This document specifies three methods for the determination of the density of non-cellular plastics in the form of void-free moulded or extruded objects, as well as powders, flakes and granules.
—     Method A: Immersion method, for solid plastics (except for powders) in void-free form.
—     Method B: Liquid pycnometer method, for particles, powders, flakes, granules or small pieces of finished parts.
—     Method C: Titration method, for plastics in any void-free form.
NOTE            Density is frequently used to follow variations in physical structure or composition of plastic materials. Density can also be useful in assessing the uniformity of samples or specimens. Often, the density of plastic materials depend upon the choice of specimen preparation method. When this is the case, precise details of the specimen preparation method are intended to be included in the appropriate material specification. This note is applicable to all three methods.
Annex C provides further information for calculating the volume of the specimen used for the determination of the density in the case that method A (the immersion method) is applied.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document defines the characteristics and requirements of antennas for point-to-point radio equipment operating in the frequency range from 1 GHz to 174,8 GHz falling within the scope (see note) of ETSI EN 302 217-2 [i.2].
For technical commonalities that range is here divided into sub-ranges as follows:
Range 0: 1 GHz to 3 GHz;
Range 1: 3 GHz to 14 GHz;
Range 2: 14 GHz to 20 GHz;
Range 3: 20 GHz to 24 GHz;
Range 4: 24 GHz to 30 GHz;
Range 5: 30 GHz to 47 GHz;
Range 6: 47 GHz to 71 GHz;
Range 7: 71 GHz to 86 GHz;
Range 8: 92 GHz to 114,25 GHz;
Range 9: 130 GHz to 174,8 GHz.
The present document is applicable to fixed radio equipment with integral (see note) or dedicated antennas.
NOTE: For information, ETSI EN 302 217-2 [i.2] includes in its scope only the use of detachable integral antennas; undetachable integral antennas are not considered due to the present lack of radiated test procedures for the radio equipment parameters.
The present document also applies to stand-alone antennas, placed separately on the market. In this case the present document is to be used by radio equipment manufacturers to provide guidance as to the information for the user, as required by article 10 paragraph 8 of Directive 2014/53/EU [i.1], regarding the antenna characteristics required so as the radio equipment, supplied without antenna, can operate as intended in its technical documentation. The present document is applicable to fixed beam antennas, as well as to "self-alignment tracking" antenna, with limited tracking range, so that all requirements in the present document are respected throughout the tracking angle indicated in the technical documentation. The main body of the present document specifies the characteristics that define the various antenna classes, whilst the annexes provide additional information that is useful to both antenna manufacturers and user/installers.

  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies an instrumental method for determining the turbidity of clear liquids. It is applicable to resins and resin solutions, solvents, clear coating materials, monomers and any other liquids where clarity is specified.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of the length, width and straightness of bitumen sheets for roof waterproofing.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62590-1:2025 specifies the common requirements and definitions for all power converter applications in fixed installations for power supply of railway systems.
This document applies to fixed installations of following electric traction systems:
railway networks,
metropolitan transport networks including metros, tramways, trolleybuses and fully automated transport systems, magnetic levitated transport systems, electric road systems.
This document applies to AC/DC converters, DC converters and AC converters. Converters for improvement of power quality and for energy saving are also included.
Converters connected to electric traction systems feeding 3AC, 1AC or DC systems for auxiliary purpose are not in the scope of this document but some aspects such as insulation coordination and railway specific conditions can be referred to.
This document, in conjunction with the other parts of IEC 62590, cancels and replaces IEC 62589:2010 and the former IEC 62590:2019.
This document includes the following significant technical changes with respect to IEC 62589:2010 and the former IEC 62590:2019:
a) Split into common requirements and special requirements for different converters;
b) Interface Model for the different systems connected;
c) Split into circuits with their requirements like insulation coordination;
d) Energy efficiency addressed.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The overload test ensures the stove's performance remains consistent even when the use deviates from the nominal test requirements, by assessing its ability to handle a higher load of fuel compared to the standard nominal fuel load which occurs during the use phase.
This document specifies a test method for an additional overload test for appliances as described in EN 16510-2-1:2022 and EN 16510-2-2:2022.
This test procedure covers testing in addition a higher heat output than nominal heat output as described in EN 16510-1:2022.

  • Technical specification
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of sealed (hermetic and semi-hermetic type) motor-compressors, their protection and control systems, if any, which are intended for use in equipment for household and similar purposes and which conform with the standards applicable to such equipment. It applies to motor-compressors tested separately, under the most severe conditions that may be expected to occur in normal use, their rated voltage being not more than 250 V for single-phase motor-compressors and 480 V for other motor-compressors

