Building on the consolidated definitions of NbS, this document establishes a terminology to support the development of an agreed vocabulary, forming the basis of the standardisation process.
- Standard42 pagesEnglish languagee-Library read for1 day
Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does not apply to heating appliances incorporated in the building structure, to central heating systems or to floor heating appliances.
- Amendment14 pagesEnglish languagee-Library read for1 day
This document applies to personal dosemeters with the following characteristics:
a) They are worn on the trunk, close to the eye, or on the extremities.
b) They measure the personal dose equivalents Hp(10), Hp(3), and Hp(0,07), from external X and gamma, neutron (not for Hp(3)), and beta radiations, and may measure the respective personal dose equivalent rates for the same radiations (for alarming purposes).
c) They have a digital indication. This indication may or may not be attached.
d) They have alarm functions for the personal dose equivalents or personal dose equivalent rates except for hybrid dosemeters. For hybrid dosemeters an alarm function for the personal dose equivalents shall be implemented in the associated readout system.
- Standard86 pagesEnglish languagee-Library read for1 day
This document specifies the cloud computing reference architecture (CCRA).
- Standard67 pagesEnglish languagee-Library read for1 day
- Amendment7 pagesEnglish languagee-Library read for1 day
The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
This document defines the environmental tests in particular the climatic and corrosion ageing tests. The objective of these tests is to predict the behaviour of ABC accessories when subjected to sun radiation, to weather conditions (humidity, spraying water, heat, cold) and pollution. EN 50483-1, EN 50483-2, EN 50483-3 and EN 50483-4 specify which type tests included in this part of the standard are needed.
- Standard26 pagesEnglish languagee-Library read for1 day
- Corrigendum1 pageEnglish languagee-Library read for1 day
- Standard1 pageEnglish languagesale 15% off
This document defines the general considerations applicable to any type of remote monitoring and control system (RMCS) used in irrigation. The document also includes some specific clauses on RMCS that fully or partially incorporate controllers developed for irrigation. These controllers are specific hardware developments designed for specific irrigation monitoring and/or control requirements. An indication is given at the beginning of each section that clearly defines when it is specifically intended for controllers developed for irrigation.
- Standard18 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
This document gives guidance on the procedure for the bioaccumulation of substances liable to cause atmospheric pollution. This is done by using the grass species Lolium multiflorum ssp. italicum designated hereafter as Italian rye-grass. It is an active biomonitoring approach insofar as the plants used are first cultivated in set conditions before being exposed at the monitoring locations in the field. The plants then record any pollution events that occur while they are being exposed, allowing such events to be accurately dated.
The document specifies a method for identification and localization of one or more single pollution sources and the tracking of their "plume" on a local or regional scale. The method described also offers a tool to monitor sites in the long term by the repeated application of a clearly defined procedure and to describe the local or regional air pollution situation.
The method described in this document is applicable to solid and gaseous substances deposited on plants, where they can accumulate on their surface or in their tissues. These substances include sulphur, chloride, fluoride and especially metals as well as low volatile organic and halo-organic compounds such as polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), polybrominated diphenyl ethers (PBDE), polychlorinated dibenzo dioxins (PCDD) and polychlorinated dibenzo furans (PCDF). It is as well possible to verify pesticides which are used in plant protection products. The range of potential substances can be expanded according to the task at hand and the capabilities of conducting trace analyses and assessment.
The method described in this document allows spatial and temporal comparisons and allows for screening, thus providing a first indication of risk. The results of grass culture studies can suggest risks to biota (e.g. via the food chain) which require further investigation.
The method described in this document does not replace physico-chemical methods of direct measurement or modelling of air pollutants and cannot be replaced by them for its part; it complements them by indicating biological effects.
Potential areas of deployment are:
- permit procedures related to air pollution legislation;
- preservation of evidence related to the code for protection from pollution;
- monitoring of emission sources and performance control;
- assessment of local-scale emission transport;
- evidence of causation, e.g. related to environmental liability;
- air quality maintenance plans/strategies;
- long-term monitoring of ecological effects of atmospheric depositions;
- detection and assessment of local, regional, and countrywide effects of atmospheric depositions;
- assessment of risks for humans and/or animals via the food chain.
This document is of interest to those involved in environmental monitoring.
- Standard44 pagesEnglish languagee-Library read for1 day
This part of IEC 62676 specifies the functions, performance, interfaces, environmental adaptability, test methods, performance evaluation and grading rules of real-time intelligent video analysis in surveillance systems.
This document applies to live and forensic, real-time intelligent video analysis devices and systems in video surveillance.
The document is centred on testing performance and grading device functionality which enables:
• Core capability: Classification of objects, detection of specific "object activity", such as "stopping", "starting", "direction of movement", etc.
Examples are listed in Annex A.
• Complex capability: Detection of "scenarios" which are based on combinations of object activity, such as "loitering", "perimeter intrusion detection", "person down", "tailgating", "intrusion", "abandoned object detection", explosion, fire, flood, potential terrorist attack using a vehicle, owner of an abandoned bag, etc.
Examples of current scenarios are listed and described in Annex B.
• Degree of difficulty: The application of real operating environments to test the performance under known or required operating stress levels, examples of operating stress levels that are sterile or non-sterile, indoor or outdoor, target obscuration levels, extreme weather conditions, vibrating mechanical rugged environments causing image shake resulting in degradation of image quality requirement, see Table 1 and Annex C.
The purpose of this document is to provide end users, at different levels of the service process, from users and installers, integrators and maintenance companies, to certification providers, with methods to measure the performance of video analysis systems that must also comply with other parts of the standard.
- Standard228 pagesEnglish languagee-Library read for1 day
This document specifies requirements for the contents of a technical file to demonstrate the fulfilment of regulatory requirements for an endosseous dental implant that can include:
implant body;
implant abutment;
abutment screw;
implant connecting part;
implant connecting part screw;
prosthetic screw;
implant cover screw;
transmucosal healing component.
This document also specifies requirements for intended use and performance, design attributes, components, biocompatibility, manufacturing, packaging, sterilization, shelf life, marking, labelling and information supplied by the manufacturer.
This document does not apply to the following devices:
dental implants incorporating animal or human components or bioactive characteristics;
custom-made devices that have no pre-fabricated connection;
implantable materials for bone filling and augmentation in oral and maxillofacial surgery;
membrane materials for guided tissue regeneration in oral and maxillofacial surgery;
specific instruments indicated to be used as part of a dental implant system.
