The present document specifies the technical requirements, limits and test methods for material sensing devices using UWB technology exterior material sensing devices for ground based vehicles below 10,6 GHz. The present document only covers non-contact based UWB material sensing devices with antenna connectors according to ECC/DEC(07)01 [i.1] and Commission Implementing Decision (EU) 2024/1467 [i.2]. Further details of the covered EUT for external material sensing applications for ground-based vehicles and the related categories can be found in clause 4.2 of the present document.
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.

  • Standard
    49 pages
    English language
    sale 15% off
  • Standard
    49 pages
    English language
    sale 15% off
  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60684-2:2025 gives methods of test for flexible insulating sleeving, including heat-shrinkable sleeving, intended primarily for insulating electrical conductors and connections of electrical apparatus, although they can be used for other purposes. The tests specified are designed to control the quality of the sleeving but it is recognized that they do not completely establish the suitability of sleeving for impregnation or encapsulation processes or for other specialized applications. Where necessary, the test methods in this document will be supplemented by appropriate impregnation or compatibility tests to suit the individual circumstances. This fourth edition cancels and replaces the third edition published in 2011.This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) major update of normative references;
b) revision of Clause 5, with amendment of methods for measurements of bore and wall thickness;
c) revision of Clause 11, to clarify that the longitudinal change test is done on expanded sleeving;
d) revision of Clause 28, additional method D for flame propagation testing;
e) revision of Clause 56, additional method for preparation of samples for adhesive peel test;
f) addition of Clause 63, abrasion test method;
g) addition of Clause 64, volume resistivity for semi-conducting materials;
h) addition of Clause 65, outgassing;
i) addition of Clause 66, resistance to weathering.

  • Standard
    104 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document applies to Digital Fixed Radio Systems (DFRS) in point-to-point operation with integral and external antennas in the frequency range of 1 GHz to 86 GHz corresponding to the appropriate frequency bands 1,4 GHz to 86 GHz as described in ETSI EN 302 217-2 [16], annex B to annex L. The present document summarizes:
• all characteristics, principles and, of utmost importance, terms and definitions that are common to all P-P equipment and antennas and its consultation is necessary when using all other parts of ETSI EN 302 217 series;
• all system-dependent requirements for Point-to-Point (P-P) equipment. These requirements are introduced in two different clauses sub-sets:
- Main requirements are requirements that are also related to the "essential requirements" under article 3.2 of Directive 2014/53/EU [i.1] and further detailed in the Harmonised Standard ETSI EN 302 217-2 [16].
- Complementary requirements are requirements that are not related to essential requirements under article 3.2 of Directive 2014/53/EU [i.1]. Nevertheless they have been commonly agreed for proper system operation and deployment when specific deployment conditions or compatibility requirements are present. Compliance to all or some of these requirements is left to manufacturer decision.
Health and safety requirements and EMC conditions and requirements (articles 3.1a and 3.1b of Directive 2014/53/EU [i.1]), as well as other special conditions and requirements (articles 3.3(a) to 3.3(i) of Directive 2014/53/EU [i.1]) are not considered in the ETSI EN 302 217 series.

  • Standard
    79 pages
    English language
    sale 15% off
  • Standard
    80 pages
    English language
    sale 15% off
  • Standard
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63378-3:2025 specifies the thermal circuit network model of discrete (TO‑243, TO‑252 and TO‑263) packages, which is used in the transient analysis of electronic devices to estimate precise junction temperatures without experimental verification.
This model is intended to be made and provided by semiconductor suppliers and to be used by assembly makers of electronic devices.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document specifies technical characteristics, limits and methods of measurements for Ultra Short Range Communication (USRC) equipment operating in the 57 GHz to 64 GHz frequency range. Further details for the covered Ultra Short Range Communication (USRC) equipment can be found in clause 4.2 of the present document.
NOTE: The relationship between the present document and essential requirement of article 3.2 of Directive 2014/53/EU [i.4] is given in Annex A.