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for measuring the pH value of dispersions and coating materials using pH sensors with ion-sensitive field-effect transistor (ISFET) technology.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the technical requirements to minimize the hazards listed in Clause 4 which can arise during the commissioning, the operation and the maintenance of baggage and equipment tractors when used as intended, including misuse reasonably foreseeable by the manufacturer, when carried out in accordance with the specifications given by the manufacturer or his authorized representative. It also takes into account some requirements recognized as essential by authorities, aircraft and ground support equipment (GSE) manufacturers as well as airlines and handling agencies.
This document applies to self-propelled baggage and equipment tractors with driver accommodation.
This document does not apply to pedestrian controlled equipment.
This document deals with vibrations which are considered as significant. Vibration measurements are dealt with in EN 1915-3.
No extra requirements on noise are provided other than those given in EN 1915-4.
NOTE   EN 1915-4 provides the general GSE noise requirements.
This part of EN 12312 is not applicable to baggage and equipment tractors manufactured before the date of its publication.
This part of EN 12312 when used in conjunction with EN 1915-1, EN 1915-2, EN 1915-3 and EN 1915-4 provides the requirements for baggage and equipment tractors.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of prevailing torque (all metal) hexagon high nuts, in steel and stainless steel, with metric fine pitch thread 8 mm to 39 mm, and with product grades A and B.
NOTE            These nuts are designed with an overall height hmin = mmin (as specified in ISO 898-2 and ISO 8674 for style 2) plus the prevailing torque feature. hmax has been established in function of hmin; therefore, the tolerance (hmax – hmin) does not follow the ISO code system for tolerances (IT system). The wrenching height mw,min corresponds to the values specified for style 1.
If in certain cases other specifications are requested, property classes and stainless steel grades can be selected from ISO 898-2 or ISO 3506-2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the system layer of the coding. It was developed principally to support the combination of the video and audio coding methods defined in Parts 2 and 3 of ISO/IEC 13818. The system layer supports six basic functions: 1) the synchronization of multiple compressed streams on decoding; 2) the interleaving of multiple compressed streams into a single stream; 3) the initialization of buffering for decoding start up; 4) continuous buffer management; 5) time identification; 6) multiplexing and signalling of various components in a system stream. A Rec. ITU-T H.222.0 | ISO/IEC 13818-1 multiplexed bit stream is either a transport stream or a program stream. Both streams are constructed from PES packets and packets containing other necessary information. Both stream types support multiplexing of video and audio compressed streams from one program with a common time base. The transport stream additionally supports the multiplexing of video and audio compressed streams from multiple programs with independent time bases. For almost error-free environments the program stream is generally more appropriate, supporting software processing of program information. The transport stream is more suitable for use in environments where errors are likely. A Rec. ITU-T H.222.0 | ISO/IEC 13818-1 multiplexed bit stream, whether a transport stream or a program stream, is constructed in two layers: the outermost layer is the system layer, and the innermost is the compression layer. The system layer provides the functions necessary for using one or more compressed data streams in a system. The video and audio parts of this Specification define the compression coding layer for audio and video data. Coding of other types of data is not defined by this Specification, but is supported by the system layer provided that the other types of data adhere to the constraints defined in 2.7.

  • Standard
    324 pages
    English language
    sale 15% off
  • Draft
    324 pages
    English language
    sale 15% off

This document specifies the apparatus, materials, specimen preparation, procedures, results and reports for testing the corrosion test of steel bars. This document includes an evaluation method. This document applies to reinforced concrete structures exposed simultaneously to atmospheric, splash, tidal, immersion, and buried zones in marine environments. NOTE Annex A provides test apparatus examples. Annex B illustrates test results.

  • Technical specification
    22 pages
    English language
    sale 15% off
  • Draft
    22 pages
    English language
    sale 15% off
  • Draft
    22 pages
    English language
    sale 15% off
  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off
  • Draft
    14 pages
    English language
    sale 15% off
  • Draft
    14 pages
    English language
    sale 15% off
  • Draft
    16 pages
    French language
    sale 15% off

This document establishes the specification of the Basic image interchange format (BIIF). This document provides a foundation for interoperability in the interchange of imagery and imagery-related data among applications. It also provides a detailed description of the overall structure of the format, as well as specification of the valid data and format for all fields defined with BIIF. Annex C contains a Model Profile of BIIF in tables to assist in profile development. The scope and field of application of this document includes the capability to perpetuate a proven interchange capability in support of commercial and government imagery, Programmer’s Imaging Kernel System (PIKS) data, and other imagery technology domains in that priority order. This document provides a data format container for image, symbol, and text, along with a mechanism for including image-related support data. This document: — provides a means whereby diverse applications can share imagery and associated information; — allows an application to exchange comprehensive information to users with diverse needs or capabilities, allowing each user to select only those data items that correspond to their needs and capabilities; — minimizes preprocessing and postprocessing of data; — minimizes formatting overhead, particularly for those applications exchanging only a small amount of data and for bandwidth-limited systems; — provides a mechanism (Transportable File Structure, TFS) to interchange PIKS image and image-related objects; — provides extensibility to accommodate future data, including objects.

  • Standard
    143 pages
    English language
    sale 15% off
  • Draft
    145 pages
    English language
    sale 15% off
  • Draft
    145 pages
    English language
    sale 15% off

IEC 60749-34-1:2025 describes a test method that is used to determine the capability of power semiconductor modules to withstand thermal and mechanical stress resulting from cycling the power dissipation of the internal semiconductors and the internal connectors. It is based on IEC 60749-34, but is developed specifically for power semiconductor module products, including insulated-gate bipolar transistor (IGBT), metal-oxide-semiconductor field-effect transistor (MOSFET), diode and thyristor. If there is a customer request for an individual use or an application specific guideline (for example ECPE Guideline AQG 324), details of the test method can be based on these requirements if they deviate from the content of this document. This test caused wear-out and is considered destructive.

  • Draft
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Draft
    2 pages
    English language
    sale 15% off
  • Draft
    2 pages
    English language
    sale 15% off
  • Draft
    4 pages
    French language
    sale 15% off

This document specifies the requirements and characteristics of round and flat wire used for strengthening the bead of all kinds of tyres.

  • Standard
    15 pages
    English language
    sale 15% off
  • Draft
    15 pages
    English language
    sale 15% off
  • Draft
    15 pages
    English language
    sale 15% off

This document covers performance, marking requirements and test methods for a flexible sprinkler hose with fittings, attachments and anchoring components intended for direct connection to a single fire sprinkler in installations utilizing a flexible attachment to the sprinkler system piping such as clean rooms, suspended ceilings, and exhaust ducts.

