IEC 63580:2026 provides guidance to manufacturers of measuring equipment for electrical and electromagnetic quantities (ME3Q) in evaluating and improving the environmental impact of their products, and in enabling effective communication using common references for environmental information throughout the supply chain.
This document covers only the below fixed installed measuring equipment:
IEC 61557-12, power metering and monitoring devices (PMD);
IEC 62586-1, power quality instruments (PQI);
IEC 60688, transducers (TRD);
IEC 62974-1, devices for data management (DDM).

  • Standard
    47 pages
    English language
    sale 15% off
  • Standard
    50 pages
    French language
    sale 15% off

IEC 62046: 2026 specifies requirements for the selection, positioning, configuration and commissioning of sensitive protective equipment (SPE) to detect the momentary or continued presence of persons in order to protect those persons from dangerous part(s) of machinery in industrial applications. This document covers the application of electro-sensitive protective equipment (ESPE) specified in the IEC 61496 series and pressure-sensitive mats and floors specified in ISO 13856‑1. It takes into account the characteristics of the machinery, the sensitive protective equipment, the environment and human interaction by persons of 14 years and older. This document includes informative annexes to provide guidance on the application of sensitive protective equipment to detect the presence of persons. These annexes contain examples to illustrate the principles of this document. These examples are not intended to be the only solutions to a given application and are not intended to restrict innovation or advancement of technology. The examples are provided only as representative solutions to illustrate some of the concepts of integration of sensitive protective equipment, and have been simplified for clarity, so they can be incomplete. It is intended that this document is used in conjunction with ISO 13855. This second edition cancels and replaces the first edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the first edition:
a) restructuring of the document to aid the user;
b) additional information on vision and radar systems;
c) muting requirements have been updated;
d) information on whole body access has been added;
e) whole body access has also been covered in more detail;
f) alignment to changes in ISO 13855.

  • Standard
    128 pages
    English language
    sale 15% off
  • Standard
    134 pages
    French language
    sale 15% off

IEC 62820‑1‑2:2026 specifies the technical requirements for the composition, functions, performance and test methods of building intercom systems using the Internet protocol (IP), and it is a supplement to IEC 62820‑1‑1. This document is applicable to the IP building intercom systems for both residential and commercial buildings.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    42 pages
    English and French language
    sale 15% off
  • Standard
    42 pages
    English and French language
    sale 15% off

IEC 61300-3-30 describes a method for measuring the endface geometry of rectangular multifibre ferrules having an IEC defined optical interface. The primary attributes are fibre position relative to the endface, endface angle relative to the guide holes, fibre tip radii and core dip for multimode fibres.
This edition includes the following significant technical changes with respect to the previous edition:
a) clarification of region diameter symbols;
b) introduction of x116 and x132 region of interest (ROI) to support MT-16 and MT-32 ferrule types;
c) preparation of geometry limit (GL) parameter tables for 16-, 24- and 32-fibre ferrules;
d) clarification of the neighbouring fibres definition when computing adjacent height;
e) improvement of figures in Annexes.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    21 pages
    French language
    sale 15% off

IEC 63585:2026 This document gives guidelines to the transformer operator in evaluating dissolved gas analysis (DGA) data obtained from natural ester according to IEC 62770 and synthetic ester according to IEC 61099 in liquid filled transformers and similar equipment.
This document includes the following:
- gas generation in a natural and synthetic ester-filled transformer;
- DGA interpretation methods;
- gas concentration guide values valid for the use of DGA interpretation tools;
- nterpretation of the dissolved gas analysis results;
- recommended actions based on the interpretation of dissolved gas analysis results;
- examples of faulty equipment.

  • Standard
    43 pages
    English language
    sale 15% off
  • Standard
    46 pages
    French language
    sale 15% off

This document specifies the syntax and semantics of description schemes for representing data exchanged by media things (e.g. media sensors, media actuators, and media storages). Moreover, it specifies the APIs to exchange these data between media things. The following interfaces are under the scope of this document: APIs for accessing media sensors, actuators, storage, managers, controllers, and aggregators; structured data formats (XML) representing media thing’s base data types, including sensors, actuators, storage, managers, aggregators, controllers, and their elements; structured data formats (XML) representing the media sensor’s output data; and, structured data formats (XML) representing media actuator’s commands. This document does not specify how sensing and actuating are carried out but defines the interfaces between the media things.

