Search Catalog

Standardization Organization
ICS
Technical Committee
Directive
Mandate

This document specifies a method for the measurement of effective focal spot dimensions > 0,2 µm of X-ray systems by means of the edge method applied to digital images taken from hole type or disk type test objects if no phase contrast is observed. The imaging quality and the resolution of X-ray images depends highly on the characteristics of the effective focal spot, in particular its size and two-dimensional intensity distribution as seen from the detector plane.
This document specifies procedures for determining the effective size (dimensions) of standard, mini and micro focal spots of industrial X-ray tubes for users in applications where the pin hole method according to ISO 32543-1 is not applicable. The method specified in this document is applicable for measurement and long-term monitoring of focal spot sizes without a pin hole camera.
This document can be used by manufacturers, if special hole test objects manufactured with lower tolerances according to 6.2.1 are applied (see Figure 1). For measurements of the effective focal spot size, the accuracy of the method in this document is lower than the methods specified in ISO 32543-1 (pin hole method) and ISO 32543-3 (microfocus tubes) if using ASTM hole plate IQIs (see ASTM E1025, ASTM E1742), due to its manufacturing tolerance of ±10 %.
NOTE            For characterization of commercial X-ray tube types (i.e. for advertising or trade), the nominal values of Annex A are preferred.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

IEC 63002:2025 defines common charging interoperability guidelines for power sources (external power supplies (EPSs) and other Sources) used with computing and consumer electronics devices that implement IEC 62680‑1‑3 (USB Type-C® Cable and Connector Specification). This document defines normative requirements for an EPS to ensure interoperability; in particular, it specifies the data communicated from a power source to a device and certain safety elements of the EPS, cable, and device. While the requirements focus of this document is on the EPS and the behaviour at its USB Type-C connector interface, it is also important to comprehend cable assembly and device capabilities and behaviours in order to assure end-to-end charging interoperability. This document does not apply to all design aspects of an EPS. This document does not specify regulatory compliance requirements for aspects such as product safety, EMC, or energy efficiency. This document provides recommendations for the behaviour of a device when used with a power source compliant with this document. It specifies the minimum hardware specification for an EPS implementing IEC 62680‑1‑3. This document also specifies the data objects used by a charging system utilizing IEC 62680‑1‑2 to understand the identity, design and performance characteristics, and operating status of an external power supply. IEC 62680‑1‑2 focuses on power delivery applications ranging to 240 W for a variety of computing and consumer electronics devices including notebook computers, tablets, smartphones, small form-factor desktops, monitor displays and other multimedia devices. This document relies on established mechanical and electrical specifications, and communication protocols specified by IEC 62680‑1‑2 and IEC 62680‑1‑3. These specifications support methods for establishing the best performing interoperability between untested combinations of EPS and devices with the aim of improving consumer satisfaction. Information describing the USB charging interoperability model, overview of USB Type-C and USB Power Delivery specifications, and factors for charging performance are also provided to support implementation of this document. This third edition cancels and replaces the second edition published in 2021. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) power range is increased to 240 W;
b) AVS mode is introduced;
c) Annex A updates issues of arbitrary combinations of AC adapter and device;
d) Annex B describes new safeguards for EPR mode;
e) Annex C and Annex D are updated.

  • Standard
    43 pages
    English language
    e-Library read for
    1 day

This document specifies quality requirements for the chart, test procedure and acceptance level for near, far, and colour vision acuity of NDT personnel. Information for grey scale perception and low contrast can be found in the annexes. This document also specifies the qualification requirements for personnel permitted to carry out the test.
This document is only applicable to vision acuity under defined conditions similar to those encountered during routine NDT inspection. This document does not address an individual’s overall visual acuity and users are advised to consider the need for a general eye examination by specialist medical personnel to ensure general vision acuity.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

This document specifies a normalized railway noise spectrum for the evaluation and assessment of the acoustic performance of devices designed to reduce airborne railway noise near railways.
All noise reducing devices different from noise barriers and related devices acting on airborne sound propagation, e.g. devices for attenuation of ground borne vibration and on board devices are outside of the scope of this document.

  • Standard
    20 pages
    English language
    e-Library read for
    1 day

Creating an amendment to list the EN IEC 60079-15:2019 in OJEU by submitting European elements (Annex ZZ and Annex ZA)

  • Amendment
    8 pages
    English language
    e-Library read for
    1 day

The contents of the corrigendum of March 2023 have been included in this copy.