NOTE 1 ISO 22794 specifies the necessary content of technical files for implantable materials for bone filling and augmentation in oral and maxillofacial surgery. ISO 22803 specifies the necessary content of technical files for membrane materials for guided tissue regeneration in oral and maxillofacial surgery. These materials require a separate technical file.
NOTE 2 ISO 13504 gives the general requirements for specific instruments indicated to be used as part of a dental implant system. These instruments require a separate technical file.
NOTE 3 Custom-made devices are defined in IMDRF/PMD WG/N49 [5].
- Standard20 pagesEnglish languagee-Library read for1 day
This document gives guidelines for establishing severity assessment criteria for anomalies identified by airborne (AB) and structure-borne (SB) ultrasound, specifies methods and requirements for carrying out ultrasonic inspection, testing, measurement and monitoring of machines, including safety recommendations and sources of error, and provides information relative to data interpretation, assessment criteria and reporting.
- Standard22 pagesEnglish languagesale 15% off
This document defines standardized and repeatable test procedures for the evaluation of blowby oil aerosol separators and filtering devices and specifies laboratory gravimetric separation efficiency and system pressure tests in both open and closed crankcase ventilation systems. This document has a limitation of 0 % to 99 % for aerosol gravimetric efficiency. NOTE Gravimetric efficiencies > 99 % can be difficult to measure due to long test durations and absolute filter weight measurements. Filter life is not evaluated in this document. This test method only applies to devices that have a defined tubular inlet, outlet and drain that can be connected to the test equipment. For devices that lack such connections, for example, one that is built into a valve cover, see Annex A.
- Technical specification22 pagesEnglish languagesale 15% off
This document specifies requirements for the optical and geometrical properties of semi-finished blanks.
- Standard16 pagesEnglish languagesale 15% off
- Standard17 pagesFrench languagesale 15% off
IEC 61196-1-326:2026 specifies the test methods of clamps for laying coaxial communication cable, including mechanical test methods and environmental test methods.
This document applies to clamps for laying coaxial communication cables, including feeder and radiating cables. For requirements not covered in IEC 61914, clamps for other types of cables can also refer to this document.
This second edition cancels and replaces the first edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Addition of Clause 4 to Clause 15.
- Standard40 pagesEnglish languagesale 15% off
This document specifies the requirements for an environmental management system that an organization can use to enhance its environmental performance. It is intended for use by an organization seeking to manage its environmental responsibilities in a systematic manner that contributes to the environmental pillar of sustainability. This document helps an organization to achieve the intended outcomes of its environmental management system, which provide value for the environment, the organization itself and interested parties. The intended outcomes of an environmental management system include: enhancing environmental performance; meeting compliance obligations; achieving environmental objectives. This document is applicable to any organization, regardless of size, type or nature, and applies to the environmental aspects of its activities, products and services that the organization determines it can either control or influence considering a life cycle perspective. This document does not state specific environmental performance criteria. This document can be used in whole or in part to systematically improve environmental management. Claims of conformity to this document, however, are not acceptable unless all its requirements are incorporated into an organization’s environmental management system and fulfilled without exclusion.
- Standard36 pagesEnglish languagesale 15% off
- Standard36 pagesEnglish languagesale 15% off
- Standard38 pagesFrench languagesale 15% off
- Standard38 pagesFrench languagesale 15% off
- Standard38 pagesSpanish languagesale 15% off
- Standard38 pagesSpanish languagesale 15% off
This document specifies requirements for implantation test methods for preclinical assessment of the local effects after implantation of medical devices or materials intended for use in medical devices. This document is applicable to the evaluation of local tissue responses from medical devices that are intended to be used where skin or mucosal tissue is breached, when required. This document is applicable to medical device or materials that require implantation evaluation and can be solid or non-solid (such as porous materials, liquids, gels, pastes, powders, and particulates), absorbable, degradable, non- absorbable, or can be tissue-engineered medical products (TEMPs). These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical loading or functional performance. This document also does not provide guidance on methods and study design to satisfy requirements for systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the study designs can be modified to also assess other biological effects.
- Standard41 pagesEnglish languagesale 15% off
- Standard44 pagesFrench languagesale 15% off
IEC 63522-41:2026 provides guidelines for the insulation coordination of electromechanical elementary, solid state, time, forcibility guided and reed relays as well reed contacts and hybrid switching solutions. This document can also be used for similar devices when specified in a detail specification.
- Standard63 pagesEnglish and French languagesale 15% off
- Standard63 pagesEnglish and French languagesale 15% off
This document specifies a practical procedure to create and verify distance-speed diagrams and speed curves using the parameters specified in ISO 24675-1, from which the shortest running time for railway timetabling is obtained by numerically integrating the speed curves. This document excludes running time calculation used for purposes other than timetabling.
- Standard23 pagesEnglish languagesale 15% off
- Standard25 pagesFrench languagesale 15% off
This document specifies requirements and guidelines for: the design parameters to be provided to the heating, ventilation and air conditioning (HVAC) unit manufacturer by the rolling stock manufacturer (“Customer”) and the railway operator, the test and inspection items, requirements and methods used by the HVAC unit manufacturer to verify that the HVAC unit conforms with the design parameters. This document is applicable to HVAC units for the passenger area and driver’s cabs in urban (metro, tramway), suburban, regional and main line vehicles.
- Standard68 pagesEnglish languagesale 15% off
- Draft72 pagesFrench languagesale 15% off
- Draft72 pagesFrench languagesale 15% off
IEC TS 63529:2026, which is a Technical Specification, is intended to inform and guide the harmonic design of the DC side of HVDC projects. It considers all aspects of AC current and voltage occurring on the DC circuit and also the interaction with adjacent systems.
The switching action in HVDC converters results in a wide spectrum of harmonics. These range from the fundamental frequency to the radio frequency range. Traditionally the specification of DC side harmonic performance has been limited to the frequency range of interest for induced audible noise on nearby telephone systems. Often a limit of 50th harmonic has been applied, corresponding to 2 500 Hz or 3 000 Hz on 50 Hz and 60 Hz systems respectively. Occasionally the range has been extended to 5 000 Hz. This frequency range has corresponded to the spectrum of characteristic harmonic generation from thyristor line commutated converters (LCC).
The introduction of HVDC voltage sourced converters (VSC) has meant that although the magnitude of DC side harmonic generation from these converters is generally lower, the generated spectrum of interest extends to higher frequencies.
The scope of this document therefore covers the frequency range up to approximately 5 000 Hz. Higher frequencies are mentioned only when relevant. The scope excludes the much higher frequency ranges appropriate to PLC communication and the radio interference spectra.