  • Standard
    265 pages
    English language
    sale 15% off

This document defines important terms used in the heat treatment of ferrous materials. Annex A provides an alphabetical list of terms defined in this document, as well as their equivalents in French, German, Russian, Chinese and Japanese. Table 1 shows the various iron-carbon (Fe-C) phases.

  • Standard
    56 pages
    English language
    sale 15% off
  • Draft
    68 pages
    French language
    sale 15% off

This document provides a description of a set of common technologies and techniques used in conjunction with cloud computing. These include: virtual machines (VMs) and hypervisors; containers and container management systems (CMSs); serverless computing; microservices architecture; automation; platform as a service systems and architecture; storage services; security, scalability and networking as applied to the above cloud computing technologies.

  • Standard
    49 pages
    English language
    sale 15% off

This standard is a product family standard dealing with safety after repair, refurbishment, and remanufacturing of an appliance already placed on the market and subsequent safety testing of appliances within the scope of IEC TC 61 and its subcommittees. This document takes precedence over horizontal and generic standards covering the same subject. When a Part 2 of the IEC TS 63457-2 series does not include additional requirements to cover hazards dealt with in this document, this document applies. All tests included in this document are conducted by a qualified person or by a supervised technician for specified activities. The concept of upgrade of an appliance and use of reused components are addressed in informative Annex A and informative Annex B. Additional requirements for upgrade apply as given in informative Annex B. Inspection and test documentation are prepared, for example, according to informative Annex C. Furthermore, a guidance on preparing a service manual by the manufacturer or remanufacturer is given in Annex D.

  • Draft
    31 pages
    English language
    e-Library read for
    1 day

This document specifies a method for the determination of polyacrylate (PA) superabsorbent materials in airborne dust by measurement of sodium (Na) by atomic absorption spectrometry (AAS). This method is applicable to the determination of collected superabsorbent powder in the range between 0,2 µg and 60 µg (limit of detection near 0,2 µg) of superabsorbent powders. It is applicable to polyacrylate superabsorbent materials, which occur in hygiene products including urine-absorbing aids for incontinent persons. The test methods are addressed to the material exclusively. They are not intended to be used, and are not applicable for use, with finished manufactured urine-absorbing aids.

  • Standard
    9 pages
    English language
    sale 15% off

This document specifies requirements for the physical and chemical properties of dentifrices and provides guidelines for suitable test methods. It also specifies requirements for the marking, labelling and packaging of dentifrices. This document is applicable to dentifrices, including toothpastes, destined to be used by consumers on a daily basis with a toothbrush to promote oral hygiene. This document does not apply to specific qualitative and quantitative requirements for freedom from biological and toxicological hazards. These are covered in ISO 7405 and ISO 10993-1.

  • Standard
    22 pages
    English language
    sale 15% off
  • Standard
    23 pages
    French language
    sale 15% off

This document specifies a method for determining the resistance of all forms of leather to visible soiling through repeated contact with soiled objects. It provides a physical pretreatment routine for leathers that can be vulnerable to loss of soiling resistance while in service, prior to conducting further tests such as cleaning.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

This document specifies controls, purpose, and guidance for implementing controls, to meet the requirements identified by a risk and impact assessment related to the protection of personally identifiable information (PII). In particular, this document specifies requirements and guidance based on ISO/IEC 27002, taking into consideration the controls for processing PII that can be applicable within the context of an organization's information security risk environment(s). This document is applicable to all types and sizes of organizations acting as PII controllers (as defined in ISO/IEC 29100), including public and private companies, government entities and not-for-profit organizations that process PII, in particular, organizations that do not establish or operate a privacy information management system.

  • Standard
    41 pages
    English language
    sale 15% off
  • Draft
    63 pages
    French language
    sale 15% off

This document specifies requirements for storm water management systems on wastewater treatment plants. It does not refer to storm water management systems in wastewater collection and conveyance networks (sewer systems). Regardless of the location and the technical requirements of this document, storm water management systems can be regarded as part of the sewer system in accordance with EN 752 and EN 16933.
This document specifies requirements for separation, storage, treatment, discharge and return of storm water within wastewater treatment plants.
NOTE A storm water management system at the wastewater treatment plant is only required where such a system is not provided within the sewer system, limiting the flow to the wastewater treatment plants see EN 752 and EN 16933 (all parts).