  • Standard
    35 pages
    English language
    sale 15% off
  • Standard
    35 pages
    English language
    sale 15% off
  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60793-2-50:2025 is applicable to optical fibre categories B-652, B-653, B-654, B-655, B‑656 and B-657. A map illustrating the connection of IEC designations to ITU-T designations is shown in Table 1. These fibres are used or can be incorporated in information transmission equipment and optical fibre cables. Three types of requirements apply to these fibres:
- general requirements, as defined in IEC 60793-2;
- specific requirements common to the class B single-mode fibres covered in this document and which are given in Clause 4;
- particular requirements applicable to individual fibre categories or specific applications, which are defined in Annex A to Annex F.
For some fibre categories (shown in the relevant family specifications), there are sub-categories that are distinguished on the basis of difference in transmission attribute specifications. The designations for these sub-categories are documented in the individual family specifications. Table 1 shows a map from the IEC designations to the ITU-T recommendations.
This seventh edition cancels and replaces the sixth edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) The addition of a 200 µm coating nominal outer diameter option for B-654A, B, C fibres in Annex C

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61300-3-46:2025 provides a standard for the measurement of guide pin bore and fibre bore diameters for rectangular ferrules used in connectors specified in the IEC 61754 series. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of fibre bore measurement;
b) addition of force gauge method;
c) addition of Annex A on temperature dependence.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines the standard mechanical interface dimensions for the type of SAC family of connectors.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-1-9:2025 specifies test methods for the safety wire hole pull-out of RF connectors.
This document is applicable to the connectors with safety wire holes.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document defines multiple profiles for PAdES digital signatures which are digital signatures embedded within a PDF file.
The present document contains a profile for the use of PDF signatures, as described in ISO 32000-2 [1] and based on CMS digital signatures [i.6], that enables greater interoperability for PDF signatures by providing additional restrictions beyond those of ISO 32000-2 [1]. This first profile is not related to ETSI EN 319 142-1 [4].
The present document also contains a second set of profiles that extend the scope of the profile in ETSI EN 319 142-1 [4], while keeping some features that enhance interoperability of PAdES signatures. These profiles define three levels of PAdES extended signatures addressing incremental requirements to maintain the validity of the
signatures over the long term, in a way that a certain level always addresses all the requirements addressed at levels that are below it. These PAdES extended signatures offer a higher degree of optionality than the PAdES baseline signatures specified in ETSI EN 319 142-1 [4]. The present document also defines a third profile for usage of an arbitrary XML document signed with XAdES signatures that is embedded within a PDF file. The profiles defined in the present document provide equivalent requirements to profiles found in ETSI TS 102 778 [i.10]. Procedures for creation, augmentation, and validation of PAdES digital signatures are out of scope and specified in ETSI EN 319 102-1 [i.11]. Guidance on creation, augmentation and validation of PAdES digital signatures including the usage of the different attributes is provided in ETSI TR 119 100 [i.9]. The present document does not repeat the base requirements of the referenced standards, but instead aims to maximize interoperability of digital signatures in various business areas.

  • Standard
    32 pages
    English language
    sale 15% off
  • Standard
    32 pages
    English language
    sale 15% off
  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for Guarantees of Origin of electricity from all energy sources and of gaseous
hydrocarbons, Hydrogen, and heating & cooling.
This standard will establish the relevant terminology and definitions, requirements for registration, issuing, transferring and
cancellation in line with the RED and Cogeneration.
This standard will specify how to create accounts and associated ownership rights.
This standard will also cover measuring methods and auditing procedures.
These Guarantees of Origin may be traded and/or used for Disclosure/Labelling.
This standard is suitable for certification purposes.
This standard will specify the requirements on the issuing bodies and on the auditing bodies.

  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document applies to monitoring and control of Infrastructure Environment i.e. power, cooling and building environment systems for telecommunication centres and access network locations; also, the monitoring of energy and environmental parameters: Power Energy Environmental (PEE) parameters for ICT equipment in telecommunications sites or datacenter or customer premises are considered. Interoperability of heterogeneous management interfaces and systems with multi-vendor equipment is the key issue. The present document gives a general approach from equipment to management system. The multi-part deliverable is composed of a generic core part (the present document) and several specific parts for equipment category.
The present document defines:
• The site equipment maps and its division in functional subsets e.g. DC system which introduces following parts of this multi-part deliverable.
• The generic set of exchanged information required at the interface of equipment, which is instanced for each equipment covered by following parts of this multi-part deliverable.
• The minimum requirement for network architecture allowing some compatibility with old existing interface and the mechanism to exchange data between network elements.
• The data interface protocol for remote or local site management (Machine to Machine Interface MMI) and Human Machine Interface HMI for monitoring and controlling.
• Recommendations for a management network such as dependability, data back-up, data coherence and synchronization all along the management network, response time, fault detection and partial service in case of failure.
• The Measurement accuracy of Power, Energy and Environmental Parameters (PEE).