  • Amendment
    29 pages
    English language
    e-Library read for
    1 day

IEC 60127-7:2026 covers requirements for miniature fuse-links for special applications. This part of IEC 60127 is applicable to fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 125 A and a rated breaking capacity not exceeding 50 kA. It does not apply to fuses completely covered by the subsequent parts of IEC 60269-1. It does not apply to miniature fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres.

  • Standard
    30 pages
    English language
    sale 15% off
  • Standard
    64 pages
    English language
    sale 15% off
  • Standard
    32 pages
    French language
    sale 15% off

IEC 60730-2-24:2026 applies to automatic displacement electrical controls
- for use in, on, or in association with appliances for household and similar use;
NOTE 1 Through this document, the word "control" means "displacement electrical control".
EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa.
- that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
- used in, on, or in association with equipment that use electricity;
- that are mechanically or electrically operated, responsive to change of position of point of action.
NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058‑1‑1.
This document applies to
- inherent safety of automatic electro-mechanical displacement electrical controls;
- functional safety of automatic electro-mechanical displacement electrical controls;
- the operating values, operating times, and operating sequences where such are associated with equipment safety;
- displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9.
This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment.
This document does not
- apply to automatic electronic controls;
- take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies.
NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.
This part 2-24 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the sixth edition of that standard (2022). Consideration may be given to future editions of, or amendments to, IEC 60730‑1. This part 2-24 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for displacement electrical controls. Where this part 2-24 states "addition", "modification" or "replacement", the relevant require­ment, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, part 2-24 indicates that the relevant clause or subclause applies.

  • Standard
    23 pages
    English language
    sale 15% off
  • Standard
    295 pages
    English language
    sale 15% off
  • Standard
    23 pages
    French language
    sale 15% off
  • Standard
    46 pages
    English and French language
    sale 15% off

This document describes a test that determines the rate of leakage of ambient (cold) and medium (warm) temperature smoke from one side of door and shutter assemblies to the other under the specified test conditions. This test method is applicable to door and shutter assemblies and self-closing operable glazed elements of different configurations intended for the purpose of controlling the passage of smoke in case of fire. Wherever door and shutter assemblies are referred to in this document, it also applies to self-closing glazed elements. The fire resistance of glazed elements is determined by tests in accordance with ISO 3009.
The acceptable leakage rates for different situations are not addressed in this document, but rather are specified by the regulations of the controlling authorities.

  • Standard
    28 pages
    English language
    e-Library read for
    1 day
  • Standard
    23 pages
    English language
    sale 15% off

IEC 61803:2026 applies to all high-voltage direct current (HVDC) converter stations with line-commutated converters (LCC) as well with voltage-sourced converters (VSC) used for power exchange (power transmission or back-to-back installation) in utility systems. For line-commutated converters (LCC), this document presumes the use of 12-pulse thyristor converters but can, with due care, also be used for 6-pulse thyristor converters. Where VSC is referred to in this document, it is assumed to be of the MMC-type or similar, with very low harmonic generation. It is important to treat other types of VSC as appropriate. In some applications, synchronous compensators, static var compensators (SVC), or static synchronous compensator (STATCOM) are connected to the AC bus of the HVDC converter station. The loss determination procedures for such equipment are not included in this document. This document presents a set of standard procedures for determining the total losses of an HVDC converter station, except for VSC valves which are covered by the IEC 62751 series. The procedures cover all parts, except as noted above, and address no-load operation and operating losses together with their methods of calculation which use, wherever possible, measured parameters. Converter station designs employing novel components or circuit configurations compared to the typical design assumed in this document, or designs equipped with unusual auxiliary circuits that can affect the losses, are assessed on their own merits.
This edition includes the following significant technical changes with respect to the previous edition:
a) HVDC stations with voltage-sourced converters (VSC) technology have been included;
b) to facilitate the application of this document and to ensure its quality remains consistent, 5.1.8 and 5.8 have been reviewed, taking into consideration that the present thyristor production technology provides considerably less thyristor parameters dispersion comparing with the situation in 1999 when the first edition of IEC 61803 was developed; therefore, the production records of thyristors can be used for the power losses calculation;
c) the calculation of the total station load losses (cases D1 and D2 in Annex C) has been corrected.