- Technical specification270 pagesEnglish languagesale 15% off
IEC 62792:2026 specifies a method for measuring the electrical outputs, current and high voltage, from electroshock weapons (ESWs) that deliver an electrical stimulus to humans. This document is applicable to any and all ESWs.
- Standard41 pagesEnglish languagesale 15% off
- Standard87 pagesEnglish languagesale 15% off
IEC TS 63222‑4:2026 specifies the requirements of the models, methods and procedures for harmonic analysis on the public electric power network. This document is applicable to harmonic analysis up to 40th harmonic at high, medium and low voltage of the public electric power network with nominal frequency of 50 Hz or 60 Hz.
- Technical specification50 pagesEnglish languagesale 15% off
IEC 60310:2026 specifies the terms and definitions, classification, service conditions, characteristics and test methods for transformers and inductors on board rolling stock. This document is applicable to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design. This document is also applicable to the traction transformers of three-phase AC line-side powered vehicles and to the transformers inserted in the single-phase or polyphase auxiliary circuits of vehicles, after agreement between purchaser and manufacturer. This document does not apply to instrument transformers, transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase, and inductors of a rated output below 1 kVAR single-phase or 5 kVAR poly-phase on board rolling stock. This document does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on transformers or inductors, which are tested separately according to the relevant rules. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) typical circuits for transformer and inductors are added;
b) letter symbols for cooling methods are added;
c) dielectric test table is modified;
d) subclauses for the tests of transformers and inductors are restructured;
e) temperature test for dry type transformer and dry type inductors are separated in different subclauses;
f) requirements for shock and vibration tests are updated according to IEC 61373:20.
- Standard76 pagesEnglish languagesale 15% off
- Standard163 pagesEnglish languagesale 15% off
This part of IEC 60115 is applicable to leaded fixed low-power film resistors for use in electronic equipment and is applicable to the drafting of detail specifications for leaded fixed low-power film resistors classified to level G, which is defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. The resistors covered herein are classified to level G, as defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. Since the documents of the 60115-X series are exempted from the parallel procedure (D162/C089), this New Work Item Proposal aims to endorse the main IEC document IEC 60115-2-10:2023 as a European standard. The standard shall be published together with the finalised Common Modifications.
- Draft48 pagesEnglish languagee-Library read for1 day
IEC 60245-8:2026 defines the particular requirements for rubber insulated and textile braid covered cords of rated voltage 300/300 V, for use in applications where high flexibility is required, for example iron cords, which apply in addition to the general requirements specified in IEC 60245-1, which apply to all cables. The tests for cables specified in the IEC 60245 series are described in IEC 63294.
IEC 60245-8:2026 includes the following significant technical changes with respect to the previous edition:
a) reference to IEC 60245-2 for the tests has been deleted and replaced by IEC 63294;
b) reference to lift cable according to IEC 60245-5 has been deleted;
c) normative references have been updated.
This document is to be used in conjunction with IEC 60245-1.
- Standard11 pagesEnglish languagesale 15% off
- Standard23 pagesEnglish languagesale 15% off
ISO 80601-2-69:2026 This document is applicable to a transit-operable and non-transit-operable oxygen concentrator. This document is applicable to an oxygen concentrator integrated into or used with other medical devices, ME equipment or ME systems.
EXAMPLE 1 An oxygen concentrator with integrated oxygen conserving equipment function or humidifier function.
EXAMPLE 2 An oxygen concentrator used with a flowmeter stand.
EXAMPLE 3 An oxygen concentrator as part of an anaesthetic system for use in areas with limited logistical supplies of electricity and anaesthetic gases[2].
EXAMPLE 4 An oxygen concentrator with an integrated liquid reservoir function or gas cylinder filling system function.
This document is also applicable to those accessories intended by their manufacturer to be connected to an oxygen concentrator, where the characteristics of those accessories can affect the basic safety or essential performance of the oxygen concentrator.
NOTE 2 Such accessories can include, but are not limited to, masks, cannulae, extension tubing, humidifiers, carts, carrying cases, external power sources and oxygen conserving equipment.
This document does not specify requirements for oxygen concentrators for use with a medical gas pipeline system.
If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.
Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard.
NOTE 3 See also 4.2 of the general standard.
- Standard68 pagesEnglish languagesale 15% off
- Standard76 pagesFrench languagesale 15% off
IEC 60730-2-15:2026 applies to automatic electrical air flow, water flow and water level sensing controls
- for use in, on, or in association with boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "automatic electrical air flow, water flow and water level sensing controls".
EXAMPLE 1 Water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications.
- for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 2 Independently mounted air flow, water flow and water level sensing controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2.
- for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 3 Controls for commercial boilers, heating and air-conditioning equipment.
- that are smart enabled controls;
EXAMPLE 4 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone.
- that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
- used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
- utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
- using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
- that are mechanically or electrically operated, responsive to or controlling air flow, water flow and water level;
- as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
- the inherent safety of automatic electrical air flow, water flow and water level sensing controls, and
- functional safety of automatic air flow, water flow and water level sensing electrical controls and safety related systems,
- controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electrical air flow, water flow and water level sensing controls used in, on, or in association with an equipment.
This document takes into account the response value of an automatic action of a control where such a response value is dependent upon the method of mounting the control. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies.
This document does not
- apply to air flow, water flow and water level sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate air flow, water flow and water level sensing controls intended specifically for industrial applications in cases where no relevant safety standard exists;
- address the integrity of the output sign
- Standard339 pagesEnglish languagesale 15% off
- Standard88 pagesEnglish and French languagesale 15% off
- Standard88 pagesEnglish and French languagesale 15% off
This part of IEC 60115 is applicable to fixed surface mount resistors for use in electronic equipment. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology. These resistors have metallized terminations and are primarily intended to be mounted directly onto a circuit board. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60115-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor. Since the documents of the 60115-X series are exempted from the parallel procedure (D162/C089), this New Work Item Proposal aims to endorse the main IEC document IEC 60115-8:2023 as a European standard. The standard shall be published together with the finalised Common Modifications.
- Draft107 pagesEnglish languagee-Library read for1 day
IEC 63545:2026 specifies safety requirements for horticultural luminaires, incorporating electric light sources for operation from supply voltage up to 1 000 V.