  • Standard
    14 pages
    English language
    e-Library read for
    1 day

This document describes methods for specifying and evaluating the locomotion performance of legged robots. The tests listed in this document are mainly used to evaluate the complete machine. They can be also used for sample test, qualification test or check-and-accept test. This document is not intended for the verification or validation of safety requirements.

  • Standard
    18 pages
    English language
    sale 15% off

IEC 62788-2-1:2023 specifies the safety requirements for flexible polymeric front- and backsheet constructions, which are intended for use as relied-upon insulation in photovoltaic (PV) modules. The specifications in this document define the specific requirements of polymeric front- or backsheet constructions on the component level and cover mechanical, electrical, visual and thermal characterization in an unexposed state and/or after ageing. This document covers class II and class 0 modules, as defined in IEC 61730-1. Class III modules are out of scope. This document provides the requirements for qualification of front- and backsheets to be used in module safety qualification according to IEC 61730-1. Test method descriptions are provided in IEC TS 62788-2, along with additional characterization methods useful for performance or quality assurance.

  • Standard
    60 pages
    English language
    sale 15% off
  • Standard
    65 pages
    English and French language
    sale 15% off

This document provides requirements and recommendations for carrying out comparative testing of alpine skis with the objective of evaluating the performance characteristics. It is applicable to alpine skis in accordance with ISO 6289.

  • Standard
    5 pages
    English language
    sale 15% off

This document lists circular economy principles and provides guidance for circular economy across the textile value chain and value network and circularity for textile products.
This document applies to textiles, textile products, including non-textile components and materials.
This document excludes leather, fur products and footwear.

  • Technical specification
    39 pages
    English language
    e-Library read for
    1 day

IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
The contents of the corrigendum of November 2023 have been included in this copy.

  • Standard
    1 page
    English and French language
    sale 15% off

This document is concerned with linear, that is, straight-line, calibration functions that describe the relationship between two variables and , namely, functions of the form . Although many of the principles apply to more general types of calibration function, the approaches described exploit the simple form of the straight-line calibration function wherever possible. Values of the parameters and are estimated based on measured data points , Various cases are considered relating to the nature of the uncertainties associated with these data. No assumption is made that the errors relating to the are homoscedastic (having equal variance), and similarly for the when the errors are not negligible. Estimates of the parameters and are determined using least‑squares’ methods. The emphasis of this document is on using the method most appropriate for the type of measured data, that is, respecting the associated uncertainties. The most general type of covariance matrix associated with the measured data is treated, but important special cases that lead to simpler calculations are described in detail. For all cases considered, methods for validating the use of the straight-line calibration functions and for evaluating the uncertainties and covariance associated with the parameter estimates are given. The document also describes the use of the estimates of the calibration-function parameters and their associated uncertainties and covariance to predict a value of and its associated standard uncertainty given a measured value of and its associated standard uncertainty. NOTE 1 The document does not give a general treatment of outliers in measured data, although the validation tests given can be used to indicate discrepant data. ISO 16269-4 can be consulted for guidance. NOTE 2 The document describes a method to evaluate the uncertainties associated with the measured data when those uncertainties are known only up to a scale factor (see Annex D).

  • Standard
    78 pages
    English language
    sale 15% off

This document specifies performance requirements and test methods for neck laceration protectors for use in ice hockey. This document is applicable to neck laceration protectors worn by ice hockey players, including goalkeepers, and referees. This document does not address protection of the neck from the impact of pucks, sticks or other objects.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

This document specifies the conditioning atmospheres and the method for conditioning samples of intact, empty paper sacks before and during testing.

  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off

This document specifies requirements for fire detection, alarm systems, equipment shutdown, information and communication systems, emergency brake systems and fire fighting systems to cover the objectives specified in EN 45545-1:2013.
The measures and requirements specified in this document aim to protect passengers and staff in railway vehicles in the event of a fire on board by alerting staff and passengers to a fire, delaying the fire development and controlling the movement of smoke.
It is not within the scope of this document to describe measures that ensure the preservation of the railway vehicles in the event of a fire.
This document is applicable to railway vehicles specified in EN 45545-1:2013.

