice, as with other optical methods, are limited to those that produce temperature gradients when electrically powered. Any other type of flaw, such as minor scratches parallel to the direction of electrical flow, are not detectable.
SCOPE
1.1 This practice covers a standard procedure for detecting flaws in the conductive coating (heater element) by the observation of polarized light patterns.
1.2 This practice applies to coatings on surfaces of monolithic transparencies as well as to coatings imbedded in laminated structures.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers SEBS (styrene-ethylenebutylene-styrene)-modified mopping asphalt intended for use in built-up roof construction, construction of some modified bitumen systems, construction of bituminous vapor retarder systems, and for adhering insulation boards used in various types of roofing systems. This specification is intended as a material specification and issues regarding the suitability of specific roof constructions or application techniques are beyond its scope. The specified tests and property values are intended to establish minimum properties. In place system design criteria or performance attributes are factors beyond the scope of this specification. The base asphalt shall be prepared from crude petroleum and the SEBS-modified asphalt shall incorporate sufficient SEBS as the primary polymeric modifier. The SEBS modified asphalt shall be homogeneous and free of water and shall conform to the prescribed physical properties including (1) softening point before and after heat exposure, (2) softening point change, (3) flash point, (4) penetration before and after heat exposure, (5) penetration change, (6) solubility in trichloroethylene, (7) tensile elongation, (8) elastic recovery, and (9) low temperature flexibility. The sampling and test methods to determine compliance with the specified physical properties, as well as the evaluation for stability during heat exposure are detailed.
SCOPE
1.1 This specification covers SEBS (styrene-ethylene-butylene-styrene)-modified asphalt intended for use in built-up roof construction, construction of some modified bitumen systems, construction of bituminous vapor retarder systems, and for adhering insulation boards used in various types of roof systems.
1.2 This specification is intended as a material specification. Issues regarding the suitability of specific roof constructions or application techniques are beyond its scope.
1.3 The specified tests and property values used to characterize SEBS-modified asphalt are intended to establish minimum properties. In-place system design criteria or performance attributes are factors beyond the scope of this specification.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.5 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification3 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
3.1 These tests are useful in sampling and testing solvent bearing bituminous compounds to establish uniformity of shipments.
SCOPE
1.1 These test methods cover procedures for sampling and testing solvent bearing bituminous compounds for use in roofing and waterproofing.
1.2 The test methods appear in the following order:
Section
Sampling
4
Uniformity
5
Weight per gallon
6
Nonvolatile content
7
Solubility
8
Ash content
9
Water content
10
Consistency
11
Behavior at 60 °C [140 °F]
12
Pliability at –0 °C [32 °F]
13
Aluminum content
14
Reflectance of aluminum roof coatings
15
Strength of laps of rolled roofing adhered with roof adhesive
16
Adhesion to damp, wet, or underwater surfaces
17
Mineral stabilizers and bitumen
18
Mineral matter
19
Volatile organic content
20
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish languagesale 15% off
ABSTRACT
This specification establishes the manufacture, testing, and performance requirements of two types of asphalt-based emulsions for use in a relatively thick film as a protective coating for metal surfaces. Type I are quick-setting emulsified asphalt suitable for continuous exposure to water within a few days after application and drying. Type II, on the other hand, are emulsified asphalt suitable for continuous exposure to the weather, only after application and drying. Upon being sampled appropriately, the materials shall conform to composition requirements as to density, residue by evaporation, nonvolatile matter soluble in trichloroethylene, and ash and water content. They shall also adhere to performance requirements as to uniformity, consistency, stability, wet flow, firm set, heat test, flexibility, resistance to water, and loss of adhesion.
SCOPE
1.1 This specification covers emulsified asphalt suitable for application in a relatively thick film as a protective coating for metal surfaces.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification2 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers grades of fuel oil intended for use in various types of fuel-oil-burning equipment under various climatic and operating conditions. These grades include the following: Grades No. 1 S5000, No. 1 S500, No. 2 S5000, and No. 2 S500 for use in domestic and small industrial burners; Grades No. 1 S5000 and No. 1 S500 adapted to vaporizing type burners or where storage conditions require low pour point fuel; Grades No. 4 (Light) and No. 4 (Heavy) for use in commercial/industrial burners; and Grades No. 5 (Light), No. 5 (Heavy), and No. 6 for use in industrial burners. Preheating is usually required for handling and proper atomization. The grades of fuel oil shall be homogeneous hydrocarbon oils, free from inorganic acid, and free from excessive amounts of solid or fibrous foreign matter. Grades containing residual components shall remain uniform in normal storage and not separate by gravity into light and heavy oil components outside the viscosity limits for the grade. The grades of fuel oil shall conform to the limiting requirements prescribed for: (1) flash point, (2) water and sediment, (3) physical distillation or simulated distillation, (4) kinematic viscosity, (5) Ramsbottom carbon residue, (6) ash, (7) sulfur, (8) copper strip corrosion, (9) density, and (10) pour point. The test methods for determining conformance to the specified properties are given.