  • Standard
    43 pages
    English language
    sale 15% off
  • Standard
    86 pages
    English language
    sale 15% off
  • Standard
    45 pages
    French language
    sale 15% off

IEC TS 62332-1:2026 specifies a dual-temperature test procedure for the thermal evaluation and qualification of electrical insulation systems (EISs). This document is applicable to EISs containing solid and liquid components where the thermal ageing factor is dominant, without restriction to voltage class. This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- Modifications have been made based on an extensive test series conducted using this methodology based on the first edition. This included updating expected times and temperatures to use in order to get useful results, as well as making the range of equipment covered more broad. The method now covers electrotechnical devices using different sealing systems, as well as devices using enamel covered wires.

  • Technical specification
    20 pages
    English language
    sale 15% off
  • Technical specification
    41 pages
    English language
    sale 15% off

This document describes the typical accessories used for Large Power Transformers.

  • Standard
    9 pages
    English language
    e-Library read for
    1 day

This document specifies a method for the determination of di-tert-butyl peroxide (DTBP) and 2, 5-Dimethyl-2, 5-di (tert-butylperoxy) hexane (DBPH) in plastics by using gas chromatography. This document is applicable to the determination of the content of residual peroxides in plastics and their products, which use peroxides as a degradation agent or crosslinking agent during plastics processing, or as an additive during polymerization, thereby remaining in degraded polypropylene, crosslinked polyethylene, polystyrene and other plastics. NOTE The applicability of this method to other peroxides is possible when the method is validated for each case.

  • Standard
    13 pages
    English language
    sale 15% off

This document gives guidance and requirements for the assessment of conformity of formulations, products and assemblies in accordance with EN 1329-1:2026 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   A basic test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2   If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065[1] and EN ISO/IEC 17020[2] is considered to be competent.

  • Technical specification
    22 pages
    English language
    e-Library read for
    1 day

This document, published jointly by IEC and ISO, provides, in combination with IEC 81346‑1 and IEC 81346‑2, rules and recommendations on the structuring of systems and the information on systems of manufacturing systems. It also provides additional classification schemes to those of IEC 81346‑2 for use in reference designations within manufacturing systems. It is published as a double logo standard. The structuring principles and the classes of objects are intended to provide a clear identification and localization of the objects, and for use in their labelling in the manufacturing plant, for their designation in technical documents and for the designation of the technical documents as well. The requirements in this document apply for processing, transportation and storage of products, as well as for systems to support the manufacturing process such as electrical systems, management systems and waste disposal systems. This document applies to different areas within the manufacturing industry such as light industry, electrical and optical industry, chemical industry, material industry and heavy industry. This document is not applicable for designations related to product individuals (e.g. inventory number, serial number) nor to the products manufactured. This document is also a horizontal publication intended for use by technical committees in preparation of publications related to reference designations in accordance with the principles laid down in IEC Guide 108.

  • Standard
    28 pages
    English language
    sale 15% off
  • Standard
    31 pages
    French language
    sale 15% off

This document specifies methods for the measurement of the thermal resistance and water-vapour resistance , under steady-state conditions, of e.g. fabrics, films, coatings, foams and leather, including multilayer assemblies, for use in clothing, quilts, sleeping bags, upholstery and similar textile or textile-like products. The application of this measurement technique is restricted to a maximum thermal resistance and water-vapour resistance which depend on the dimensions and construction of the apparatus used (e.g. 2 m2·K/W and 700 m2·Pa/W respectively, for the minimum specifications of the equipment referred to in this document). The test conditions used in this document are not intended to represent specific comfort situations, and performance specifications in relation to physiological comfort are not stated.

  • Standard
    17 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off

This document provides test methods and test requirements for design either qualification or acceptance, or both of small spacecraft or units. It provides the minimum test requirements and test methods to qualify the design and manufacturing methods of commercial small spacecraft and their units and to accept the final products. This document is applicable to satellites whose development methods are different from the ones used for traditional satellites that have little room for risk tolerance. The scope of this document encompasses different categories of small spacecraft, so-called mini-, micro-, nano-, pico- and femto spacecraft. This document includes CubeSat, as long as it is developed with the untraditional processes. This document does not cover satellite deployment mechanisms, such as picosatellite orbital deployer (POD), as the verification requirements are defined in the interface control document (ICD) with the launcher, such as ISO 26869[1]. This document does not cover software testing, although some tests such as functional test, mission test and end-to-end test are inherently used to test the software installed in the hardware being tested. General requirements and processes of satellite software testing can be found in various references, such as ECSS-E-ST40[2]. This document does not cover requirements regarding safety nor debris mitigation. Appropriate documents such as ISO 14620-1[3] or ISO 24113[4] can be referred to. Other common requirements for small spacecraft can be found in ISO 20991[5].