- Draft23 pagesEnglish languagee-Library read for1 day
This part of IEC 60115 is applicable to fixed surface mount resistors for use in electronic equipment. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology. These resistors have metallized terminations and are primarily intended to be mounted directly onto a circuit board. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60115-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor
- Draft7 pagesEnglish languagee-Library read for1 day
IEC 63041-3:2026 is available as IEC 63041-3:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 63041-3:2026 is applicable to piezoelectric physical sensors mainly used in the field of process control, wireless monitoring, dynamics, thermodynamics, vacuum engineering, and environmental sciences. This document provides users with technical guidelines as well as basic knowledge of common physical sensors. Piezoelectric sensors covered herein are those applied to the detection and measurement of physical quantities such as force, pressure, torque, viscosity, temperature, film thickness, acceleration, vibration, and tilt angle. This edition includes the following significant technical changes with respect to the previous edition: a) Some terms in Clause 3 have been updated to be consistent with IEC TS 61994-5:2023.
- Draft16 pagesEnglish languagee-Library read for1 day
ISO 80601-2-74:2026 This document applies to the basic safety and essential performance of a humidifier, also hereafter referred to as ME equipment, in combination with its accessories, the combination also hereafter referred to as ME system.
This document is also applicable to those accessories intended by their manufacturer to be connected to a humidifier where the characteristics of those accessories can affect the basic safety or essential performance of the humidifier.
EXAMPLE 1 Heated breathing tubes (heated-wire breathing tubes) or ME equipment intended to control these heated breathing tubes (heated breathing tube controllers).
NOTE 2 Heated breathing tubes and their controllers are ME equipment and are subject to the requirements of IEC 60601‑1.
NOTE 3 ISO 5367 specifies other safety and performance requirements for breathing tubes.
This document includes requirements for the different medical uses of humidification, such as invasive ventilation, non-invasive ventilation, nasal high-flow therapy, and obstructive sleep apnoea therapy, as well as humidification therapy for tracheostomy patients.
NOTE 4 A humidifier can be integrated into other equipment. When this is the case, the requirements of the other equipment also apply to the humidifier.
EXAMPLE 2 Heated humidifier incorporated into a critical care ventilator where ISO 80601‑2-12 also applies.
EXAMPLE 3 Heated humidifier incorporated into a homecare ventilator for dependent patients where ISO 80601‑2‑72 also applies.
EXAMPLE 4 Heated humidifier incorporated into sleep apnoea therapy equipment where ISO 80601‑2‑70 also applies.
EXAMPLE 5 Heated humidifier incorporated into ventilatory support equipment where either ISO 80601-2-79 or ISO 80601-2-80 also apply.
EXAMPLE 6 Heated humidifier incorporated into respiratory high-flow therapy equipment where ISO 80601‑2‑90 also applies.
This document also includes requirements for an active HME (heat and moisture exchanger), ME equipment which actively adds heat and moisture to increase the humidity level of the gas delivered from the HME to the patient. This document is not applicable to a passive HME, which returns a portion of the expired moisture and heat of the patient to the respiratory tract during inspiration without adding heat or moisture.
NOTE 5 ISO 9360‑1 and ISO 9360‑2 specify safety and performance requirements for a passive HME.
NOTE 6 If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.
Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.
NOTE 7 Additional information can be found in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 4.2.
This document does not specify the requirements for cold pass-over or cold bubble-through humidification devices, the requirements for which are given in ISO 20789.
This document is not applicable to equipment commonly referred to as “room humidifiers” or humidifiers used in heating, ventilation and air conditioning systems, or humidifiers incorporated into infant incubators to humidify the chamber air (i.e., are not directly connected to the patient).
This document is not applicable to nebulizers used for the delivery of a drug to patients.
NOTE 8 ISO 27427 specifies the safety and performance requirements for nebulizers.
- Standard113 pagesEnglish languagesale 15% off
- Standard124 pagesFrench languagesale 15% off
This part of IEC 60115 is applicable to fixed low-power film resistors with termination leads for use in electronic equipment, which are typically assembled in through-hole technology (THT) on circuit boards. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology. The resistive element of these resistors is typically protected by a conformal lacquer coating. These resistors have wire terminations and are primarily intended to be mounted on a circuit board in through-hole technique. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60115-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor.
- Draft98 pagesEnglish languagee-Library read for1 day
This part of IEC 60115 is applicable to fixed low-power film resistors with termination leads for use in electronic equipment, which are typically assembled in through-hole technology (THT) on circuit boards. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology. The resistive element of these resistors is typically protected by a conformal lacquer coating. These resistors have wire terminations and are primarily intended to be mounted on a circuit board in through-hole technique. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60115-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor. Since the documents of the 60115-X series are exempted from the parallel procedure (D162/C089), this New Work Item Proposal aims to endorse the main IEC document IEC 60115-2:2023 as a European standard. The standard shall be published together with the finalised Common Modifications.
- Draft9 pagesEnglish languagee-Library read for1 day
This part of IEC 60115 is applicable to leaded fixed low-power film resistors for use in electronic equipment and is applicable to the drafting of detail specifications for leaded fixed low-power film resistors classified to level G, which is defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. The resistors covered herein are classified to level G, as defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. This detail specification is based upon the blank detail specification IEC 60115-2-10:202X. This detail specification establishes test schedules and performance requirements permitting the quality assessment of the resistors covered herein according to the quality assessment procedures prescribed by IEC 60115-1:2020, Annex Q.
- Draft5 pagesEnglish languagee-Library read for1 day
This part of IEC 60115 is applicable to fixed power resistors for use in electronic equipment. This standard relates to resistors having a rated dissipation typically greater than 1W up to and including 1000W for use in electronic equipment. This standard is applicable to fixed power resistors with a maximum surface temperature (MET) higher than the preferred upper category temperature (UCT) of 200°C. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology. The resistive element of these resistors is typically - protected by a conformal lacquer coating or - cement coating or - vitreous enamel or - a ceramic body or - any other housing, which is to be described in the relevant specification. The electrical connection of these resistors is typically achieved by means of - lead wire terminations or - punched terminals or lug terminals or - push on terminals or - screw terminals or - any other termination, which is to be described in the relevant specification In special cases, a heat sink may be applicable but not mandatory. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60115-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted. Since the documents of the 60115-X series are exempted from the parallel procedure (D162/C089), this New Work Item Proposal aims to endorse the main IEC document IEC 60115-4:2022 as a European standard. The standard shall be published together with the finalised Common Modifications.
- Draft116 pagesEnglish languagee-Library read for1 day
- Draft7 pagesEnglish languagee-Library read for1 day
This document provides general product category rules (PCR) for Type III environmental declarations for wood and wood-based products, including wood-based panels, for use in construction and related construction and in-service processes.