SCOPE
1.1 This specification (see Note 1) covers grades of fuel oil intended for use in various types of fuel-oil-burning equipment under various climatic and operating conditions. These grades are described as follows:
1.1.1 Grades No. 1 S5000, No. 1 S500, No. 1 S15, No. 2 S5000, No. 2 S500, and No. 2 S15 are middle distillate fuels for use in domestic and small industrial burners. Grades No. 1 S5000, No. 1 S500, and No. 1 S15 are particularly adapted to vaporizing type burners or where storage conditions require low pour point fuel.
1.1.2 Grades B6–B20 S5000, B6–B20 S500, and B6–B20 S15 are middle distillate fuel/biodiesel blends for use in domestic and small industrial burners.
1.1.3 Grades No. 4 (Light) and No. 4 are heavy distillate fuels or middle distillate/residual fuel blends used in commercial/industrial burners equipped for this viscosity range.
1.1.4 Grades No. 5 (Light), No. 5 (Heavy), and No. 6 are residual fuels of increasing viscosity and boiling range, used in industrial burners. Preheating is usually required for handling and proper atomization.
Note 1: For information on the significance of the terminology and test methods used in this specification, see Appendix X1.
Note 2: A more detailed description of the grades of fuel oils is given in X1.3.
1.2 This specification is for the use of purchasing agencies in formulating specifications to be included in contracts for purchases of fuel oils and for the guidance of consumers of fuel oils in the selection of the grades most suitable for their needs.
1.3 Nothing in this specification shall preclude observance of federal, state, or local regulations which can be more restrictive.
1.4 The values stated in SI units are to be regarded as standard.
1.4.1 Non-SI units are provided in Table 1 and Table 2 and in 7.1.2.1/7.1.2.2 because these are common units used in the industry.
Note 3: The generation and dissipation of static electricity can create problems in the handling of distillate burner fuel oils. For more information on the subject, see Guide D4865.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification13 pagesEnglish languagesale 15% off
- Technical specification13 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 Since the information provided by this test method is largely qualitative in nature, specific limits covering the following characteristics are required in referring to this test method in specifications for kerosene:
5.1.1 Duration of the test: 16 h is understood, if not otherwise specified;
5.1.2 Permissible change in flame shape and dimensions during the test;
5.1.3 Description of the acceptable appearance of the chimney deposit.
SCOPE
1.1 This test method covers the qualitative determination of the burning properties of kerosene to be used for illuminating purposes. (Warning—Combustible. Vapor harmful.)
Note 1: The corresponding Energy Institute (IP) test method is IP 10 which features a quantitative evaluation of the wick-char-forming tendencies of the kerosene, whereas Test Method D187 features a qualitative performance evaluation of the kerosene. Both test methods subject the kerosene to somewhat more severe operating conditions than would be experienced in typical designated applications.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific warning statements appear throughout the test method.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 The kinematic viscosity characterizes flow behavior. The method is used to determine the consistency of liquid asphalt as one element in establishing the uniformity of shipments or sources of supply. The specifications are usually at temperatures of 60 and 135 °C.
Note 3: The quality of the results produced by this standard are dependent on the competence of the personnel performing the procedure and the capability, calibration, and maintenance of the equipment used. Agencies that meet the criteria of Specification D3666 are generally considered capable of competent and objective testing, sampling, inspection, etc. Users of this standard are cautioned that compliance with Specification D3666 alone does not completely ensure reliable results. Reliable results depend on many factors; following the suggestions of Specification D3666 or some similar acceptable guideline provides a means of evaluating and controlling some of those factors.
SCOPE
1.1 This test method covers procedures for the determination of kinematic viscosity of liquid asphalts, road oils, and distillation residues of liquid asphalts all at 60 °C [140 °F] and of liquid asphalt binders at 135 °C [275 °F] (see table notes, 11.1) in the range from 6 to 100 000 mm2/s [cSt].
1.2 Results of this test method can be used to calculate viscosity when the density of the test material at the test temperature is known or can be determined. See Annex A1 for the method of calculation.
Note 1: This test method is suitable for use at other temperatures and at lower kinematic viscosities, but the precision is based on determinations on liquid asphalts and road oils at 60 °C [140 °F] and on asphalt binders at 135 °C [275 °F] only in the viscosity range from 30 to 6000 mm2/s [cSt].