  • Standard
    92 pages
    English language
    sale 15% off

This document is applicable to all electronic equipment for control, regulation, protection, diagnostic, energy supply installed on railway vehicles and any relevant elements of rolling stock subsystems (e.g. external doors, On-Board ETCS functionality, wheel slide protection).
For the purpose of this document, electronic equipment is defined as equipment composed of electronic components (e.g. resistors, capacitors, transistors, diodes, integrated circuits, hybrids, application specific integrated circuits, wound components and relays), and recognized associated components (e.g. connectors, mechanical parts). These components are mainly mounted on printed circuit boards.
Sensors (e.g. current, voltage, speed) and semiconductor drive units for power electronic devices are covered by this document. Complete semiconductor drive units and power converters are covered by EN 61287 1.
This document covers the requirements for operating conditions, design, documentation, testing and integration of electronic equipment, as well as hardware and software requirements considered necessary for compliant and reliable equipment.
Specific requirements related to practices necessary to ensure defined safety integrity level or functional safety are not covered by this document. Nevertheless, this document is applicable to the hardware of all rolling stock electronic equipment or systems performing safety-related functions.
The software development requirements for on-board railway equipment are specified by EN 50716.

  • Standard
    112 pages
    English language
    e-Library read for
    1 day

IEC 62301:2026 specifies methods of measurement of electrical power in standby mode(s) and other non-active modes (such as off mode) and the reporting of the results. The measurement of power and energy use in networked standby mode, is covered by IEC 63474:2026.
This document applies to electronic and electrical equipment powered by:
- low voltage AC power (LV ≤ 1 000 V AC), or
- low voltage DC power (LV ≤ 1 500 V DC) that is ripple-free, measured between conductors or between a conductor and earth, or
- extra low voltage AC power (ELV ≤ 50 V AC), or
- extra low voltage DC power (ELV ≤ 120 V DC) that is ripple-free, measured between conductors or between a conductor and earth, or
- an external power supply that provides low voltage or extra low voltage AC or DC power, or
- a separate source of extra low voltage DC power, or
- an internal main battery.
Conditions that are out of scope:
- active modes (primary function)
- networked standby mode (which is covered by IEC 63474:2026)
- conditions where main batteries are being charged other than in maintenance mode
- disconnected condition of the equipment.
This document applies to the following product groups where a non-active mode is present:
- household appliances, electrical and electronic equipment such as information technology equipment, audio, video and multimedia systems and equipment,
- gas burning equipment with electrical components.
The measurement of power, energy use and performance of products during their intended use (when performing their primary functions) are generally specified in product standards and are not covered by this document.
Where this document is referenced by performance standards or procedures, these are to define and name the relevant non-active mode to which this test procedure is applied.
Non-active modes for lighting equipment and the measurement of power is specified in IEC 63103.
Edge equipment can also include auxiliary batteries.
Annex A shows the conceptual framework of power modes and functions.
This document does not specify safety requirements. It does not specify minimum performance requirements nor does it set maximum limits on power or energy use.
This document has the status of a group energy efficiency publication in accordance with IEC Guide 118.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) expansion of the scope in line with the approved horizontal application of this standard;
b) inclusion of battery powered and DC powered devices;
c) complete revision and expansion of the definitions (this has been done in conjunction with TC 100/TA19 JWG2 and the definitions in this document and IEC 63734:2026 for networked standby are fully aligned);
d) clarification that this document covers all non-active modes except for networked standby mode(s), which is covered by IEC 63734:2026;
e) reiteration that a wide range of product committees and their standards can reference this document and that they are free to define modes relevant for their products and to some extent measurement conditions that may be product specific, while using the broad methodology set out in this document;
f) more precise specification of room illuminance requirements has been added, where required;
g) mandatory requirements for data logging of test data;
h) requirement that no data loss or out of range records occur within the data set being used to assess product performance;
i) removal of the Average reading method and Direct meter reading method as valid measurement methods;
j) greater detail in set-up procedures;
k) revision of stability requirements, including the refinement of linear regression validity requirements and cyclic load validity requirements, and the introduction of a new alternative approach called the moving average method t