This document complements the core rules for the product category of construction products as defined in EN 15804 and is intended to be used in conjunction with EN 15804.
This document does not cover the assessment of social and economic performances at product level.
The core PCR:
— define the parameters to be declared and the way in which they are collated and reported;
— describe which stages of a product’s life cycle are considered in the EPD and which processes are to be included in the life cycle stages;
— define rules for the development of scenarios;
— include the rules for calculating the life cycle inventory and the life cycle impact assessment underlying the EPD, including the specification of the data quality to be applied;
— include the rules for reporting predetermined, environmental and health information, that is not covered by LCA for a product, construction process and construction service where necessary;
— define the conditions under which construction products can be compared based on the information provided by EPD.
For the EPD of construction services, the same rules and requirements apply as for the EPD of construction products.
Additionally, to the common parts of EN 15804, this document for wood and wood-based products:
— defines the system boundaries;
— defines the rules for modelling and assessment of material-specific characteristics such as carbon content and net calorific value of wood;
— defines allocation procedures for multi-output processes along the wood chain;
— defines allocation procedures for reuse, recycling and energy recovery;
— includes the rules for calculating the life cycle inventory and the life cycle impact assessment underlying the EPD, including the assessment of carbon and net calorific value of wood;
— provides guidance/specific rules for the determination of the reference service life (RSL).
- Draft41 pagesEnglish languagee-Library read for1 day
This document specifies a test method and the minimum requirements for bactericidal and yeasticidal and/or fungicidal and/or tuberculocidal and/or mycobactericidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document is applicable to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices by wiping or mopping - regardless if they are covered by the Medical Device Regulation [7] or not.
Due to the new methods of application of surface disinfectants like pre-impregnated wipes this document was established to cover the different application methods.
FprEN 16615 is applicable for four methods of application of products for wiping and/or mopping:
a) soaking any non-specified wipe or mop with product;
b) spraying the product on any non-specified wipe and / or mop or a specified wipe or mop;
c) impregnation of specified wipes or mops by the user with the product according to the manufacturer’s recommendation;
d) pre-impregnation of specified wipes or mop by the manufacturer as ready-to-use wipes or mops.
In all types of application, the water control is done with the standard wipe (5.3.2.17.1), because it is a process or method control.
This document does not apply to products that are sprayed on or flooding surfaces, without wiping in the contact time. In this case, the methods of phase 2/ stage 2 without mechanical action apply.
The test-surface (5.3.2.16) was selected as standard surface to cover all non-porous surfaces. This document does not apply to the testing of the influence of different surfaces.
This document is applicable to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patients.
NOTE This method corresponds to a phase 2, step 2 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
- Draft53 pagesEnglish languagee-Library read for1 day
This document specifies a general method of test for determining the oil absorption value of a sample of pigment or extender. The oil absorption value is usually required to be compared with the value determined at the same time on an agreed sample of the product.
- Standard12 pagesEnglish languagee-Library read for1 day
This document specifies requirements and test methods for durability, strength, security and functionality of sliding closing devices (SCDs) for windows and door height windows.
This document does not specifically cover the handles used in handle-operated SCDs or the sash fasteners used in cam-operated SCDs, requirements and test methods for which are given in EN 13126 2, EN 13126 3 and EN 13126 14, respectively.
The performance tests incorporated in this document are considered to be reproducible and as such will provide a consistent and objective assessment of the performance of these products throughout CEN Member States.
- Draft22 pagesEnglish languagee-Library read for1 day
- Draft4 pagesEnglish languagee-Library read for1 day
This document specifies quality requirements for the chart, test procedure and acceptance level for near, far, and colour vision acuity of NDT personnel. Information for grey scale perception and low contrast can be found in the annexes. This document also specifies the qualification requirements for personnel permitted to carry out the test.
This document is only applicable to vision acuity under defined conditions similar to those encountered during routine NDT inspection. This document does not address an individual’s overall visual acuity and users are advised to consider the need for a general eye examination by specialist medical personnel to ensure general vision acuity.
- Draft21 pagesEnglish languagee-Library read for1 day
This document specifies a method [1] for the quantitative determination of saxitoxin (STX), decarbamoyl saxitoxin (dcSTX), neosaxitoxin (NEO), decarbamoyl neosaxitoxin (dcNEO), gonyautoxin 1 and 4 (GTX1,4; sum of isomers), gonyautoxin 2 and 3 (GTX2,3; sum of isomers), gonyautoxin 5 (GTX5), gonyautoxin 6 (GTX6), decarbamoyl gonyautoxin 2 and 3 (dcGTX2,3; sum of isomers), N-sulfocarbamoyl gonyautoxin 2 and 3 (C1,2; sum of isomers) and N-sulfocarbamoyl gonyautoxin 1 and 4 (C3,4; sum of isomers) in (raw) mussels, oysters, scallops and clams. Laboratory experience has shown that this document can also be applied to other marine invertebrates [2], [3] and processed products of those species, however, no complete interlaboratory validation study according to ISO 5725-2 [21] has been carried out so far. The method described was validated in an interlaboratory study [4], [5] and was also verified in a European Union Reference Laboratory for Marine Biotoxins (EURLMB)-performance test aiming the total toxicity of the samples [6]. Toxins which were not available in the first interlaboratory study [4], [5] as dcGTX2,3 and dcNEO were validated in two additional interlaboratory studies [7], [8]. The lowest validated levels [4], [5], [8], are given as mass fraction of toxin (free base) in µg/kg shellfish tissue and also as µmol/kg shellfish tissue and are listed in Table 1.
[Table 1 - Lowest validated levels]
A quantitative determination of GTX6 was not included in the first interlaboratory study but several laboratories detected this toxin directly after solid phase extraction with ion-exchange (SPE-COOH) clean-up and reported a mass fraction (free base) of 30 µg/kg or higher in certain samples. For that reason, the present method is applicable to quantify GTX6 directly, depending on the availability of the standard substance. Whenever GTX6 standard is not commercially available, it is possible to determine GTX6 after hydrolysis of Fraction 2 of the SPE-COOH clean-up, described in 7.4, as NEO. The indirect quantification of GTX6 was validated in two additional interlaboratory studies [7], [8]. A study to compare direct and indirect GTX6 quantification was conducted at the EURLMB [16].
A quantitative determination of C3,4 was included in the first interlaboratory study. The present method is applicable to quantify C3,4 directly, depending on the availability of the standard substance. If no standard substances are available, C3,4 can only be quantified as GTX1,4 if the same hydrolysis protocol used for GTX6 (7.4) is applied to Fraction 1 of the SPE-COOH clean-up [10]. A study to compare direct and indirect C3,4 quantification was conducted at the EURLMB [16].