  • Standard
    18 pages
    English language
    sale 15% off
  • Draft
    19 pages
    English language
    sale 15% off
  • Draft
    19 pages
    English language
    sale 15% off
  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off
  • Draft
    6 pages
    English language
    sale 15% off
  • Draft
    6 pages
    English language
    sale 15% off
  • Draft
    8 pages
    French language
    sale 15% off

This document specifies dimensions for heel guidings in large stamping and forming dies. It also gives example applications and an example for ordering.

  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    5 pages
    French language
    sale 15% off
  • Draft
    5 pages
    English language
    sale 15% off
  • Draft
    5 pages
    English language
    sale 15% off

This document specifies the two-step Toet method for the determination of the derived displacement of hydraulic fluid power positive displacement pumps and motors under steady-state conditions. A value for the derived displacement is determined from measurements at multiple shaft speeds.

  • Standard
    16 pages
    English language
    sale 15% off
  • Draft
    17 pages
    English language
    sale 15% off
  • Draft
    17 pages
    English language
    sale 15% off

This document specifies the requirements for sterilized, single-use, gravity feed infusion sets, used together with the volumetric infusion controllers of IEC 60601-2-24.

  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the separation of fatty acid methyl esters (FAME) from middle distillates by liquid chromatography (LC) and for the determination of the pattern of the fatty acid methyl esters by gas chromatography (GC) according to EN 14103.
This document is applicable for the determination of the pattern of the fatty acid methyl esters for the calculation of the average molecular mass of FAME according to EN 14078 [1].
Independently from the origin of the middle distillate, this method is applicable to FAME of vegetable or animal origin that contain fatty acid methyl esters between C6:0 and C24:1. The method is suitable for the separation and determination of FAME from middle distillates with FAME contents of at least 2 % (V/V).
NOTE   For the purpose of this document, the terms % (V/V) and % (m/m) are used to express volume fractions in % or mass fractions in %.

  • Draft
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Plastic waterproofing sheets generate plastic waste at different stages during their life cycle: production, construction process, service life and end-of-life.
This document specifies the source of recyclate made from pre-consumer material and post-consumer material as it is used in new products. These new products can be plastic waterproofing sheets, other sheets, other construction products or other products.
It defines terms and definitions.
It gives guidance for assessing the recyclates intended for use in the production of new products.
This document is applicable for similar products as construction sheets or membranes consisting of polymers or plastic components such as: swimming pool membranes, geosynthetic membranes, garden ponds membranes, protection membranes, accessories based on thermoplastic material such as walkways, prefabricated pieces. The listing is not exhaustive.
NOTE   The design for recycling of packaging, including the recycling itself, is defined in the CEN/TC 261 “Packaging”.

  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies an extensible markup language (XML) format to facilitate the transfer of dental case data and CAD/CAM data between software systems.

  • Draft
    76 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the dimensions of various endodontic obturating materials and the radiopacity for polymeric points, polymeric-coated thermoplastic obturating carriers, non-point-shaped thermoplastic obturating material, or combinations of the above used for obturation of a root canal system. It also specifies numerical and colour-coding systems for designating the sizes of preformed endodontic obturating points, a method for determining the melt mass-flow rate for injection material, and the requirements for marking, labelling, packaging and the instructions for use.
Dental endodontic obturating points are marketed as sterilized or non-sterilized. Sterility is not included in this document. Any claim that the product is sterile is the manufacturer's responsibility (see Table 3). This document does not apply to instruments or apparatus used with obturating materials that become plastic with heat or materials supporting a coronal restoration.
Clause 7 specifies marking, labelling and packaging, including the instructions for use. This document does not specify requirements or test methods for sterility. Reference to applicable national regulations, internationally accepted pharmacopoeia and standards for validating sterilization processes can apply.

  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements relating to the dimensional, mechanical and physical-chemical characteristics of thermoplastic barrier films designed for agricultural and horticultural soil disinfection by means of fumigation.
This document specifies also the test methods for verifying these requirements, except the method for determining film permeability using a static technique, which is specified in EN 17098 2.
This document defines the criteria for design for recycling of barrier films and refer to EN 18109 for the product lifecycle, including installation, use, removal and collection for end of life for management of the product after its usage.
This document is applicable to films used during soil disinfection by fumigation (class 1), and to films used during soil disinfection subsequently kept in situ as mulch films (class 2).
On the date of publication of this document, the barrier films are multi-layer films.

  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the procedure for classification of the resistance to fire performance of construction products and building elements used as components of building service installations, using data from fire resistance tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this document.
Construction products or building elements for use in ventilation systems include (excluding smoke control system):
—   fire resisting ventilation ducts;
—   fire dampers.
Construction products or building elements for use in or as cables systems:
—   unprotected electric cables with intrinsic fire resistance;
—   fire protective systems for cable systems and associated components.
Relevant test methods which have been prepared for these construction products/building elements are listed in Clause 2.
NOTE   Cables associated with fire dampers are not generally covered by this document unless there is a local regulation that requires it.

  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method used for the determination of the temperature of deflection under load of specified plastics (including fibre-reinforced plastics in which the fibre length is, prior to processing, greater than 7,5 mm) under defined conditions. A number of different test conditions are defined, depending on the anticipated specimen dimensions.
For additional information, see ISO 75-1:2020, Clause 1.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terms for the manufacture and use of gas cylinders and other pressure receptacles and their fittings.

  • Draft
    68 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60068‑2-88:2025 establishes test methods for the resistance of electronic and electromechanical components, unpopulated circuit boards and assemblies to liquid cleaning media and cleaning processes, which are agreed between user and supplier for applications, where cleaning is required. These tests are not applicable to components, unpopulated circuit boards and assemblies, which are not intended to be subjected to cleaning processes. Tests XD1 and XD2 primarily are intended for qualification testing of components and unpopulated circuit boards suitable for cleaning processes, but can be adopted as well to testing of material compatibility and specific cleaning media used in manufacturing processes of components and unpopulated circuit boards. Test XD3 is intended to determine the resistance of electronic assemblies suitable for cleaning processes to the various cleaning processes to which they are exposed during manufacturing, including the effects of assembly and soldering processes.