Note 2: Modified asphalt binders or asphalt binders that have been conditioned or recovered are typically non-Newtonian under the conditions of this test. The viscosity determined from this method is under the assumption that asphalt binders behave as Newtonian fluids under the conditions of this test. When the flow is non-Newtonian in a capillary tube, the shear rate determined by this method may be invalid. The presence of non-Newtonian behavior for the test conditions can be verified by measuring the viscosity with viscometers having different-sized capillary tubes. The defined precision limits in 11.1 may not be applicable to non-Newtonian asphalt binders.
1.3 Warning—Mercury has been designated by the United States Environmental Protection Agency (EPA) and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) or Safety Data Sheet (SDS) for details and the EPA’s website—http://www.epa.gov/mercury/faq.htm—for additional information. Users should be aware that selling mercury, mercury-containing products, or both, in your state may be prohibited by state law.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.5 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior ...
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
4.1 This procedure measures the amount of hydrogen gas generation potential of aluminized emulsion roof coating. There is the possibility of water reacting with aluminum pigment to generate hydrogen gas. This situation is to be avoided, so this test was designed to evaluate coating formulations and assess the propensity to gassing.
SCOPE
1.1 This test method covers a hydrogen gas and stability test for aluminum emulsified asphalt coatings.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
4.1 Flash X-ray facilities provide intense bremsstrahlung radiation environments, usually in a single sub-microsecond pulse, which often fluctuates in amplitude, shape, and spectrum from shot to shot. Therefore, appropriate dosimetry must be fielded on every exposure to characterize the environment, see ICRU Report 34. These intense bremsstrahlung sources have a variety of applications which include the following:
(1) Studies of the effects of X-rays and gamma rays on materials.
(2) Studies of the effects of radiation on electronic devices such as transistors, diodes, and capacitors.
(3) Computer code validation studies.
4.2 This guide is written to assist the experimenter in selecting the needed dosimetry systems for use at pulsed X-ray facilities. This guide also provides a brief summary on how to use each of the dosimetry systems. Other guides (see Section 2) provide more detailed information on selected dosimetry systems in radiation environments and should be consulted after an initial decision is made on the appropriate dosimetry system to use. There are many key parameters which describe a flash X-ray source, such as dose, dose rate, spectrum, pulse width, etc., such that typically no single dosimetry system can measure all the parameters simultaneously. However, it is frequently the case that not all key parameters must be measured in a given experiment.
SCOPE
1.1 This guide provides assistance in selecting and using dosimetry systems in flash X-ray experiments. Both dose and dose rate techniques are described.
1.2 Operating characteristics of flash X-ray sources are given, with emphasis on the spectrum of the photon output.
1.3 Assistance is provided to relate the measured dose to the response of a device under test (DUT). The device is assumed to be a semiconductor electronic part or system.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide19 pagesEnglish languagesale 15% off
- Guide19 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 This test method measures a lubricant's ability to protect hypoid final drive axles from abrasive wear, adhesive wear, plastic deformation, and surface fatigue when subjected to low-speed, high-torque conditions. Lack of protection can lead to premature gear or bearing failure, or both.
5.2 This test method is used, or referred to, in specifications and classifications of rear-axle gear lubricants such as:
5.2.1 Specification D7450.
5.2.2 American Petroleum Institute (API) Publication 1560.
5.2.3 SAE J308.
5.2.4 SAE J2360.
SCOPE
1.1 This test method, commonly referred to as the L-37-1 test, describes a test procedure for evaluating the load-carrying capacity, wear performance, and extreme pressure properties of a gear lubricant in a hypoid axle under conditions of low-speed, high-torque operation.3
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.2.1 Exceptions—Where there is no direct SI equivalent such as National Pipe threads/diameters, tubing size, or where there is a sole source supply equipment specification.
1.2.1.1 The drawing in Annex A6 is in inch-pound units.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are provided in 7.2 and 10.1.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard18 pagesEnglish languagesale 15% off
- Standard18 pagesEnglish languagesale 15% off
RTS/TSGC-0329521vh50
- Standard77 pagesEnglish languagesale 15% off
RTS/TSGC-0329523vh70
- Standard46 pagesEnglish languagesale 15% off
DEN/ERM-TGAERO-31-2
- Standard38 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
RTS/LI-00190-2
- Standard61 pagesEnglish languagesale 15% off
RTS/TSGR-0436171vf10
- Standard40 pagesEnglish languagesale 15% off
RTS/TSGS-0333128vf40
- Standard69 pagesEnglish languagesale 15% off
RTS/TSGC-0631130ve21
- Standard23 pagesEnglish languagesale 15% off