  • Standard
    17 pages
    English language
    e-Library read for
    1 day

This document provides a multi-dimensional assessment framework of data spaces maturity, considering the different needs of data spaces, their participants, domain, or scope.
Specifically, it defines a maturity model concept, structure, methodology and measurable criteria, with related requirements and guidance for the assessment of data space maturity.
This document applies to all types of organizations, regardless of their type or size.

  • Technical specification
    42 pages
    English language
    e-Library read for
    1 day

This document specifies methods of determining the luminous and solar characteristics of glazing in buildings. These characteristics can serve as a basis for lighting, heating and cooling calculations of rooms and permit comparison between different types of glazing. This document applies both to conventional glazing and to absorbing or reflecting solar-control glazing, used as vertical or horizontal glazed apertures. The appropriate formulae for single, double and triple glazing are given. A matrix method is provided as an alternative calculation method. This document introduces a method to determine the luminous and solar properties of building-integrated photovoltaic (BIPV) glazing. This document is accordingly applicable to all transparent materials except those which show significant transmission in the wavelength region 5 µm to 50 µm of ambient temperature radiation, such as certain plastic materials. Materials with light-scattering properties for incident radiation are dealt with as conventional transparent materials subject to certain conditions (see 5.3). Angular light and solar properties of glass in building are excluded from this document. However, research work in this area is summarised in References [1], [2] and [3]. Guidance on the measurement of luminous and spectral properties of glass can be found in Reference [4]. Vacuum insulating glass (VIG) is excluded from the scope of this document. For determination of the g value of VIG, refer to ISO 19916-1[5].

  • Standard
    94 pages
    English language
    sale 15% off

IEC 62275:2022 specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices as a means used for managing or securing the wiring systems in electrical installations. Cable ties and associated fixing devices can also be suitable for other applications, such as support of wiring systems, and where so used, additional requirements can apply. This fourth edition cancels and replaces the third edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - scope clarification, - new definitions, - deletion of the exception for the stabilization of the moisture content, - possibility to carry out tensile strength tests with dead weights, - differentiation of rubber and acrylic adhesive fixings, - clarification for mechanical testing of integral devices, - clarifications on Table 6, - clarifications in 9.1, - the minimum installation temperature test for cable ties is carried out only when the declared minimum temperature is lower than 0 °C, - a requirement that metallic cable ties be classified according to 6.2.3, - definition of colours to be tested for contribution to fire, - addition of a "some countries" note in Clause 10, - clarification of the mounting of fixing devices in the resistance to ultraviolet light test, - clarification on the testing of integral devices in the resistance to ultraviolet light test.

  • Draft
    40 pages
    English language
    e-Library read for
    1 day

This document provides a method to calculate the GHG emissions from an LNG liquefaction plant, onshore or offshore.
The frame of this document ranges from the inlet flange of the LNG plant’s inlet facilities up to and including the offloading arms to truck, ship or railcar loading. The upstream supply of gas up to the inlet flange of the inlet facilities and the distribution of LNG downstream of the loading arms are only covered in general terms.
This document covers:
—     all facilities associated with producing LNG, including reception facilities, condensate unit (where applicable), pre-treatment units (including but not limited to acid gas removal, dehydration, mercury removal, heavies removal), LPG extraction and fractionation (where applicable), liquefaction, LNG storage and loading, Boil-Off-Gas handling, flare and disposal systems, imported electricity or on-site power generation and other plant utilities and infrastructure (e.g. marine and transportation facilities).
—     natural gas liquefaction facilities associated with producing other products (e.g. domestic gas, condensate, LPG, sulphur, power export) to the extent required to allocate GHG emissions to the different products.
—     all GHG emissions associated with producing LNG. These emissions spread across scope 1, scope 2 and scope 3 of the responsible organization. Scope 1, 2 and 3 are defined in this document. All emissions sources are covered including flaring, combustion, cold vents, process vents, fugitive leaks and emissions associated with imported energy.
The LNG plant is considered “under operation”, including emissions associated with initial start-up, maintenance, turnaround and restarts after maintenance or upset. The construction, commissioning, extension and decommissioning phases are excluded from this document but can be assessed separately.
The emissions resulting from boil-off gas management during loading of the ship or any export vehicle are covered by this document. The emissions from a ship at berth, e.g. mast venting are not covered by this document.
This document describes the allocation of GHG emissions to LNG and other hydrocarbon products where other products are produced (e.g. LPG, domestic gas, condensates, sulphur, etc.).
This document defines preferred units of measurement and necessary conversions.
This document also recommends instrumentation and estimations methods to monitor and report GHG emissions. Some emissions are measured and some are estimated.
This document is applicable to the LNG industry.
Applications include the provision of method to calculate GHG emissions through a standardized and auditable method, a means to determine their carbon footprint.