  • Standard
    90 pages
    English language
    sale 15% off
  • Standard
    90 pages
    English language
    sale 15% off
  • Standardization document
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61847:2025 specifies:
– the essential non-thermal output characteristics of ultrasonic surgical units;
– methods of measurement of these output characteristics;
– those characteristics to be declared by the manufacturers of such equipment.
This document is applicable to equipment which meets the criteria of a), b) and c) below:
a) ultrasonic surgical systems operating in the frequency range 20 kHz to 120 kHz; and
b) ultrasonic surgical systems whose use is the fragmentation, emulsification, debridement, or cutting of human tissue, whether or not those effects are delivered in conjunction with tissue removal or coagulation; and
c) ultrasonic surgical systems in which an acoustic wave is conducted by means of a specifically designed wave guide to deliver energy to the surgical site.
This document is not applicable to:
– lithotripsy equipment which uses extracorporeally induced pressure pulses, focused through liquid conducting media and the soft tissues of the body;
– surgical systems used as part of the therapeutic process (hyperthermia systems);
– surgical systems whose mechanism of action is through frictional heat generated by tissue in contact with the wave guide, e.g. clamp coagulators or clamping vibrational cutters;
– surgical systems whose mechanism of action is through focused ultrasound for either thermal degradation (high intensity focused ultrasound – HIFU or HITU) or cavitation erosion (Histotripsy) of tissue remote from the ultrasound transducer;
– surgical systems whose mechanism of action is through erosion of hard tissues in contact with the applicator tip, e.g. bone cutting or drilling.
This document does not deal with the effectiveness or safety of ultrasonic surgical systems. This document does not deal with airborne noise from the systems, which can affect operators and patients.
IEC 61847:2025 cancels and replaces the first edition published in 1998. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The upper frequency covered by this document has been raised from 60 kHz to 120 kHz.
b) The hydrophone method of measuring ultrasound power is now normative. Because of difficulties in using the calorimetry method of measuring ultrasound power, it is no longer the primary approach.
c) It is recognised that some systems can have more than one mode of vibration under user control, and the measurement techniques and declarations have been updated to address this.
d) The high-frequency component, which relates to cavitation developed at the applicator tip and the vibration amplitude at which cavitation occurs is addressed.
e) Specific requirements for measurement at excursion levels where no cavitation is present, and extrapolation to maximum excursion level(s) are described.
f) Guidance is provided to adapt the methodology described to more complex designs and vibration patterns, excursion directions, and their output characteristics.
g) Guidance is provided with respect to measurement tank arrangements for different types of systems.
h) The list of ultrasound methods and systems not covered by this document was extended to incorporate recent developments.
i) Definitions for cavitation related terms were added.
j) Requirements for the measurement of directivity characteristics of the applicator tip were changed.
k) Annex A was modified and Figure A.1 wa