  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62074-1: 2025 applies to fibre optic wavelength division multiplexing (WDM) devices. These have all of the following general features: - they are passive, in that they contain no optoelectronic or other transducing elements; however they can use temperature control only to stabilize the device characteristics; they exclude any optical switching functions; - they have three or more ports for either the entry or exit of optical power, or both, and share optical power among these ports in a predetermined fashion depending on the wavelength; - the ports are optical fibres, or optical fibre connectors. This document establishes uniform requirements for the following: - optical, mechanical and environmental properties. This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) harmonization of terms and definitions with IEC TS 62627-09; b) simplified classification, documentation and standardization system in Clause 4, and moving interface style to Annex H.

  • Draft
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the protective provisions relating to electrical safety in fixed installations, when it is reasonably likely that hazardous voltages or currents will arise for people or equipment, as a result of the mutual interaction of AC and DC electric power supply traction systems. It also applies to all aspects of fixed installations that are necessary to ensure electrical safety during maintenance work within electric power supply traction systems. The mutual interaction can be of any of the following kinds: - parallel running of AC and DC electric traction power supply systems; - crossing of AC and DC electric traction power supply systems; - shared use of tracks, buildings or other structures; - system separation sections between AC and DC electric traction power supply systems. The scope is limited to galvanic, inductive and capacitive coupling of the fundamental frequency voltages and currents and their superposition. This document applies to all new lines, extensions and to all major revisions to existing lines for the following electric traction power supply systems: a) railways; b) guided mass transport systems such as: 1) tramways, 2) elevated and underground railways, 3) mountain railways, 4) magnetically levitated systems, which use a contact line system, 5) trolleybus systems, and 6) electric traction power supply systems for road vehicles, which use an overhead contact line system; c) material transportation systems. The document does not apply to: a) electric traction power supply systems in underground mines; b) cranes, transportable platforms and similar transportation equipment on rails, temporary structures (e.g. exhibition structures) in so far as these are not supplied directly or via transformers from the contact line system and are not endangered by the electric traction power supply system for railways; c) suspended cable cars; d) funicular railways; e) procedures or rules for maintenance. The rules given in this document can also be applied to mutual interaction with non-electrified tracks, if hazardous voltages or currents can arise from AC or DC electric traction power supply systems.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the protective provisions relating to electrical safety in fixed installations associated with AC and/or DC traction systems and to any installations that can be endangered by the electric traction power supply system. This also includes requirements applicable to vehicles on electrified lines. It also applies to all aspects of fixed installations which are necessary to ensure electrical safety during maintenance work within electric traction power supply systems. This document applies to new electric traction power supply systems and major revisions to electric traction power supply systems for: a) railways; b) guided mass transport systems such as 1) tramways, 2) elevated and underground railways, 3) mountain railways, 4) trolleybus systems, 5) electric traction power supply systems for road vehicles, which use an overhead contact line system, and 6) magnetically levitated systems, which use a contact line system; c) material transportation systems. This document does not apply to: a) electric traction power supply systems in underground mines, b) cranes, transportable platforms and similar transportation equipment on rails, temporary structures (e.g. exhibition structures) in so far as these are not supplied directly or via transformers from the contact line system and are not endangered by the electric traction power supply system, c) suspended cable cars, d) funicular railways, e) existing vehicles. This document does not specify working rules for maintenance. The requirements within this document related to protection against electric shock are applicable to persons only.

  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60974-4:2025 specifies test procedures for periodic inspection and, after repair, to ensure electrical safety. These test procedures are also applicable for maintenance. This document is applicable to power sources for arc welding and allied processes designed in accordance with IEC 60974-1 or IEC 60974-6. Stand-alone ancillary equipment designed in accordance with other parts of IEC 60974 can be tested in accordance with relevant requirements of this part of IEC 60974. This document includes requirements for battery-powered arc welding power sources, which are given in Annex D. NOTE 1 The welding power source can be tested with any ancillary equipment fitted that can affect the test results. This document is not applicable to testing of new power sources or engine-driven power sources. NOTE 2 For a power source not built in accordance with IEC 60974-1, see Annex C. This fourth edition cancels and replaces the third edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - examples for the measurements in respect of EN 50699, - consideration of measuring equipment in respect of IEC 61557 series, - more determinations of no-load voltage for welding equipment built according to IEC 60974-1:1998 and IEC 60974-1:1998/AMD1:2000 or earlier, - new Annex D providing additional information to be considered when testing battery-powered welding power sources and connected chargers.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63522-29:2025 This part is used for testing the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use. It specifies how to ensure that the capacitances formed by parts of a relay do not exceed specified limits.