- Draft70 pagesEnglish languagee-Library read for1 day
This document specifies the characteristics of grooved pins with one-third-length centre oval grooves (with closed ends), in steel and stainless steel, and with a nominal diameter from 1 mm to 25 mm.
These grooved pins are designed to fulfil the main following functions:
relative rotation of the assembled parts, and
positioning or guiding,
with an easy installation (due to its symmetrical shape) and a medium level of pull-out resistance (due to the elastic fit behaviour of the pin).
The general requirements (including functional principles for grooved pins and assembly) are specified in ISO 13669.
- Draft12 pagesEnglish languagee-Library read for1 day
This document describes a test method for the determination of the flash point of chemicals, lube oils, fuels including aviation turbine fuel, diesel fuel, diesel/biodiesel blends and related products. The precision of this method has been determined over the range of 24,5 °C to 229,5 °C.
NOTE Apparatus can determine the flash point at higher or lower temperatures than the precision range, however the precision has not been determined.
- Draft20 pagesEnglish languagee-Library read for1 day
NOTE 1 There is guidance or rationale for this Clause in A.2.1.
This document specifies the requirements for information supplied by the manufacturer for a medical device or an accessory, as defined in 3.1. This document includes the generally applicable requirements for identification and labels on a medical device or accessory, the packaging, marking of a medical device or accessory, and accompanying information. This document does not specify the means by which the information is to be supplied.
NOTE 2 Some authorities having jurisdiction impose different requirements for the identification, marking and documentation of a medical device or accessory.
Specific requirements of medical device product standards or group standards take precedence over requirements of this document.
- Draft72 pagesEnglish languagee-Library read for1 day
RTBR/SMG-0019R1
- Standardization document104 pagesEnglish languagee-Library read for1 day
DEN/ERM-TGAERO-31-1
- Standard45 pagesEnglish languagesale 15% off
- Standard45 pagesEnglish languagesale 15% off
- Standard45 pagesEnglish languagee-Library read for1 day
The present document specifies technical requirements, limits and test methods for Short Range Devices in the non-
specific category operating in the frequency range 25 MHz to 1 000 MHz.
The non specific SRD category is defined by the EU Commission Decision 2019/1345/EU [i.3] as:
"The non-specific short-range device category covers all kinds of radio devices, regardless of the application or the
purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry,
telecommand, alarms, data transmissions in general and other applications".
These radio equipment types are capable of transmitting up to 500 mW effective radiated power and operating indoor or
outdoor.
NOTE: The relationship between the present document and the essential requirements of article 3.2 of
Directive 2014/53/EU [i.2] is given in Annex A
- Standard107 pagesEnglish languagesale 15% off
- Standard107 pagesEnglish languagesale 15% off
- Standard107 pagesEnglish languagee-Library read for1 day
DEN/ERM-TG28-561
- Standard100 pagesEnglish languagesale 15% off
- Standard100 pagesEnglish languagesale 15% off
- Standard100 pagesEnglish languagee-Library read for1 day
REN/MSG-TFES-15-3
- Standard67 pagesEnglish languagesale 15% off
- Standard67 pagesEnglish languagesale 15% off
- Standard67 pagesEnglish languagee-Library read for1 day
SIGNIFICANCE AND USE
4.1 This practice shall be used when ultrasonic inspection is required by the order or specification for inspection purposes where the acceptance of the forging is based on limitations of the number, amplitude, or location of discontinuities, or a combination thereof, which give rise to ultrasonic indications.
4.2 The acceptance criteria shall be clearly stated as order requirements.
SCOPE
1.1 This practice for ultrasonic examination covers turbine and generator steel rotor forgings covered by Specifications A469/A469M, A470/A470M, A768/A768M, and A940/A940M. This practice shall be used for contact testing only.
1.2 This practice describes a basic procedure of ultrasonically inspecting turbine and generator rotor forgings. It does not restrict the use of other ultrasonic methods such as reference block calibrations when required by the applicable procurement documents nor is it intended to restrict the use of new and improved ultrasonic test equipment and methods as they are developed.
1.3 This practice is intended to provide a means of inspecting cylindrical forgings so that the inspection sensitivity at the forging center line or bore surface is constant, independent of the forging or bore diameter. To this end, inspection sensitivity multiplication factors have been computed from theoretical analysis, with experimental verification. These are plotted in Fig. 1 (bored rotors) and Fig. 2 (solid rotors), for a true inspection frequency of 2.25 MHz, and an acoustic velocity of 2.30 in./s × 105 in./s [5.85 cm/s × 105 cm/s]. Means of converting to other sensitivity levels are provided in Fig. 3. (Sensitivity multiplication factors for other frequencies may be derived in accordance with X1.1 and X1.2 of Appendix X1.)
FIG. 1 Bored Forgings
Note 1: Sensitivity multiplication factor such that a 10 % indication at the forging bore surface will be equivalent to a 1/8 in. [3 mm] diameter flat bottom hole. Inspection frequency: 2.0 MHz or 2.25 MHz. Material velocity: 2.30 in./s × 105 in./s [5.85 cm/s × 105 cm/s].
FIG. 2 Solid Forgings
Note 1: Sensitivity multiplication factor such that a 10 % indication at the forging centerline surface will be equivalent to a 1/8 in. [3 mm] diameter flat bottom hole. Inspection frequency: 2.0 MHz or 2.25 MHz. Material velocity: 2.30 in./s × 105 in./s [5.85 cm/s × 105 cm/s].
FIG. 3 Conversion Factors to Be Used in Conjunction with Fig. 1 and Fig. 2 if a Change in the Reference Reflector Diameter is Required
1.4 Considerable verification data for this method have been generated which indicate that even under controlled conditions very significant uncertainties may exist in estimating natural discontinuities in terms of minimum equivalent size flat-bottom holes. The possibility exists that the estimated minimum areas of natural discontinuities in terms of minimum areas of the comparison flat-bottom holes may differ by 20 dB (factor of 10) in terms of actual areas of natural discontinuities. This magnitude of inaccuracy does not apply to all results but should be recognized as a possibility. Rigid control of the actual frequency used, the coil bandpass width if tuned instruments are used, and so forth, tend to reduce the overall inaccuracy which is apt to develop.