  • Standard
    39 pages
    English language
    e-Library read for
    1 day

This document provides a workflow comprising experimental procedures and flaw detection algorithms aimed at locating flaws in parts produced during the powder bed fusion-laser-based (PBF-LB) process of metals. It emphasizes the use of coaxial photodiode-based in-situ monitoring and statistical and clustering machine learning algorithms, particularly for detecting lack of fusion-induced flaws. The workflow delineates setting thresholds for statistical detection and determining the number of clusters for machine learning algorithms, utilizing intentional seeded flaws in parts. Validation procedures are provided through computed tomography scanner data. Hardware limitations and considerations for multi-laser processes are addressed, with attention to potential issues.

  • Technical report
    32 pages
    English language
    e-Library read for
    1 day

IEC 60909-0:2026 This part of IEC 60909 is applicable to the calculation of short-circuit currents in low-voltage three-phase AC systems, in high-voltage three-phase AC systems, and operating at a nominal frequency of 50 Hz or 60 Hz.
Systems at highest voltages of 550 kV and above with long transmission lines are outside the scope of this document.

  • Standard
    71 pages
    English language
    sale 15% off
  • Standard
    74 pages
    French language
    sale 15% off

IEC 62146-1:2026 is available as IEC 62146-1:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62146-1:2026 includes generalities of capacitors used on alternating current circuit-breakers and introduces specifications for grading capacitors. Regarding grading capacitors, their function is to control the voltage distribution across the individual interrupter units of a multi-break circuit-breaker.
This document applies to grading capacitors falling into one or both of the following categories for:
- mounting on air-insulated circuit-breakers.
- mounting on enclosed circuit-breakers (for example immersed in insulating gas, in oil, etc.).
The object of this document is:
- to define uniform rules regarding performances, testing and rating;
- to define specific safety rules;
- to provide a guidance for installation and operation.
This document does not apply to capacitors not directly associated with high-voltage alternating current circuit-breakers.

  • Standard
    41 pages
    English language
    sale 15% off
  • Standard
    90 pages
    English language
    sale 15% off
  • Standard
    44 pages
    French language
    sale 15% off

This document specifies a four-pole connector system for implantable cardiac rhythm management (CRM) devices that have electrogram sensing and pacing functions with or without defibrillation capability. This document includes requirements for the connector portion of an implantable lead and for the mating connector cavity attached to an implantable pulse generator. Key dimensions and performance requirements are specified together with appropriate test methods. This document establishes two types of connector assembly with their configurations, which are not intended to be interchangeable: a high-voltage connector: a connector that can have either two low-voltage contacts combined with one or two high-voltage contacts, or only two high-voltage contacts; a “low-voltage only connector”: a connector that has either three or four low-voltage contacts. This document specifies a dimensional lockout feature that prevents the low-voltage contacts of the lead connectors from contacting the high-voltage contacts of high-voltage connector cavities. This document does not replace or provide alternatives for unipolar or bipolar connector International Standards that currently exist (such as ISO 11318[2] and ISO 5841-3[1]). This document is not applicable to high-voltage systems with intended outputs greater than 1 000 V or systems with an electric flow greater than 50 A. This document is not applicable to systems which include sensors or unique electrodes that are not capable of conventional pacing electrogram sensing or defibrillation functions. This document does not specify all connector features and it does not address all aspects of functional compatibility, safety or reliability of leads and pulse generators assembled into a system. This document does not include requirements for accessories or adaptors used with four-pole connectors. Refer to Annex P for more information on connector-related products. NOTE 1 The safety, reliability, biocompatibility, biostability and function of any particular part are the responsibility of the manufacturer. NOTE 2 Lead and pulse generator connector systems not conforming to this document can be safe and reliable and can have clinical advantages.