  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60684 gives the requirements for two types of heat-shrinkable, polyolefin sleeving, semiconductive, with a nominal shrink ratio of 3:1. This sleeving has been found suitable up to temperatures of 100 °C. - Type A: Thin wall Internal diameter up to 195,0 mm typically - Type B: Medium wall Internal diameter up to 120,0 mm typically This sleeving is normally supplied in the colour black. Since these types of sleevings cover a significantly large range of sizes and wall thicknesses, Annex A in this standard provides guidance to the range of sizes available. The actual size will be agreed between the user and the supplier. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application need to be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone. This sleeving is designed to be used in MV cable accessories and as such electrical performance will be proven as part of the assembly. Examples of this are described in HD 629 and IEC 60502 (all parts)

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

DEN/ERM-TGAERO-31-1

  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document specifies technical requirements, limits and test methods for Short Range Devices in the non-
specific category operating in the frequency range 25 MHz to 1 000 MHz.
The non specific SRD category is defined by the EU Commission Decision 2019/1345/EU [i.3] as:
"The non-specific short-range device category covers all kinds of radio devices, regardless of the application or the
purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry,
telecommand, alarms, data transmissions in general and other applications".
These radio equipment types are capable of transmitting up to 500 mW effective radiated power and operating indoor or
outdoor.
NOTE: The relationship between the present document and the essential requirements of article 3.2 of
Directive 2014/53/EU [i.2] is given in Annex A

  • Standard
    107 pages
    English language
    sale 15% off
  • Standard
    107 pages
    English language
    sale 15% off
  • Standard
    107 pages
    English language
    sale 10% off
    e-Library read for
    1 day

DEN/ERM-TG28-561

  • Standard
    100 pages
    English language
    sale 15% off
  • Standard
    100 pages
    English language
    sale 15% off
  • Standard
    100 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63461:2024 applies to laboratory model tests of any type of Pelton hydraulic turbine with unit power greater than 5 MW. It contains the rules governing test conduct and provides measures to be taken if any phase of the tests is disputed.
The main objectives of this document are:
- to define the terms and quantities used;
- to specify methods of testing and of measuring the quantities involved, in order to ascertain the hydraulic performance of the model;
- to specify the methods of computation of results and of comparison with guarantees;
- to determine if the contract guarantees that fall within the scope of this document have been fulfilled;
- and to define the extent, content and structure of the final report.
Full application of the procedures herein described is not generally justified for machines with smaller power. Nevertheless, this document can be used for such machines by agreement between the purchaser and the supplier.

  • Standard
    1 page
    English and French language
    sale 15% off

IEC TR 63515:2025 provides a conceptual framework for power system resilience. It covers the definition, evaluation metrics and methods, improvement strategies and uses cases of power system resilience. This document is applicable to developing resilient power system and implementing resilience improvement strategies.
This document is not exhaustive, and it is possible to consider other aspects, such as different application scenarios, evaluation methods, and improvement measures.

  • Technical report
    39 pages
    English language
    sale 15% off

IEC TS 62271-315:2025 is applicable to direct current (DC) transfer switches designed for indoor or outdoor installation and for operation on HVDC transmission systems having direct voltages of 100 kV and above. DC transfer switches normally include metallic return transfer switches (MRTS), earth return transfer switches (ERTS), neutral bus switches (NBS) and neutral bus earthing switches (NBES).

  • Technical specification
    74 pages
    English language
    sale 15% off

IEC TR 62282-7-3:2025 is a generic assessment of the feasibility of standardizing accelerated test procedures (both proton exchange membrane (PEM) and oxide ion-conducting solid oxide cell (SOC) technologies) for fuel cell stacks that have been engineered for a specific system application. This document comprises a review of literature and projects, a discussion of the main physical phenomena of interest in accelerated testing campaigns (focusing on the cell and stack levels, not looking at the system as a black box), a compendium of measurement techniques that are applicable, and it suggests a macroscopic approach to the formulation of a representative accelerated testing campaign.

  • Technical report
    29 pages
    English language
    sale 15% off

IEC TR 61850-90-30:2025, which is a Technical Report, describes extensions of the SCL Substation/Process Section allowing the creation of a comprehensive, IED and hardware independent specification of an IEC 61850 based power system.
It addresses how to:
• decompose functions in SCL
• show function classifications in SCL
• relate functions with the SCL Substation and Process Section
• relate functions to Logical Nodes and IEDs/Specification IEDs
• present information flow between functions in a hardware/implementation independent way
• position Functions in relation to "Application Schemes", "Distributed Functions", "Protection Schemes"
• consider the relationship to Basic Application Profiles (BAP) defined in IEC TR 61850-7-6
The document addresses the engineering process as far as it is related to the specification of Functions and their instantiation in IEC 61850 based power system. This includes the impact on the SCL Process Section during system configuration.
The engineering process related to the definition of Applications and their instantiation is addressed in the Basic Application Profile Document (BAP) in IEC TR 61850-7-6.
The System Configuration process is described in IEC 61850-6.
Modifications and extensions of SCL are done in a way to guarantee backwards compatibility.
In addition, this document introduces:
• Some further elements to SCL that improve the content and usefulness of SSD files and facilitate the handling of SCL files for engineering purposes,
• New variants of IED specific files: ISD file and FSD files,
• Evolution of the engineering rights management, to first improve the usage of SED and add a new concept of System Configuration Collaboration (SCC file) which allows collaboration on the same project with different engineers.

  • Technical report
    184 pages
    English language
    sale 15% off

IEC PAS 62443-2-2: 2025 provides guidance on the development, validation, operation, and maintenance of a set of technical, physical, and process security measures called Security Protection Scheme (SPS). The document’s goal is to provide the asset owner implementing an IACS Security Program (SP) with mechanisms and procedures to ensure that the design, implementation and operation of an SPS manage the risks resulting from cyberthreats to each of the IACS included in its operating facility.
The document is based on contents specified in other documents of the IEC 62443 series and explains how these contents can be used to support the development of technical, physical, and process security measures addressing the risks to the IACS during the operation phase.

  • Technical specification
    44 pages
    English language
    sale 15% off

IEC 60050-831:2025 gives the terms and definitions used in smart cities and smart city systems, as well as general terms pertaining to specific applications and associated technologies. This terminology is consistent with the terminology developed in the other specialized parts of the IEV. It has the status of a horizontal standard in accordance with IEC Guide 108.