1.5 This practice for inspection applies to solid cylindrical forgings having outer diameters of not less than 2.5 in. [64 mm] nor greater than 100 in. [2540 mm]. It also applies to cylindrical forgings with concentric cylindrical bores having wall thicknesses of 2.5 [64 mm] in. or greater, within the same outer diameter limits as for solid cylinders. For solid sections less than 15 in. [380 mm] in diameter and for bored cylinders of less than 7.5 in. [190 mm] wall thickness the transducer used for the inspection will be different than the transducer used for larger sections.
1.6 Supplementary requirements of an optional nature are provided for use at the option of the...
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 The honeycomb tensile-node bond strength is a fundamental property than can be used in determining whether honeycomb cores can be handled during cutting, machining and forming without the nodes breaking. The tensile-node bond strength is the tensile stress that causes failure of the honeycomb by rupture of the bond between the nodes. It is usually a peeling-type failure.
5.2 This test method provides a standard method of obtaining tensile-node bond strength data for quality control, acceptance specification testing, and research and development.
SCOPE
1.1 This test method covers the determination of the tensile-node bond strength of honeycomb core materials.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 The determination of the creep rate provides information on the behavior of sandwich constructions under constant applied force. Creep is defined as deflection under constant force over a period of time beyond the initial deformation as a result of the application of the force. Deflection data obtained from this test method can be plotted against time, and a creep rate determined. By using standard specimen constructions and constant loading, the test method may also be used to evaluate creep behavior of sandwich panel core-to-facing adhesives.
5.2 This test method provides a standard method of obtaining flexure creep of sandwich constructions for quality control, acceptance specification testing, and research and development.
5.3 Factors that influence the sandwich construction creep response and shall therefore be reported include the following: facing material, core material, adhesive material, methods of material fabrication, facing stacking sequence and overall thickness, core geometry (cell size), core density, core thickness, adhesive thickness, specimen geometry, specimen preparation, specimen conditioning, environment of testing, specimen alignment, loading procedure, speed of testing, facing void content, adhesive void content, and facing volume percent reinforcement. Further, facing and core-to-facing strength and creep response may be different between precured/bonded and co-cured facesheets of the same material.
SCOPE
1.1 This test method covers the determination of the creep characteristics and creep rate of flat sandwich constructions loaded in flexure, at any desired temperature. Permissible core material forms include those with continuous bonding surfaces (such as balsa wood and foams) as well as those with discontinuous bonding surfaces (such as honeycomb).
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text the inch-pound units are shown in brackets. The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 This test method simulates the hydrostatic loading conditions which are often present in actual sandwich structures, such as marine hulls. This test method can be used to compare the two-dimensional flexural stiffness of a sandwich composite made with different combinations of materials or with different fabrication processes. Since it is based on distributed loading rather than concentrated loading, it may also provide more realistic information on the failure mechanisms of sandwich structures loaded in a similar manner. Test data should be useful for design and engineering, material specification, quality assurance, and process development. In addition, data from this test method would be useful in refining predictive mathematical models or computer code for use as structural design tools. Properties that may be obtained from this test method include:
5.1.1 Panel surface deflection at load,
5.1.2 Panel face-sheet strain at load,
5.1.3 Panel bending stiffness,
5.1.4 Panel shear stiffness,
5.1.5 Panel strength, and
5.1.6 Panel failure modes.
SCOPE
1.1 This test method determines the two-dimensional flexural properties of sandwich composite plates subjected to a distributed load. The test fixture uses a relatively large square panel sample which is simply supported all around and has the distributed load provided by a water-filled bladder. This type of loading differs from the procedure of Test Method C393, where concentrated loads induce one-dimensional, simple bending in beam specimens.
1.2 This test method is applicable to composite structures of the sandwich type which involve a relatively thick layer of core material bonded on both faces with an adhesive to thin-face sheets composed of a denser, higher-modulus material, typically, a polymer matrix reinforced with high-modulus fibers.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text the inch-pound units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard12 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in bath and shower areas as a base for the application of ceramic or plastic tile. Coated glass mat water-resistant gypsum backing panel shall consist of a noncombustible water-resistant gypsum core, surfaced with glass mat, partially or completely embedded in the core, and with a water-resistant coating on one surface. The specimens shall be tested for flexural strength, humidified deflection, core hardness, end hardness, edge hardness, nail pull resistance, water resistance, and surface water absorption. Coated glass mat water-resistant gypsum backing panel shall have surfaces true and free of imperfections that render the panel unfit for its designed use.
SCOPE
1.1 This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in bath and shower areas as a base for the application of ceramic or plastic tile.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Within the text, the SI units are shown in brackets.
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification3 pagesEnglish languagesale 15% off
- Technical specification3 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 Coefficients of linear thermal expansion are used, for example, for design purposes and to determine if failure by thermal stress may occur when a solid body composed of two different materials is subjected to temperature variations.
5.2 This test method is comparable to Test Method D3386 for testing electrical insulation materials, but it covers a more general group of solid materials and it defines test conditions more specifically. This test method uses a smaller specimen and substantially different apparatus than Test Methods E228 and D696.
5.3 This test method may be used in research, specification acceptance, regulatory compliance, and quality assurance.
SCOPE
1.1 This test method determines the technical coefficient of linear thermal expansion of solid materials using thermomechanical analysis techniques.
1.2 This test method is applicable to solid materials that exhibit sufficient rigidity over the test temperature range such that the sensing probe does not produce indentation of the specimen.
1.3 The recommended lower limit of coefficient of linear thermal expansion measured with this test method is 5 μm/(m·°C). The test method may be used at lower (or negative) expansion levels with decreased accuracy and precision (see Section 12).
1.4 This test method is applicable to the temperature range from −120 °C to 900 °C. The temperature range may be extended depending upon the instrumentation and calibration materials used.
1.5 SI units are the standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers grades of fuel oil intended for use in various types of fuel-oil-burning equipment under various climatic and operating conditions. These grades include the following: Grades No. 1 S5000, No. 1 S500, No. 2 S5000, and No. 2 S500 for use in domestic and small industrial burners; Grades No. 1 S5000 and No. 1 S500 adapted to vaporizing type burners or where storage conditions require low pour point fuel; Grades No. 4 (Light) and No. 4 (Heavy) for use in commercial/industrial burners; and Grades No. 5 (Light), No. 5 (Heavy), and No. 6 for use in industrial burners. Preheating is usually required for handling and proper atomization. The grades of fuel oil shall be homogeneous hydrocarbon oils, free from inorganic acid, and free from excessive amounts of solid or fibrous foreign matter. Grades containing residual components shall remain uniform in normal storage and not separate by gravity into light and heavy oil components outside the viscosity limits for the grade. The grades of fuel oil shall conform to the limiting requirements prescribed for: (1) flash point, (2) water and sediment, (3) physical distillation or simulated distillation, (4) kinematic viscosity, (5) Ramsbottom carbon residue, (6) ash, (7) sulfur, (8) copper strip corrosion, (9) density, and (10) pour point. The test methods for determining conformance to the specified properties are given.