  • Standard
    57 pages
    English language
    sale 15% off

This document specifies methods for the determination of seam maximum force of sewn seams when the force is applied perpendicularly to the seam. It describes the method known as the grab test.
The method defined in this document is applicable to woven textile fabrics, including fabrics which exhibit stretch characteristics imparted by the presence of an elastomeric fibre, mechanical or chemical treatment. It can be applicable to fabrics produced by other techniques. It is normally not applicable to geotextiles, nonwovens, coated fabrics, textile-glass woven fabrics and fabrics made from carbon fibres or polyolefin tape yarns.[2], [3], [4]
This method is applicable to straight seams only (obtained from previously sewn articles or prepared from fabric samples) and not to curved seams (see Annex B for considerations on seams).
The method is restricted to the use of constant-rate-of-extension (CRE) testing machines.

  • Standard
    21 pages
    English language
    e-Library read for
    1 day

IEC 61375-1:2026 applies to the architecture of data communication systems in open trains, i.e. it covers the architecture of a communication system for the data communication between vehicles of the said open trains, the data communication within the vehicles and the data communication from train to the ground. The applicability of IEC 61375-1 to the train network technologies allows for interoperability of individual vehicles within open trains in international traffic. The data communication systems inside vehicles are given as recommended solutions to cope with the said TCN. In any case, proof of compatibility between a proposed train backbone and a proposed consist network will have to be brought by the supplier. IEC 61375-1 might be additionally applicable to closed trains and multiple unit trains when so agreed between purchaser and supplier. This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Extension of train backbone topologies: aggregated and segregated topology;
b) Added independent consist orientation check with segregated train backbone topology;
c) Introduction of wireless technologies: wireless train backbone and wireless consist network;
d) Possibility of virtual networks;
e) Definition of data classes and protocol requirements suitable for the OMTS domain;
f) New clause about cybersecurity in train communication networks.

  • Standard
    66 pages
    English language
    e-Library read for
    1 day

This document provides a workflow comprising experimental procedures and flaw detection algorithms aimed at locating flaws in parts produced during the powder bed fusion-laser-based (PBF-LB) process of metals. It emphasizes the use of coaxial photodiode-based in-situ monitoring and statistical and clustering machine learning algorithms, particularly for detecting lack of fusion-induced flaws. The workflow delineates setting thresholds for statistical detection and determining the number of clusters for machine learning algorithms, utilizing intentional seeded flaws in parts. Validation procedures are provided through computed tomography scanner data. Hardware limitations and considerations for multi-laser processes are addressed, with attention to potential issues.

  • Technical report
    25 pages
    English language
    sale 15% off

This document specifies fundamental concepts of the reference model for textual documents and provides guidance to support long-term preservation from the perspectives of its five layers. It defines: the layers that constitute the reference model for textual documents; the types of elements incorporated within textual documents; property types associated with textual documents; classifications of properties by type; and properties inherent to textual documents relevant to long-term preservation. This document does not cover: specific technical methods for checking whether the properties exist within a specific textual document; specific technical methods for analysing particular textual document format (e.g. DOC, DOCX, ODT, TXT, PDF); specific metadata items for the long-term preservation of textual documents; processes, procedures, or management practices related to long-term preservation or records management.

  • Standard
    22 pages
    English language
    sale 15% off

IEC 62820-1-1 specifies the technical requirements for the composition, functions, performance, and test methods of general building intercom systems.
This document is applicable to the general intercom systems for building entry in residential or commercial buildings.
Door-Entry-System (DES) is a simple kind of convenient Building-Intercom-System (BIS) mainly for user’s comfort. This document has classified the general building intercom systems into two grades in IEC 62820-1-1. Grade 1 adopts lower requirements to cover DES not used for relevant security applications while grade 2 adopts higher requirements for building intercom systems for security applications. Each grade can adopt different functional and performance requirements, test methods and normative references.
NOTE The different requirements between grade 1 and grade 2 are summarized in Table C.1 of Annex C.