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 61000-4-2: 2025 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges from operators directly and from personnel to adjacent objects. It additionally specifies ranges of test levels which relate to different environmental, and installation conditions and establishes test procedures. The objective of this document is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which can occur from personnel to objects near the equipment. This document specifies:
- ideal waveform of the discharge current;
- range of test levels;
- test equipment;
- test setup;
- test procedure;
- calibration procedure;
- measurement uncertainty.
This document gives specifications for tests performed in laboratories and guidance to post-installation tests. This document is not intended to specify the tests to be applied to particular apparatus or systems. The main aim is to give a general basic reference to all concerned product committees. The product committees remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. This document excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging. It is not intended for use in characterizing the performance of ESD protection circuit IEC Guide 107.
This document forms Part 4-2 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) added a calibration requirement for ESD generators with air discharge tip;
b) added a normative annex for test setups for particular kind of equipment (see Annex I);
c) added an informative annex for wearable devices (see Annex J);
d) added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E);
e) moved Clause 9 into a new informative annex (see Annex K);
f) improvement of the current calibration procedure;
g) improvement of the measurement uncertainty considerations with examples of uncertainty budgets;
h) because post-installation tests cannot be performed in a controlled environment, this test method has been moved into a new informative Annex G.

  • Standard
    163 pages
    English and French language
    sale 15% off

IEC 62276:2025 applies to the manufacture of synthetic quartz, lithium niobate (LN), lithium tantalate (LT), lithium tetraborate (LBO), and lanthanum gallium silicate (LGS) single crystal wafers intended for use as substrates in the manufacture of surface acoustic wave (SAW) filters and resonators.
This edition includes the following significant technical changes with respect to the previous edition:
a) The terms and definitions, the technical requirements, sampling frequency, test methods and measurement of transmittance, lightness, colour difference for LN and LT have been added in order to meet the needs of industry development;
b) The term “inclusion” (mentioned in 4.13 and 6.10) and its definition have been added because there was no definition for it in Clause 3;
c) The specification of LTV and PLTV, and the corresponding description of sampling frequency for LN and LT have been added, because they are the key performance parameters for the wafers;
d) The tolerance of Curie temperature specification for LN and LT have been added in order to meet the development requirements of the industry;
e) Measurement of thickness, TV5, TTV, LTV and PLTV have been completed, including measurement principle and method of thickness, TV5, TTV, LTV and PLTV.

  • Standard
    82 pages
    English and French language
    sale 15% off

IEC 62282-7-2:2025 applies to SOFC cell/stack assembly units, testing systems, instruments and measuring methods, and specifies test methods to test the performance of SOFC cells and stacks. This document is not applicable to small button cells that are designed for SOFC material testing and provide no practical means of fuel utilization measurement. This document is used based on the recommendation of the entity that provides the cell performance specification or for acquiring data on a cell or stack in order to estimate the performance of a system based on it. Users of this document can selectively execute test items suitable for their purposes from those described in this document.

  • Standard
    98 pages
    English and French language
    sale 15% off

REN/MSG-TFES-15-3

  • Standard
    67 pages
    English language
    sale 15% off
  • Standard
    67 pages
    English language
    sale 15% off
  • Standard
    67 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ABSTRACT
This test method deals with the acceptance criteria for the magnetic particle examination of forged steel crankshafts and forgings having large main bearing journal or crankpin diameters. Covered here are three classes of forgings, which shall be evaluated under two areas of inspection, namely: major critical areas, and minor critical areas. During inspection, magnetic particle indications shall be classified as: surface indications, which include nonmetallic inclusions or stringers, open or twist cracks, flakes, or pipes; open or pinpoint indications; and non-open indications. Procedures for dimpling, depressing, inspection, and product marking are also mentioned.
SCOPE
1.1 This is an acceptance specification for the magnetic particle inspection of forged steel crankshafts having main bearing journals or crankpins 4 in. [200 mm] or larger in diameter.  
1.2 There are three classes, with acceptance standards of increasing severity:  
1.2.1 Class 1.  
1.2.2 Class 2 (originally the sole acceptance standard of this specification).  
1.2.3 Class 3 (formerly covered in Supplementary Requirement S1 of Specification A456 – 64 (1970)).  
1.3 This specification is not intended to cover continuous grain flow crankshafts (see Specification A983/A983M); however, Specification A986/A986M may be used for this purpose.
Note 1: Specification A668/A668M is a product specification which may be used for slab-forged crankshaft forgings that are usually twisted in order to set the crankpin angles, or for barrel forged crankshafts where the crankpins are machined in the appropriate configuration from a cylindrical forging.  
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.5 Unless the order specifies the applicable “M” specification designation, the material shall be furnished to the inch units.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    5 pages
    English language
    sale 15% off
  • Technical specification
    5 pages
    English language
    sale 15% off

ABSTRACT
This specification covers three types of aluminum-pigmented asphalt roof coatings suitable for application to roofing or masonry surfaces by brush or spray. Type I is nonfibered, Type II is fibered with asbestos, and Type III is fibered other than asbestos. The coatings shall adhere to chemical requirements such as composition limits for water, nonvolatile matter, metallic aluminum, and insolubility in CS2. They shall also meet physical requirements as to uniformity, consistency, and luminous reflectance.
SCOPE
1.1 This specification covers asphalt-based, aluminum-pigmented roof coatings suitable for application to roofing or masonry surfaces by brush or spray.  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.  
1.3 The following precautionary caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    2 pages
    English language
    sale 15% off