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers internal arc-fault control devices, hereinafter referred to as IACD, which
are intended to:
- detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by
processing (at a minimum) the optical effect of an internal arc-fault, and
- operate mitigation device (either external or combined)
in order to minimize the effects of the internal arc-fault (see Figure 1).
For the purpose of this document the terms "light" or "optical" covers more than visible spectra.
They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see
Annex D).
For combined-type IACD, this document is considered in addition to the relevant product
standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance
to the relevant product standard is mandatory and cannot be claimed by testing to this document
alone.
NOTE 1 Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series.
[Figure 1]
Therefore, this document covers the following:
- internal arc-fault control device (stand-alone, multifunction or combined);
- one or more associated sensor(s) used to detect optical effect of the internal arc-fault;
- sensor(s), sensing another physical effect, to confirm the fault;
- associated or combined mitigation device.
An IACD is not intended to trigger under normal operation of low-voltage switchgear and
controlgear (i.e. absence of internal arc-fault), including normal arcing associated with
operation of disconnecting and switching devices.
This document only covers the following methods:
- optical detection of the light caused by an internal arc-fault;
- optional confirmation of internal arc-fault by line current measurement.
Many different conductive materials could be used in LV assemblies (e.g. steel, copper,
aluminium). Nevertheless, tests specified in this document are deemed to represent the most
critical and challenging conditions for arc-detection and cover all combinations of conductive
materials.
NOTE 2 Compared to other materials (e.g. steel, aluminium), copper leads to a lower optical radiation energy.
The rated voltage of the assembly in which an IACD is installed does not exceed 1 000 V AC.
Such devices are designed to be operated and maintained by skilled persons only.
This document does not cover:
- DC internal arc-fault detection and control;
- overcurrent relays;
- AFDD (arc-fault detection devices) as defined by IEC 62606;
- guidance on installation within assemblies;
NOTE 3 The integration of an IACD into an assembly is described in IEC TS 63107.
- use with additional measures needed for installation and operation within explosive
atmospheres. These are given in IEC 60079 series documents;
- requirements for embedded software and firmware design rules; for this subject, the
manufacturer is responsible for taking additional safety measures;
NOTE 4 IEC TR 63201 describes rules for firmware and embedded software development preventing errors in
software.
- cybersecurity aspects; for this subject, the manufacturer is responsible for taking additional
safety measures;
NOTE 5 See IEC TS 63208.
- mobile applications.
NOTE 6 Even when addressing internal arc-fault mitigation devices, this document does not supersede any other
relevant product standard (e.g. IEC 60947-2 or IEC 60947-9-1).
NOTE 7 DC arcing fault phenomena are under consideration. Further investigation is needed to comprehend DC
arcing phenomena and required sensing.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document details standardized procedures for conformance test of radio interface parameters for Point to Point (PP) equipment used for Digital Fixed Radio Systems (DFRS). Three sets of procedures (for ER, OR and CP) are considered in the scope of the present document:
• Procedures for radio parameters relevant to Essential Requirements (ER) and Optional Requirements (OR), relevant to article 3.2 of Directive 2014/53/EU [i.1]. Requirements for these parameters are detailed in ETSI EN 302 217-2 [9].
• Procedures for Complementary Requirements (CP) that, even if not considered "essential" in the light of article 3.2 of Directive 2014/53/EU [i.1], are considered important for the operations of PP equipment. These parameters are detailed in clause 8 of ETSI EN 302 217-1 [8].
The present document is mainly intended to be applied in conjunction with the above equipment relevant standards and will enable commonality of test results, irrespective of the body carrying out the test. However, the present document can be used also in conjunction with other DFRS relevant standards that would refer to the parameters and test methods hereby described. The conformance tests described in the present document are those related to radio specific parameters required directly by the radio equipment relevant standards at antenna ports in conducted test methods. Conformance tests to other boundary standards (e.g. those for system input/output interfaces (i.e. set at X/X' interface, shown in figure 2, and related baseband process) are outside the scope of the present document. Also, tests described in the present document are not applicable to radio equipment with integral antenna of undetachable antenna type requiring radiated test methods.

  • Standard
    58 pages
    English language
    sale 15% off
  • Standard
    58 pages
    English language
    sale 15% off
  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-7-1:2025 specifies requirements for terminal blocks and test disconnect terminal blocks according to Annex D with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to connect round copper conductors, with or without special preparation, having a cross-section between 0,05 mm2/30 AWG and 300 mm2/600 kcmil, intended to be used in circuits of a rated voltage not exceeding 1 000 V AC up to 1 000 Hz or 1 500 V DC. The tests on terminal blocks are made with AC or DC supply as required in relevant clauses of this document.
This fourth edition cancels and replaces the third edition published in 2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Scope extension for smaller conductor cross-sections;
b) Implementation of a contact pressure via insulation material (CoPI) test;
c) Introduction of new informative Annex E for larger cross-sections;
d) Reorganisation of all tables merged into two tables for electrical and mechanical values;
e) Implementation of AWG-sizes conductor types as an equivalent type of metric conductor with examples in Annex C;
f) Reorganisation of Annex D test disconnect terminal blocks to enhance readability;
g) Introduction of new informative Annex A for main characteristics of terminal blocks.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document specifies technical requirements, limits and test methods for Tank Level Probing Radar (TLPR) equipment operating in the frequency ranges 4,5 GHz to 7 GHz, 8,5 GHz to 10,6 GHz, 24,05 GHz to 27 GHz, 57 GHz to 64 GHz and 75 GHz to 85 GHz. Tank Level Probing Radar equipment in the scope of the present document consist of a combined transmitter and receiver and are equipped with an integral or dedicated antenna provided and specified by the equipment manufacturer. Further details of the covered TLPR equipment can be found in clause 4.2 of the present document. Technical and regulatory requirements for TLPR are provided in European Commission Implementing Decision (EU) 2025/105 [i.5].
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.1] is given in Annex A.