SCOPE
1.1 This specification (see Note 1) covers grades of fuel oil intended for use in various types of fuel-oil-burning equipment under various climatic and operating conditions. These grades are described as follows:
1.1.1 Grades No. 1 S5000, No. 1 S500, No. 1 S15, No. 2 S5000, No. 2 S500, and No. 2 S15 are middle distillate fuels for use in domestic and small industrial burners. Grades No. 1 S5000, No. 1 S500, and No. 1 S15 are particularly adapted to vaporizing type burners or where storage conditions require low pour point fuel.
1.1.2 Grades B6–B20 S5000, B6–B20 S500, and B6–B20 S15 are middle distillate fuel/biodiesel blends for use in domestic and small industrial burners.
1.1.3 Grades No. 4 (Light) and No. 4 are heavy distillate fuels or middle distillate/residual fuel blends used in commercial/industrial burners equipped for this viscosity range.
1.1.4 Grades No. 5 (Light), No. 5 (Heavy), and No. 6 are residual fuels of increasing viscosity and boiling range, used in industrial burners. Preheating is usually required for handling and proper atomization.
Note 1: For information on the significance of the terminology and test methods used in this specification, see Appendix X1.
Note 2: A more detailed description of the grades of fuel oils is given in X1.3.
1.2 This specification is for the use of purchasing agencies in formulating specifications to be included in contracts for purchases of fuel oils and for the guidance of consumers of fuel oils in the selection of the grades most suitable for their needs.
1.3 Nothing in this specification shall preclude observance of federal, state, or local regulations which can be more restrictive.
1.4 The values stated in SI units are to be regarded as standard.
1.4.1 Non-SI units are provided in Table 1 and Table 2 and in 7.1.2.1/7.1.2.2 because these are common units used in the industry.
Note 3: The generation and dissipation of static electricity can create problems in the handling of distillate burner fuel oils. For more information on the subject, see Guide D4865.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification13 pagesEnglish languagesale 15% off
- Technical specification13 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 This test method measures a lubricant's ability to protect hypoid final drive axles from abrasive wear, adhesive wear, plastic deformation, and surface fatigue when subjected to low-speed, high-torque conditions. Lack of protection can lead to premature gear or bearing failure, or both.
5.2 This test method is used, or referred to, in specifications and classifications of rear-axle gear lubricants such as:
5.2.1 Specification D7450.
5.2.2 American Petroleum Institute (API) Publication 1560.
5.2.3 SAE J308.
5.2.4 SAE J2360.
SCOPE
1.1 This test method, commonly referred to as the L-37-1 test, describes a test procedure for evaluating the load-carrying capacity, wear performance, and extreme pressure properties of a gear lubricant in a hypoid axle under conditions of low-speed, high-torque operation.3
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.2.1 Exceptions—Where there is no direct SI equivalent such as National Pipe threads/diameters, tubing size, or where there is a sole source supply equipment specification.
1.2.1.1 The drawing in Annex A6 is in inch-pound units.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are provided in 7.2 and 10.1.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard18 pagesEnglish languagesale 15% off
- Standard18 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers the testing and requirements for two types and two classes of asbestos-free asphalt roof cement consisting of an asphalt base, volatile petroleum solvents, and mineral and/or other stabilizers, mixed to a smooth, uniform consistency suitable for trowel application to roofing and flashing. Type I is made from asphalts characterized as self-healing, adhesive, and ductile, while Type II is made from asphalt characterized by high softening point and relatively low ductility. Class I is used for application to essentially dry surfaces, while Class II is used for application to damp, wet, or underwater surfaces. The roof cements shall comply with composition limits for water, nonvolatile matter, mineral and/or other stabilizers, and bitumen (asphalt). They shall also meet physical requirements such as uniformity, workability, and pliability and behavior at given temperatures.
SCOPE
1.1 This specification covers asbestos-free asphalt roof cement suitable for trowel application to roofings and flashings.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.3 The following precautionary caveat pertains only to the test method portion, Section 8 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification2 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 Often the most critical stress to which a sandwich panel core is subjected is shear. The effect of repeated shear stresses on the core material can be very important, particularly in terms of durability under various environmental conditions.
5.2 This test method provides a standard method of obtaining the sandwich core shear fatigue response. Uses include screening candidate core materials for a specific application, developing a design-specific core shear cyclic stress limit, and core material research and development.
Note 3: This test method may be used as a guide to conduct spectrum loading. This information can be useful in the understanding of fatigue behavior of core under spectrum loading conditions, but is not covered in this standard.
5.3 Factors that influence core fatigue response and shall therefore be reported include the following: core material, core geometry (density, cell size, orientation, etc.), specimen geometry and associated measurement accuracy, specimen preparation, specimen conditioning, environment of testing, specimen alignment, loading procedure, loading frequency, force (stress) ratio and speed of testing (for residual strength tests).
Note 4: If a sandwich panel is tested using the guidance of this standard, the following may also influence the fatigue response and should be reported: facing material, adhesive material, methods of material fabrication, adhesive thickness and adhesive void content. Further, core-to-facing strength may be different between precured/bonded and co-cured facings in sandwich panels with the same core and facing materials.
SCOPE
1.1 This test method determines the effect of repeated shear forces on core material used in sandwich panels. Permissible core material forms include those with continuous bonding surfaces (such as balsa wood and foams) as well as those with discontinuous bonding surfaces (such as honeycomb).
1.2 This test method is limited to test specimens subjected to constant amplitude uniaxial loading, where the machine is controlled so that the test specimen is subjected to repetitive constant amplitude force (stress) cycles. Either shear stress or applied force may be used as a constant amplitude fatigue variable.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. Within the text, the inch-pound units are shown in brackets.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish languagesale 15% off
RTS/TSGC-0329523vh70
- Standard46 pagesEnglish languagesale 15% off
RTS/TSGC-0329521vh50
- Standard77 pagesEnglish languagesale 15% off
DEN/ERM-TGAERO-31-2
- Standard38 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish languagee-Library read for1 day
RTS/LI-00190-2
- Standard61 pagesEnglish languagesale 15% off
RTR/TSGR-0536903ve40
- Standard26 pagesEnglish languagesale 15% off