  • Standard
    47 pages
    English language
    e-Library read for
    1 day

This document specifies processes for the management and operation of data centres. The primary focus of this document is the processes necessary to deliver the expected level of resilience, availability, risk management, risk mitigation, capacity planning, security and resource and energy efficiency.
The secondary focus is on organization and data centre management to align the actual and future demands. Only processes specific for data centres are in the scope of this document.
Business processes like people management, financial management, etc. are out of scope.

  • Standard
    70 pages
    English language
    e-Library read for
    1 day

This document specifies a method of preparing a ground sample of spice or condiment for analysis, from a laboratory sample obtained by the method specified in ISO 948.
This document is applicable to the majority of spices and condiments. However, in view of the large number and diversity of spices and condiments, it can be necessary in certain special cases, for example, considerable hardness, or high moisture, volatile oil or fat content, to use a modified procedure or to choose another more
suitable method. Any such modified procedure or alternative method will be indicated in the International Standard appropriate to the spice or condiment concerned.

  • Standard
    9 pages
    English language
    e-Library read for
    1 day

This document: gives an overview of the ISO 17978 series; specifies rules and basic principles for the service-oriented vehicle diagnostics (SOVD), conforming to the extended vehicle (ExVe) methodology, as specified in the ISO 20077 series; defines general terms.

  • Standard
    13 pages
    English language
    sale 15% off

The present document defines specific QCStatement for the qcStatements extension as defined in IETF RFC 3739 [2], clause 3.2.6, including requirements for their use in EU qualified certificates. Some of these QCStatements can be used for other forms of certificate. The QCStatements defined in the present document can be used in combination with any certificate profile, either defined in ETSI EN 319 412-2 [i.2], ETSI EN 319 412-3 [i.5] and ETSI EN 319 412-4 [i.6], or defined elsewhere. The QCStatements defined in clause 4.3 can be applied to regulatory environments outside the EU. Other requirements specified in clause 4 are specific to Regulation (EU) No 910/2014 [i.8] but may be adapted for other regulatory environments.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English language
    e-Library read for
    1 day

This document specifies a semantic data model of the core elements of an Electronic invoice. The semantic data model includes only the essential information elements that an Electronic invoice needs to ensure legal (including fiscal) compliance and to enable interoperability for cross-border, cross sector and domestic trade. The semantic data model can be applied by organizations in the private and the public sector for public procurement invoicing. It can also be used for invoicing between private sector enterprises. It has not been specifically designed for invoicing consumers.
This document complies at least with the following criteria:
— it is technologically neutral;
— it is compatible with relevant international standards on electronic invoicing;
— the application of this standard should comply with the requirements for the protection of personal data of Directive 95/46/EC, having due regard to the principles of privacy and data protection bydesign, data minimization, purpose limitation, necessity and proportionality;
— it is consistent with the relevant provisions of Directive 2006/112/EC [2];
— it allows for the establishment of practical, user-friendly, flexible and cost-efficient electronic invoicing systems;
— it takes into account the special needs of small and medium-sized enterprises as well as of subcentral contracting authorities and contracting entities;
— it is suitable for use in commercial transactions between enterprises.

  • Standard
    163 pages
    English language
    e-Library read for
    1 day

This document specifies test methods for fitting assemblies used in aircraft fluid systems in the pressure and temperature ranges covered by pressure from classes B, to K, and temperature types I, II and III of ISO 6771. This document applies each time that it is referred to in a procurement specification or other definition document which contains the pass and fail criteria for these tests.

  • Standard
    6 pages
    English language
    sale 15% off
  • Standard
    6 pages
    French language
    sale 15% off

This document specifies the general requirements relating to the design of ballastless track systems, including configuration of ballastless track system, subsystems and components requirements, and other related interfaces.

  • Standard
    33 pages
    English language
    sale 15% off
  • Standard
    34 pages
    French language
    sale 15% off

This document is applicable to products that emit laser radiation for the purpose of free space optical data transmission. This document does not apply to laser products designed for the purposes of transmitting optical power for applications such as material processing or medical treatment. This document also does not apply to the use of laser products in explosive atmospheres (see IEC 60079-0). Light-emitting diodes employed by free space optical communication systems, used for the purpose of free space optical data transmission, do not fall into the scope of this document. NOTE If the laser product incorporates an optical fibre that extends from the confinements of the enclosure, the requirements in IEC 60825-2 applies.