ABSTRACT
This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in bath and shower areas as a base for the application of ceramic or plastic tile. Coated glass mat water-resistant gypsum backing panel shall consist of a noncombustible water-resistant gypsum core, surfaced with glass mat, partially or completely embedded in the core, and with a water-resistant coating on one surface. The specimens shall be tested for flexural strength, humidified deflection, core hardness, end hardness, edge hardness, nail pull resistance, water resistance, and surface water absorption. Coated glass mat water-resistant gypsum backing panel shall have surfaces true and free of imperfections that render the panel unfit for its designed use.
SCOPE
1.1 This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in bath and shower areas as a base for the application of ceramic or plastic tile.  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Within the text, the SI units are shown in brackets.  
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    3 pages
    English language
    sale 15% off
  • Technical specification
    3 pages
    English language
    sale 15% off

SIGNIFICANCE AND USE
5.1 The honeycomb tensile-node bond strength is a fundamental property than can be used in determining whether honeycomb cores can be handled during cutting, machining and forming without the nodes breaking. The tensile-node bond strength is the tensile stress that causes failure of the honeycomb by rupture of the bond between the nodes. It is usually a peeling-type failure.  
5.2 This test method provides a standard method of obtaining tensile-node bond strength data for quality control, acceptance specification testing, and research and development.
SCOPE
1.1 This test method covers the determination of the tensile-node bond strength of honeycomb core materials.  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
    sale 15% off

SIGNIFICANCE AND USE
4.1 This procedure measures the amount of hydrogen gas generation potential of aluminized emulsion roof coating. There is the possibility of water reacting with aluminum pigment to generate hydrogen gas. This situation is to be avoided, so this test was designed to evaluate coating formulations and assess the propensity to gassing.
SCOPE
1.1 This test method covers a hydrogen gas and stability test for aluminum emulsified asphalt coatings.  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language
    sale 15% off

SIGNIFICANCE AND USE
4.1 This practice shall be used when ultrasonic inspection is required by the order or specification for inspection purposes where the acceptance of the forging is based on limitations of the number, amplitude, or location of discontinuities, or a combination thereof, which give rise to ultrasonic indications.  
4.2 The acceptance criteria shall be clearly stated as order requirements.
SCOPE
1.1 This practice for ultrasonic examination covers turbine and generator steel rotor forgings covered by Specifications A469/A469M, A470/A470M, A768/A768M, and A940/A940M. This practice shall be used for contact testing only.  
1.2 This practice describes a basic procedure of ultrasonically inspecting turbine and generator rotor forgings. It does not restrict the use of other ultrasonic methods such as reference block calibrations when required by the applicable procurement documents nor is it intended to restrict the use of new and improved ultrasonic test equipment and methods as they are developed.  
1.3 This practice is intended to provide a means of inspecting cylindrical forgings so that the inspection sensitivity at the forging center line or bore surface is constant, independent of the forging or bore diameter. To this end, inspection sensitivity multiplication factors have been computed from theoretical analysis, with experimental verification. These are plotted in Fig. 1 (bored rotors) and Fig. 2 (solid rotors), for a true inspection frequency of 2.25 MHz, and an acoustic velocity of 2.30 in./s × 105 in./s [5.85 cm/s × 105 cm/s]. Means of converting to other sensitivity levels are provided in Fig. 3. (Sensitivity multiplication factors for other frequencies may be derived in accordance with X1.1 and X1.2 of Appendix X1.)  
FIG. 1 Bored Forgings
Note 1: Sensitivity multiplication factor such that a 10 % indication at the forging bore surface will be equivalent to a 1/8 in. [3 mm] diameter flat bottom hole. Inspection frequency: 2.0 MHz or 2.25 MHz. Material velocity: 2.30 in./s × 105 in./s [5.85 cm/s × 105 cm/s].
FIG. 2 Solid Forgings
Note 1: Sensitivity multiplication factor such that a 10 % indication at the forging centerline surface will be equivalent to a 1/8 in. [3 mm] diameter flat bottom hole. Inspection frequency: 2.0 MHz or 2.25 MHz. Material velocity: 2.30 in./s × 105 in./s [5.85 cm/s × 105 cm/s].
FIG. 3 Conversion Factors to Be Used in Conjunction with Fig. 1 and Fig. 2 if a Change in the Reference Reflector Diameter is Required
1.4 Considerable verification data for this method have been generated which indicate that even under controlled conditions very significant uncertainties may exist in estimating natural discontinuities in terms of minimum equivalent size flat-bottom holes. The possibility exists that the estimated minimum areas of natural discontinuities in terms of minimum areas of the comparison flat-bottom holes may differ by 20 dB (factor of 10) in terms of actual areas of natural discontinuities. This magnitude of inaccuracy does not apply to all results but should be recognized as a possibility. Rigid control of the actual frequency used, the coil bandpass width if tuned instruments are used, and so forth, tend to reduce the overall inaccuracy which is apt to develop.  
1.5 This practice for inspection applies to solid cylindrical forgings having outer diameters of not less than 2.5 in. [64 mm] nor greater than 100 in. [2540 mm]. It also applies to cylindrical forgings with concentric cylindrical bores having wall thicknesses of 2.5 [64 mm] in. or greater, within the same outer diameter limits as for solid cylinders. For solid sections less than 15 in. [380 mm] in diameter and for bored cylinders of less than 7.5 in. [190 mm] wall thickness the transducer used for the inspection will be different than the transducer used for larger sections.  
1.6 Supplementary requirements of an optional nature are provided for use at the option of the...