  • Standard
    107 pages
    English language
    sale 15% off

IEC 63223-1:2026 provides an overview of asset management, its principles and value creation options for the management of network assets in power systems.
This document can be applied to all types of network assets and by all types and sizes of power network companies. The term power network company does not necessarily refer to legally structured companies.
In this document, network assets refer mainly to the physical assets of the electrical energy network, meaning items, equipment, or systems that have potential or actual value for the electric company and are part of the power lines and substations responsible for the transmission and distribution of electrical energy. Examples of network assets that can be included in the asset portfolio of a power network company are presented in IEC 63223-2:2026, 4.2.2.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    24 pages
    French language
    sale 15% off

This document provides a method to calculate the GHG emissions from an LNG liquefaction plant, onshore or offshore.
The frame of this document ranges from the inlet flange of the LNG plant’s inlet facilities up to and including the offloading arms to truck, ship or railcar loading. The upstream supply of gas up to the inlet flange of the inlet facilities and the distribution of LNG downstream of the loading arms are only covered in general terms.
This document covers:
—     all facilities associated with producing LNG, including reception facilities, condensate unit (where applicable), pre-treatment units (including but not limited to acid gas removal, dehydration, mercury removal, heavies removal), LPG extraction and fractionation (where applicable), liquefaction, LNG storage and loading, Boil-Off-Gas handling, flare and disposal systems, imported electricity or on-site power generation and other plant utilities and infrastructure (e.g. marine and transportation facilities).
—     natural gas liquefaction facilities associated with producing other products (e.g. domestic gas, condensate, LPG, sulphur, power export) to the extent required to allocate GHG emissions to the different products.
—     all GHG emissions associated with producing LNG. These emissions spread across scope 1, scope 2 and scope 3 of the responsible organization. Scope 1, 2 and 3 are defined in this document. All emissions sources are covered including flaring, combustion, cold vents, process vents, fugitive leaks and emissions associated with imported energy.
The LNG plant is considered “under operation”, including emissions associated with initial start-up, maintenance, turnaround and restarts after maintenance or upset. The construction, commissioning, extension and decommissioning phases are excluded from this document but can be assessed separately.
The emissions resulting from boil-off gas management during loading of the ship or any export vehicle are covered by this document. The emissions from a ship at berth, e.g. mast venting are not covered by this document.
This document describes the allocation of GHG emissions to LNG and other hydrocarbon products where other products are produced (e.g. LPG, domestic gas, condensates, sulphur, etc.).
This document defines preferred units of measurement and necessary conversions.
This document also recommends instrumentation and estimations methods to monitor and report GHG emissions. Some emissions are measured and some are estimated.
This document is applicable to the LNG industry.
Applications include the provision of method to calculate GHG emissions through a standardized and auditable method, a means to determine their carbon footprint.

  • Standard
    39 pages
    English language
    e-Library read for
    1 day

This document specifies design requirements for non-powered means of access installed on cranes.
Slidable, retractable means of access are excluded from the scope, except movable hoop guards.
This document covers means of access to control stations and all access required for maintenance, certain erection and dismantling operations.
For those cranes which are intended to be erected and dismantled frequently to change their places of work, e.g. tower cranes, specific requirements for the access needed during these operations are not covered by this document and can be given in the appropriate European Standards for specific crane types.
Lighting of means of access is not covered by this document and can be given in the appropriate European Standards for specific crane types.
Specification of the required rescue equipment, use of rescue equipment and the adaptation of crane access to the selected rescue equipment, are not covered by this document and can be given in the appropriate European Standards for specific crane types.
NOTE   Specific requirements for access on particular types of cranes are given in the appropriate European Standard for the particular crane type.
The requirements given in this document do not take into account the safety distances related to:
-   guarding against hazard from moving parts;
-   relative movement between crane and adjacent structure or the ground/floor;
-   hazardous surface temperature;
-   electrical equipment.
The significant hazards covered by this document are identified in Annex A.
This document is not applicable to cranes manufactured before the date of its publication.