  • Draft
    50 pages
    English language
    e-Library read for
    1 day

This document specifies the digital measurement method for the determination of the anti-contamination of fabrics. This method is applicable to woven fabrics which have or have not been given an anti-contamination to particulate matter finish. It is especially suitable for measuring apparel fabrics. It is not intended for use in fabrics that react to UV light or allow particulate matter to penetrate into the structure of the fabric. It is not applied to fabrics for personal protective equipment. NOTE 1 Particulate matter (PM) is solid particles suspended in ambient air defined in ISO 16890-1. NOTE 2 In woven fabrics, particulate matter (PM) adheres to the fabric surface due to electrostatic or surface properties. In knitted and nonwoven fabrics, PM penetrates into the fabric structure, following a different mechanism. The conditions and procedures outlined in this test method are designed to ensure reproducibility and precision specifically when applied to woven fabrics.

  • Standard
    8 pages
    English language
    sale 15% off

IEC 60947-6-1:2026 is available as IEC 60947-6-1:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60947-6-1:2026 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. Specific requirements for bypass/isolation transfer switch equipment are given in Annex C, ATSE having closed transition capability are given in Annex D, stand-alone ATS controllers are given in Annex E, and TSE for electric driven fire pump controllers are given in Annex F. It covers: - manually operated transfer switching equipment (MTSE); - remotely operated transfer switching equipment (RTSE); - automatic transfer switching equipment (ATSE), including the controller; - stand-alone ATS controllers; - bypass/isolation transfer switch equipment (BTSE); - ATSE having closed transition capability; - fire pump TSE. It does not cover: - TSE configurations that are not fully manufacturer type tested or marked according to this document as a complete transfer switch; - auxiliary contacts (for guidance, see IEC 60947-5-1); - transfer switches used in explosive atmospheres (for guidance, see IEC 60079 (all parts)); - embedded software design (for guidance, see IEC TR 63201); - cybersecurity aspects (for guidance, see IEC 63208); - TSE rated for direct-on-line starting asynchronous motor of design NE and HE, according to IEC 60034-12. (for guidance, see AC-3e utilisation category according to IEC 60947 4 1); - other types of TSE under consideration including overlapping neutral TSE, multi-source TSE (i.e. TSE with more than two sources of supply), TSE with load-shedding functions, bus-tie TSE, and hybrid TSE; - static transfer switches covered by IEC 62310 series. This fourth edition cancels and replaces the third edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - clarification of scope; - clarification of terms and definitions; - Annex C for Bypass/Isolation Transfer Switch Equipment; - Annex D for ATSE having closed transition capability; - Annex E for Stand-alone ATS controller; - Annex F for TSE used with electric driven fire pump control equipment.

  • Draft
    100 pages
    English language
    e-Library read for
    1 day

This document specifies rules for indicating the tolerance for surface form deviation, in the ISO 10110 series, which standardizes drawing indications for optical elements and systems. NOTE The terminology of interferometry employing the unit “fringe spacings” is widely used for the specification of tolerances. However, the usage of non-interferometric methods for testing of optical parts has recently become more important. Therefore, unlike in the earlier versions of this document, nanometres are now the preferred and standard unit to express surface form deviations. The usage of fringe spacings is still permitted, provided that the base wavelength is explicitly stated. This document applies to surfaces of plano, spherical, aspheric, cylindric, and toric form as well as to surfaces of other non-spherical shape such as generally described surfaces. It also applies to the substrates of diffractive surfaces; for transmitted or reflected wavefront specifications see ISO 10110-16 and ISO 10110-14.

  • Standard
    28 pages
    English language
    sale 15% off
  • Standard
    31 pages
    French language
    sale 15% off

This document is applicable to ventilation systems in commercial kitchens, associated areas and other installations processing foodstuffs intended for commercial use. Kitchens and associated areas are special rooms in which meals are prepared, where tableware and equipment are washed and cleaned, food is stored, and food waste areas.
This document specifies requirements and gives recommendations for the configuration, installation, testing, maintenance and safety of fixed kitchen fire extinguishing systems within the design of commercial kitchens in buildings. It is applicable for fire extinguishing systems providing appliance-specific protection as well as overlapping zone protection.
This document provides the guidelines to install fixed fire extinguishing systems to protect against grease fires on the cooking appliances in the extract ventilation system. This document includes recommendations for the certification of system hardware, as well as design, installation and maintenance of the system.
NOTE   It is possible that there are additional or alternative local national regulations on installation, appliance requirements and inspection, maintenance and operation.
This document is applicable to kitchen ventilation systems excluding those in domestic kitchens.