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    English language
    sale 15% off

ABSTRACT
This specification covers austenitic steel castings for valves, flanges, fittings, and other pressure-containing parts. The steel shall be made by the electric furnace process with or without separate refining such as argon-oxygen decarburization. All castings shall receive heat treatment followed by quench in water or rapid cool by other means as noted. The steel shall conform to both chemical composition and tensile property requirements.
SCOPE
1.1 This specification2 covers austenitic steel castings for valves, flanges, fittings, and other pressure-containing parts (Note 1).  
Note 1: Carbon steel castings for pressure-containing parts are covered by Specification A216/A216M, low-alloy steel castings by Specification A217/A217M, and duplex stainless steel castings by Specification A995/A995M.  
1.2 A number of grades of austenitic steel castings are included in this specification. Since these grades possess varying degrees of suitability for service at high temperatures or in corrosive environments, it is the responsibility of the purchaser to determine which grade shall be furnished. Selection will depend on design and service conditions, mechanical properties, and high-temperature or corrosion-resistant characteristics, or both.  
1.2.1 Because of thermal instability, Grades CE20N, CF3A, CF3MA, and CF8A are not recommended for service at temperatures above 800 °F [425 °C].  
1.3 Supplementary requirements of an optional nature are provided for use at the option of the purchaser. The Supplementary requirements shall apply only when specified individually by the purchaser in the purchase order or contract.  
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.4.1 This specification is expressed in both inch-pound units and in SI units; however, unless the purchase order or contract specifies the applicable M-specification designation (SI units), the inch-pound units shall apply. Within the text, the SI units are shown in brackets or parentheses.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    7 pages
    English language
    sale 15% off
  • Technical specification
    7 pages
    English language
    sale 15% off

SIGNIFICANCE AND USE
4.1 Different electroplating systems can be corroded under the same conditions for the same length of time. Differences in the average values of the radius or half-width or of penetration into an underlying metal layer are significant measures of the relative corrosion resistance of the systems. Thus, if the pit radii are substantially higher on samples with a given electroplating system, when compared to other systems, a tendency for earlier failure of the former by formation of visible pits is indicated. If penetration into the semi-bright nickel layer is substantially higher, a tendency for earlier failure by corrosion of basis metal is evident.
SCOPE
1.1 This test method provides a means for measuring the average dimensions and number of corrosion sites in an electroplated decorative nickel plus chromium or copper plus nickel plus chromium coating on steel after the coating has been subjected to corrosion tests. This test method is useful for comparing the relative corrosion resistances of different electroplating systems and for comparing the relative corrosivities of different corrosive environments. The numbers and sizes of corrosion sites are related to deterioration of appearance. Penetration of the electroplated coatings leads to appearance of basis metal corrosion products.  
1.2 The values stated in SI units are to be regarded as the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
    sale 15% off

SIGNIFICANCE AND USE
5.1 Often the most critical stress to which a sandwich panel core is subjected is shear. The effect of repeated shear stresses on the core material can be very important, particularly in terms of durability under various environmental conditions.  
5.2 This test method provides a standard method of obtaining the sandwich core shear fatigue response. Uses include screening candidate core materials for a specific application, developing a design-specific core shear cyclic stress limit, and core material research and development.
Note 3: This test method may be used as a guide to conduct spectrum loading. This information can be useful in the understanding of fatigue behavior of core under spectrum loading conditions, but is not covered in this standard.  
5.3 Factors that influence core fatigue response and shall therefore be reported include the following: core material, core geometry (density, cell size, orientation, etc.), specimen geometry and associated measurement accuracy, specimen preparation, specimen conditioning, environment of testing, specimen alignment, loading procedure, loading frequency, force (stress) ratio and speed of testing (for residual strength tests).
Note 4: If a sandwich panel is tested using the guidance of this standard, the following may also influence the fatigue response and should be reported: facing material, adhesive material, methods of material fabrication, adhesive thickness and adhesive void content. Further, core-to-facing strength may be different between precured/bonded and co-cured facings in sandwich panels with the same core and facing materials.
SCOPE
1.1 This test method determines the effect of repeated shear forces on core material used in sandwich panels. Permissible core material forms include those with continuous bonding surfaces (such as balsa wood and foams) as well as those with discontinuous bonding surfaces (such as honeycomb).  
1.2 This test method is limited to test specimens subjected to constant amplitude uniaxial loading, where the machine is controlled so that the test specimen is subjected to repetitive constant amplitude force (stress) cycles. Either shear stress or applied force may be used as a constant amplitude fatigue variable.  
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. Within the text, the inch-pound units are shown in brackets.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
    sale 15% off

SIGNIFICANCE AND USE
5.1 This test method simulates the hydrostatic loading conditions which are often present in actual sandwich structures, such as marine hulls. This test method can be used to compare the two-dimensional flexural stiffness of a sandwich composite made with different combinations of materials or with different fabrication processes. Since it is based on distributed loading rather than concentrated loading, it may also provide more realistic information on the failure mechanisms of sandwich structures loaded in a similar manner. Test data should be useful for design and engineering, material specification, quality assurance, and process development. In addition, data from this test method would be useful in refining predictive mathematical models or computer code for use as structural design tools. Properties that may be obtained from this test method include:  
5.1.1 Panel surface deflection at load,  
5.1.2 Panel face-sheet strain at load,  
5.1.3 Panel bending stiffness,  
5.1.4 Panel shear stiffness,  
5.1.5 Panel strength, and  
5.1.6 Panel failure modes.
SCOPE
1.1 This test method determines the two-dimensional flexural properties of sandwich composite plates subjected to a distributed load. The test fixture uses a relatively large square panel sample which is simply supported all around and has the distributed load provided by a water-filled bladder. This type of loading differs from the procedure of Test Method C393, where concentrated loads induce one-dimensional, simple bending in beam specimens.  
1.2 This test method is applicable to composite structures of the sandwich type which involve a relatively thick layer of core material bonded on both faces with an adhesive to thin-face sheets composed of a denser, higher-modulus material, typically, a polymer matrix reinforced with high-modulus fibers.  
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text the inch-pound units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    12 pages
    English language
    sale 15% off

DEN/ERM-TGAERO-31-2

  • Standard
    38 pages
    English language
    sale 15% off
  • Standard
    38 pages
    English language
    sale 15% off
  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day