  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies 1-pair cabling and can be used in conjunction with all the space-specific standards of the EN 50173 series but especially EN 50173-3 and EN 50173-6.
NOTE   1-pair cabling for EN 50173-2, EN 50173-4 and EN 50173-5 is for further study.
It delivers 1-pair cabling specifications to extend generic cabling systems according to the EN 50173 series.
This document specifies the:
-   structure and minimum configuration for extension of generic cabling by 1-pair cabling;
-   interfaces at the service outlet (SO/TO);
-   performance requirements for cabling links and channels;
-   implementation requirements and options;
-   performance requirements for cabling components;
-   conformance requirements and verification procedures.
This document takes into account the requirements specified in application standards listed in Annex C.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines the HBES Information Model and a corresponding data exchange format for the Home and Building HBES Open Communication System.

  • Standard
    128 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides users with guidance that help manage risks related to energies & fluids during maintenance activities on items when in use. It is the responsibility of each employer, according to the terms commonly used in the company, to:
-   Set out the correlation between the processes described in this document and standard practices,
-   Define the roles and responsibilities of the people involved in the energies & fluids lockout process.
This document refers to concepts, definitions, rules, recommendations, and best practices taken from national and international documents (lockout/tagout - "administrative lockout" - Lockout/Tagout (LOTO) - Safe isolation) that cover activities to ensure the safety of workers with respect to energies & fluids.
This document deals with the prevention of energy & fluid (e.g. powders, gases, liquids, etc.) related risks; it is noted that some are covered by specific regulations or standards, such as the electrical risk. Environmental issues related to energies & fluids are not in the scope of this document. Danger associated with energies & fluids can be direct (e.g. contact, absorption, etc.) or indirect by reaction (e.g. mixing, heating, etc.). The scope includes all fluids because they can be intrinsically dangerous or become dangerous.
The recommendations given in this document have been drawn up with a view to ensure the safety and health of workers around hazardous energies & fluids, and situations when they are conducting actions related to maintenance, settings or changing formats, regardless of the type of activity.
The recommendations relate to activities carried out on items. They are applied before, during and after the operation to:
-   The energies & fluids supplied, contained, transported, or released by items, products,
-   Risks related to the presence of hazardous energies & fluids for the worker and the surrounding personal.
This document is a methodological guideline within the maintenance standards.
NOTE   Particular cases such as risks of lack of presence of vital elements for the worker (e.g. breathable air) are in the scope but will not be detailed.

  • Standard
    98 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document is based upon benchmark for server Energy Efficiency (EE) tool for general and heterogeneous servers [i.6].
The present document specifies:
1) test conditions and product configuration for the assessment of EE of heterogeneous servers using reliable, accurate and reproducible measurement methods;
2) an EE metric to support procurement requirements;
3) requirements for equipment to perform the measurements and analysis;
4) requirements for the measurement process;
5) requirements for the management of the EE metric calculation;
6) operation or run rules to configure, execute, and monitor the testing;
7) documentation and reporting requirements.
The metrics and methods apply to heterogeneous servers with various configurations, including type and count of APAs, CPU, memory, storage and any other add-on hardware expected to be present when deployed.
NOTE: Products whose feature set and intended operation are not addressed by active mode testing parameters are excluded from this evaluation method.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    24 pages
    English language
    sale 15% off
  • Standardization document
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the safety requirements for the design of must and grape harvest pumps and the means for verifying these requirements and gives information for the safe use of the machines covered.
This document applies to must and grape harvest pumps, as defined in 3.1, intended for the transfer of fresh, de-stemmed grapes and pomace.
This document deals with all significant hazards, hazardous situations or hazardous events relevant to grape harvest pumps, when it is used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer, specified in Annex B.
This document does not deal with hazardous phenomena associated with the integration of grape harvest pumps with other machinery.
This document does not give additional requirements for operations subject to special rules (e.g. explosive atmosphere, power supply from electrical networks where the voltage, frequency and tolerance differ from those of the public network).
This document is not applicable to:
-   adaptations intended for other fruit harvests;
-   pumps for building materials (covered by EN 12001 [1]);
-   pumps on grape harvesters;
-   reception conquests;
-   machines upstream or downstream of the pump.
This document is not applicable to grape harvest pumps manufactured before the date of its publication.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the manual methods used for obtaining samples of liquid or semi-liquid hydrocarbons, tank residues and deposits from fixed tanks, railcars, road vehicles, ships and barges, drums and cans, or from liquids being pumped in pipelines.
It applies to the sampling of liquid products, including crude oils, intermediate products, synthetic hydrocarbons and bio fuels, which are stored at or near atmospheric pressure, or transferred by pipelines as liquids at elevated pressures and temperatures.
The sampling procedures specified are not intended for the sampling of special petroleum products which are the subject of other International Standards, such as electrical insulating oils (covered in IEC 60475), liquefied petroleum gases (covered in ISO 4257), liquefied natural gases (covered in ISO 8943) and gaseous natural gases (covered in ISO 10715).
This document refers to methods of sampling and sampling equipment in use at the time of writing. It does not exclude the use of new equipment, provided that such equipment enables samples to be obtained according to the requirements and procedures of this document.