  • Standard
    14 pages
    English language
    e-Library read for
    1 day

This document specifies general methods, with suitable test conditions, for the determination of the ash of a range of plastics. The particular conditions chosen can be included in the specifications for the plastic material in question. Particular conditions applicable to poly(alkylene terephthalate) materials, unplasticized cellulose acetate, polyamides and poly(vinyl chloride) plastics, including some specific filled, glass-fibre-reinforced and flame-retarded materials, are specified in ISO 3451-2, ISO 3451-3, ISO 3451-4 and ISO 3451-5.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off

This document specifies a test method for the verification of the resistance to hydrostatic pressure of explosives for blasting and a test method for the verification of the resistance to hydrostatic pressure of explosives for boosters.
This document does not apply to black powder.
This document does not apply to explosive substances.

  • Corrigendum
    2 pages
    English language
    e-Library read for
    1 day

This document specifies definitions, principles of construction (but not dimensions) and design, requirements on performance and operation as well as methods for testing the performance of adjustable chemical dosing systems for conditioning water intended for human consumption inside buildings (see [1]) which are permanently connected to the mains supply.

  • Standard
    18 pages
    English language
    e-Library read for
    1 day

This document specifies the general requirements for cell viability analytical methods and for reporting cell viability. This document gives general guidelines for selecting and establishing fit for purpose cell viability analytical methods. This document specifies requirements for establishing standard operating procedures for cell viability analytical methods. This document also gives guidelines for managing sources of variability for cell viability measurements during pre-analytical, analytical, and post-analytical phases. This document is applicable to cells in suspension, cells adhered to a substrate, and cells in complex matrices. This document is primarily applicable to cell viability measurements of nucleated mammalian cells. NOTE 1 Several sector/application-specific international and national standards for cell viability currently exist. NOTE 2 When applicable, the user can consult existing standards when operating within their scope.

  • Standard
    53 pages
    English language
    sale 15% off

IEC 60669-2-4:2024 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors. This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the present edition with reference to the published IEC 60669-1:2017 Edition 4 with its amendments and references to clauses and tables;
b) introducing the values for isolating switches with ratings from 6 A to 13 A;
c) introducing a circuit motor load with a rated current not exceeding 10 A and a power factor not less than 0,6 in the scope;
d) modification of Table 1 and Table 5.

  • Standard
    37 pages
    English language
    e-Library read for
    1 day

This document specifies a procedure for obtaining a migration water to determine odour, flavour, colour and turbidity for products made from organic materials intended to come in contact with water for human consumption (drinking water) and used in piping and storage systems. Such products include pipes, tanks, reservoirs, fittings, ancillaries and their coatings both for site applied and factory-made products.
This document is applicable to products to be used under various conditions for the transport, storage and distribution of water intended for human consumption and raw water used for the manufacture of water intended for human consumption.
This document specifies a test method comprising a set of procedures. The use may be dependent on the relevant national regulations and/or the Commission Implementing Decision (EU) 2024/368.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

This document specifies the requirements and methods for the clinical investigation of medical electrical (ME) equipment used to measure the body temperature in indirect measurement mode. This document covers both intermittently and continuously measuring clinical thermometers. NOTE 1 This document does not apply to clinical thermometers measuring the body temperature in direct measurement mode. NOTE 2 For clinical thermometers in direct measurement mode determining the technical accuracy in accordance with ISO 80601-2-56:—1) is considered sufficient. This document is applicable to clinical thermometers with claimed measurement time shorter than 60 seconds (for methods such as oral or rectal measurement), or shorter than 5 minutes (for methods such as axillary measurement), and which are treated as predictive type thermometers and fall under the scope of this document. This document specifies additional disclosure requirements. This document does not apply to the clinical investigation of a screening thermographs for human febrile temperature screening whose laboratory accuracy requirements are described in IEC 80601-2-59. This document does not apply to pulmonary artery catheter for the determination of cardiac output by thermodilution. NOTE 3 ISO 80601-2-56:—1) does include pulmonary artery catheter for the determination of cardiac output by thermodilution.

  • Standard
    25 pages
    English language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off