  • Draft
    30 pages
    English language
    e-Library read for
    1 day

This document defines basic terms, symbols and units of measurement for the field of laser technology in order to unify the terminology, and to arrive at clear definitions and reproducible tests of beam parameters and laser-oriented product properties.
NOTE            The laser hierarchical vocabulary laid down in this document differs from that given in IEC 60825–1. ISO and IEC have discussed this difference and agree that it reflects the different purposes for which the two standards serve. For more details, see informative Annex A.

  • Draft
    24 pages
    English language
    e-Library read for
    1 day

This document specifies a method for determining the fire resistance of air transfer grilles (ATG).
It is applicable to air transfer grilles intended for installation in building components (typically walls, floors or ceilings). The orientation of the installation of the air transfer grille can be vertical or horizontal.
The closing mechanism of the air transfer grille can come from expansion of material and/or from any mechanical or electrical closing device.
This document is applicable to fire resistant or fire resistant and smoke control air transfer grilles.
An additional test configuration is valid for fire resistant or fire resistant and smoke control air transfer grilles in applications where flame impingement is a risk during open state from start of fire (see Annex A).
This document evaluates the behaviour of the air transfer grille when exposed to the heating curve described in EN 1363 1 and the standard pressure described in EN 1363 1. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes under fire conditions. Such phenomena are only noted in describing the general behaviour of test specimens during the test.
The determination of the rate of leakage of smoke at ambient temperature or at 200 °C as an optional requirement for ATG with declared smoke control is specified in EN 1634 3.
This document is not applicable to the determination of the fire resistance of air transfer grilles that are used in ducts because ATG are considered as separating elements. The test method for ATG used in ducts is described in the corresponding duct standards.
This document is not applicable to the determination of the fire resistance of a fire damper or a fire barrier connected to a duct one or both sides, as an ATG is tested as a fire-separating element on its own. Fire dampers are tested according to EN 1366 2. Non-mechanical fire barriers are tested according to EN 1366 12.
This document is not applicable to the determination of the fire resistance of air transfer grilles in fire doors, shutters and openable windows as specified in EN 1634 1 and EN 1364 2, because the deformation of fire doors, shutters and openable windows in fire conditions differs from the deformation of flexible/rigid walls. Moreover, the location of thermocouples in the door standard is too specific to be handled in this document.
All values given in this document are nominal unless otherwise specified.

  • Draft
    27 pages
    English language
    e-Library read for
    1 day

This document specifies characteristics of solid wood panelling and cladding without tongue and groove machined from softwoods (wood of trees of the botanical group gymnosperms). Products are intended for interior or exterior use.
This document covers treated, untreated and surface treated products, including those made of thermally and chemically modified wood, as well as finger jointed products.
This document does not cover processes for treatment, surface coating or modification.
NOTE   Where further regulatory provisions (e.g. durability, reaction to fire, dangerous substances and generally CE-marking according to CPR) are required, EN 14915 applies.

  • Draft
    14 pages
    English language
    e-Library read for
    1 day

ISO/IEC 30188:2026 specifies a general reference architecture for a digital twin system in terms of defining system fundamentals through the use of architecture views.

  • Standard
    35 pages
    English language
    sale 15% off

IEC 60794-1-136:2026 specifies procedures to determine the maximum allowable push force applied on cables during the installation by blowing. Currently this parameter is determined by a separate test on the cable before installation. The methods specified in this document apply primarily to low-diameter cables (microduct cables according to IEC 60794-5) without rigid strength elements (e.g. GRP rods).

  • Standard
    15 pages
    English language
    e-Library read for
    1 day

This document specifies general requirements, such as ergonomic aspects in relation to ventilation of the kitchen (temperature, air aspects, moisture, noise, etc.), including a method for calculating the airflow rates.
This document is applicable to ventilation systems in commercial kitchens, associated areas and other installations processing foodstuffs intended for commercial use. Kitchens and associated areas are special rooms in which meals are prepared, where tableware and equipment is washed, cleaned and food is stored.
This document does not apply to kitchen ventilation systems in domestic kitchens.
This document does not apply to solid fuel appliances e.g. charcoal grills.
Unless otherwise specified, the requirements of this document are intended to be checked by way of inspection and/or measurement.
NOTE   Attention is drawn to the possible existence of additional or alternative national regulations on installation, appliance requirements and inspection, maintenance, operation.

  • Draft
    35 pages
    English language
    e-Library read for
    1 day