  • Standard
    79 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and their test methods for elastomeric impression and bite registration materials.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a real-time PCR procedure for the quantitation of the amount of roe deer DNA relative to total mammalian DNA in meat and meat products.
Results of this roe deer assay are expressed in terms of roe deer (Capreolus capreolus) haploid genome copy numbers relative to total mammalian haploid genome copy numbers. The content of roe deer can also be expressed as mass fraction in % using gravimetrically prepared calibration material from meat mixtures or model samples.
The method has been previously validated in a collaborative study and applied to DNA extracted from samples that consist of raw roe deer meat in a raw pig meat background as well as raw and boiled sausages.
The limit of detection of the roe deer PCR has been determined experimentally to be at least 5 target gene copies or at least 0,1 % roe deer.
The compliance assessment process is not part of this document.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies polymers commonly used in manufacturing dental instruments.
It is applicable to polymers used to manufacture either an entire instrument or part of an instrument.
It is applicable to single-use and reusable dental instruments, whether they are connected to a power-driven system or not.
This document does not apply to oral appliances and devices (e.g. splints, mouthpieces, crowns, bridges, implants), to instruments used long-term in the mouth of the patient or to devices and instruments not made of polymers.
This document contains a selection of polymers suitable for use in the manufacture of dental instruments.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to passenger body side entrance systems of all newly designed railway vehicles such as tram, metro, suburban, main-line and high-speed trains that carry passengers. The requirements of this document also apply to existing vehicles undergoing refurbishment of the door equipment, as far as it is reasonably practicable.
This document also specifies the requirements for testing of entrance systems.
This document makes reference to manual and power operated entrance systems. For manual doors, clauses referring to power operation are not applicable.
This document does not apply to the following:
-   Entrance systems for equipment access, inspection or maintenance purposes and for crew only use;
-   Doors on freight wagons; and
-   Doors or hatches specifically provided for escape under emergency conditions.
Where passenger bodyside entrance doors are to be used for staff access, EN 16116-1:2022, EN 16186-4:2019 and EN 16186-8:2022+A1:2024 provide the details for the staff access requirements.

  • Standard
    91 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the function, design, performance and testing of brake indicators. It applies to brake indicators visible from the outside of the rail vehicle.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements and their test methods for dusters for applying formulated products in the form of dust with regard to minimizing the potential risk of environmental contamination during use.
Hand operated portable dusters (knapsack) are not included in this document.
This document deals with all the significant environmental hazards related to the duster, namely:
-   hazards due to involuntary or unnecessary application of PPP;
-   hazards due to point pollution;
-   hazards due to losses to other areas than the target;
-   hazards due to maintenance, servicing and cleaning operations;
-   hazards due to inspections, such as unavailability of means to connect measuring instruments.
This document does not deal with safety requirements for protection of the operator only.
NOTE   General safety requirements to protect the operator are covered by EN ISO 4254-1.
This document is not applicable to dusters manufactured before the date of its publication.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements to meet by measuring systems fitted on track geometry measuring trolleys and manually operated devices to give an evaluation of track geometry quality when using one or more of the parameters described in EN 13848 1. It sets out the acceptable differences from EN 13848 1 when using track geometry measuring trolleys and manually operated devices to measure track geometry.
It applies to all track geometry measuring systems fitted to track geometry measuring trolleys and manually operated devices after the date of implementation of this document.
In the case of lightweight devices working at a speed higher than walking speed, or in the case of track geometry measuring systems installed on track recording cars but not measuring in loaded conditions as defined in EN 13848 1, the test procedure defined in EN 13848 2 is applicable.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies laboratory test methods, test requirements and classifications for the casings of non-residential air handling units (AHU). For the leakage tests, a method for on-site testing is also included.
The test methods and requirements are applicable to both model boxes and real units, except for the thermal and acoustic performance of the casing.
The test method for the thermal performance of the casing is applicable to the comparison of different casing constructions, but not for the calculation of thermal losses through casing or the risk of condensation.
The test method for the acoustic performance of the casing is applicable for the comparison of different constructions, but not for the provision of accurate acoustic data for specific units.
This document is not applicable for fan-coil units and similar products.
The filter bypass test specified in this document is not applicable to high efficiency particulate air (HEPA) filter installations.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for determining the extension set of leather. It is intended for use on upholstery leather but is applicable to all flexible leathers.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the minimum requirements for billing of all consumption-based utility
network services to domestic customers. It covers the processes required to produce the bill and to deal with
issues that arise after the bill has been sent, as well as the content of the billing document or statement. This
International Standard is applicable to utility network services that are unmetered, metered at the point of
delivery or metered remotely (e.g. on the supplier's own premises), and it covers any unmetered or unmeasured
charges appearing on the same bill as metered or measured charges, as well as flat rate charges.
NOTE 1 Utility network services include electricity supply, water, sanitation, gas supply, district heating and
communications.
NOTE 2 The requirements given in this International Standard are also applicable to other consumers who are legally
entitled to use the service provided by the supplier, except where in order to comply with privacy or data protection
requirements, it is necessary for the supplier to obtain the authority of the registered customer before dealing with another
consumer on billing matters.
This International Standard does not cover pricing, except for a requirement to provide information to
customers. It is only applicable to billing for consumption-based utility network services and it applies to all bills
or statements for utility network services where there is an ongoing account relationship between the customer
and the supplier, regardless of the payment method used.
NOTE 3 This includes bills for metered consumption, bills where a formula is used to estimate consumption (e.g. water
bills based on the number of persons per household or the size of the house), or where a flat rate fee is charged regardless
of consumption (e.g. telephony or internet bills where the tariff allows unlimited usage). It also applies to prepayment
customers, where a bill or account from the supplier is necessary to enable the customer to reconcile the amount paid
in advance with the cost of consumption, or where the customer expects to receive a bill based on point of sale or other
advertising (e.g. mobile telephony and energy metering) where codes, keys, electronic dongles or electronic cards are
used to load and reload the service and to indicate what was purchased.
NOTE 4 Services that are not billed [e.g. mobile telephony paid for by pre-purchased SIM (Subscriber Identity Module)
cards that are unmetered] and services that are funded directly by the taxpayer without bills being issued are not covered
by this International Standard.
NOTE 5 Many of the key principles in this International Standard also apply to all forms of billing, and suppliers are
therefore encouraged to adopt the relevant requirements in this International Standard for billing of other services.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English language
    sale 15% off

IEC 63522-16:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for resistance to soldering heat and solderability for standard soldering processes.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and recommendations for the transportation of CO2 streams from the capture site to the storage facility where it is primarily stored in a geological formation or used for other purposes (e.g. for enhanced oil recovery or CO2 use).
This document applies to the transportation of CO2 streams by
—     rigid metallic pipelines,
—     pipeline systems,
—     onshore and offshore pipelines for the transportation of CO2 streams,
—     conversion of existing pipelines for the transportation of CO2 streams, and
—     transportation of CO2 streams in the gaseous and dense phases.
This document also includes aspects of CO2 stream quality assurance, as well as converging CO2 streams from different sources.
Health, safety and environment aspects specific to CO2 transport and monitoring are also considered in this document.
Transportation of CO2 via ship, rail or on road is not covered in this document.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

RTS/LI-00276-3

  • Standard
    62 pages
    English language
    sale 15% off
  • Technical specification
    62 pages
    English language
    sale 10% off
    e-Library read for
    1 day

RTS/LI-00277

  • Standard
    105 pages
    English language
    sale 15% off
  • Technical specification
    105 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to determine the susceptibility of textile floor coverings to mechanical damage at cut edges.
It is applicable to textile floor coverings both as broadloom materials and as tiles and planks.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62232:2025 provides methods for the determination of RF field strength, power density and specific absorption rate (SAR) in the vicinity of base stations (BS) for the purpose of evaluating human exposure.
This document:
a) considers intentionally radiating BS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 300 GHz;
b) considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;
c) specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely:
1) product compliance – determination of compliance boundary information for a BS product before it is placed on the market;
2) product installation compliance – determination of the total RF exposure levels in accessible areas from a BS product and other relevant sources before the product is put into operation;
3) in-situ RF exposure assessment – measurement of in-situ RF exposure levels in the vicinity of a BS installation after the product has been taken into operation;
d) specifies how to perform RF exposure assessment based on the actual maximum approach;
e) describes several RF field strength, power density, and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed BS and laboratory-based evaluations;
f) describes how surveyors establish their specific evaluation procedures appropriate for their evaluation purpose;
g) provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value;
h) provides methods for the RF exposure assessment of BS using time-varying beam-steering technologies such as new radio (NR) BS using massive multiple input multiple output (MIMO).
NOTE 1 Practical implementation case studies are provided as examples in the companion Technical Report IEC TR 62669 [5].
NOTE 2 Although the current BS product types have been specified to operate up to 200 GHz (see, for example, [6] and [7]), the upper frequency of 300 GHz is consistent with applicable exposure limits.
NOTE 3 The lower frequency considered for ambient sources, 100 kHz, is derived from ICNIRP-1998 [2] and ICNIRP-2020 [1]. However, some applicable exposure guidelines require ambient fields to be evaluated as low as 3 kHz, e.g. Safety Code 6 [4] and IEEE Std C95.1-2019 [3].
NOTE 4 Specification of appropriate RF exposure mitigation measures such as signage, access control, and training are beyond the scope of this document. It is possible to refer to the applicable regulations or recommended practices on these topics.
NOTE 5 While this document is based on the current international consensus about the best engineering practice for assessing the compliance of RF exposure with the applicable exposure limits, it is possible that national regulatory agencies specify different requirements. The entity conducting an RF exposure assessment needs to be aware of the applicable regulations.
This fourth edition cancels and replaces the third edition published in 2022. It includes corrections of obvious errors and text improvements on the third edition in order to bring more clarity in the description of the assessment methods and avoid misinterpretations. This edition has the same technical content as the third edition.

  • Standard
    349 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-28:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for thermoelectric electromotive force (e.m.f.).

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-27:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for electrical contact noise.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

RTS/LI-00276-1

  • Standard
    64 pages
    English language
    sale 15% off
  • Technical specification
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-37:2025 This part of lEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. The object of this document is to define a standard test method to measure terminal temperature rise at rated load, included solder terminals, flat quick-connect terminations, screw and screwless type terminals, alternative termination types and sockets.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-49:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for long term stability of sealing.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60060-2:2025 is applicable to complete measuring systems and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages and combined and composite voltages as specified in IEC 60060-1. For measurements during on-site tests, see IEC 60060-3. The limits on uncertainties of measurements stated in this document apply to test levels stated in IEC 60071-1. The principles of this document apply also to higher levels but the uncertainty can be greater.
This document:
• defines the terms used;
• describes methods to estimate the uncertainties of high-voltage measurements;
• states the requirements that apply to measuring systems;
• describes the methods for approving a measuring system and checking its components;
• describes the procedures by which the user demonstrates that a measuring system meets the requirements of this document, including the limits set for the uncertainty of measurement.
This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The general layout and text has been updated and improved to make the standard easier to use.
b) This document has been revised to align it with the fourth edition of IEC 60060-1.
c) The treatment of measurement uncertainty estimation has been expanded.
d) This document is now applicable to measuring systems used in testing at all standard insulation levels specified in IEC 60071-1.
e) The measurement uncertainty requirement for the front time of the standard lighting impulse voltage has been changed from 10 % to 15 %, for testing at all standard insulation levels specified in IEC 60071-1.
f) The parameter "time-to-peak" of the switching impulse defined in the third edition of IEC 60060-1:2010 has been replaced by "front time" in the fourth edition of IEC 60060-1. Necessary changes have been made in this document to accommodate this change in IEC 60060-1.
g) Clause 10, Measurement of combined voltages and Clause 11, Measurement of composite voltages have been added.
h) Clause B.1 has been significantly revised to align more closely with the provisions of Clause 5, including using the same nomenclature.

  • Standard
    91 pages
    English language
    sale 10% off
    e-Library read for
    1 day